Preliminary Information X1240 16K 2-Wire RTC Real Time Clock/Calendar with EEPROM FEATURES DESCRIPTION • 2-Wire Interface interoperable with I2C. —400kHz data transfer rate • Secondary Power Supply Input with internal switch-over circuitry. • Year 2000 Compliant • 2K bytes of EEPROM —64 Byte Page Write Mode —3 bit Block Lock • Low Power CMOS —<1µA Operating Current —<3mA Active Current during Program —<400µA Active Current during Data Read • Single Byte Write Capability • Typical Nonvolatile Write Cycle Time: 5ms • High Reliability —1,000,000 Endurance Cycles —Guaranteed Data Retention: 100 Years • Small Package Options —8-Lead SOIC Package, 8L TSSOP Package The X1240 is a Real Time Clock with clock/calendar circuits. The dual port clock register allows the clock to operate, without loss of accuracy, even during read and write operations. The clock/calendar provides functionality that is controllable and readable through a set of registers. The clock, using a low cost 32.768kHz crystal input, accurately tracks the time in seconds, minutes, hours, date, day, month and years. It has leap year correction, automatic adjustment for the year 2000 and months with less than 31 days. The device offers a backup power input pin. This Vback pin allows the device to be backed up by a nonrechargeable battery. The RTC is fully operational from 1.8 to 5.5 volts. The X1240 provides a 2K byte EEPROM array, giving a safe, secure memory for critical user and configuration data. This memory is unaffected by complete failure of the main and backup supplies. BLOCK DIAGRAM 32.768kHz X1 Frequency Divider Oscillator X2 SCL Serial Interface Decoder Control Decode Logic Control Registers Status Register (EEPROM) (SRAM) Timer Calendar Logic Time Keeping Registers (SRAM) 16K EEPROM Array SDA 8 Xicor, Inc. 1994, 1995, 1996, 1997, 1998, 1999 Patents Pending 9900-3003.5 12/6/99 CM 1Hz 1 Characteristics subject to change without notice X1240 PIN CONFIGURATION Figure 1. Recommended Crystal connection X1240 18pF 8 pin SOIC 1 2 X1 X2 NC VSS VBack VCC X1 X2 3 4 8 7 6 5 X1240 8 pin TSSOP 1 8 2 7 3 6 4 5 VCC VBack SCL SDA 10M X1 X2 220K 43pF POWER CONTROL OPERATION SCL SDA VSS NC The Power control circuit accepts a VCC and a VBACK input. The power control circuit will switch to VBACK when VCC < VBACK - 0.2V. It will switch back to VCC when VCC exceeds VBACK. Figure 2. Power Control PIN DESCRIPTIONS Serial Clock (SCL) VCC The SCL input is used to clock all data into and out of the device. The input buffer on this pin is always active (not gated). VBACK Internal Voltage VCC = VBACK -0.2V Serial Data (SDA) SDA is a bidirectional pin used to transfer data into and out of the device. It has an open drain output and may be wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated). REAL TIME CLOCK OPERATION The Real Time Clock (RTC) uses an external, 32.768KHz quartz crystal to maintain an accurate internal representation of the year, month, day, date, hour, minute, and seconds. The RTC has leap-year correction and a century byte. The clock will also correct for months having fewer than 31 days and will have a bit that controls 24 hour or AM/PM format. When the X1240 powers up after the loss of both VCC and VBACK, the clock will not increment until at least one byte is written to the clock register. An open drain output requires the use of a pull-up resistor. The output circuitry controls the fall time of the output signal with the use of a slope controlled pull-down. The circuit is designed for 400kHz 2-wire interface speeds. VBACK This input provides a backup supply voltage to the device. VBACK supplies power to the device in the event the VCC supply fails. Reading the Real Time Clock The RTC is read by initiating a Read command and specifying the address corresponding to the register of the Real Time Clock. The RTC Registers can then be read in a Sequential Read Mode. Since the clock runs continuously and a read takes a finite amount of time, there is the possibility that the clock could change during the course of a read operation. In this device, the time is latched by the read command (falling edge of X1, X2 The X1 and X2 pins are the input and output, respectively, of an inverting amplifier that can be configured for use as an on-chip oscillator. A 32.768kHz quartz crystal is used. Recommeded crystals are Sieko VT-200 or Epson C-002RX. The crystal supplies a timebase for a clock/oscillator. The internal clock can be driven by an external signal on X1, with X2 left unconnected. 