DELTA V48SH05017NNFA

FEATURES
Š
Š
High efficiency: 91.5% @ 5V/17A
Size: 33.0x22.8x9.5mm
(1.30”x0.90”x0.37”)
Š
Industry standard footprint and pinout
Š
Fixed frequency operation
Š
SMD and through-hole versions
Š
Input UVLO
Š
OTP and output OCP, OVP
Š
Output voltage trim: -20%, +10%
Š
Monotonic startup into normal and
pre-biased loads
Š
1500V isolation and basic insulation
Š
No minimum load required
Š
No negative current during power or
enable on/off
Š
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS18001 certified manufacturing
facility
Š
UL/cUL 60950-1 (US & Canada) pending
Delphi Series V48SH, 1/16th Brick 100W
DC/DC Power Modules: 48V in, 5V, 17A out
th
The Delphi Series V48SH, 1/16 Brick, 48V input, single output, isolated
OPTIONS
DC/DC converter, is the latest offering from a world leader in power
Š
SMD pins
systems technology and manufacturing ― Delta Electronics, Inc. This
Š
Short pin lengths available
product family provides up to 100 watts of power or 40A of output current
Š
Positive remote On/Off
Š
Heat spreader
th
(1.8V and below) in an industry standard 1/16 brick form factor (1.30” x
0.90”). The 5V output offers one of the highest output currents available
and provides up to 91.5% efficiency at full load. With creative design
technology and optimization of component placement, these converters
possess outstanding electrical and thermal performance, as well as
extremely high reliability under highly stressful operating conditions. All
modules are protected from abnormal input/output voltage, current, and
temperature conditions. For lower power needs, but in a similar small
form factor, please check out Delta V36SE (50W), S48SP (36W or 10A)
APPLICATIONS
and S36SE (17W or 5A) series standard DC/DC modules.
Š
Optical Transport
Š
Data Networking
Š
Communications
Š
Servers
PRELIMINARY DATASHEET
DS_V48SH05017_07012009
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
V48SH05017 (Standard)
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms)
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Inrush Current (I2t)
Start up Current
Input Terminal Ripple Current
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output Over Current Protection
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Maximum Output Capacitance
EFFICIENCY
100% Load
60% Load
ISOLATION CHARACTERISTICS
Input to Output
Isolation Resistance
Isolation Capacitance
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
ON/OFF Current (for both remote on/off logic)
ON/OFF Current (for both remote on/off logic)
Leakage Current (for both remote on/off logic)
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
GENERAL SPECIFICATIONS
MTBF
Weight
Over-Temperature Shutdown
DS_V48SH05017_07012009
Max.
Units
80
100
121
125
1500
Vdc
Vdc
°C
°C
Vdc
75
Vdc
35.5
33.5
3
2.72
80
12
1
Vdc
Vdc
Vdc
A
mA
mA
A2s
3.23
0.1
8
45
4.85
0.15
15
A
A
mA
dB
5.0
5.075
Vdc
5.15
mV
mV
mV
V
110
35
160
50
17
150
mV
mV
A
%
100
100
100
160
160
200
mV
mV
us
12
12
28
28
ms
ms
Cap ESR>=8mohm;
Full load; 5% overshoot of Vout at startup;
0
7000
µF
Vin=48V
Vin=48V
90
90
100ms
Refer to figure 20 for measuring point
Typ.
-40
-55
36
32.5
30.5
1
34
32
2
100% Load, 36Vin
50
7
With 100uF external input capacitor
Peak, Vin=36V, 100% Load, With 10000uF Co
RMS, Vin=48V, With 100uF input cap.
