DELTA V48SR15004NRFA

FEATURES
High efficiency: 84.0% @ 1.2V/25A
Size: 33.0 x 22.9 x 9.5 mm
(1.30”x0.90”x0.37”)
Industry standard footprint and pinout
Fixed frequency operation
SMD and through-hole versions
Input UVLO and OVP
OTP and output OCP, OVP
Output voltage trim: -20%, +10%
Monotonic startup into normal and
pre-biased loads
2250V isolation and basic insulation
No minimum load required
No negative current during power or enable
on/off
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS18001 certified manufacturing
facility
UL/cUL 60950 (US & Canada), TUV
(EN60950) and CE mark pending
Delphi Series V48SR, 1/16th Brick 66W
DC/DC Power Modules: 48V in, 1.2V, 25A out
The Delphi Series V48SR, 1/16th Brick, 48V input, single output, isolated
DC/DC converter, is the latest offering from a world leader in power
systems technology and manufacturing ― Delta Electronics, Inc. This
product family provides up to 66 watts of power or 25A of output current
(1.8V and below) in an industry standard 1/16th brick form factor (1.30” x
0.90”). The 1.2V output offers one of the highest output currents available
and provides up to 84.0% efficiency at full load. With creative design
technology and optimization of component placement, these converters
possess outstanding electrical and thermal performance, as well as
extremely high reliability under highly stressful operating conditions. All
modules are protected from abnormal input/output voltage, current, and
temperature conditions. For lower power needs with the 1.2V output, but
in a similar small form factor, please check out Delta S48SP (36W or
1.2V/10A) and S48SE (17W or 1.2V/5A) series standard DC/DC
modules.
DATASHEET
DS_V48SR1R225_01312007
OPTIONS
SMD pins
Positive remote On/Off
OTP and output OVP, OCP mode
(auto-restart or latch)
APPLICATIONS
Optical Transport
Data Networking
Communications
Servers
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
V48SR1R225 (Standard)
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms)
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Inrush Current (I2t)
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output Over Current Protection
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Maximum Output Capacitance
EFFICIENCY
100% Load
60% Load
ISOLATION CHARACTERISTICS
Input to Output
Isolation Resistance
Isolation Capacitance
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
ON/OFF Current (for both remote on/off logic)
Leakage Current (for both remote on/off logic)
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
GENERAL SPECIFICATIONS
MTBF
Weight
Over-Temperature Shutdown
DS_V48SR1R225_01312007
100ms
Refer to figure 21 for measuring point
Typ.
-40
-55
36
33
31
1
34
32
2
100% Load, 36Vin
Max.
Units
80
100
127
125
2250
Vdc
Vdc
°C
°C
Vdc
75
Vdc
35
33
3
1.2
Vdc
Vdc
Vdc
A
mA
mA
A2s
mA
dB
50
10
1
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
Vin=48V, Io=Io.max, Tc=25°C
Io=Io, min to Io, max
Vin=36V to 75V
Tc=-40°C to125°C
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
Output Voltage 10% Low
20
60
1.188
1.200
1.212
Vdc
±10
±10
1.164
±3
±3
±12
1.20
1.236
mV
mV
mV
V
30
25
140
mV
mV
A
%
40
15
0
110
48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs
50% Io.max to 75% Io.max
75% Io.max to 50% Io.max
50
50
200
mV
mV
us
30
30
30000
Full load; 5% overshoot of Vout at startup
84.0
84.0
%
%
2250
1100
Vdc
MΩ
pF
420
kHz
10
Von/off
Von/off
Von/off
Von/off
Ion/off at Von/off=0.0V
Logic High, Von/off=15V
Pout ≦ max rated power
Pout ≦ max rated power
Over full temp range; % of nominal Vout
Io=80% of Io, max; Ta=25°C, airflow rate=300FLM
Refer to figure 21 for measuring point
2
2
-20
120
ms
ms
µF
130
2.22
16
130
0.7
18
V
V
0.7
18
1
50
10
10
160
V
V
mA
uA
%
%
%
M hours
grams
°C
2
ELECTRICAL CHARACTERISTICS CURVES
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 3: Typical full load input characteristics at room
temperature
DS_V48SR1R225_01312007
3
ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Logic
Figure 4: Turn-on transient at full rated load current (resistive
load) (5 ms/div). Vin=48V. Top Trace: Vout, 0.5V/div; Bottom
Trace: ON/OFF input, 5V/div
Figure 5: Turn-on transient at zero load current (5 ms/div).
Vin=48V. Top Trace: Vout: 0.5V/div, Bottom Trace: ON/OFF
input,5V/div
For Positive Remote On/Off Logic
Figure 6: Turn-on transient at full rated load current (resistive
load) (5 ms/div). Vin=48V. Top Trace: Vout, 0.5V/div; Bottom
Trace: ON/OFF input, 2V/div
DS_V48SR1R225_01312007
Figure 7: Turn-on transient at zero load current (5 ms/div).
