MA-COM 3EXLA2S

CORCOM Product Guide
Multi-Function Power Entry Modules with RFI Power Line Filters
LA Series
UL Recognized
CSA Certified
VDE Approved
FLA/XLA/ZLA
LA Series
Specifications
The LA series is a multi-function power entry connector with
a choice of filtering capabilities. The series features an IEC
power line connector, selectable North American or dual
European fusing capabilities, DPST on/off switch, and
120/240 voltage selection. The filtered LA units provide a
one piece solution to power entry needs and provide a
filtering solution for almost any RFI problem. Their vertical
design is flange mounted.
Maximum leakage current, each line-to-ground:
@ 120 VAC 60 Hz:
FLA Model
0.25 mA
XLA/ZLA Models 0.30 mA
This series offers three levels of filtering, all carrying UL
recognition, CSA certification, and VDE approval.
FLA Model – General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of
line-to-ground noise.
XLA Model – High performance RFI filter designed to bring
most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits.
ZLA Model – Premium performance RFI filter designed to
bring most digital equipment (including switching power
supplies) into compliance with EN55022, Level B (as well
as FCC Part 15J, Class B) conducted emissions limits.
Voltage Selection
To change selected voltage: remove the fuse cartridge
using a small blade screwdriver or similar tool; select the
desired voltage by matching the arrow on the fuse cartridge to the arrow located on the front of the unit (lower
right corner); replace the fuse cartridge making sure the
voltage selection arrow aligns with the arrow located on
the front of the unit.
Fuse Changing
Remove the fuse cartridge using a small blade screwdriver
or similar tool; for European fusing pull out the sliding fuse
covers located at the top of each fuse compartment; insert
desired fuses; push the sliding fuse covers back in place
and insert the fuse cartridge back into the unit making sure
the voltage selection arrow aligns with the arrow located on
the front of the unit. (Note: Single North American or
European fuse placement is always on the side of the
desired voltage selection arrow behind the fuse symbol;
the other compartment may be used as a spare or be left
blank. Dual European fusing capability is available for
220/240 volts only.)
@ 250 VAC 50 Hz:
All Models
Hipot rating (one minute):
line-to-ground
line-to-line
0.50 mA
1500 VAC
1450 VDC
Operating voltages:
110,120, 220/240 VAC
Operating frequency:
50/60 Hz
Rated voltage (max.):
250 VAC
Switch:
Double-insulated, rated for
50,000 operations at full load.
35 Amp inrush capability
Fuse (not included):
Accepts one 1/4" x 1-1/4" fuse,
or two 5 x 20 mm fuses
Terminals:
.110 [2.79] terminals
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating
.01 .05 .15
.5
1
5
FLA
5A
14
21
26
40
XLA
3A
2
12 21
35
46
44
ZLA
3A
14
28 38
42
40
40
10
30
46
50
44
40
40
40
10
30
Line-to-line in 50 ohm circuit
Current
Rating
XLA
3A
ZLA
3A
Frequency-MHz
.02 .03 .05 .07 .15 .5 1 5
-
-
-
5
33
60 65 60 50
50
3
14
29
38
57
72 72 65 55
50
122
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
Multi-Function Power Entry Modules with RFI Power Line Filters (Continued)
LA Series
Case Style
Case Dimensions
FLA, XLA & ZLA
Part No.
A
F
5EFLA2S
B
3EXLA2S
D
C
3EZLA2S
A
(max)
1.99
50.5
1.99
50.5
1.99
50.5
B
±0.15
±0.381
1.57
39.9
1.57
39.9
1.57
39.9
C
(max)
D
E
F
(max) (max) (max)
2.59
65.79
2.59
65.79
2.59
65.79
2.41
61.21
2.41
61.21
2.41
61.21
3.16
1.18
68.07 29.97
4.16
1.18
105.7 29.97
4.16
1.18
105.7 29.97
Power Entry Modules
220-240
110-120
Recommended Panel Cutout
FL, XLA & ZLA
.093 R
2.36
.140 Dia. (2)
3.56
E
Typical dimensions:
Terminals: .110 [4.80]
Holes: .059 [1.5] Dia. Max., except solder lug ground tap with wire wrap.
Mounting Holes: .142 [3.6] Dia. (2)
1.19*
30.23
* +.020 - .00
+ 0.5 - .00
Electrical Schematics
FLA
2.42*
61.47
1.57
39.88
A B C
120V
Power on/off
D
E
F
240V
A or D
A
A
B
B
120V
Part Numbers
Neutral
C
Ground
D
D
E
E
Note: All models allow front mounting only.
0
F
Phase
F
120V
5EFLA2S
3EXLA2S
3EZLA2S
G
Customer
Transformer
Primaries
XLA & ZLA
A B C
120V
On/Off
Neutral
D
E
F
240V
A or D
A
A
B
B
120V
C
Hot
D
D
E
E
F
F
G
120V
Customer
Transformer
Primaries
Note: Provision for dual European fusing by connection to "A".
Resistor location for reference only.
123
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com