Optoway SPB-3620WG 1 *********************************************************************************************************************************************************************** SPB-3620WG / SPB-3620BWG / SPB-3620AWG (SC BIDI SFP) (RoHS Compliant) SPB-3620LWG / SPB-3620BLWG / SPB-3620ALWG (LC BIDI SFP) 1310 nm TX / 1550 nm RX , 3.3V / 155 Mbps Digital Diagnostic Single-Fiber SFP Transceiver ********************************************************************************************************************************************************************** FEATURES DESCRIPTION l l l l l l l l l l l l l l l The SPB-3620WG series is small form factor pluggable module for IEEE 802.3ah 100BASE-BX and OC-3/STM-1 SONET/SDH single fiber communications by using 1310 nm transmitter and 1550 nm receiver. It is with the SFP 20-pin connector to allow hot plug capability. Digital diagnostic functions are available via an I2C. The transmitter section uses a multiple quantum well 1310 nm laser and is a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section uses an integrated 1550 nm detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. 1-Fiber Bi-Directional SFP Optical Transceiver Compliant with IEEE 802.3ah-2004 100BASE-BX Simplex SC Connector: SPB-3620WG Simplex LC Connector: SPB-3620LWG SFF-8472 Digital Diagnostic Function 1310 nm LD Transmitter 1550 nm Receiver Distance Up to 20 km AC/AC Coupling according to MSA Single +3.3 V Power Supply RoHS Compliant 0 to 70oC Operating : SPB-3620WG -10 to 85oC Operating : SPB-3620BWG -40 to 85oC Operating : SPB-3620AWG Class 1 Laser International Safety Standard IEC 60825 Compliant APPLICATIONS l WDM Fast Ethernet Links l SONET/SDH Equipment Interconnect l Fiber Channel Links LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC 60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. ORDER INFORMATION P/No. SPB-3620WG SPB-3620BWG SPB-3620AWG SPB-3620LWG SPB-3620BLWG SPB-3620ALWG Bit Rate (Mb/s) 125/155 125/155 125/155 125/155 125/155 125/155 Distance (km) 20 20 20 20 20 20 TX (nm) 1310 1310 1310 1310 1310 1310 RX (nm) 1550 1550 1550 1550 1550 1550 Package SC SFP with DMI SC SFP with DMI SC SFP with DMI LC SFP with DMI LC SFP with DMI LC SFP with DMI Temp TX Power (oC) (dBm) 0 to 70 -8 to -14 -10 to 85 -8 to -14 -40 to 85 -8 to -14 0 to 70 -8 to -14 -10 to 85 -8 to -14 -40 to 85 -8 to -14 RX Sens. (dBm) -33 -33 -33 -33 -33 -33 RoHS Compliant Yes Yes Yes Yes Yes Yes *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0 Optoway SPB-3620WG 2 *********************************************************************************************************************************************************************** Absolute Maximum Ratings Parameter Storage Temperature Operating Case Temperature Symbol Tstg Topr Power Supply Voltage Input Voltage Vcc --- Min -40 0 -10 -40 0 GND Max 85 70 85 85 3.6 Vcc Units o C o C Output Current Iout 0 30 mA Min 3.1 Typ 3.3 200 Max 3.5 300 70 85 85 200 Notes SPB-3620WG SPB-3620BWG SPB-3620AWG V V Recommended Operating Conditions Parameter Power Supply Voltage Power Supply Current Operating Case Temperature Symbol Vcc ICC (TX+RX) Topr 0 -10 -40 Data Rate 125/155 Units / Notes V mA o C / SPB-3620WG o C / SPB-3620BWG o C / SPB-3620AWG Mb/s Transmitter Specifications (0 oC < Topr < 70 oC, 3.1V < Vcc < 3. 5V) Parameter Symbol Min Typ Max Units Notes Optical Optical Transmit Power Po -14 ---8 dBm 1 Output Center Wavelength 1260 1360 nm λ Output Spectrum Width ----5 nm RMS (σ) ∆λ Extinction Ratio ER 8.2 ----dB Output Eye Compliant with Bellcore GR-253-CORE and ITU recommendation G.957 Optical Rise Time tr 2 ns 10% to 90% Values Optical Fall Time tf 2 ns 10% to 90% Values Relative Intensity Noise RIN -116 dB/Hz Total Jitter TJ 1.0 ns 2 Electrical Data Input Current – Low IIL -350 µA Data Input Current – High IIH 350 µA Differential Input Voltage VIH - VIL 0.5 2.4 V Peak-to-Peak TX Disable Input Voltage – Low TDIS, L 0 0.5 V 3 TX Disable Input Voltage – High TDIS, H 2.0 Vcc V 3 TX Disable Assert Time TASSERT 10 µs TX Disable Deassert Time T DEASSERT 1 ms TX Fault Output Voltage -- Low TFaultL 0 0.5 V 4 TX Fault Output Voltage -- High TFaultH 2.0 Vcc+0.3 V 4 Notes: 1. Output power is power coupled into a 9/125 µm single mode fiber. 