Vin=48V. Top Trace: Vout, 0.5V/div; Bottom Trace: ON/OFF
input, 2V/div
4
ELECTRICAL CHARACTERISTICS CURVES
Figure 8: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:
10µF tantalum capacitor and 1µF ceramic capacitor. Top Trace:
Vout (50mV/div, 200us/div), Bottom Trace: Iout (10A/div).
Scope measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load between 51
mm to 76 mm (2 inches to 3 inches) from the module
Figure 9: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 1.0A/µs). Load cap:
100µF tantalum capacitor and 1µF ceramic capacitor. Top
Trace: Vout (50mV/div, 200us/div), Bottom Trace: Iout
(10A/div). Scope measurement should be made using a BNC
cable (length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from the
module
Figure 10: Test set-up diagram showing measurement points
for Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 µH. Capacitor Cs offset
possible battery impedance. Measure current as shown above
Figure 11: Input Terminal Ripple Current, ic, at full rated output
current and nominal input voltage with 12µH source impedance
and 33µF electrolytic capacitor (200 mA/div, 1us/div)
DS_V48SR1R225_01312007
5
ELECTRICAL CHARACTERISTICS CURVES
Copper Strip
Vo(+)
10u
1u
SCOPE
RESISTIV
LOAD
Vo(-)
Figure 12: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load current
(20 mA/div, 1us/div)
Figure 13: Output voltage noise and ripple measurement test
setup
Figure 14: Output voltage ripple at nominal input voltage and
rated load current (Io=25A)(50 mV/div, 1us/div)
Load capacitance: 1µF ceramic capacitor and 10µF tantalum
capacitor. Bandwidth: 20 MHz. Scope measurements should be
made using a BNC cable (length shorter than 20 inches).
Position the load between 51 mm to 76 mm (2 inches to 3
inches) from the module
Figure 15: Output voltage vs. load current showing typical
current limit curves and converter shutdown points
DS_V48SR1R225_01312007
6
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few µH, we advise adding a 10 to 100 µF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the
input of the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate in
a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB layout
issues, please contact Delta’s technical support team. An
external input filter module is available for easier EMC
compliance design.
Application notes to assist
designers in addressing these issues are pending
release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and
IEC60950-1999, if the system in which the power module
is to be used must meet safety agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If the
input source is a hazardous voltage which is greater than
60 Vdc and less than or equal to 75 Vdc, for the module’s
output to meet SELV requirements, all of the following
must be met:
DS_V48SR1R225_01312007
The input source must be insulated from the ac
mains by reinforced or double insulation.
The input terminals of the module are not operator
accessible.
If the metal baseplate is grounded, one Vi pin and
one Vo pin shall also be grounded.
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
normal-blow fuse with 5A maximum rating to be installed
in the ungrounded lead. A lower rated fuse can be used
based on the maximum inrush transient energy and
maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or drying is especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures,
please contact Delta’s technical support team.
7
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for an
unlimited duration during output overload. If the output
current exceeds the OCP set point, the modules will
automatically shut down, and enter hiccup mode or latch
mode, which is optional.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not used,
please short the on/off pin to Vi(-). For positive logic if the
remote on/off feature is not used, please leave the on/off
pin floating.
For hiccup mode, the module will try to restart after
shutdown. If the over current condition still exists, the
module will shut down again. This restart trial will continue
until the over current condition is corrected.
Vi(+)
Vo(+)
Sense(+)
ON/OFF
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Sense(-)
Vi(-)
Vo(-)
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
threshold, the module will shut down, and enter in hiccup
mode or latch mode, which is optional.
For hiccup mode, the module will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will continue
until the over voltage condition is corrected.
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Figure 16: Remote on/off implementation
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins and
the output terminals must not exceed the output voltage
sense range given here:
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout
This limit includes any increase in voltage due to remote
sense compensation and output voltage set point
adjustment (trim).
Over-Temperature Protection
The over-temperature protection consists of circuitry that
provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold the
module will shut down, and enter in hiccup mode or latch
mode, which is optional.
Vi(+) Vo(+)
Sense(+)
Sense(-)
For hiccup mode, the module will try to restart after
shutdown. If the over temperature condition still exists,
the module will shut down again. This restart trial will
continue until the over temperature condition is corrected.
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Contact
Resistance
Vi(-)
Vo(-)
Contact and Distributio
Losses
Figure 17: Effective circuit configuration for remote sense
operation
Remote On/Off
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+) to
Vo(+) and SENSE(–) to Vo(–) at the module.
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the module
on during a logic low and off during a logic high. Positive
logic turns the modules on during a logic high and off
during a logic low.
The output voltage can be increased by both the remote
sense and the trim; however, the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
DS_V48SR1R225_01312007
8
FEATURES DESCRIPTIONS (CON.)
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum output
power does not exceed the maximum rated power.
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
connect an external resistor between the TRIM pin and
either the SENSE(+) or SENSE(-). The TRIM pin
should be left open if this feature is not used.
