RECTRON SM120

SM120
THRU
SM160
SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 60 Volts CURRENT 1.0 Ampere
d
e
it nu
FEATURES
*
*
*
*
*
Ideal for surface mounted applications
Low leakage current
Metallurgically bonded construction
Mounting position: Any
Weight: 0.015 gram
n
o
isc
MELF
D
MECHANICAL DATA
* Epoxy : Device has UL flammability classification 94V-0
DISCONTINUED-
.205 ( 5.2 )
.190 ( 4.8 )
"This series is replaced by the FM1XX series that meets to the same
fit and function parameters and share the same solder pad layout.
The FM1XX series is preferred for error-free vacuum pick-up and
PCB assembly."
SOLDERABLE
ENDS
.024 ( 0.6 )
.016 ( 0.4 )
.106 ( 2.7 )
.095 ( 2.4 )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
SM120
SM130
SM140
SM160
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
Volts
Maximum RMS Voltage
VRMS
14
21
28
35
42
Volts
VDC
20
30
40
50
60
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Derating Case Temperature
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
SM150
IO
1.0
Amps
I FSM
40
Amps
Typical Junction Capacitance (Note 2)
CJ
110
pF
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
VF
IR
NOTES : 1. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
SM120
SM130
SM140
.55
SM150
SM160
.70
0.2
2
UNITS
Volts
mA
mA
2007-5
SM1
50~
0
14
SM
0~
60
0.50
0.25
0
SM1
12
Single Phase Half Wave
60Hz Inductive Load
0.75
P.C.B. Mounted on
0.4X0.4"(10 X10mm)
copper pad areas
0
25
50
75
100
125
150
175
INSTANTANEOUS FORWARD CURRENT, (mA)
1.0
SM
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( SM120 THRU SM160 )
100
10
1.0
TA = 100 OC
0.1
TA = 75 OC
TA = 25 OC
0.01
SM120 ~SM140
SM150~SM160
0.001
0
20
O
CJ, JUNCTION CAPACITANCE, (pF)
20
10
SM120 ~SM140
1.0
SM150 ~SM160
0.1
TJ = 25 OC
Pulse width=300mS
1% Duty Cycle
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
40
60
100
120
140
1.7
400
TJ = 25 OC
200
100
80
60
40
20
10
1.9 2.1
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.0
4
10
40 80
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.4 TYPICAL JUNCTION CAPACITANCE
50
8.3mS Single Half Sine-Wave
JEDEC Method
40
30
20
10
0
1
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
CASE TEMPERATURE, ( C)
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Mounting Pad Layout
F-SLOT WIDTH
OPTIMUM PAD SIZE
.100 (2.54)
.100 (2.54)
.100 (2.54)
.200 (5.08)
.300 (7.62)
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.