2. Measured with a 223-1 PRBS. 3. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX. 4. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage). *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0 Optoway SPB-3620WG 3 *********************************************************************************************************************************************************************** Receiver Specifications (0oC < Topr < 70oC, 3.1 V < Vcc < 3. 5V) Parameter Optical Sensitivity Maximum Input Power Signal Detect -- Asserted Signal Detect -- Deasserted Signal detect -- Hysteresis Wavelength of Operation Optical Return Loss Electrical Differential Output Voltage Output LOS Voltage -- Low Output LOS Voltage – High Signal Detect Assert Time Signal Detect Deassert Time Symbol Min Typ Max Units Notes --Pin Pa Pd ---8 ---43 1.0 1480 14 ----------- -33 ---33 --- dBm dBm dBm dBm dB nm dB 5 ORL VOH – VOL VOL V OH ASMAX ANSMAX 1580 0.6 0 2.0 2.0 0.5 Vcc+0.3 100 300 Transition: low to high Transition: high to low 6 V V V µs µs 7 7 OFF to ON ON to OFF Notes: 5. Minimum sensitivity and saturation levels at BER 1E-10 for a 223-1 PRBS. 6. At least 30 dB optical isolation for the wavelength 1260 to 1360 nm. 7. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage). RECOMMENDED CIRCUIT SCHEMATIC VeeT Tx_DISABLE Tx_FAULT (1,17,20) 3 Tx_DISABLE 2 Tx_FAULT 4.7K to 10KΩ LD Driver TD + 18 TD - 19 TD + Z=50Ω 100Ω TD Z=50Ω VccT 1μH 16 Vcc 3.3V 10μF 10nF 10μF 10nF SerDes IC 1μH VccR 15 10μF 10nF RD - 12 Protocol IC RD Z=50Ω 100Ω POST Amp RD + 13 RD + Z=50Ω 4.7K to 10KΩ LOS VeeR MOD_DEF(0) EEPROM MOD_DEF(1) MOD_DEF(2) SFP module depending on SERDES 8 LOSS OF SINGAL (9,10,11,14) 6 MODULE DETECT 5 SCL 4 SDA 4.7K to 10KΩ 4.7K to 10KΩ Vcc 3.3V 4.7K to 10KΩ *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0 Optoway SPB-3620WG 4 *********************************************************************************************************************************************************************** CONNECTION DIAGRAM PIN Signal Name 1 2 3 TX GND TX Fault TX Disable 4 MOD-DFE2 5 MOD-DEF1 6 MOD-DEF0 7 8 9 10 N/C LOS RX GND RX GND Description PIN Transmitter Ground Transmitter Fault Indication Transmitter Disable (Module disables on high or open) Modulation Definition 2 – Two wires serial ID Interface Modulation Definition 1 – Two wires serial ID Interface Modulation Definition 0 – Ground in Module Not Connected Loss of Signal Receiver Ground Receiver Ground 11 12 13 RX GND Receiver Ground RX DATA OUT- Inverse Receiver Data Out RX DATA OUT+ Receiver Data Out Signal Name Description 14 RX GND Receiver Ground 15 Vcc RX Receiver Power – 3.3V±5% 16 Vcc TX Transmitter Power – 3.3V±5% 17 18 19 20 TX GND TX DATA IN+ TX DATA INTX GND Transmitter Ground Transmitter Data In Inverse Transmitter Data In Transmitter Ground Module Definition Module Definition MOD-DEF2 PIN 4 MOD-DEF1 PIN 5 MOD-DEF0 PIN 6 Interpretation by Host 4 SDA SCL LV-TTL Low Serial module definition protocol Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector (NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire serial CMOS E 2PROM protocol of the ATMEL AT24C01A/02/04 family of components. *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0 Optoway SPB-3620WG 5 *********************************************************************************************************************************************************************** PACKAGE DIAGRAM Units in mm A) SC SFP A) LC SFP Note: Specifications subject to change without notice. *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0 Optoway SPB-3620WG 6 *********************************************************************************************************************************************************************** Revision History Version 1.0 2.0 3.0 Subject Release Date Initial datasheet Combine datasheet of SC BIDI SFP and LC BIDI SFP Revise SC BIDI SFP package diagram for high port density use 2005/12/1 2006/3/1 2008/1/1 *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 1/1/2008 V3.0