NOTICES 1. The contents stated in this document and the product may be subject to change without prior notice. When you kindly study to use this product, please ask us or our distributor for the latest information. 2. This product is developed and produced for usage onto normal electronic products (office automation equipments, communication peripherals, electric appliance products, game machines, etc.) and is not suitable for applications which need extremely high reliability and extreme safety (aero- or space-use machines, control equipments for nuclear power, life keeping equipments, etc.). 3. This document shall not grant or guarantee any right to adapt intellectual property or any other patents of third party. 4. Please use this product correctly according to operating conditions and precautions for use stated in this document. Please install safety proof in your designing to avoid human accident, fire accident and social damage, which may be resulted from malfunction of this product. 5. This product is not designed to withstand against radiant rays. 6. It is strictly prohibited to copy or publish a part or whole of this document without our prior written approval. REVISION HISTORY DATE REVISION NO. PAGE July.2,01 Ver. 1 - DESCRIPTIONS Initial Release. Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 1/13 MECHANICAL CHARACTERISTICS ITEM LCD module size Resolution Sub pixel pitch Pixel pitch Active viewing area Bezel opening area Weight Tottori SANYO Electric Co., Ltd. SPECIFICATION 331.6(W) ×254.75(H) ×29.5(T) 1024 × RGB(W) × 768(H) 0.099(W) × 0.297(H) 0.297(W) × 0.297(H) 304.1(W) × 228.1(H) 307.2(W) × 231.1(H) (1900)TYP. TM150XG-26L07 Ta=25 °C UNIT mm pixel mm mm mm mm g Ver.1 Page 2/13 OPTICAL CHARACTERISTICS Ta=25ºC, VDD=3.3V, fV =60Hz MIN TYP MAX UNIT NOTE 2 TBD (250) cd/m Note 5,8 TBD Note 5,6,8 (300) Note 2,4,8 (55) (60) Note 1,2, deg. 4,8 (50) (60) (20) ms. Note 3,4,8 (5) TBD TBD TBD TBD Note 4,8 TBD TBD TBD TBD - ITEM SYMBOL CONDITIONS Brightness B φ = 0º Brightness uniformity φ = 0º Contrast ratio CR φ = 0º θ = 0º θ = 90º Viewing angle range φ CR>10 θ =180º θ =270º Response Rise tr φ = 0º time Fall tf x Red y x Green y Color of CIE φ = 0º Coordinate x Blue y x White y θ=180° φ DATA Black White Black 100% θ=90° θ=270° B 90% 10% 0% tr θ tf θ=0° [ Note 1 ] φ and θ [ Note 3 ] Response time [ Note 2 ] Contrast ratio "CR" Brightness at White CR = Brightness at Black [ Note 4 ] This shall be measured at center point No.3 of Note 7. [ Note 5 ] The brightness shall be the average of the following 5 points of Note 7. [ Note 6 ] The brightness uniformity shall be calculated by using following formula. Maximum brightness of 5 points Brightness uniformity = Minimum brightness of 5 points Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 3/13 [ Note 7 ] Measurement points 1/6Hp 1/2Hp 5/6Hp Active area 1/6Vp 1 1/2Vp 2 3 5/6Vp 4 5 Vp: Total Number of Vertical pixel Hp: Total Number of horizontal pixel [ Note 8 ] Measurement condition (1) Measurement equipment: BM-5A (TOPCON Corp.), Field=2° (2) Ambient temperature Ta: 25 ± 2°C (3) LCD: All pixels are WHITE, VDD=3.3V, fV=60Hz (4) Measure after 30 minutes of CFL warm up. (5) IL=TBDmArms BACKLIGHT CHARACTERISTICS This module is used the backlight with 2 CFL. Please follow the characteristics of 1 CFL as below. ITEM Operating life Lamp current SYM. CONDITIOS tOL IL Tottori SANYO Electric Co., Ltd. MIN (50000) (3) TYP - MAX (8) UNIT Hours mArms TM150XG-26L07 Ta=25°C NOTE at IL= TBD (Recommended value) Ver.1 Page 4/13 BLOCK DIAGRAM 1024 × (RGB) ×768 Inverter DATA INPUT I/O Even RGB x 8 bit Odd RGB x 8 bit LCD Controller Scaler POWER DC/DC Converter Gate Driver TFT Timing Controller DATA INPUT CN1 Analog(D-sub) (15pin) CFL TFT-LCD Panel Odd RGB 6bit Even RGB 6 bit CFL Source Driver Back Light CN2 Digital(DVI-D) (24pin) Tottori SANYO Electric Co., Ltd. CN3 Key Control (12Pin) TM150XG-26L07 CN4 Power jack (12V) Ver.1 Page 5/13 INTERFACE PIN CONNECTIONS CN1 15PIN Analog RGB Interface CONECTOR : KSEY-15S-1A3F-19-13 PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SYMBOL RED GREEN BLUE ID2(GND) ST(GND) RED GND GREEN GND BLUE GND NC DIGITAL GND IDO(GND) SDA H-SYNC V-SYNC SCL FUNCTION DATA DATA DATA GND GND GND GND GND NO CONNECTION GND GND BIDIRECTIONAL DATA HORIZONTAL SYNC VERTICAL SYNC DATA CLK 1PIN Screen side is faced CN 1 5PIN toward the bottom and top view. 10PIN 6PIN 11PIN 15PIN CN2 24PIN Digital Interface Connector : SD-7432 (MOLEX) PIN SYMBOL DESCRIPTION 1 RX2TMDS Negative differential input, channel 2 2 RX2+ TMDS Positive differential input, channel 2 3 GND GND 4 NC NC 5 NC NC 6 SCL CLOCK 7 SDA Data 8 NC NC 9 RC1TMDS Data 110 RX1+ TMDS Data 1+ 11 GND GND 12 NC NC 13 NC NC 14 +5V +5V Power 15 GND Grond (Return for +5V,Hsync,and V Sync) 16 HP Hot Plug 17 RX0TMDS Date 018 RX0+ TMDS Date 0+ 19 GND GND 20 NC NC 21 NC NC 22 GND GND 23 RX CLK + TMDS Clock + 24 RX CLKTMDS Clock - Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 6/13 CN 2 1PIN 8PIN 16PIN Screen side is faced toward the bottom and top view. 9PIN 17PIN 24PIN CN3 DC Power jack DC power jack (CN3) : HEC4801 (HOSIDEN) DC POWER JACK (CN3) PIN COFIGURATION No 1 Symbol Vcc (12V) Notes 2 GND 1 CN 3 1 2 1PIN φ5 Screen side is faced toward the bottom and φ 5.5 2PIN Description top view. CN4 Key Control PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 1 PIN Recommend Plug 4 Connector : 53261-1210 (MOLEX) SYNBOL VDD LED-G LED-O KEY-U KEY-D KEY-R KEY-L LCD ON/OFF RST BKA GND GND FUNCTION +5V LED GREEN LED ORANGE KEY UP KEY DOWN KEY RIGHT KEY LEFT LCD ON/OFF REST BKLT ADJ GND GND CN 4 12 PIN Screen side is faced toward the bottom and top view. Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 7/13 RECAUTIONS (INSTRUCTIONS FOR SAFE AND PROPER USE) 1. Instructions for safety (1) Please do not disassemble or modify LCD module to avoid the possibility of electric shock, damage of electronic components, scratch at display surface and invasion of foreign particles. In addition, such activity may result in fire accident due to burning of electronic component. LCD module disassembled or modified by customer is out of warranty. (2) Please be careful in handling of LCD module with broken glass. When the display glass breaks, please pay attention not to injure your fingers. The display surface has the plastic film attached, which prevents dispersion of glass pieces, however touching broken edge will injure your fingers. Also CFL (Cold Cathode Fluorescent Lamp) is made of glass, therefore please pay attention in the same way. (3) Please do not touch the fluid flown out of broken display glass. If the fluid should stick to hand or clothes, wipe off with soap or alcohol immediately and then wash it with water. If the fluid should get in eyes, wash eyes immediately with washing lotion for more than 15 minutes and then consult the doctor. (4) Please make secure connection of CFL connector. Please make sure that CFL connector from LCD module is connected with output connector on inverter circuit securely. Poor connection may cause smoke or fire accident due to high voltage in circuit. If connection may not be secure, please switch off the power supply for LCD module and CFL and then make secure connection. Please do not make connection with another connector than recommended mating connector. (5) CFL contains mercury inside. Please follow regulations or rules established by local autonomy at its disposal. (6) Please be careful to electric shock. Before handling LCD module, please switch off the power supply. Since high voltage is applied to CFL terminal, cable, connector and inverter circuit in operation mode, touching them will cause electric shock. 2. Instructions for designing (1) Mounting of LCD Please fix LCD module at all mounting flanges shown in this specification for installation onto system. The used screws should have proper dimensions. Furthermore, designing of mounting parts should be adequate so that LCD module is not warped or twisted, to achieve good display quality. (2) Heat radiation CFL generates heat at lighting and causes temperature rise inside system. Therefore, designing to radiate heat like radiation slits at cabinet is recommended to meet the specified operating temperature range for LCD module. (3) Noise on power line Spike noise contained in power line causes abnormal operation of driving circuit and abnormal display. To avoid it, spike noise should be suppressed below VDD ± 200mVp-p. (In any case, absolute maximum rating should be kept.) Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 8/13 (4) Power sequence Before LCD module is switched on, please make sure that power supply and input signals of system, testing equipment, etc. meet the recommended power sequence. (5) Absolute maximum rating Absolute maximum rating specified in this specification has to be kept in any case. It shows the maximum that cannot be exceeded. Exceeding it may cause burning or non-recoverable break of electronic components in circuit. Please make system design so that absolute maximum rating is not exceeded even if ambient temperature, input signal and components are varied. (6) Protection for power supply Please study to adapt protection for power supply against trouble of LCD module, depending on usage condition of system. Fuse installed on LCD module should be never modified. Any modification to make the function of fuse ineffective may cause burning or break of printed wiring board or other components at circuit trouble. (7) Protection against electric shock High voltage is applied to CFL connector, inverter circuit and CFL at lighting. Please make design not to expose or be accessible to such high voltage parts to avoid electric shock. (8) Protection cover and cut-off filter for ultraviolet rays When LCD module is used under severe condition like outdoor, it is recommended to use transparent protection cover over display surface to avoid scratches and invasion of dust and water. In addition, when LCD module is exposed to direct sun light for long time, use of cut-off filter for ultraviolet rays is also recommended. Please be careful not to get condensation. 