2 X1240 the clock on the ACK bit prior to RTC data output) into a separate latch to avoid time changes during the read operation. The clock continues to run. The CCR is divided into 3 sections. These are: 1. Control (2 bytes) 2. Real Time Clock (8 bytes) 3. Status (1 byte) Writing to the Real Time Clock The time and date may be set by writing to the RTC registers. To avoid changing the current time by an uncompleted write operation, the current time value is loaded into a seperate buffer at the falling edge of the clock on the ACK bit before the RTC data input bytes, the clock continues to run. The new serial input data replaces the values in the buffer. This new RTC value is loaded back into the RTC Register by a stop bit at the end of a valid write sequence. An invalid write operation aborts the time update procedure and the contents of the buffer are discarded. After a valid write operation the RTC will reflect the newly loaded data beginning with the first “one second” clock cycle after the stop bit. The RTC continues to update the time while an RTC register write is in progress and the RTC continues to run during any nonvolatile write sequences. A single byte may be written to the RTC without affecting the other bytes. Sections 1) and 2) are nonvolatile and Section 3) is volatile. Each register is read and written through buffers. The non-volatile portion (or the counter portion of the RTC) is updated only if RWEL is set and only after a valid write operation and stop bit. A sequential read or page write operation provides access to the contents of only one section of the CCR per operation. Access to another section requires a new operation. Continued reads or writes, once reaching the end of a section, will wrap around to the start of the section. A read or page write can begin at any address in the CCR. Section 3) is a volatile register. It is not necessary to set the RWEL bit prior to writing the status register. Section 3) supports a single byte read or write only. Continued reads or writes from this section terminates the operation. The state of the CCR can be read by performing a random read at any address in the CCR at any time. This returns the contents of that register location. Additional registers are read by performing a sequential read. The read instruction latches all Clock registers into a buffer, so an update of the clock does not change the time being read. A sequential read of the CCR will not result in the output of data from the memory array. At the end of a read, the master supplies a stop condition to end the operation and free the bus. After a read of the CCR, the address remains at the previous address +1 so the user can execute a current address read of the CCR and continue reading the next Register. CLOCK/CONTROL REGISTERS (CCR) The Control/Clock Registers are located in an area logically separated from the array and are only accessible following a slave byte of “1101111x” and reads or writes to addresses [0000h:003Fh]. CCR access The contents of the CCR can be modified by performing a byte or a page write operation directly to any address in the CCR. Prior to writing to the CCR (except the status register), however, the WEL and RWEL bits must be set using a two step process (See section “Writing to the Clock/Control Registers.”) 3 X1240 Addr. 003F Type Bit Range 7 6 5 4 3 2 1 0 (optional) SR BAT 0 0 0 0 RWEL WEL RTCF 0037 Y2K 0 0 Y2K21 Y2K20 Y2K13 0 0 Y2K10 19/20 0036 DW 0 0 0 0 0 DY2 DY1 DY0 0-6 0035 YR Y23 Y22 Y21 Y20 Y13 Y12 Y11 Y10 0-99 MO 0 0 0 G20 G13 G12 G11 G10 1-12 DT 0 0 D21 D20 D13 D12 D11 D10 1-31 0032 HR MIL 0 H21 H20 H13 H12 H11 H10 0-23 0031 MN 0 M22 M21 M20 M13 M12 M11 M10 0-59 0030 SC 0 S22 S21 S20 S13 S12 S11 S10 0-59 0011 INT 0 0 0 0 0 0 0 0 00h BL BP2 BP1 BP0 0 0 0 0 0 00h 0034 0033 0010 Status Reg Name Factroy Settings Table 1. Clock/Control Memory Map RTC (SRAM) Control (E2PROM) REAL TIME CLOCK REGISTERS Leap Years Leap years add the day February 29 and are defined as those years that are divisible by 4. Years divisible by 100 are not leap years, unless they are also divisible by 400. This means that the year 2000 is a leap year, the year 