MICREL SY89838UMG

SY89838U
Precision 1:8 LVDS Clock Fanout Buffer
with 2:1 Runt Pulse Eliminator Input MUX
General Description
The SY89838U is a low jitter, low skew, high-speed
1:8 fanout buffer with a unique, 2:1 differential input
multiplexer (MUX) optimized for redundant source
switchover
applications.
Unlike
standard
multiplexers, the SY89838U unique 2:1 Runt Pulse
Eliminator (RPE) MUX prevents any short cycles or
“runt” pulses during switchover. In addition, a unique
fail-safe input protection prevents metastable
conditions when the selected input clock fails to a
DC voltage (voltage between the pins of the
differential input drops below 100mV). The
SY89838U distributes clock frequencies from 1kHz
to 1.5GHz, guaranteed, over temperature and
voltage.
The differential input includes Micrel’s unique, 3-pin
input termination architecture that allows customers
to interface to any differential signal (AC- or DCcoupled) as small as 100mV (200MvPP) without any
level shifting or termination resistor networks in the
signal path. The outputs are 350mV compatible
LVDS with fast rise/fall times guaranteed to be less
than 150ps.
The SY89838U operates from a 2.5V ±5% supply
and is guaranteed over the full industrial
temperature range of –40°C to +85°C. For
applications that require 800mV LVPECL outputs,
consider the SY89837U. The SY89838U is part of
Micrel’s high-speed, Precision Edge® product line.
All support documentation can be found on Micrel’s
web site at: www.micrel.com.
Precision Edge®
Features
• Selects between two clocks, and provides 8
precision, low skew LVDS output copies
• 2:1 MUX input provides a glitch-free, stable LVDS
output
• Guaranteed AC performance over temperature
and supply voltage:
– Wide operating frequency: 1kHz to >1.5GHz
– <150ps tr/tf
– <40ps output-to-output skew
• Unique patent-pending input isolation design
minimizes crosstalk
• Fail-safe input prevents oscillation
• Ultra-low jitter design:
– <1psRMS random jitter
– <1psRMS cycle-to-cycle jitter
– <10psPP total jitter (clock)
– <0.7psRMS MUX crosstalk induced jitter
• Unique patent-pending input termination and VT
pin accepts DC- and AC-coupled inputs (CML,
PECL, LVDS)
• 350mV LVDS output swing
• Power supply 2.5V +5%
• –40°C to +85°C industrial temperature range
• Available in 32-pin (5mm x 5mm) MLF® package
Applications
• Redundant clock switchover
• Failsafe clock protection
Markets
•
•
•
•
LAN/WAN
Enterprise Servers
ATE
Test and Measurements
Precision Edge is a registered trademark of Micrel, Inc
MicroLeadFrame and MLF are registered trademarks of Amkor Technology, Inc.
September 2006
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Typical Application
September 2006
2
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Ordering Information(1)
Part Number
Package
Type
Operating
Range
Package Marking
Lead
Finish
SY89838UMG
MLF-32
Industrial
SY89838U with bar line
Pb-Free indicator
NiPdAu
Pb-Free
SY89838UMGTR(2)
MLF-32
Industrial
SY89838U with bar line
Pb-Free indicator
NiPdAu
Pb-Free
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = +25°C, DC Electrical only.
2. Tape and Reel.
Pin Configuration
32-Pin MLF® (MLF-32)
September 2006
3
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Pin Description
Pin Number
Pin Name
1, 3,
IN0, /IN0,
6, 8
IN1, /IN1
2, 7
VT0, VT1
Input Termination Center-Tap: Each side of the differential input pair terminates
to a VT pin. The VT0 and VT1 pins provide a center-tap to a termination network
for maximum interface flexibility. See the “Input Interface Applications” section
for more details.
31
SEL
This single-ended TTL/CMOS-compatible input selects the inputs to the
multiplexer. Note that this input is internally connected to a 25kΩ pull-up resistor
and will default to a logic HIGH state if left open. Input threshold is VCC/2.
9, 19, 22, 32
VCC
Positive Power Supply: Bypass with 0.1µF//0.01µF low ESR capacitors as close
to VCC pins as possible.
