RHOMBUS-IND T

DESIGNED FOR SWITCHING
POWER SUPPLY APPLICATIONS
CURRENT SENSE
TRANSFORMERS
PRIMARY WINDING FURNISHED
PRIMARY PEAK SENSE CURRENT
20 AMPS OR GREATER
3750V RMS HI-POT
Electrical Specifications at 25OC
Secondary
Induct. min.
DCR
max.
Terminating
Resistance
( mH )
(Ω)
50
5.0
A
100
A
200
T-20103
A
T-20104
(Ω)
Pri. Unipolar
Amp-microsec.
Max. Rating
Pri. Bipolar
Amp-microsec.
Max. Rating
0.70
50
150
300
20.0
1.40
100
300
600
80.0
4.70
200
600
1200
300
180.0
11.00
300
900
1800
B
50CT
5.0
0.70
50
150
300
T-20105
B
100CT
20.0
1.40
100
300
600
T-20106
B
200CT
80.0
4.50
200
600
1200
T-20107
B
300CT
180.0
11.00
300
900
1800
Schematic
Style
Secondary
Turns
T-20100
A
T-20101
T-20102
Part Number
Maximum ratings specified with rated secondary
terminating resistance and 1 turn.
Amp-µsec rating of primary equals volt-µsec rating
of secondary when secondary is terminated into
rated resistance.
Physical Dimensions
inches (mm)
Maximum operating temperature 1050 C.
For further details refer to data sheets
STYLE "A"
SCHEMATIC
1
3
PRI
SEC
2
5
STYLE "B"
SCHEMATIC
3
1
PRI
PRIMARY Leads: 16AWG
SEC
4
2
SECONDARY Leads: 20AWG
5
Specifications are subject to change without notice
Rhombus
Industries Inc.
Transformers & Magnetic Products