2100 is not. The X1240 does not correct for the leap year in the year 2100. Year 2000 (Y2K) The X1240 has a century byte that “rolls over” from 19 to 20 when the years byte changes from 99 to 00. The Y2K byte can contain only the values of 19 or 20. Day of the Week Register (DW) This register provides a Day of the Week status and uses three bits DY2 to DY0 to represent the seven days of the week. The counter advances in the cycle 0-1-2-3-4-5-6-0-1-2-... The assignment of a numerical value to a specific day of the week is arbitrary and may be decided by the system software designer. The Clock Default values define 0=Sunday. STATUS REGISTER (SR) The Status Register is located in the RTC area at address 003FH. This is a volatile register only and is used to control the WEL and RWEL write enable latches, and read a Low Voltage Sense bit. This register is logically seperated from both the array and the Clock/Control Registers (CCR). Clock/Calendar Registers (YR, MO, DT, HR, MN, SC) These registers depict BCD representations of the time. As such, SC (Seconds) and MN (Minutes) range from 00 to 59, HR (Hour) is 1 to 12 with an AM or PM indicator (H21 bit) or 0 to 23 (with MIL=1), DT (Date) is 1 to 31, MO (Month) is 1 to 12, YR (year) is 0 to 99. Table 2. Status Register (SR) 24 Hour Time If the MIL bit of the HR register is 1, the RTC will use a 24-hour format. If the MIL bit is 0, the RTC will use 12hour format and bit H21 will function as an AM/PM indicator with a ‘1’ representing PM. The clock defaults to Standard Time with H21=0. Addr 7 6 5 4 3 2 1 0 003Fh BAT 0 0 0 0 RWEL WEL RTCF Default 0 0 0 0 0 0 0 0 BAT: Battery Supply—Volatile This bit set to “1” indicates that the device is operating from VBACK, not VCC. It is a read only bit and is set/ reset by hardware. 4 X1240 RWEL: Register Write Enable Latch—Volatile This bit is a volatile latch that powers up in the LOW (disabled) state. The RWEL bit must be set to “1” prior to any writes to the Clock/Control Registers. Writes to RWEL bit do not cause a nonvolatile write cycle, so the device is ready for the next operation immediately after the stop condition. A write to the CCR requires both the RWEL and WEL bits to be set in a specific sequence. Table 3. Block Protect Bits BP1 BP0 Array Lock BP2 WEL: Write Enable Latch—Volatile The WEL bit controls the access to the CCR and memory array during a write operation. This bit is a volatile latch that powers up in the LOW (disabled) state. While the WEL bit is LOW, writes to the CCR or any array address will be ignored (no acknowledge will be issued after the Data Byte). The WEL bit is set by writing a “1” to the WEL bit and zeroes to the other bits of the Status Register. Once set, WEL remains set until either reset to 0 (by writing a “0” to the WEL bit and zeroes to the other bits of the Status Register) or until the part powers up again. Writes to WEL bit do not cause a non-volatile write cycle, so the device is ready for the next operation immediately after the stop condition. Protected Addresses X1240 0 0 0 None None 0 0 1 600h - 7FFh Upper 1/4 0 1 0 400h - 7FFh Upper 1/2 0 1 1 000h - 7FFh Full Array 1 0 0 000h - 03Fh First Page 1 0 1 000h - 07Fh First 2 pgs 1 1 0 000h - 0FFh First 4 pgs 1 1 1 000h - 1FFh First 8 Pgs WRITING TO THE CLOCK/CONTROL REGISTERS Changing any of the nonvolatile bits of the clock/control register requires the following steps: —Write a 02H to the Status Register to set the Write Enable Latch (WEL). This is a volatile operation, so there is no delay after the write. (Operation preceeded by a start and ended with a stop). RTCF: Real Time Clock Fail Bit—Volatile This bit is set to a ‘1’ after a total power failure. This is a read only bit that is set by hardware when the device powers up after having lost all power to the device. The bit is set regardless of whether VCC or VBACK is applied first. The loss of one or the other supplies does not result in setting the RTCF bit. The first valid write to the RTC (writing one byte is sufficient) resets the RTCF bit to ‘0’. —Write a 06H to the Status Register to set both the Register Write Enable Latch (RWEL) and the WEL bit. This is also a volatile cycle. The zeros in the data byte are required. (Operation preceeded by a start and ended with a stop). —Write one to 8 bytes to the Clock/Control Registers with the desired clock, or control data. This sequence starts with a start bit, requires a slave byte of “11011110” and an address within the CCR and is terminated by a stop bit. A write to the CCR changes EEPROM values so these initiate a nonvolatile write cycle and will take up to 10ms to complete. Writes to undefined areas have no effect. The RWEL bit is reset by the completion of a nonvolatile write write cycle, so the sequence must be repeated to again initiate another change to the CCR contents. If the sequence is not completed for any reason (by sending an incorrect number of bits or sending a start instead of a stop, for example) the RWEL bit is not reset and the device remains in an active mode. Unused Bits: These devices do not use bits 3 through 6, but must have a zero in these bit positions. The Data Byte output during a SR read will contain zeros in these bit locations. CONTROL REGISTERS Block Protect Bits - BP2, BP1, BP0 - (Nonvolatile) The Block Protect Bits, BP2, BP1 and BP0, determine which blocks of the array are write protected. A write to a protected block of memory is ignored. The block protect bits will prevent write operations to one of eight segments of the array. The partitions are described in Table 3. —Writing all zeros to the status register resets both the WEL and RWEL bits. —A read operation occurring between any of the previous operations will not interrupt the register write operation. —The RWEL and WEL bits can be reset by writing a 0 to the Status Register. 5 X1240 SERIAL COMMUNICATION Start Condition Interface Conventions The device supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is called the master and the device being controlled is called the slave. The master always initiates data transfers, and provides the clock for both transmit and receive operations. Therefore, the devices in this family operate as slaves in all applications. All commands are preceded by the start condition, which is a HIGH to LOW transition of SDA when SCL is HIGH. The device continuously monitors the SDA and SCL lines for the start condition and will not respond to any command until this condition has been met. See Figure 3. Stop Condition All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL is HIGH. The stop condition is also used to place the device into the Standby power mode after a read sequence. A stop condition can only be issued after the transmitting device has released the bus Refer to Figure 3. Clock and Data Data states on the SDA line can change only during SCL LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. See Figure 3. Figure 3. Valid Data Changes on the SDA Bus SCL SDA Data Stable Data Change Data Stable Figure 4. Valid Start and Stop Conditions SCL SDA Start Stop 6 X1240 Figure 5. Acknowledge Response From Receiver SCL from Master 1 8 9 Data Output from Transmitter Data Output from Receiver Start Acknowledge Acknowledge Acknowledge is a software convention used to indicate successful data transfer. The transmitting device, either master or slave, will release the bus after transmitting eight bits. During the ninth clock cycle, the receiver will pull the SDA line LOW to acknowledge that it received the eight bits of data. Refer to Figure 5. WRITE OPERATIONS Byte Write For a byte write operation, the device requires the Slave Address Byte and the Word Address Bytes. This gives the master access to any one of the words in the array or CCR. (Note: Prior to writing to the CCR, the master must write a 02h, then 06h to the status register in preceding operations to enable the write operation. See “Writing to the Clock/Control Registers” on page 6.) Upon receipt of each address byte, the X1240 responds with an acknowledge. After receiving both address bytes the X1240 awaits the eight bits of data. After receiving the 8 data bits, the X1240 again responds with an acknowledge. The master then terminates the transfer by generating a stop condition. The X1240 then begins an internal write cycle of the data to the nonvolatile memory. During the internal write cycle, the device inputs are disabled, so the device will not respond to any requests from the master. The SDA output is at high impedance. See Figure 6. The device will respond with an acknowledge after recognition of a start condition and if the correct Device Identifier and Select