Figure 19: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and SENSE (+) the output voltage set point increases
(Fig. 19). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
Rtrim − up =
5 .11Vo (100 + ∆ ) 511
−
− 10 .2 (K Ω )
∆
0.6 ∆
Ex. When Trim-up +10% (1.2V×1.1=1.32V)
5.11× 1.2 × (100 + 10) 511
−
− 10.2 = 51.1(KΩ )
0.6 × 10
10
Figure 18: Circuit configuration for trim-down (decrease
output voltage)
Rtrim − up =
If the external resistor is connected between the TRIM
and SENSE (-) pins, the output voltage set point
decreases (Fig. 18). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
Trim resistors can also be connected to Vo+ or Vobut connecting this way would introduce a small error
voltage than the desired value.
⎡ 511
⎤
Rtrim − down = ⎢
− 10 .2 ⎥ (K Ω )
⎣ ∆
⎦
The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
Ex. When Trim-down -10% (1.2V×0.9=1.08V)
⎡ 511
⎤
Rtrim − down = ⎢
− 10 .2 ⎥ (K Ω ) = 40 .9 (K Ω )
⎣ 10
⎦
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power of the module remains at or below the
maximum rated power.
DS_V48SR1R225_01312007
9
THERMAL CONSIDERATIONS
Thermal Derating
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Heat can be removed by increasing airflow over the module.
To enhance system reliability, the power module should
always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be affected.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
THERMAL CURVES
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Figure 21: Temperature measurement location
The allowed maximum hot spot temperature is defined at 127℃.
V48SR1R225(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation)
Output Current (A)
PWB
FACING PWB
25
MODULE
Natural
Convection
20
100LFM
200LFM
15
300LFM
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
10
50.8 (2.0”)
5
AIR FLOW
0
65
12.7 (0.5”)
70
75
80
85
Ambient Temperature (℃)
Figure 22: Output Current vs. Ambient Temperature and Air
Velocity @ Vin=48V (Either Orientation)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 20: Wind tunnel test setup
DS_V48SR1R225_01312007
10
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT (SMD)
SURFACE-MOUNT TAPE & REEL
DS_V48SR1R225_01312007
11
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE
Temperature (°C )
250
200
150
Ramp-up temp.
0.5~3.0°C /sec.
2nd Ramp-up temp. Peak temp.
1.0~3.0°C /sec. 210~230°C 5sec.
Pre-heat temp.
140~180°C 60~120 sec.
Cooling down rate <3°C /sec.
100
Over 200°C
40~50sec.
50
0
60
120
Time ( sec. )
180
240
300
Note: The temperature refers to the pin of V48SR, measured on the pin +Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE
Temp.
Peak Temp. 240 ~ 245 ℃
217℃
Ramp down
max. 4℃/sec.
200℃
150℃
Preheat time
100~140 sec.
Time Limited 90 sec.
above 217℃
Ramp up
max. 3℃/sec.
25℃
Time
Note: The temperature refers to the pin of V48SR, measured on the pin +Vout joint.
DS_V48SR1R225_01312007
12
MECHANICAL DRAWING
Surface-mount module
Pin No.
1
2
3
4
5
6
7
8
Name
+Vin
ON/OFF
-Vin
-Vout
-SENSE
TRIM
+SENSE
+Vout
DS_V48SR1R225_01312007
Through-hole module
Function
Positive input voltage
Remote ON/OFF
Negative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive remote sense
Positive output voltage
13
PART NUMBERING SYSTEM
V
48
Type of
Product
S
Input Number of
Voltage Outputs
V –1/16
brick
48V
S - Single
R
1R2
25
N
R
F
Product
Series
Output
Voltage
Output
Current
ON/OFF
Logic
Pin
Length/Type
Regular
1R2 – 1.2V
25 - 25A
N- Negative
P- Positive
R - 0.170”
N - 0.145”
K - 0.110”
M - SMD
A
Option Code
F- RoHS 6/6
(Lead Free)
A - Standard Functions
MODEL LIST
MODEL NAME
V48SR1R225NRFA
V48SR1R525NRFA
V48SR1R825NRFA
V48SR2R520NRFA
V48SR3R320NRFA
V48SR05013NRFA
V48SR12005NRFA
V48SR15004NRFA
INPUT
36V~75V
36V~75V
36V~75V
36V~75V
36V~75V
36V~75V
36V~75V
36V~75V
OUTPUT
1.2A
1.4A
1.6A
1.8A
2.4A
2.3A
2.3A
2.3A
1.2V
1.5V
1.8V
2.5V
3.3V
5.0V
12V
15V
EFF @ 100% LOAD
25A
25A
25A
20A
20A
13A
5.5A
4.4A
84.0%
85.0%
87.0%
89.0%
90.5%
91.0%
91.0%
91.0%
Default remote on/off logic is negative and pin length is 0.170”
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office.
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107 ext 6220
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications
at any time, without notice.
DS_V48SR1R225_01312007
14