30, 28, 26, 24,
18, 16, 14, 12,
Q0 – Q7,
29, 27, 25, 23,
17, 15, 13, 11
20, 21
/Q0 – /Q7
GND,
Exposed Pad
10
CAP
4, 5
VREF-AC0
VREF-AC1
Pin Function
Differential Inputs: These input pairs are the differential signal inputs to the
device. These inputs accept AC or DC-coupled signals as small as 100mV
(200mVPP). Each pin of a pair internally terminates to a VT pin through 50Ω.
Please refer to the “Input Interface Applications” section for more details.
Differential Outputs: These LVDS output pairs are a logic function of the IN0,
IN1, and SEL inputs. Please refer to the truth table below for details. Unused
output pairs must be terminated with 100Ω across the pair.
Ground: Ground pin and exposed pad must be connected to the same ground
plane.
Power-On Reset (POR) Initialization capacitor. When using the multiplexer with
RPE capability, this pin is tied to a capacitor to VCC. The purpose is to ensure
the internal RPE logic starts up in a known state. See “Power-On Rest (POR)
Description” section for more details regarding capacitor selection. If this pin is
tied directly to VCC, the RPE function will be disabled and the multiplexer will
function as a normal multiplexer. The CAP pin should never be left open.
Reference Voltage: These outputs bias to VCC–1.2V. They are used for ACcoupling inputs (IN, /IN). Connect VREF_AC directly to the VT pin. Bypass with
0.01µF low ESR capacitor to VCC. See “Input Interface Applications” section.
Maximum sink/source current is ±1.5mA.
Truth Table
Inputs
September 2006
Outputs
IN0
/IN0
IN1
/IN1
SEL
Q
/Q
0
1
X
X
0
0
1
1
0
X
X
0
1
0
X
X
0
1
1
0
1
X
X
1
0
1
1
0
4
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Absolute Maximum Ratings(1)
Operating Ratings(2)
Supply Voltage (VCC) ...........................-0.5V to +4.0V
Input Voltage (VIN) .................................. -0.5V to VCC
Input Current
Source or sink current on IN, /IN.............. ±50mA
Termination Current
Source or sink current on VT .................. ±100mA
VREF-AC Source or sink current .......................... ±2mA
Lead Temperature (soldering, 20 sec.) ..........+260°C
Storage Temperature (Ts)..................–65°C to 150°C
Supply Voltage (VCC).................. +2.375V to +2.625V
Ambient Temperature (TA)................ –40°C to +85°C
Package Thermal Resistance(3)
MLF® (θJA)
Still-Air ..................................................... 35°C/W
MLF® (ψJB)
Junction-to-Board .................................... 16°C/W
DC Electrical Characteristics(4)
TA = –40°C to +85°C, unless otherwise stated.
Symbol
Parameter
VCC
Power Supply
ICC
Power Supply Current
RIN
Input Resistance
(IN-to-VT)
RDIFF_IN
Condition
Min
Typ
Max
Units
2.375
2.5
2.625
V
250
350
mA
45
50
55
Ω
Differential Input Resistance
(IN-to-/IN)
90
100
110
Ω
VIH
Input High Voltage
(IN, /IN)
1.2
VCC
V
VIL
Input Low Voltage
(IN, /IN)
0
VIH–0.2
V
VIN
Input Voltage Swing
(IN, /IN)
See Figure 1a. Note 5
0.2
VCC
V
VDIFF_IN
Differential Input Voltage Swing
|IN-/IN|
See Figure 1b.
VIN_FSI
Input Voltage Threshold that
Triggers FSI
VT_IN
IN-to-VT
(IN, /IN)
VREF-AC
Output Reference Voltage
No load, max. VCC
0.4
V
30
VCC–1.3
VCC–1.2
100
mV
1.8
V
VCC–1.1
V
Notes:
1.
Permanent device damage may occur if the absolute maximum ratings are exceeded. This is a stress rating only and functional operation
is not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratings
conditions for extended periods may affect device reliability.
2.
The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3.
Package Thermal Resistance assumes exposed pad is soldered (or equivalent) to the devices most negative potential on the PCB. θJA
and ψJB values are determined for a 4-layer board in still air, unless otherwise stated.
4.
The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established.
5.
VIN (max) is specified when VT is floating.