bits are contained in the Slave Address Byte. If a write operation is selected, the device will respond with an acknowledge after the receipt of each subsequent eight bit word. The device will acknowledge all incoming data and address bytes, except for: —The Slave Address Byte when the Device Identifier and/or Select bits are incorrect —All Data Bytes of a write when the WEL in the Write Protect Register is LOW A write to a protected block of memory is ignored, but will still receive an acknowledge. At the end of the write command, the X1240 will not initiate an internal write cycle, and will continue to ACK commands. —The 2nd Data Byte of a Register Write Operation (when only 1 data byte is allowed) In the read mode, the device will transmit eight bits of data, release the SDA line, then monitor the line for an acknowledge. If an acknowledge is detected and no stop condition is generated by the master, the device will continue to transmit data. The device will terminate further data transmissions if an acknowledge is not detected. The master must then issue a stop condition to return the device to Standby mode and place the device into a known state. 7 X1240 Figure 6. Byte Write Sequence S t a r t Signals from the Master SDA Bus Word Address 1 Slave Address 1 1 11 0 Signals from the Slave Word Address 0 S t o p Data 0000 0 A C K A C K A C K A C K Figure 7. Writing 30 bytes to a 64-byte page starting at adress 40. 7 bytes 23 bytes address pointer ends here Addr = 7 address =6 address 40 address 63 Figure 8. Page Write Sequence Signals from the Master SDA Bus Signals from the Slave S t a r t (1 < n < 64) Word Address 1 Slave Address 1 1 1 10 Word Address 0 Data (1) S t o p Data (n) 0 00 0 0 A C K A C K Page Write The X1240 has a page write operation. It is initiated in the same manner as the byte write operation; but instead of terminating the write cycle after the first data byte is transferred, the master can transmit up to 63 more bytes to the memory array and up to 7 more bytes to the clock/control registers. (Note: Prior to writing to the CCR, the master must write a 02h, then 06h to the status register in two preceding operations to enable the write operation. See “Writing to the Clock/Control Registers” on page 5.) A C K A C K After the receipt of each byte, the X1240 responds with an acknowledge, and the address is internally incremented by one. When the counter reaches the end of the page, it “rolls over” and goes back to the first address on the same page. This means that the master can write 64 bytes to a memory array page or 8 bytes to a CCR section starting at any location on that page. If the master begins writing at location 40 of the memory and loads 30 bytes, then the first 23 bytes are written to addresses 40 through 63, and the last 7 bytes are written to columns 0 through 6. Afterwards, 8 X1240 Figure 9. Acknowledge Polling Sequence the address counter would point to location 7 on the page that was just written. If the master supplies more than the maximum bytes in a page, then the previously loaded data is over written by the new data, one byte at a time. Byte load completed by issuing STOP. Enter ACK Polling The master terminates the Data Byte loading by issuing a stop condition, which causes the device to begin the non-volatile write cycle. As with the byte write operation, all inputs are disabled until completion of the internal write cycle. Refer to Figure 8 for the address, acknowledge, and data transfer sequence. Issue START Issue Slave Address Byte (Read or Write) Stops and Write Modes Stop conditions that terminate write operations must be sent by the master after sending at least 1 full data byte and it’s associated ACK signal. If a stop is issued in the middle of a data byte, or before 1 full data byte + ACK is sent, then the device will reset itself without performing the write. The contents of the array will not be affected. ACK returned? Issue STOP NO YES nonvolatile write Cycle complete. Continue command sequence? Acknowledge Polling The disabling of the inputs during non-volatile write cycles can be used to take advantage of the typical 5mS write cycle time. Once the stop condition is issued to indicate the end of the master’s byte load operation, the device initiates the internal non-volatile write cycle. Acknowledge polling can be