Model WS10 with analog or SSI output Compact sensor for industrial applications · Protection class IP65 · Measurement ranges: 0 ... 100 mm to 0 ... 1250 mm · Analog output 0 … 10 V, 4 … 20 mA, potentiometer or A/D converted synchronous serial output (SSI) Outputs Potentiometer: 1 kW Voltage: 0...10 V Current: 4...20 mA, 2 or 3 wire Voltage and current output, adjustable A/D converted synchronous serial 16 bit max. (SSI) Essentially infinite / ADSI16: max. 16 bit full scale Aluminium and stainless steel. Cable: stainless steel Precision potentiometer Male socket 8 pin (M12 or DIN 45326) Up to ±0.05 % full scale IP65 (only when the electrical plug is correctly assembled and connected) 800 g approx. Specifications Resolution Material Sensing Device Connector Linearity Protection Class Weight Environmental EMC Temperature Order Code WS10 Analog or SSI Refer to output specification Refer to output specification WS10 Model Name Measurement Range (in mm) 100 / 125 / 375 / 500 / 750 / 1000 / 1250 Outputs (see pages 57 ff.) R1K = Potentiometer 1 kW (other values on request) 10V = With 0 ... 10 V signal conditioner 420A = With 4 ... 20 mA signal conditioner (2 wire) 420T = With 4 ... 20 mA signal conditioner (3 wire) PMU = With 0...10 V/4...20 mA signal conditioner, adjustable ADSI16 = With A/D converted synchronous serial output 16 bit (option: 12, 14 bit) Linearity L10 = ±0.10 % option: L05 = ±0,05 % L25 = ±0.25 % Cable fixing M4 = M4 cable fixing SB0 = Cable clip Connection M12 = 8 pin socket M12 D8 = 8 pin socket DIN 45326 Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G Order Example: WS10 - 1250 - 10V - L10 - M4 - M12 8 CAT-WS-E-05 www.asm-sensor.com ASM Model WS10 with analog or SSI output Cable Forces typical at 20 °C Range mm 100 125 375 500 750 1000 1250 Maximum pull-out force [N] 4.7 4.6 7.4 5.5 7.6 5.3 4.6 Minimum pull-in force [N] 3.0 2.4 3.9 2.8 3.8 2.9 2.4 Outline drawing Option SB0 Dimensions informative only. For guaranteed dimensions consult factory Dimensions (mm) ASM Range A B, C D (ADSI16) 375; 750 100; 125; 500 1000; 1250 12.5 8.0 8.0 B=31, C=38.5 93.5 (120.5) www.asm-sensor.com CAT-WS-E-05 9 Model WS10 with incremental encoder output Compact sensor for industrial applications · Protection class IP65 · Measurement range: 0 ... 1250 mm · With incremental encoder output Outputs Incremental encoder output with differential push-pull circuit for reliable data transmission. The output is compatible with TTL or HTL. 10 pulses per mm (1/40 mm with external edge counting mode) Aluminium and stainless steel. Cable: stainless steel Incremental encoder Male socket 8 pin (M12 or DIN 45326) ±0.05 % full scale IP65 (only when the electrical plug is correctly assembled and connected) 800 g approx. Specifications Resolution Material Sensing Device Connector Linearity Protection Class Weight Environmental EMC Temperature Order Code WS10 Incremental Refer to output specification Refer to output specification WS10 Model Name Measurement Range (in mm) 1250 (all smaller measurement ranges included) Pulses per mm 10 = 10 pulses per mm 25 = 25 pulses per mm (output PP530 only) Other numbers of pulses on request Output (see page 60) IE24LI = Incremental output TTL compatible inverted IE24HI = Incremental output HTL compatible inverted PP530 = Incremental output TTL and HTL compatible Cable fixing M4 = M4 cable fixing SB0 = Cable clip Connection M12 = 8 pin socket M12 D8 = 8 pin socket DIN 45326 Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G Order Example: WS10 - 1250 - 10 - IE24HI - M4 - M12 10 CAT-WS-E-05 www.asm-sensor.com ASM Model WS10 with incremental encoder output Cable Forces typical at 20 °C Resolution Pulses per mm Maximum Pull-out Force [N] Minimum Pull-in Force [N] 10 5.8 3.0 Outline drawing Option SB0 Dimensions informative only. For guaranteed dimensions consult factory ASM www.asm-sensor.com CAT-WS-E-05 11 Output Specifications R1K and 10V for WS position sensors Voltage divider R1K Potentiometer Excitation Voltage 32 VDC max. at 1 kW (input power 1 W max.) Potentiometer Impedance 1 kW ±10% ±25 x 10-6/ °C full scale Depends on measurement range, individual sensitivity of sensor specified on label Approx. 