CUI VAD10-D48-D15

rev.
page
1 of 3
date
08/2007
DESCRIPTION: DC/DC converter
PART NUMBER: VAD10 series
features
·7.5-10 W isolated output
·24-pin DIP shielded metal case
·efficiency to 89%
·wide 2:1 input range
·regulated outputs
·Pi input filter
·continuous short circuit protection
·no tantalum capacitor inside
model
number
VAD10-D12-S2R5
VAD10-D12-S3R3
VAD10-D12-S5
VAD10-D12-S12
VAD10-D12-S15
VAD10-D12-D12
VAD10-D12-D15
VAD10-D24-S2R5
VAD10-D24-S3R3
VAD10-D24-S5
VAD10-D24-S12
VAD10-D24-S15
VAD10-D24-D12
VAD10-D24-D15
VAD10-D48-S2R5
VAD10-D48-S3R3
VAD10-D48-S5
VAD10-D48-S12
VAD10-D48-S15
VAD10-D48-D12
VAD10-D48-D15
input
voltage
9-18 VDC
9-18 VDC
9-18 VDC
9-18 VDC
9-18 VDC
9-18 VDC
9-18 VDC
18-36 VDC
18-36 VDC
18-36 VDC
18-36 VDC
18-36 VDC
18-36 VDC
18-36 VDC
36-75 VDC
36-75 VDC
36-75 VDC
36-75 VDC
36-75 VDC
36-75 VDC
36-75 VDC
output
voltage
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
output
current
3000 mA
3000 mA
2000 mA
835 mA
666 mA
416 mA
333 mA
3000 mA
3000 mA
2000 mA
835 mA
666 mA
416 mA
333 mA
3000 mA
3000 mA
2000 mA
835 mA
666 mA
416 mA
333 mA
input current
no load
full load
40 mA
753 mA
40 mA
971 mA
40 mA
958 mA
40 mA
949 mA
40 mA
946 mA
20 mA
956 mA
20 mA
968 mA
30 mA
375 mA
30 mA
480 mA
30 mA
475 mA
30 mA
470 mA
30 mA
468 mA
20 mA
473 mA
20 mA
478 mA
15 mA
185 mA
15 mA
240 mA
15 mA
240 mA
15 mA
235 mA
15 mA
234 mA
10 mA
236 mA
10 mA
239 mA
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
efficiency
83%
85%
87%
88%
88%
87%
86%
83%
85%
88%
89%
89%
88%
87%
83%
85%
87%
89%
89%
88%
87%
rev.
page
2 of 3
date
08/2007
DESCRIPTION: DC/DC converter
PART NUMBER: VAD10 series
INPUT
input voltage range
under voltage lockout
12
24
48
12
12
24
24
48
48
V
V
V
Vin
Vin
Vin
Vin
Vin
Vin
power
power
power
power
power
power
up
down
up
down
up
down
input filter
9-18 V
18-36 V
36-75 V
8.8 V
8 V
17 V
16 V
34 V
32 V
Pi type
OUTPUT
voltage accuracy
temperature coefficient
ripple and noise
short circuit protection
line regulation 1
load regulation 2
over voltage protection
20MHz BW
single
dual
single - DIP / SMD
dual
2.5 V
3.3 V
5 V
12 V
±1.0% max.
±0.05% / °C max.
75mV p-p max.
continuous
±0.2% max
±0.5% max
±0.5% / ±1.0% max
±1.0% max
3.6 V
3.9 V
6.2 V
15 V
GENERAL SPECIFICATIONS
efficiency
isolation resistance
switching frequency
operating temperature range
storage temperature
case temp.
cooling
dimensions
case material
weight
see table
10 9 Ohms
380KHz typ.
-40°C to +85°C
-40°C to +125°C
100°C max.
free air convection
1.25x0.8x0.4 inches
(31.8x20.3x10.2mm)
black-coated copper with non-conductive base
18.4 g
NOTES:
1. Measured from high line to low line
2. Measured from full load to 10% load
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
3 of 3
date
08/2007
DESCRIPTION: DC/DC converter
PART NUMBER: VAD10 series
DIMENSIONS (mm)
NOTE: Pin Size is 0.020" Inch (0.5mm) DIA
All Dimensions In Inches(mm)
Tolerance .xx= ±.02, .xxx= ±.010
Derating Curve:
Loed (%)
100
22
3
BOTTOM
VIEW
16
50
-40
71
100
9
Pin
Single
Output
2
-V Input
3
14
11
0.6 (15.24)
0.15 (3.8)
0.8 (20.3)
0.40 (10.2)
-V Input
NP
Common
11
NC
-V Input
14
+V Output
+V Output
16
-V Output
Common
22
+V Input
+V Input
23
+V Input
+V Input
DERATING CURVE
120%
Output Load(%)
71
-40
80%
60%
Vo=3.3V
Others
40%
20%
100
0%
-40
-20
0
20
40
60
80
Dual
Output
9
A ll Speci fication s Typical A t N ominal Line , Full Load and 25 °C U nle ss O the rwi se N oted .
100%
(Deg.C
PIN CONN ECTION
0.60 (15.24)
2
1.25 (31.8)
23
0.20 (5.08)
0.10 (2.54)
0.18 (4.5)
-3.45% / C
100
Ambient Temperature( ˚C)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382