September 2006
5
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
LVDS Outputs DC Electrical Characteristics(6)
VCC = +2.5V ±5%; TA = –40°C to + 85°C; RL = 100Ω across output pair, or equivalent, unless otherwise stated.
Symbol
Parameter
Condition
Min
Typ
Max
Units
VOUT
Output Voltage Swing
(Q, /Q)
See Figure 1a and 4a
250
325
mV
VDIFF-OUT
Differential Output Voltage Swing
|Q - /Q|
See Figure 1b
500
650
mV
VOCM
Output Common Mode Voltage
See Figure 4b
1.125
1.275
V
∆VOCM
Change in Common Mode Voltage
See Figure 4b
–50
+50
mV
Max
Units
LVTTL/CMOS DC Electrical Characteristics(6)
VCC = +2.5V ±5%; TA = –40°C to + 85°C, unless otherwise stated.
Symbol
Parameter
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
Condition
Min
Typ
2.0
V
0.8
IIH
Input HIGH Current
–125
IIL
Input LOW Current
–300
30
V
µA
µA
Note:
1. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established.
September 2006
6
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
AC Electrical Characteristics(7)
VCC = +2.5V ±5%; TA = –40°C to +85°C, RPE enabled, Input tr/tf ≤ 600ps (20% to 80%), RL = 100Ω, unless otherwise stated.
Symbol
Parameter
Condition
Min
Typ
fMAX
Maximum Operating Frequency
RPE enabled
1.5
2.0
tpd
Differential Propagation Delay
IN-to-Q
VIN ≥ 250mV, Note 8
500
700
SEL-to-Q
RPE enabled, see Timing Diagram
SEL-to-Q
RPE disabled (VIN = VCC/2)
tpd
Tempco
Differential Propagation Delay
Temperature Coefficient
tskew
Output-to-Output Skew
Note 9
Part-to-Part Skew
tJitter
tR, tF
Max
GHz
950
ps
17
Cycles
1000
ps
fs/oC
115
40
ps
Note 10
200
ps
Random Jitter
Note 11
1
psRMS
Cycle-to-cycle Jitter
Note 12
1
psRMS
Total Jitter
Note 13
10
psPP
Crosstalk-Induced Jitter
Note 14
0.7
psRMS
Output Rise/Fall Time (20% to 80%)
At full output swing.
150
ps
Clock
20
Units
40
80
Notes:
1.
High-frequency AC-parameters are guaranteed by design and characterization.
2.
Propagation delay is a function of rise and fall time at IN. See “Typical Operating Characteristics” for more details.
3.
Output-to-output skew is measured between two different outputs under identical transitions.
4.
Part-to-part skew is defined for two parts with identical power supply voltages at the same temperature and with no skew of the edges at
the respective inputs.
5.
Random jitter is measured with a K28.7 character pattern, measured at <fMAX.
6.
Cycle-to-cycle jitter definition: the variation of periods between adjacent cycles, Tn – Tn-1 where T is the time between rising edges of the
output signal.
7.
Total Jitter definition: with an ideal clock input of frequency <fMAX, no more than one output edge in 10 output edges will deviate by
more than the specified peak-to-peak jitter value.
8.
Crosstalk is measured at the output while applying two similar differential clock frequencies that are asynchronous with respect to each
other at the inputs.
12
September 2006
7
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Functional Description
RPE and FSI Functionality
The basic operation of the RPE MUX and FSI
functionality is described with the following four case
descriptions. All descriptions are related to the true
inputs and outputs. The primary (or selected) clock
is called CLK1; the secondary (or alternate) clock is
called CLK2. Due to the totally asynchronous
relation of the IN and SEL signals and an additional
internal protection against metastability, the number
of pulses required for the operations described in
cases 1-4 can vary within certain limits. Refer to
“Timing Diagrams” for more detailed information.