initiated immediately. To do this, the master issues a start condition followed by the Slave Address Byte for a write or read operation. If the device is still busy with the non-volatile write cycle then no ACK will be returned. If the device has completed the write operation, an ACK will be returned and the host can then proceed with the read or write operation. Refer to the flow chart in Table 9. NO Issue STOP YES Continue normal Read or Write command sequence PROCEED Upon receipt of the Slave Address Byte with the R/W bit set to one, the device issues an acknowledge and then transmits the eight bits of the Data Byte. The master terminates the read operation when it does not respond with an acknowledge during the ninth clock and then issues a stop condition. Refer to Figure 10 for the address, acknowledge, and data transfer sequence. READ OPERATIONS There are three basic read operations: Current Address Read, Random Read, and Sequential Read. Current Address Read Internally the device contains an address counter that maintains the address of the last word read incremented by one. Therefore, if the last read was to address n, the next read operation would access data from address n+1. On power up, the sixteen bit address is initialized to 0h. In this way, a current address read can be initiated immediately after the power on reset to download the contents of memory starting at the first location. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read operation, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. 9 X1240 Figure 10. Current Address Read Sequence Signals from the Master SDA Bus S t a r t S t o p Slave Address 1 11 11 A C K Signals from the Slave Data newly loaded address. This operation could be useful if the master knows the next address it needs to read, but is not ready for the data. Random Read Random read operation allows the master to access any memory location in the array. Prior to issuing the Slave Address Byte with the R/W bit set to one, the master must first perform a “dummy” write operation. Sequential Read Sequential reads can be initiated as either a current address read or random address read. The first Data Byte is transmitted as with the other modes; however, the master now responds with an acknowledge, indicating it requires additional data. The device continues to output data for each acknowledge received. The master terminates the read operation by not responding with an acknowledge and then issuing a stop condition. The master issues the start condition and the Slave Address Byte, receives an acknowledge, then issues the Word Address Bytes. After acknowledging receipts of the Word Address Bytes, the master immediately issues another start condition and the Slave Address Byte with the R/W bit set to one. This is followed by an acknowledge from the device and then by the eight bit word. The master terminates the read operation by not responding with an acknowledge and then issuing a stop condition. Refer to Figure 11 for the address, acknowledge, and data transfer sequence. The data output is sequential, with the data from address n followed by the data from address n + 1. The address counter for read operations increments through all page and column addresses, allowing the entire memory contents to be serially read during one operation. At the end of the address space the counter “rolls over” to the start of the address space and the device continues to output data for each acknowledge received. Refer to Figure 12 for the acknowledge and data transfer sequence. In a similar operation, called “Set Current Address,” the device sets the address if a stop is issued instead of the second start shown in Figure 11. The X1240 then goes into standby mode after the stop and all bus activity will be ignored until a start is detected. This operation loads the new address into the address counter. The next Current Address Read operation will read from the Figure 11. Random Address Read Sequence Signals from the Master SDA Bus Signals from the Slave S t a r t Slave Address 1 Word Address 0 Word Address 1 1110 S t a r t 0 0 0 00 A C K 1 A C K 10 A C K S t o p Slave Address 111 1 A C K Data X1240 DEVICE ADDRESSING Following the Slave Byte is a two byte word address. The word address is either supplied by the master device or obtained from an