3% ... 97% of full range -20 ... +85 °C Thermal coefficient Sensitivity Voltage Divider Utilization Range Operating Temperature Signal diagram + Vin Note: The potentiometer must be connected as a voltage divider. The input impedance of the following processing circuit should be 10 MW min. + Vout GND Signal conditioner 10V Voltage output Excitation Voltage Excitation Current Output Voltage Output Current Output Load +18 ... +27 V DC non stabilized 20 mA max. 0 ... +10 V DC 2 mA max. > 5 kW ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0,5 mVRMS -20 ... +85 °C According to EN 61326:2004 Stability (Temperature) Protection Output Noise Operating Temperature EMC Excitation + Signal diagram 10V Excitation GND Signal + 0...10 V Signal GND Signal Wiring Output signals R1K + Vin GND + Vout Connection Mating Connector 10V Excitation + Excitation GND Signal + Signal GND Connector pin no. White Brown Green Yellow 1 2 3 4 View to solder terminals CONN-DIN-8F-W ASM Cable color www.asm-sensor.com CONN-M12-8F-G CAT-WS-E-05 57 Output Specifications 420A and 420T for WS position sensors Excitation Voltage Signal conditioner 420A Current output (2 wire) +12 ... 27 VDC non stabilized, measured at the sensor terminals 35 mA max. 4 ... 20 mA equivalent to 0 ... 100% range ±100 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Excitation Current Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC Signal + Signal Diagram 420A 4...20 mA Signal Conditioner 420T Current output (3 wire) Signal – Excitation Voltage Excitation Current Load Resistor +18...+27 V DC non stabilized 40 mA max. 350 W max. 4 ... 20 mA equivalent to 0 ... 100% range ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC Signal diagram Excitation + 420T Signal + 4...20 mA Signal Wiring Output signals 420A Signal + Signal – Connection Mating Connector Excitation GND 420T Excitation + Excitation GND Signal + CAT-WS-E-05 Connector pin no. White Brown Green 1 2 3 View to solder terminals CONN-DIN-8F-W 58 Cable color www.asm-sensor.com CONN-M12-8F-G ASM Output Specification PMU for WS position sensors Signal Conditioner PMU, adjustable Voltage output and current output (3 wire) Excitation voltage Excitation current Voltage output Output current Output load Current output Load resistor +18 ... 27 V DC 50 mA max. 0 ... 10 V 10 mA max. 1 kW min. 4 ... 20 mA (3 wire) 500 W max. Adjustment Activation of offset and gain adjust Scalable range Stability (Temperature) Protection Output noise Operating temperature EMC Connect with excitation GND (0 V) 90 % max. full scale ±50 x 10-6 / °C full scale Reverse polarity, short circuit 1 mVeff -20 ... +85 °C According to EN 61326:2004 Signal diagram Excitation + Excitation GND Signal 0...10 V + PMU Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Output signals Signal wiring Connector pin no. Excitation + Excitation GND Signal 0...10 V + Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Offset Gain 1 2 3 4 5 6 7 8 Connection Mating Connector View to solder terminals CONN-DIN-8F-W ASM www.asm-sensor.com CONN-M12-8F-G CAT-WS-E-05 59 Output Specification ADSI16 for WS position sensors · · · · Description Resolution 16 bit, data transmission synchronous serial/SSI Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution No loss of data at power-down Easy to connect to PLC’s with SSI input circuit The sensing device of the ADSI is a precision potentiometer. The position information is given by an analog/digital converter output serialized as a data word. Data transmission takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Microcomputer) sends pulse sequences which clock the data transmission with the required transfer rate. With the first falling edge of a pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit A/D conversion, encoding and output of the data word. After a delay time the next new position information will be transmitted. Data Format (Train of 26 Pulses) Signal Conditioner ADSI A/D converted synchronous serial Output Excitation voltage Excitation current Clock frequency Code Delay between pulse trains Resolution EIA RS-422, RS-485, short-circuit proof 11 ... 27 VDC 200 mA max. 70 ... 500 kHz Gray code, continuous progression T=30 µs min. 16 bit (65536 counts) full scale; optional 12 bit or 14 bit ±50 x 10-6 / °C full scale -20 ... +85 °C According to EN 61326:2004 Stability (temperature) Operation temperature EMC Recommended Processing Input Circuit Sensor circuit Cable Subsequent circuit GND (0V) Transmission rate Cable length Baud rate < 50 m < 100 m < 300 kHz < 100 kHz Signal names Signal Wiring 64 CAT-WS-E-05 Connector pin no. Excitation + Excitation GND (0V) CLOCK CLOCK DATA DATA Screen 1 2 3 4 5 6 not connected www.asm-sensor.com Note: Extension of the cable length will reduce the maximum transmission rate. The signals CLOCK/CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded per pair and common. Mating connector: view to solder terminals CONN-DIN-8F-W CONN-M12-8F-G ASM Output Specifications IE24LI and IE24HI for WS position sensors IE24LI and IE24HI incremental IE24LI IE24HI 5 V DC ±10 % 10 … 30 V DC 100 mA max. 200 kHz Push-pull and inverted signals 10 mA max. Depending on the excitation voltage ±20 x 10-6 / °C f.s. (sensor mechanism) -20 … +85 °C Short circuit According to EN 61326:2004 Excitation voltage Excitation current Output frequency Output Output current Output voltage Stability (temperature) Operation temperature Protection EMC Output signals Excitation + Excitation GND Signal A Encoder Signal A IE24LI IE24HI Signal B Signal B Signal Z (reference pulse) Signal Z Output circuit and recommended processing input circuit Output signals Signal wiring Connection Mating connector 60 CAT-WS-E-05 Cable color Connector pin no. Brown White Grey Green Pink Yellow Blue Red 1 2 3 4 5 6 7 8 CONN-DIN-8F-W CONN-M12-8F-G Excitation + Excitation GND Signal B (A + 90°) Signal A Signal B Signal A Signal Z (reference pulse) Signal Z View to solder terminals www.asm-sensor.com ASM Output Specification PP530 for WS position sensors Signal Conditioner PP530 Incremental Excitation Voltage Excitation Current Output Frequency Output +5 ... +30 VDC 200 mA max. 200 kHz max. Linedriver, Push-Pull, CMOS, TTL and HTL compatible 30 mA max., short circuit protection Depends on the excitation voltage (e.g. to obtain TTL-signals the excitation must be 5 V.) Compatible to EIA RS-422/RS-485 ±20 x 10-6 / K full scale (sensor mechanism) -10 ... +70 °C -30 ... +80 °C 250 ns 250 ns Reverse polarity, short circuit According to EN61326:2004 Output Current Output Voltage Stability (Temperature) Operation Temperature Storage Temperature Transition Time Positive Edge Transition Time Negative Edge Protection EMC Signal Diagram Excitation + Excitation GND Signal A Encoder Signal A PP530 Signal B Signal B Signal Z (Reference pulse) Signal Z Recommended Processing Circuit Signal Levels Excitation Level Ia £ 5 mA Ia £ 25 mA 5V 5V 24 V 24 V UaHigh UaLow UaHigh UaLow >4.2 V <0.5 V >23.5 V <0.5 V >4.2 V <1.2 V >23.5 V <1.2 V Output signals Signal Wiring / Connection Connector CONN-DIN-8F Excitation + Excitation GND (0V) Signal B (A + 90°) Signal A Signal B Signal A Signal Z (reference pulse) Signal Z 1 2 3 4 5 6 7 8 -Ia £ 5 mA >4.1 V <0.4 V >23.5 V <0.4 V -Ia £ 25 mA >3.8 V <0.4 V >22.5 V <0.4 V Mating connector View to solder terminals CONN-DIN-8F-W ASM www.asm-sensor.com CAT-WS-E-05 63