Data Sheet 45 300V Input Mini Family * DC-DC Converter Module Features • • • • • • • • • • • DC input range: 180 - 375V Input surge withstand: 400V for 100ms DC output: 2V - 48V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: Up to 89% Maximum operating temperature: 100°C at full load Power density: Up to 100W/cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Typical Applications: off-line systems, distributed power and electric vehicles Product Overview This DC-DC converter module uses 2nd Generation power processing, control and packaging technologies to provide the performance, flexibility and cost effectiveness expected of a mature power component. For example, a plated-cavity core transformer couples widely separated primary and secondary windings, resulting in low in-toout parasitic capacitance and noise. High frequency ZCS/ZVS switching, advanced power semiconductor packaging and thermal management provide high power density with low temperature gradients. Extensive use of silicon integration results in 1/3 the part count of a 1st Generation converter. Part Numbering V 300 B 15 C 250 A Input Voltage 24 = 24Vin 48 = 48Vin 300 = 300Vin 375 = 375Vin A = Maxi B = Mini C = Micro Output Voltage Output Power Pin Style Product Grade Temperatures (°C) Grade Storage Operating C = - 40 to +125 - 20 to +100 T = - 40 to +125 - 40 to +100 H = - 55 to +125 - 40 to +100 M = - 65 to +125 - 55 to +100 Baseplate For pin styles see page 6. Slotted baseplate (style 1) requires no designator. For threaded baseplate add a “2” to the end of the part number. For thru-hole, add a “3”. See page 7 for dimensions. Absolute Maximum Ratings Parameter Rating Unit +In to –In voltage -0.5 to +375 Vdc +In to –In voltage 400 Vdc PC to –In voltage -0.5 to +7.0 Vdc PR to –In voltage -0.5 to +7.0 Vdc SC to –Out voltage -0.5 to +1.5 Vdc 1.0 Vdc –Sense to –Out voltage Isolation voltage (in to out) 3000 Vrms Isolation voltage (in to base) 1550 Vrms Isolation voltage (out to base) Notes <100ms 500 Vrms Storage temperature -40 to +125 °C C-Grade Operating temperature C-Grade -20 to +100 °C Pin soldering temperature 500 (260) °F (°C) Pin soldering temperature 750 (390) °F (°C) 5 (0.57) in-lbs (N-m) Mounting torque <5 sec; wave solder <7 sec; hand solder 6 each, # 4-40 or M3 Thermal Resistance and Capacity Parameter Min Typ Max Unit Baseplate to sink; flat, greased surface 0.16 °C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.14 °C/Watt Baseplate to ambient 8.0 °C/Watt Baseplate to ambient; 1000 LFM 1.9 °C/Watt Thermal capacity 83 Watt-sec/°C * The modules described here are the highest power for each output voltage. Consult factory for availability of lower power units. Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 1 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com ELECTRICAL CHARACTERISTICS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. MODULE OPERATING SPECIFICATIONS Parameter Min Typ Max Unit Notes Operating input voltage 180 300 375 Vdc Input surge withstand 400 Vdc Output voltage setpoint ±1 % Vout nom. <100ms Nominal input; full load; 25°C MODULE OUTPUT VOLTAGE RELATED SPECIFICATIONS Parameter 1.8V 1 2V 2.5V 2 3.3V 5V 12V 15V 24V 28V 48V Unit Efficiency (typ.) 70.4 71.0 74.7 Ripple and noise, p-p (typ.) 120 120 Output power (max.) 90 Output OVP setpoint (nom.) Notes 77.5 81.5 85.0 86.5 87.5 88.0 89.0 % Nominal input; 80% load; 25°C 120 120 80 150 160 115 110 70 mV Nominal input; full load; 25°C; 20MHz BW 100 114 150 200 250 250 250 250 250 Watts At 100°C baseplate temp 2.8 2.8 4.3 4.3 6.3 14.3 17.8 28.1 32.7 55.7 Volts 25°C; recycle input voltage to restart ( 1 minute off ) Dissipation, standby (typ.) 3.9 3.9 4.6 4.6 4.2 4.0 5.5 4.3 5.6 4.2 Watts No load; nominal input Load regulation (max.) 