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
Vin=48V, Io=Io.max, Tc=25°C
Io=Io, min to Io, max
Vin=36V to 75V
Tc=-40°C to125°C
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
Output Voltage 10% Low
4.925
±5
±5
±50
4.85
0
110
48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs
50% Io.max to 75% Io.max
75% Io.max to 50% Io.max
91.5
91.5
%
%
1500
1500
Vdc
MΩ
pF
300
kHz
10
Von/off
Von/off
-0.7
2
0.8
15
V
V
Von/off
Von/off
Ion/off at Von/off=0.0V
Ion/off at Von/off=2V
Logic High, Von/off=15V
Max rated current guaranteed at full trim range
Max rated current guaranteed at full remote
sense range
Over full temp range; % of nominal Vout
-0.7
2
0.8
15
0.3
50
10
V
V
mA
uA
uA
%
10
%
Per Telecordia SR-332, 100% load, 40°C, 48Vin,
400LFM
Per Telecordia SR-332, 50% load, 25°C, 48Vin,
400LFM
Open frame
Refer to figure 20 for measuring point
10
-20
130
%
1.4
M hours
6.6
M hours
14.2
128
grams
°C
2
ELECTRICAL CHARACTERISTICS CURVES
94
11.0
91
10.0
88
9.0
36Vin
8.0
85
48Vin
82
48Vin
36Vin
6.0
75Vin
79
75Vin
7.0
5.0
76
4.0
73
3.0
70
4
8
12
16
2.0
20
4
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C
8
12
16
20
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
3.5
INPUT CURRENT(A)
3
2.5
2
1.5
1
0.5
30
35
40
45
50
55
60
65
70
75
INPUTVOLTAGE(V)
Figure 3: Typical full load input characteristics at room
temperature
DS_V48SH05017_07012009
3
ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Start up
0
0
0
0
Figure 4: Turn-on transient at full rated load current
(10 ms/div). Vin=48V. Top Trace: Vout, 1.5V/div;
Bottom Trace: ON/OFF input, 5V/div
Figure 5: Turn-on transient at zero load current
(10 ms/div). Vin=48V. Top Trace: Vout: 1.5V/div,
Bottom Trace: ON/OFF input, 5V/div
For Input Voltage Start up
0
0
0
0
Figure 6: Turn-on transient at full rated load current
(10 ms/div). Vin=48V. Top Trace: Vout, 1.5V/div;
Bottom Trace: Vin , 20V/div
0
0
Figure 8: Output voltage response to step-change in
load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs).
Load cap: 10µF tantalum capacitor and 1µF ceramic
capacitor. Top Trace: Vout (100mV/div, 200us/div),
Bottom Trace: Iout (5A/div). Scope measurement should
be made using a BNC cable (length shorter than 20
inches). Position the load between 51 mm to 76 mm (2
inches to 3 inches) from the module
DS_V48SH05017_07012009
Figure 7: Turn-on transient at zero load current
(10 ms/div). Vin=48V. Top Trace: Vout, 1.5V/div;
Bottom Trace: Vin, 20V/div
0
0
Figure 9: Output voltage response to step-change in
load current (75%-50%-75% of Io, max; di/dt =
1.0A/µs). Load cap: 100µF tantalum capacitor and 1µF
ceramic capacitor. Top Trace: Vout (100mV/div,
200us/div), Bottom Trace: Iout (10A/div). Scope
measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from
the module
4
ELECTRICAL CHARACTERISTICS CURVES
is
ic
Vin+
+
+
0
Vin-
Cs: 220uF
100uF,
ESR=0.2 ohm @
25oC 100KHz
Figure 10: Test set-up diagram showing measurement points
for Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a
simulated source Inductance (LTEST) of 12 µH. Capacitor Cs
offset possible battery impedance. Measure current as shown
above
Figure 11: Input Terminal Ripple Current, ic, at full
rated output current and nominal input voltage with
12µH source impedance and 33µF electrolytic
capacitor (100 mA/div, 1us/div)
Copper Strip
Vo(+)
10u
0
1u
SCOPE
RESISTIVE
LOAD
Vo(-)
Figure 12: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load
current (20 mA/div, 1us/div)
Figure 13: Output voltage
measurement test setup
noise
and
ripple
0
Figure 14: Output voltage ripple at nominal input voltage
and rated load current (Io=40A)(50 mV/div, 1us/div)
Load capacitance: 1µF ceramic capacitor and 10µF
tantalum capacitor. Bandwidth: 20 MHz. Scope
measurements should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm
to 76 mm (2 inches to 3 inches) from the module.
