CUI VOF-15-5

date 03/2010
page 1 of 4
a division of CUI INC
SERIES:
SWITCHING POWER SUPPLY
DESCRIPTION:
VOF-15
FEATURES
•RoHS compliant
•universal input 85~264 V ac
•over-voltage protection
•over-current protection
•no minimum load required
•UL/cUL, TUV, CE safety approvals
•conducted EMI meets EN55022 class B, FCC class B
•efficiency up to 83%
RoHS
MODEL
output voltage
VOF-15-3.3
output current
output wattage
ripple3
efficiency
nominal
(V dc)
min
(A)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
3.3
0
3.0
9.9
100
70
5
0
3.0
15
100
75
VOF-15-5
VOF-15-9
9
0
1.67
15
120
78
VOF-15-12
12
0
1.25
15
120
80
VOF-15-15
15
0
1.0
15
150
80
VOF-15-24
24
0
0.63
15
240
82
48
0
0.31
15
480
83
VOF-15-48
notes:
1. Measured from high line to low line at full load
2. Measured from full load to 10% load at 110 V ac
3. Ripple & noise are measured at 20 MHz BW with 0.1 μF ceramic and 10 μF electrolytic capacitors on the output
DE-RATING CURVE
1. Input volgate vs. load factor
b. all other models
Load factor (%)
Load factor (%)
a. 3.3 V and 5 V models
100
80
60
40
20
100
80
60
40
20
0
0
0
85
110 120
220
264
0
85
90
220
264
Input Voltage AC(V)
Input Voltage AC(V)
2. Thermal derating, ambient temp. vs. load factor
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
date 03/2010
page 2 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
VOF-15
SWITCHING POWER SUPPLY
INPUT
parameter
conditions/description
min
frequency
voltage
inrush current
max
units
47
nom
63
Hz
85
120
264
375
V ac
V dc
20
40
A
A
max
units
115 V ac, cold start
230 V ac, cold start
OUTPUT
parameter
conditions/description
min
nom
line regulation
low line to high line
±0.5
%
load regulation
full load to min load
±1
%
over voltage protection
output shut down, power reset required
over current protection
TVS
105
temperature coefficient
0 ~ 40°C, full load, after 1 hour warm-up
hold-up time
110 V ac at full load
%
±0.05
%/°C
16
ms
SAFETY & EMI
parameter
conditions/description
min
isolation voltage
at 10 mA for 1 minute, 20 mA max.
isolation resistance
input to output at 500 V dc
safety approvals
UL/cUL 60950, TUV EN60950
EMI/EMC
FCC class B, EN55022 class B, CE
nom
3,000
units
V ac
50
M
leakage current
RoHS compliant
max
0.25
mA
yes
ENVIRONMENTAL
parameter
conditions/description
max
units
operating temperature
see de-rating curve
min
0
nom
45
°C
storage temperature
see de-rating curve
-25
75
°C
relative humidity
non-condensing
20
90
%
parameter
conditions/description
min
max
units
dimensions
2.75 x 1.89 x 0.91 (L x W x H)
input/output connectors
industrial pins for PCB mounting
GENERAL
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
nom
fax 503.612.2382 www.v-infinity.com
REV.
A
DESCRIPTION
NEW DRAWING
DATE
1/11/2010
70.0 2.756
0.5
62.0 2.441
(2 PLCS) 0.1
L
+Vo
8.5 0.335
0.1
11.5 0.453
0.1
48.6 1.913
0.5
N
11.5 0.453
0.1
GND
13.1 0.516
0.1
1.1 0.043
(4 PLCS) 0.1
18.0 0.709
0.5
RoHS
TOLERANCE:
±0.3mm UNLESS OTHERWISE
SPECIFIED
8.0 0.315
(4 PLCS)
1.0 0.039
(4 PLCS)
20050 SW 112th Ave.
Tualatin, OR 97062
Phone: 503-612-2300
800-275-4899
Fax: 503-612-2383
Website: www.cui.com
TITLE:
SWITCHING POWER SUPPLY
PART NO.
PC FILE NAME:
VOF-15
COPYRIGHT 2010 BY CUI INC.
ZRJ
A
UNITS:
VOF-15
DRAWN BY:
REV:
MM [INCHES]
APPROVED BY:
SCALE:
1:1
REV.
A
DESCRIPTION
NEW DRAWING
DATE
1/11/2010
B. Horizontal
RoHS
TOLERANCE:
±0.3mm UNLESS OTHERWISE
SPECIFIED
A. Vertical
20050 SW 112th Ave.
Tualatin, OR 97062
Phone: 503-612-2300
800-275-4899
Fax: 503-612-2383
Website: www.cui.com
TITLE:
SWITCHING POWER SUPPLY
PART NO.
PC FILE NAME:
VOF-15
COPYRIGHT 2010 BY CUI INC.
ZRJ
A
UNITS:
VOF-15
DRAWN BY:
REV:
MM [INCHES]
APPROVED BY:
SCALE: