ETC 42A005G

Models 42, 43 Medium Pressure
PC Board Mountable Pressure Sensor
0-100 mV Output
Gage and Absolute Pressure
Temperature Compensated
þ
Medical Instrumentation
þ
HVAC
þ
Process Control
þ
Vacuum Measurement
þ
Air Flow Management
DESCRIPTION
The Models 42 and 43 are temperature compensated,
piezoresistive silicon pressure sensors packaged in TO-8
configurations. They provide excellent performance and longterm stability.
Gage and absolute pressure ranges from 0-2 PSI to 0-250
PSI are available. Integral temperature compensation is
provided over a range of 0-50°C using laser-trimmed resistors.
An additional laser-trimmed resistor is included in the Model 43
to normalize pressure sensitivity variations by programming the
gain of an external differential amplifier. This provides
sensitivity interchangeability of ±1%.
Please refer to the low pressure section for information on
products with operating pressures less than 0-2 PSI. An
uncompensated sensor (Model 40) is also available. For sensors
FEATURES
in a dual-in-line package please refer to the Models 1210 and
1220. Please contact the factory for additional information.
þ
TO-8 Package
þ
±0.1% Non-linearity
þ
±0.5% Temperature Performance
þ
Solid State Reliability
þ
Low Power
DIMENSIONS
STANDARD RANGES
1-36
Range
psig
psia
0 to 2
●
0 to 5
●
0 to 10
●
●
0 to 15
●
●
0 to 30
●
●
0 to 50
●
0 to 100
●
0 to 250
●
TO-8 – Standard
Models 42, 43 Medium Pressure
PC Board Mountable Pressure Sensor
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25°C (Unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
UNITS
Full Scale Output Span
75
100
150
mV
Full Scale Output Span (2 psi version)
30
Zero Pressure Output
60
mV
2
±mV
Pressure Non-linearity
0.05
0.10
±% Span
Pressure Hysteresis
0.01
0.05
±% Span
NOTES
1
4400
6000
Ω
Temperature Error – Span
0.3
0.5
±% Span
Temperature Error – Zero
0.1
0.5
±% Span
2
Thermal Hysteresis – Span
0.1
±% Span
2
Thermal Hysteresis – Zero
0.1
±% Span
2
Supply Current
1.5
mA
3
Response Time
1.0
msec
4
Output Noise
1.0
µV p-p
5
Input & Output Resistance
2500
Output Load Resistance
Insulation Resistance (50 VDC)
2.0
2
MΩ
50
MΩ
6
Rated
7
Pressure Overload
3X
Operating Temperature
–40°C to +125°C
Storage Temperature
–50°C to +150°C
Acceleration
50g Max
Shock
1000g Peak for 0.5 mS
Vibration
20g Peak at 10 to 2000 Hz
Media
Non-Corrosive Gases
Weight
3 Grams
Notes
1. Best Fit Straight Line.
2. Temperature range 0-50°C in reference to 25°C.
3. Guarantees input/output ratiometricity.
4. For a zero-to-full scale pressure step change.
5. 10 Hz to 1 kHz.
CONNECTIONS
M o de l 4 2
2
8
6.
7.
8.
Between case and sensing element.
3X not to exceed 500 psi on ranges: 0-10 psi to 0-250 psi; 20 psi for 2
psi and 5 psi versions.
For Top Entry versions, wetted materials are silicon, aluminum, gold,
RTV, glass, and nickel. For Bottom Entry versions, wetted materials are
silicon, RTV, gold, and glass.
ORDERING INFORMATION
43A - 015 G
Type (G = Gage, A = Absolute)
Pressure Range
Model (43 or 42) (with or without gain set)
Mo d el 4 3
APPLICATION SCHEMATIC
April 2000
TO-8 – Standard
1-37