DS_V48SH05017_07012009
5
DESIGN CONSIDERATIONS
Input Source Impedance
Š
The input source must be insulated from the ac
mains by reinforced or double insulation.
Š
The input terminals of the module are not operator
accessible.
Š
If the metal baseplate is grounded, one Vi pin and
one Vo pin shall also be grounded.
Layout and EMC Considerations
Š
Delta’s DC/DC power modules are designed to operate in
a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB layout
issues, please contact Delta’s technical support team. An
external input filter module is available for easier EMC
compliance design.
Application notes to assist
designers in addressing these issues are pending
release.
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few µH, we advise adding a 10 to 100 µF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the
input of the module to improve the stability.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and
IEC60950-1999, if the system in which the power module
is to be used must meet safety agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If the
input source is a hazardous voltage which is greater than
60 Vdc and less than or equal to 75 Vdc, for the module’s
output to meet SELV requirements, all of the following
must be met:
DS_V48SH05017_07012009
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
Fast-acting fuse with 30A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or drying is especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures,
please contact Delta’s technical support team.
6
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for an
unlimited duration during output overload. If the output
current exceeds the OCP set point, the modules will
automatically shut down, and enter hiccup mode or latch
mode, which is optional.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not used,
please short the on/off pin to Vi(-). For positive logic if the
remote on/off feature is not used, please leave the on/off
pin floating.
Vi(+)
For hiccup mode, the module will try to restart after
shutdown. If the over current condition still exists, the
module will shut down again. This restart trial will continue
until the over-current condition is corrected.
Sense(+)
ON/OFF
Sense(-)
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
set point, the module will shut down, and enter in hiccup
mode or latch mode, which is optional.
For hiccup mode, the module will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will continue
until the over-voltage condition is corrected.
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Vo(+)
Vi(-)
Vo(-)
Figure 15: Remote on/off implementation
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins and
the output terminals must not exceed the output voltage
sense range given here:
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout
This limit includes any increase in voltage due to remote
sense compensation and output voltage set point
adjustment (trim).
Over-Temperature Protection
The over-temperature protection consists of circuitry that
provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold the
module will shut down, and enter in auto-restart mode or
latch mode, which is optional.
For auto-restart mode, the module will monitor the module
temperature after shutdown. Once the temperature is
dropped and within the specification, the module will be
auto-restart.
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Vi(+) Vo(+)
Sense(+)
Sense(-)
Contact
Resistance
Vi(-)
Vo(-)
Contact and Distribution
Losses
Figure 16: Effective circuit configuration for remote sense
operation
Remote On/Off
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+) to
Vo(+) and SENSE(–) to Vo(–) at the module.
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the module
on during a logic low and off during a logic high. Positive
logic turns the modules on during a logic high and off
during a logic low.
The output voltage can be increased by both the remote
sense and the trim; however, the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
DS_V48SH05017_07012009
7
FEATURES DESCRIPTIONS (CON.)
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Max rated current is guaranteed at full output voltage
remote sense range.
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
connect an external resistor between the TRIM pin and
either the SENSE(+) or SENSE(-). The TRIM pin
should be left open if this feature is not used.
Figure 18: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and SENSE (+) the output voltage set point increases
(Fig. 19). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
Rtrim − up =
5 . 11 Vo (100 + ∆ ) 511
−
− 10 . 2 (K Ω )
1.225 ∆
∆
Ex. When Trim-up +10% (5V×1.1=5.5V)
5.11 × 5 × (100 + 10) 511
−
− 10.2 = 168.1(KΩ )
1.225 × 10
10
Figure 17: Circuit configuration for trim-down (decrease
output voltage)
Rtrim − up =
If the external resistor is connected between the TRIM
and SENSE (-) pins, the output voltage set point
decreases (Fig. 18). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
Trim resistor can also be connected to Vo+ or Vo- but it
would introduce a small error voltage than the desired
value.