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 ±% Vout Current limit (typ.) 115 115 115 115 115 115 115 115 115 115 % Iout Output voltage 95% of nominal Short circuit current (typ.) 115 115 115 115 115 115 115 115 115 115 % Iout Output voltage <250mV No load to full load; nominal input MODULE INPUT SPECIFICATIONS Parameter Min Undervoltage turn-on Undervoltage turn-off 147.4 Typ Max Unit 174.6 178.2 Vdc 152.8 Notes Vdc Overvoltage turn-off/on Vdc Not included Notes MODULE OUTPUT SPECIFICATIONS Parameter Typ Max Unit Line regulation ±0.02 ±0.20 % Temperature regulation ±0.002 ±0.005 % / °C Power sharing accuracy ±2 ±5 % 10 to 100% of full load 110 % Of nominal output voltage. For trimming below 90% of nominal, a minimum load of 10% of maximum rated power may be required. Programming range Min 10 Low line to high line; full load Over operating temperature range Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474. 1 2 Nominal 2V output trimmed to 1.8V by adding external 9,000 ohm resistor from the SC pin to -S pin. (See Fig. 7) Nominal 3.3V output trimmed to 2.5V by adding external 3,125 ohm resistor from the SC pin to -S pin. (See Fig. 7) Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 2 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com ELECTRICAL CHARACTERISTICS, continued MODULE CONTROL SPECIFICATIONS Parameter Min Typ Max Unit Notes PRIMARY SIDE (PC = Primary Control; PR = Parallel) PC bias voltage current limit 5.50 1.5 5.75 2.1 6.00 3.0 Vdc mA PC current = 1.0 mA PC voltage = 5.5V PC module disable 2.3 2.6 2.9 Vdc Must be able to sink ≥4 mA. See Fig. 1 4 7 ms 0.5 Vavg UV, OV, OT, module fault. See Figs. 2 and 4 6.1 Volts PR load >30 ohms, < 30 pF PC module enable delay PC module alarm PR emitter amplitude 5.7 5.9 PR emitter current 150 PR receiver impedance 375 500 625 ohms 25°C PR receiver threshold 2.4 2.5 2.6 Volts Minimum pulse width: 20ns 12 modules Without PR buffer amplifier mA PR drive capability SECONDARY SIDE (SC = Secondary Control) SC bandgap voltage 1.21 1.23 1.25 Vdc SC resistance 990 1000 1010 ohms SC capacitance SC module alarm Referenced to –Sense 0.033 µF 0 Vdc With open trim; referenced to –Sense. See Fig. 6 Max Unit Notes 0.5 Vdc 0.25V per leg (senses must be closed) MODULE GENERAL SPECIFICATIONS Parameter Min Typ Remote sense (total drop) Isolation voltage (in to out) 3000 Vrms Complies with reinforced insulation requirements Isolation voltage (in to base) 1550 Vrms Complies with basic insulation requirements Isolation voltage (out to base) 500 Vrms Complies with operational insulation requirements Isolation resistance (in to out) 10 Weight Temperature limiting Agency Approvals 3.7 (104) 100 megohms 4 (112) ounces (grams) 115 UL, CSA, TÜV, BABT, CE, VDE °C See Figs. 2 and 4 UL1950, CSA950, EN60950, VDE0805, BS7002, IEC 60950. With a fuse in series with the +Input Note: Specifications are subject to change without notice. The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com. Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 3 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com CONTROL FUNCTIONS - PC PIN Module Enable/Disable Module Alarm The module may be disabled by pulling PC below 2.3V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 1. The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parameters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, overtemperature) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 2 and 4. Primary Auxiliary Supply At 5.7V, PC can source up to 1.5mA. In the example shown in Figure 3, PC powers a module enabled LED. +In +In +Out SW1 +S PC PR 2-20ms typ. f (VIN) SW3 1K SC –S 5.7 Vdc (0-3mA) –In –Out SW2 +Out +S 50Ω SW1, 2, & 3 shown in "Fault" position PR –S –In Auto Restart PC SC Disable Input Undervoltage Input Overvoltage Overtemperature Module Faults 1.23 Vdc 6K –Out Disable = PC <2.3V Figure 1—Module enable/disable. Figure 2—PC/SC module alarm logic. +In +Out PC "Module Enabled" Fault +S PC 40µs typ. 5.7V SC 4kΩ PR –S –In –Out SC Figure 3—LED on-state indicator. Optocoupler 4kW Figure 5—Isolated on-state indicator. 