internal counter. On power up the internal address counter is set to address 0h, so a current address read of the EEPROM array starts at address 0. When required, as part of a random read, the master device must supply the 2 Word Address Bytes. Following a start condition, the master must output a Slave Address Byte. The first four bits of the Slave Address Byte specify access to the EEPROM array or to the CCR. Slave bits ‘1010’ access the EEPROM array. Slave bits ‘1101’ access the CCR. Bit 3 through Bit 1 of the slave byte specify the device select bits. These are set to ‘111’. In a random read operation, the slave byte in the “dummy write” portion must match the slave byte in the “read” section. That is if the random read is from the array the slave byte must be ‘1010111x’ in both instances. Similarly, for a random read of the Clock/ Control Registers, the slave byte must be ‘1101111x’ in both places. The last bit of the Slave Address Byte defines the operation to be performed. When this R/W bit is a one, then a read operation is selected. A zero selects a write operation. Refer to Figure 12. After loading the entire Slave Address Byte from the SDA bus, the device compares the device identifier and device select bits with ‘1010111’ or ‘1101111’. Upon a correct compare, the device outputs an acknowledge on the SDA line. Figure 12. Sequential Read Sequence Signals from the Master SDA Bus Signals from the Slave Slave Address A C K A C K A C K 1 A C K Data (2) Data (1) 11 Data Data (n-1) (n) (n is any integer greater than 1) S t o p X1240 Figure 13. Slave Address, Word Address, and Data Bytes (64 Byte pages) Device Identifier Array CCR 1 Slave Address Byte Byte 0 0 1 1 0 0 1 1 1 1 0 0 0 0 0 A10 A9 A8 High Order Word Address Byte 1 A7 A6 A5 A4 A3 A2 A1 A0 Low Order Word Address Byte 2 D7 D6 D5 D4 D3 D2 D1 D0 Data Byte Byte 3 1 12 R/W X1240 ABSOLUTE MAXIMUM RATINGS Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Temperature Under Bias .................. -65˚C to +135˚C Storage Temperature ....................... -65˚C to +150˚C Voltage on any pin with respect to ground-1.0V to 7.0V DC Output Current .............................................5 mA Lead Temperature (Soldering, 10 Seconds) .... 300˚C DC OPERATING CHARACTERISTICS (Temperature = -40°c to +85°c, unless otherwise stated.) Symbol Parameter Min Typ Max Unit Notes Vcc Main Power Supply 2.7 3.6 V VBACK Backup Power Supply 1.8 3.6 V VCB Switch to Backup Supply VCC = VBACK -0.2 VBACK -0.1 V (17) VBC Switch to Main Supply VCC = VBACK VBACK +0.1 V (17) ICC1 Read Active Supply Current VCC = 2.7V 400 µA (5), (8), (15) VCC = 3.6V 800 µA VCC = 2.7V 1.5 mA VCC = 3.6V 3.0 mA VCC = 2.7V 1.7 µA VCC = 3.6V 1.5 µA VBACK = 1.8V 1.0 µA VBACK = 3.6V 1.5 µA ICC2 Program Supply Current (nonvolatile) ICC3 Main Timekeeping Current IBACK1 IBACK2 Backup Timekeeping Current Backup Supply Current (External crystal network) (5), (8), (16), (17) (5), (7), (16), (17) (7), (10), (16), (17) VBACK = 1.8V 1.6 3 µA VBACK = 3.6V 7.5 10 µA (7), (10), (16), (17) ILI Input Leakage Current 10 µA (11) ILO Output Leakage Current 10 µA (11) VIL Input LOW Voltage -0.5 VCC x 0.2 or VBACK x 0.2 V (5), (14) VIH Input HIGH Voltage VCC x 0.7 or VBACK x 0.7 VCC + 0.5 VBACK + 0.5 V (5), (14) VHYS Schmitt Trigger Input Hysteresis Vcc related level V (14) VOL Output LOW Voltage VCC = 2.7V 0.4 V (12) VCC = 3.6V 0.4 V (13) VOH Output HIGH Voltage Notes: (1) (2) .05 x VCC or .05 x VBACK VCC = 2.7V 1.6 VCC = 3.6V 2.4 The device enters the Active state after any start, and remains active: for 9 clock cycles if the Device Select Bits in the Slave AddressByte are incorrect or until 200nS after a stop ending a read or write operation. The device enters the Program state 200nS after a stop ending a write operation and continues for t WC. 13 X1240 (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) The device goes into the Timekeeping state 200nS after any stop, except those that initiate a non-volatile write cycle; t WC after a stop that initiates a non-volatile write cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte. For reference only and not tested. VIL = VCC x 0.1, VIH = VCC x 0.9, fSCL = 400KHz, SDA = Open VIL = VCC x 0.1, VIH = VCC x 0.9, fSCL = 400KHz, fSDA = 400KHz, Vcc = 1.22 x Vcc Min VCC = 0V. VBACK= 0V. VSDA=VSCL=VCC, Others=GND or VCC