 511

Rtrim − down = 
− 10 .2  (K Ω )
∆


Ex. When Trim-down -10% (5V×0.9=4.5V)
 511

Rtrim − down = 
− 10 .2  (K Ω ) = 40 . 9 (K Ω )
 10

The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Max rated current is guaranteed at full output voltage
trim range.
DS_V48SH05017_07012009
8
THERMAL CONSIDERATIONS
Thermal Derating
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Heat can be removed by increasing airflow over the module.
To enhance system reliability, the power module should
always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be affected.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
THERMAL CURVES
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Figure 20: Temperature measurement location
The allowed maximum hot spot temperature is defined at 121℃.
Output Current (A)
V48SH050(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation)
20
PWB
FACING PWB
MODULE
Natural
Convection
16
100LFM
200LFM
12
300LFM
400LFM
8
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
500LFM
4
600LFM
50.8 (2.0”)
AIR FLOW
0
25
12.7 (0.5”)
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 21: Output Current vs. Ambient Temperature and Air
Velocity @ Vin=48V (Either Orientation)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 19: Wind tunnel test setup
DS_V48SH05017_07012009
9
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT (SMD)
SURFACE-MOUNT TAPE & REEL
DS_V48SH05017_07012009
10
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE
Temperature (°C )
250
200
150
Ramp-up temp.
0.5~3.0°C /sec.
2nd Ramp-up temp. Peak temp.
1.0~3.0°C /sec. 210~230°C 5sec.
Pre-heat temp.
140~180°C 60~120 sec.
Cooling down rate <3°C /sec.
100
Over 200°C
40~50sec.
50
0
60
120
Time ( sec. )
180
240
300
Note: The temperature refers to the pin of V48SH, measured on the pin +Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE
Temp.
Peak Temp. 240 ~ 245 ℃
217℃
Ramp down
max. 4℃/sec.
200℃
Preheat time
100~140 sec.
150℃
Time Limited 90 sec.
above 217℃
Ramp up
max. 3℃/sec.
25℃
Time
Note: The temperature refers to the pin of V48SH, measured on the pin +Vout joint.
DS_V48SH05017_07012009
11
MECHANICAL DRAWING
Surface-mount module
Pin No.
1
2
3
4
5
6
7
8
Name
+Vin
ON/OFF
-Vin
-Vout
-SENSE
TRIM
+SENSE
+Vout
DS_V48SH05017_07012009
Through-hole module
Function
Positive input voltage
Remote ON/OFF
Negative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive remote sense
Positive output voltage
12
PART NUMBERING SYSTEM
V
48
Type of
Product
V - 1/16
Brick
S
H
1R8
40
N
R
Input Number of
Voltage Outputs
Product
Series
Output
Voltage
Output
Current
ON/OFF
Logic
Pin
Length/Type
4836V~75V
H - High
Power
1R8 - 1.8V
40 - 40A
N- Negative
P- Positive
R - 0.170”
N - 0.145”
S - Single
F
A
Option Code
F- RoHS 6/6 A - Standard Functions
(Lead Free) H - with Heatspreader
MODEL LIST
MODEL NAME
INPUT
OUTPUT
EFF @ 100% LOAD
V48SH1R840NNFA
36V~75V
3A
1.8V
40A
88.5%
V48SH05020NNFA
V48SH1R830NNFA
V48SH05017NNFA
36V~75V
36V~75V
36V~75V
4A
2.5A
4A
5.0V
1.8V
5.0V
20A
30A
17A
91.5%
89%
91.5%
Default remote on/off logic is negative and pin length is 0.170”
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office.
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
Ext 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications
at any time, without notice.
DS_V48SH05017_07012009