1.23V 2-20ms typ. Figure 4—PC/SC module alarm timing. +In +Out +In PC +S PC +Out +S SC SC PR –S PR –S –In –Out –In –Out Alarm 1.00V Figure 6—Secondary side on-state indicator. Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 4 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com CONTROL FUNCTIONS - SC PIN Output Voltage Programming The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figures 7 and 8. +Out +Out +S +S Error Amp SC –S 1kΩ 0.033 µF RD Trim Down Error Amp Load SC RU Trim Up Load –S 1kΩ 0.033 µF –Out –Out 1.23V 1.23V RD (ohms) = 1,000 Vout Vnom - Vout RU (ohms) = 1,000 (Vout-1.23) Vnom 1.23 (Vout-Vnom) –1,000 Figure 7—Output voltage trim down circuit. Figure 8—Output voltage trim up circuit. Trim Down Trim Up 1. This converter is not a constant power device – it has a constant current limit. Hence, available output power is reduced by the same percentage that output voltage is trimmed down. Do not exceed maximum rated output current. 1. The converter is rated for a maximum delivered power. To ensure that maximum rated power is not exceeded, reduce maximum output current by the same percentage increase in output voltage. 2. The trim down resistor must be connected to the –Sense pin. 2. The trim up resistor must be connected to the +Sense pin. 3. Do not trim the converter above maximum trim range (typically +10%) or the output over voltage protection circuitry may be activated. Trim values calculated automatically: Resistor trim calculators are available on Vicor’s web site at URL: www.vicorpower.com/ tools.html or by requesting a copy of Vicor’s Applications Manual on a CD ROM. Resistor values can be calculated for fixed trim up, fixed trim down and for variable trim up or down cases for both 1st and 2nd Generation DC-DC converters. In addition to trimming information, the web site and the applications manual on CD ROM also include design tips, applications circuits, EMC suggestions, thermal design guidelines and PDF data sheets for all available Vicor products. Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 5 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com CONTROL FUNCTIONS - PR PIN Parallel Operation The PR pin supports paralleling for increased power with N+1 (N+M) redundancy and phased array capability. Modules of the same input voltage, output voltage, and power level will current share if all PR pins are suitably interfaced. Compatible interface architectures include the following: DC coupled single-wire interface. All PR pins are directly connected to one another. This interface supports current +Out +In PC +S PC Module 1 0.001µF SC PR –In –Out +In +Out +In +Out +S PC 0.001µF SC Module 2 PR –In +In Module N+1 PC PR –In +Out +S SC –S –Out SC –S PR –S –Out –In –Out Ground plane Figure 10—AC coupled single-wire interface. • The +Out and –Out power buses should be designed to minimize and balance parasitic impedance from each module output to the load. +S –S +S Load –S –S +Out +S SC –S –Out +S Module 2 (up to 12) –In +S +In PC –S PR Figure 9—DC coupled single-wire interface. PR –In SC –S Ground plane PC +S Module 1 –Out Module 2 (up to 12) Module 1 +Out –In PC +Out +S SC –S –Out AC coupled single-wire interface. All PR pins are connected to a