3. Instructions for use and handling (1) Protection against Static electricity C-MOS LSI and semiconductors are easily damaged by static discharge. LCD module should be handled on conductive mat by person grounded with wrist strap etc. to avoid getting static electricity. Please be careful not to generate static electricity during operation. (2) Protection against dust and stain LCD module should be handled in circumstance as clean as possible. It is recommended to wear fingerstalls or ductless and soft gloves before handling to avoid getting dust or stain on display surface. (3) Protection film for display surface It is recommended to remove protection film at nearly final process of assembling to avoid getting scratch or dust. To remove film, please pick up its edge with dullhead tweezers or cellophane tape at first and then remove film gradually taking more than 3 seconds. If film is removed quickly, static electricity may be generated and may damage semiconductors or electronic components. (4) Contamination of display surface When display surface of LCD module is contaminated, please wipe the surface softly with cotton swab or clean cloth. If it is not enough, please take it away with cellophane tape or wipe the surface with cotton swab or clean cloth containing benzine. In this case, please be careful so that benzine does not get in inside of LCD module, because it may be damaged. Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 9/13 (5) Water drop on LCD surface Please do not leave LCD module with water drop. When the display surface gets water drop, please wipe it off with cotton swab or soft cloth immediately, otherwise display surface will be deteriorated. If water gets in inside of LCD module, circuit may be damaged. (6) Please make sure that LCD module is not warped or twisted at installation into system. Even temporary warp or twist may be the cause for failure. (7) Mechanical stress Please be careful not to apply strong mechanical stress like drop or shock to LCD module. Such stress may cause break of display glass and CFL or may be the cause for failure. (8) Pressure to display surface Please be careful not to apply strong pressure to display surface. Such pressure may cause scratches at surface or may be the cause of failure. (9) Protection against scratch Please be careful not to hit, press or rub the display surface with hard material like tools. In addition, please do not put heavy or hard material on display surface, and do not stack LCD modules. Polarizer at front surface can be easily scratched. (10) Plugging in of connector Please be careful not to apply strong stress to connector part of LCD module at plugging in or out, because strong stress may damage the inside connection. At plugging in connector, place LCD module on the flat surface and hold the backside of connector on LCD module. Please make sure that connector is plugged in correctly. Insecure connection may be the cause for failure during operation. In addition, please be careful not to put the connecting cable between cabinet of system and LCD module at installing LCD module into system. (11) Handling of CFL cable and FPC (Flexible Printed Circuit) Please be careful not to pull or scratch CFL cable, because CFL or soldered part of cable may be damaged consequently. Also FPC should not be pulled or scratched. (12) Switching off before plugging in connector Please make sure that power is switched off before plugging in connector. If power is on at plugging in or out, circuit of LCD module may be damaged. When LCD is switched on for test or inspection, please make sure that power supply and input signals of driving system meet the specified power sequence. (13) Temperature dependence of LCD display Response speed (optical response) of LCD display is dependent on temperature. Under low temperature, response speed is slower. Also brightness and chromaticity change slightly depending on temperature. (14) Slow light-up of CFL under low temperature Under low temperature, start-up of CFL gets difficult. (The time from switch-on to stable lighting becomes longer.) As characteristic of CFL, operation under low temperature makes the life time shorter. To avoid this, it is recommended to operate under normal temperature (15) Condensation LCD module may get condensation on its display surface and inside in the circumstance where temperature changes much in short time. Condensation can cause deterioration or failure. Therefore, please be careful not to get condensation. Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 10/13 . (16) Remaining of image Displaying the same pattern for long time may cause remaining of image even after changing the pattern. This is not failure but will disappear with time. 4. Instructions for storage and transportation (1) Storage Please store LCD module in the dark place of room temperature and low humidity in original packing condition, to avoid condensation that may cause failure. Since sudden temperature change may cause condensation, please store in circumstance of stable temperature. (2) Stacking number Since excessive weight causes deformation and damage of carton box, please stack only up to the number stated on carton box for storage and transportation. (3) Handling Since LCD module consists of glass and precise electronic components, it will be damaged by excessive shock and drop. Therefore, please handle the carton box carefully to minimize shock at loading, reloading and transportation. Tottori SANYO Electric Co., Ltd. TM150XG-26L07 Ver.1 Page 11/13 WWW.ALLDATASHEET.COM Copyright © Each Manufacturing Company. All Datasheets cannot be modified without permission. This datasheet has been download from : www.AllDataSheet.com 100% Free DataSheet Search Site. Free Download. No Register. Fast Search System. www.AllDataSheet.com