RPE MUX and Fail-Safe Input
The SY89838U is optimized for clock switchover
applications where switching from one clock to
another clock without runt pulses (short cycles) is
required. It features two unique circuits:
Runt-Pulse Eliminator (RPE) Circuit:
The RPE MUX provides a “glitchless” switchover
between two clocks and prevents any runt pulses
from occurring during the switchover transition. The
design of both clock inputs is identical (i.e., the
switchover sequence and protection is symmetrical
for both input pair, IN0 or IN1. Thus, either input
pair may be defined as the primary input). If not
required, the RPE function can be permanently
disabled to allow the switchover between inputs to
occur immediately. If the CAP pin is tied directly to
VCC, the RPE function will be disabled and the
multiplexer will function as a normal multiplexer.
Case #1 Two Normal Clocks and RPE Enabled
In this case the frequency difference between the
two running clocks IN0 and IN1 must not be greater
than 1.5:1. For example, if the IN0 clock is 500MHz,
the IN1 clock must be within the range of 334MHz to
750MHz.
If the SEL input changes state to select the alternate
clock, the switchover from CLK1 to CLK2 will occur
in three stages.
Fail-Safe Input (FSI) Circuit:
The FSI function provides protection against a
selected input pair that drops below the minimum
amplitude requirement. If the selected input pair
drops sufficiently below the 100mV minimum singleended input amplitude limit (VIN), or 200mV
differentially (VDIFF_IN), the output will latch to the last
valid clock state.
• Stage 1: The output will continue to follow CLK1
for a limited number of pulses.
• Stage 2: The output will remain LOW for a limited
number of pulses of CLK2.
• Stage 3: The output follows CLK2.
Stage 2
Stage 1
Stage 3
CLK1
CLK2
SEL
Select CLK 1
Select CLK 2
OUTPUT
Runt pulse eliminated
from output
September 2006
4 to 5 falling edges of CLK2
3 to 5 falling edges
of CLK1
8
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
• Stage 1: The output will remain HIGH for a limited
number of pulses of CLK2.
• Stage 2: The output will switch to LOW and then
remain LOW for a limited number of falling edges
of CLK2.
Stage 3: The output will follow CLK2.
Case #2 Input Clock Failure: Switching from a
selected clock stuck HIGH to a valid clock (RPE
enabled)
If CLK1 fails HIGH before the RPE MUX selects
CLK2 (using the SEL pin), the switchover will occur
in three stages.
Stage 2
Stage 1
Stage 3
CLK1
CLK2
SEL
Select CLK 1
Select CLK 2
OUTPUT
Runt pulse eliminated
from output
Note:
14 to 16 falling edges of CLK2
Output shows extended clock cycle during switchover. Pulse width for both high and low of this cycle will
always be greater than 50% of the CLK2 period.
Case #3 Input Clock Failure: Switching from a
selected clock stuck Low to a valid clock (RPE
enabled)
If CLK1 fails LOW before the RPE MUX selects
CLK2 (using the SEL pin), the switchover will occur
in two stages.
•
Stage 1: The output will remain LOW for a
limited number of falling edges of CLK2.
•
Stage 2: The output will follow CLK2.
Stage 1
Stage 2
CLK1
CLK2
SEL
Select CLK 1
Select CLK 2
13 to 17 falling edges of CLK2
September 2006
9
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
If the selected input clock fails to a floating, static, or
extremely low signal swing, including 0mV, the FSI
function will eliminate any metastable condition and
guarantee a stable output signal. No ringing and no
undetermined state will occur at the output under
these conditions.
Please note that the FSI function will not prevent
duty cycle distortions or runt pulses in case of a
slowly deteriorating (but still toggling) input signal.
Due to the FSI function, the propagation delay will
depend on rise and fall time of the input signal and
on its amplitude. Refer to “Typical Operating
Characteristics” for more detailed information.
Case #4 Input Clock Failure: Switching from the
selected clock input stuck in an undetermined state
to a valid clock input (RPE enabled)
If CLK1 fails to an undetermined state (e.g.,
amplitude falls below the 100mV (VIN) minimum
single-ended input limit, or 200mV differentially)
before the RPE MUX selects CLK2 (using the SEL
pin), the switchover to the valid clock CLK2 will
occur either following Case #2 or Case #3,
depending on the last valid state at the CLK1.
CLK1
CLK2
SEL
Select CLK 1
Select CLK 2
OUTPUT
as in case #2
as in case #3
Power-On Reset (POR) Description
The following formula describes this relationship:
The SY89838U includes an internal power-on reset
(POR) function to ensure the RPE logic starts-up in
a known logic state once the power-supply voltage is
stable. An external capacitor connected between
VCC and the CAP pin (pin 10) controls the delay for
the power-on reset function.