single communication bus through 0.001µF (500V) capacitors. This interface supports current sharing and is fault tolerant except for the communication bus. See Figure 10. +In PR +In sharing but is not fault tolerant. Minus In pins must be tied to the same electric potential. See Figure 9. +In • The +Sense pins should be tied to the same point on the +Out power bus; the –Sense pins should be tied to the same point on the –Out power bus. +Out +S PC SC PR • At the discretion of the power system designer, a subset of all modules within an array may be configured as slaves by shorting SC to –S. –In –S –Out • OR’ing diodes may be inserted in series with the +Out pins of each module to provide module output fault tolerance. Figure 11—N+1 module array output connections. +Sense from other modules in the array Figure 12—OR’ing diodes connections. PIN STYLES * Designator Description Notes (None) Short solder Requires in-board, mounting L Long solder On-board mounting for 0.65" boards S Short ModuMate SurfMate or in-board socket mounting N Long ModuMate On-board socket mounting * Pin style designator follows the “A” after the output power and precedes the baseplate designator. Ex. V375A24C600AN — Long ModuMate Pins Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 Page 6 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com MECHANICAL DRAWINGS MODULE OUTLINE No. 1 2 3 4 5 6 8 9 –Sense 0.50 ±0.02 12,7 ±0,5 2.20 55,9 1.74 44,2 0.23 (REF) 5,8 0.01 style 2 & 3 baseplates only (4X)*** 0.300 ±0.015 7,62 ±0,38 2.000 0.49 12,4 0.12* 0.20** 3,1 5,1 0.10 2,5 50,80 0.10 X 45˚ 2,5 CHAMFER –S Secondary Control +Sense +Out 1 0.300 ±0.015 SC 2 3 4 0.35 (2X) 8,8 (ALL MARKINGS THIS SURFACE) 7 Converter Pins Function Label +In + Primary PC Control Parallel PR –In – –Out – 7,62 ±0,38 +S + 1.900 48,26 ALUMINUM BASEPLATE 2.28 1.30 57,9 33,0 0.65 16,5 FULL R (6X) 0.130 3,30 9 PINS: TIN/LEAD HOT SOLDER DIP 8 7 6 0.150 DIA,(2X) 3,81 0.080 DIA,(7X) 2,03 0.400 10,16 0.43 10,9 0.700 17,78 1.000 25,40 1.400 35,56 Slotted (Style 1) or (6X) 5 0.06 R (3X) 1,5 0.54 (9X) 13,7 Pin Style 1 0.62 (9X) 15,7 Pin Style 2 Use a 4-40 Screw (6X) Torque to: 5 in-lbs .57 N-m 2.20 55,9 (REF.) (Short Pin) (Long Pin) Threaded (Style 2) 4-40 UNC-2B (6X) or Thru Hole (Style 3) ALL MARKINGS THIS SURFACE * Style 1 baseplate only ** Style 2 & 3 baseplates *** Reserved for Vicor accessories #30 Drill Thru (6X) (0.1285) PCB MOUNTING SPECIFICATIONS PCB THICKNESS R 0.062 ±0.010 1,57 ±0,25 PLATED THRU HOLE DIA 1.790 45,47 0.06 (4X) 1,5 ONBOARD SOLDER MOUNT PIN STYLE 1 PIN STYLE 2 (7X) 0.094 ±0.003 2,39 ±0,08 0.094 ±0.003 2,39 ±0,08 (2X) 0.164 ±0.003 4,16 ±0,08 0.164 ±0.003 4,16 ±0,08 ALUMINUM BASEPLATE PINS: TIN/LEAD HOT SOLDER DIPPED 0.158 4,01 1 2 3 4 1.584* 40,23 1.900* 48.26 48,26 9 8 7 6 5 0.400* 10,16 0.43 10,9 0.700* 17,78 0.195 4,95 INBOARD SOLDER MOUNT 1.000* 25,40 1.400* 35,56 0.53 13,5 Unless otherwise specified, dimensions are in inches mm Decimals * DENOTES ±0.003 TOL = ±0,08 Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715 0.XX Tol. ±0.25 0.XXX Angles ±0.01 ±1° ±0.005 ±0.127 Page 7 of 8 The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com Vicor’s comprehensive line of power solutions includes modular, high density DC-DC converters and accessory components, configurable power supplies, and custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. 45 Component Solutions for Your Power System Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 978-470-2900 Fax: 978-475-6715 Email Vicor Express: [email protected] Technical Support: [email protected] P/N 22642 Rev 6 7/01/10M The latest data sheets for individual models are available on the Vicor website at www.vicorpower.com