VSDA=VSCL=VBACK, Others=GND or VBACK VSDA = GND to VCC, VCLK = GND or VCC IOL = 3.0mA at 5V, 1.5mA at 2.7V IOH = -1.0mA at 5V, -0.4mA at 2.7V Threshold voltages based on the higher of Vcc or Vback. Driven by external 32.768KHz square wave oscillator on X1, X2 open. Using recommended crystal and oscillator network applied to X1 and X2 (25°C). Periodically sampled and not 100% tested. CAPACITANCE (TA = 25˚C, f = 1.0 MHz, VCC = 5V) Symbol COUT Parameter Max Units Test Conditions (Notes:) Output Capacitance (SDA) 8 pF VOUT = 0V CIN (Notes:) Input Capacitance (SCL) 6 pF VIN = 0V Notes: (1) This parameter is periodically sampled and not 100% tested. AC CHARACTERISTICS AC Test Conditions Input Pulse Levels VCC x 0.1 to VCC x 0.9 Input Rise and Fall Times 10ns Input and Output Timing Levels VCC x 0.5 Output Load Standard Output Load EQUIVALENT AC OUTPUT LOAD CIRCUIT FOR VCC = 5V (Standard Output Load for testing the device with VCC = 5.0V) 5.0V 1533Ω SDA 100pF 14 For VOL= 0.4V and IOL = 3 mA X1240 AC SPECIFICATIONS (TA = -40˚C to +85˚C, VCC = +2.7V to +3.6V, unless otherwise specified.) Symbol Parameter Min Max Units 400 KHz fSCL SCL Clock Frequency 0 tIN Pulse width Suppression Time at inputs 50 tAA SCL LOW to SDA Data Out Valid 0.1 tBUF Time the bus must be free before a new transmission can start 1.3 µS tLOW Clock LOW Time 1.3 µS tHIGH Clock HIGH Time 0.6 µS tSU:STA Start Condition Setup Time 0.6 µS tHD:STA Start Condition Hold Time 0.6 µS tSU:DAT Data In Setup Time 100 nS tHD:DAT Data In Hold Time 0 µS tSU:STO Stop Condition Setup Time 0.6 µS tDH Data Output Hold Time 50 nS tR SDA and SCL Rise Time tF SDA and SCL Fall Time Cb Capacitive load for each bus line nS 0.9 20 +.1Cb(3) 300 nS 20 +.1Cb(3) 300 nS 400 pF Notes: (1) Typical values are for TA = 25˚C and VCC = 5.0V (2) This parameter is periodically sampled and not 100% tested. (3) Cb = total capacitance of one bus line in pF. TIMING DIAGRAMS Bus Timing tF SCL tHIGH tLOW tR tSU:DAT tSU:STA SDA IN tHD:STA tHD:DAT tSU:STO tAA tDH SDA OUT 15 µS tBUF X1240 Write Cycle Timing SCL SDA 8th bit of last byte ACK tWC Stop Condition Start Condition Power Up Timing Symbol Parameter Min. Typ(1) Max. Units tPUR(1) Time from Power Up to Read 1 mS (1) Time from Power Up to Write 5 mS tPUW Notes: (1) Delays are measured from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled and not 100% tested. (2) Typical values are for TA = 25˚C and VCC = 5.0V Nonvolatile Write Cycle Timing Symbol tWC(1) Parameter Min. Write Cycle Time Typ.(1) Max. Units 5 10 mS Notes: (1) tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used. 16 X1240 8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S 0.150 (3.80) 0.158 (4.00) 0.228 (5.80) 0.244 (6.20) PIN 1 INDEX PIN 1 0.014 (0.35) 0.019 (0.49) 0.188 (4.78) 0.197 (5.00) (4X) 7° 0.053 (1.35) 0.069 (1.75) 0.004 (0.19) 0.010 (0.25) 0.050 (1.27) 0.010 (0.25) 0.020 (0.50) X 45° 0.050" TYPICAL 0.050" TYPICAL 0° – 8° 0.0075 (0.19) 0.010 (0.25) 0.250" 0.016 (0.410) 0.037 (0.937) FOOTPRINT NOTE: ALL DIMENSIONS IN INCHES (IN P ARENTHESES IN MILLIMETERS) 17 0.030" TYPICAL 8 PLACES X1240 8-LEAD PLASTIC, TSSOP, PACKAGE TYPE V .025 (.65) BSC .169 (4.3) .252 (6.4) BSC .177 (4.5) .114 (2.9) .122 (3.1) .047 (1.20) .0075 (.19) .0118 (.30) .002 (.05) .006 (.15) .010 (.25) Gage Plane 0° – 8° Seating Plane .019 (.50) .029 (.75) (4.16) (7.72) Detail A (20X) (1.78) .031 (.80) .041 (1.05) (0.42) (0.65) ALL MEASUREMENTS ARE TYPICAL See Detail “A” NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 18 X1240 ORDERING INFORMATION Vcc Range Package 8L SOIC 2.7-3.6V 8L TSSOP Operating Temperature Range Part Number 16Kb EEPROM 0oC – 70oC X1240S8 -40oC – 85oC X1240S8I 0oC – 70oC X1240V8 -40o o X1240V8I C – 85 C Part Mark Information 8Pin PDIP/8-Lead SOIC 8-Lead TSSOP X1240 X XX EYWW XXXXX Blank = 8-Lead SOIC Blank = 2.7 to 3.6V, 0 to +70°C I = 2.7 to 3.6V, -40 to +85°C X1240 = 2.7 to 3.6V, 0 to +70°C X1240I = 2.7 to 3.6V, -40 to +85°C LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied. Copyright 1999. Xicor, Inc. All rights reserved. Printed in the USA. Xicor, Inc. is a registered trademark. All other trademarks or service marks mentioned in this document are the property of their respective owners. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurence. Xicor's products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. 19