Calculation of the required capacitor value is based
on the time the system power supply needs to power
up to a minimum of 2.3V. The time constant for the
internal power-on-reset must be greater than the
time required for the power supply to ramp up to a
minimum of 2.3V.
C(µF) ≥
t dPS ( ms )
12( ms / µF )
As an example, if the time required for the system
power supply to power up past 2.3V is 12ms, the
required capacitor value on pin 10 would be:
C(µF) ≥
12ms
12( ms / µF )
C(µF) ≥ 1µF
September 2006
10
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Typical Operating Characteristics
VCC = 2.5V, GND = 0V, VIN ≥ 250mVpk, tr/tf ≤ 300ps, RL = 100Ω across output pair; TA = 25°C, unless otherwise stated.
Propagation Delay Variation
vs. Input Rise/Fall Time
PROPAGATION DELAY (ps)
1000
700
600
400
300
200
100
0
0
100 200 300 400 500 600
INPUT RISE/FALL TIME (ps)
Propagation Delay Variation
vs. Input Rise/Fall Time
PROPAGATION DELAY (ps)
PROPAGATION DELAY (ps)
VIN = 200mVPK
1000
900
800
tpd (max)
700
600
tpd (min)
500
400
300
200
September 2006
tpd (min)
500
Propagation Delay Variation
vs. Input Rise/Fall Time
1000
100
0
tpd (max)
900
800
VIN = 400mVPK
0
100 200 300 400 500 600
INPUT RISE/FALL TIME (ps)
11
900
800
tpd (max)
700
600
tpd (min)
500
400
300
200
100
0
VIN = 800mVPK
0
100 200 300 400 500 600
INPUT RISE/FALL TIME (ps)
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Singled-Ended and Differential Swings
VDIFF_IN, VDIFF_OUT
700 mV (typical)
VIN, VOUT
350 mV (typical)
Figure 1a. Singled-Ended Voltage Swing
Figure1b. Differential Voltage Swing
Input Stage
Figure 2. Simplified Differential Input Stage
September 2006
12
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Input Interface Applications
option: may connect VT to VCC
Figure 3a. LVPECL Interface
(DC-Coupled)
Figure 3b. LVPECL Interface
(AC-coupled)
Figure 3d. CML Interface
(AC-Coupled)
Figure 3e. LVDS Interface
(DC-Coupled)
September 2006
13
Figure 3c. CML Interface
(DC-Coupled)
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
LVDS Output Interface Applications
LVDS specifies a small swing of 325mV typical, on a
nominal 1.2V common mode above ground. The
common mode voltage has tight limits to permit large
variations in ground between an LVDS driver and
receiver. Also, change in common mode voltage, as
a function of data input, is kept to a minimum, to
keep EMI low.
50Ω
VOUT
VOH, VOL
100Ω
±1%
50Ω
VOH, VOL
GND
VCOM
V∆COM
GND
Figure 4a. LVDS Differential Measurement
Figure 4b. LVDS Common Mode Measurement
Related Product and Support Documentation
Part Number
Function
Data Sheet Link
SY89837U
Presision 1:8 LVPECL Fanout Buffer with
2:1 Runt Pulse Eliminator Input Mux
www.micrel.com/_PDF/HBW/SY89837u.pdf
MLFTM Application Note
www.amkor.com/products/notes_papers/MLFAppNote.pdf
New Products and Applications
www.micrel.com/product-info/products/solutions.shtml
HBW Solutions
September 2006
14
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
Package Information
32-Pin (5mm x 5mm) MLF® (MLF-32)
September 2006
15
M9999-091906-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89838U
PCB Thermal Consideration for 32-Pin MLF® Package
(Always solder, or equivalent, the exposed pad to the PCB)
Package Notes:
1.
Package meets Level 2 qualification.
2.
All parts are dry-packaged before shipment.
3.
Exposed pads must be soldered to a ground for proper thermal management.
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http:/www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel
for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a
product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended
for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a
significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a
Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
September 2006
16
M9999-091906-B
[email protected] or (408) 955-1690