EXAR XR16M752IM48

XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
MAY 2007
REV. 1.0.2
GENERAL DESCRIPTION
The XR16M752/XR68M7521 (M752) is a high
performance dual universal asynchronous receiver
and transmitter (UART) with 64 byte TX and RX
FIFOs. The M752 operates from 1.62 to 3.63 volts. It
is pin-to-pin and software compatible to the
TL16C752B and SC16C752B, but with additional
features such as a programmable fractional baud rate
generator, automatic RS-485 half-duplex direction
control, infrared mode and 8X and 4X sampling rate.
The standard features include 16 selectable TX and
RX FIFO trigger levels, automatic hardware (RTS/
CTS) and software (Xon/Xoff) flow control, and a
complete modem interface. Onboard registers
provide the user with operational status and data
error flags. An internal loopback capability allows
system diagnostics. Each channel is independently
programmable for data rates up to 16 Mbps at 3.3
Volt with a 4X sampling rate. The XR68M752 has an
additional 16/68# pin to select between the Intel and
Motorola bus interface. The M752 is available in the
48-pin TQFP and 32-pin QFN packages.
FEATURES
• 1.62 to 3.6 Volt Operation
• Pin-to-pin and software compatible to TI’s
TL16C752B and Philips’ SC16C752B in the 48TQFP package
• Two independent UART channels
NOTE: 1 Covered by U.S. Patent #5,649,122
APPLICATIONS
• Portable Appliances
• Telecommunication Network Routers
• Ethernet Network Routers
• Cellular Data Devices
• Factory Automation and Process Controls
■
Data rate of up to 16 Mbps at 3.3 V
■
Data rate of up to 12.5 Mbps at 2.5 V
■
Data rate of up to 8 Mbps at 1.8 V
■
Fractional Baud Rate Generator
■
Data sampling rates of 16X, 8X and 4X
■
Transmit and Receive FIFOs of 64 bytes
■
Programmable TX and RX FIFO Trigger Levels
■
Automatic Hardware (RTS/CTS) Flow Control
■
Automatic Software (Xon/Xoff) Flow Control
■
Halt and Resume Transmission Control
■
Automatic RS-485 Half-duplex
Control Output via RTS#
■
Wireless Infrared (IrDA 1.0) Encoder/Decoder
■
Automatic sleep mode
■
Full modem interface
Direction
• Crystal oscillator (up to 24MHz) or external clock
(up to 64MHz) input
• 48-TQFP and 32-QFN packages
FIGURE 1. XR16M752 BLOCK DIAGRAM
1.62 to 3.63 Volt VCC
A2:A0
D7:D0
GND
IOR# (NC)
IOW# (R/W#)
UART Channel A
CSA# (CS#)
CSB# (A3)
INTA (IRQ#)
INTB (NC)
TXRDYA#
TXRDYB#
RXRDYA#
RXRDYB#
Reset/Reset#
16/68#
UART
Regs
8-bit Data
Bus
Interface
BRG
64 Byte TX FIFO
TX & RX
IR
ENDEC
TXA, RXA, DTRA#,
DSRA#, RTSA#,
DTSA#, CDA#, RIA#,
OP2A#
64 Byte RX FIFO
UART Channel B
(same as Channel A)
Crystal Osc/Buffer
TXB, RXB, DTRB#,
DSRB#, RTSB#,
CTSB#, CDB#, RIB#,
OP2B#
XTAL1
XTAL2
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
RTSA#
RXA
5
32
OP2A#
TXRDYB#
6
31
RXRDYA#
TXA
7
30
INTA
TXB
8
29
INTB
OP2B#
9
28
A0
CSA#
10
27
A1
CSB#
11
26
A2
NC
12
25
NC
D5
1
36
RESET
D6
2
35
DTRB#
D7
3
34
DTRA#
RXB
4
33
RTSA#
RXA
5
32
OP2A#
TXRDYB#
6
31
RXRDYA #
29 D2
31 D4
TXA
5
21
INTB
20
A0
GND 13
RTSB# 15
CTSB# 16
D0
VCC
CTSA#
27
26
25
IOR# 14
IOW# 12
D1
NC
29 D2
17
28
8
XTAL2 11
A2
CSB#
30 D3
A1
18
NC
19
7
XTAL1 10
6
31 D4
TXB
CSA#
RESET
D6
1
24
D7
2
23
RTSA#
22
INTA
RXB
3
RXA
4
TXA
5
XR68M752
32-pin QFN
Intel Mode
21
INTB
20
A0
A1
16/68#
IOR# 14
CTSB# 16
17
CTSA#
8
25
A2
CSB#
RTSB# 15
18
VCC
19
7
26
6
D0
TXB
CSA#
27
24
16/68#
INTA
XR16M752
32-pin QFN
Intel Mode Only
GND 13
23
CTSB#
22
4
IOW# 12
22
RTSB#
3
RXA
D1
21
DSRA#
CTSA#
NC
38
37
D5
1
36
RESET#
D6
2
35
DTRB#
D7
3
34
DTRA#
D6
1
24
RXB
4
33
RTSA#
D7
2
23
RTSA#
RXA
5
32
OP2A#
RXB
3
22
IRQ#
RXA
4
TXRDYB#
6
31
RXRDYA #
TXA
5
TXA
7
IRQ#
TXB
TXB
8
CS#
A3
18
19
20
21
22
23
24
RXRDYB#
NC
DSRB#
RIB#
RTSB#
CTSB#
16/68#
16/68#
GND
2
NC
CTSB# 16
17
RTSB# 15
A2
8
14
A1
18
12
19
7
GND 13
6
R/W#
NC
17
A2
25
GND
26
12
15
11
16
A3
NC
CDB#
A1
14
A0
27
R/W#
28
10
XTAL2
9
CS#
13
OP2B#
A0
XTAL2 11
NC
NC
20
9
29
RESET#
21
NC
30
XR68M752
32-pin QFN
Motorola Mode
XTAL1 10
XR68M752
48- pin TQFP
Motorola Mode
XTAL1
VCC
VCC
39
CDA#
40
RIB#
RIA#
41
20
VCC
42
DSRB#
TXRDYA#
43
19
D0
44
18
D1
45
IOR#
D2
46
RXRDYB#
D3
47
16
NC
17
A2
25
GND
26
12
CDB#
11
NC
15
CSB #
IOW#
27
13
10
14
RXB
29 D2
A1
CSA #
XTAL2
RTSA#
28
INTB
A0
30 D3
32 D5
29
9
XTAL1
RESET
23
9
INTA
OP2B#
D4
24
2
32 D5
NC
NC
37
23
24
CTSB#
DSRA#
CDA#
40
CTSA#
RIA#
41
38
22
VCC
42
RTSB#
21
TXRDYA#
43
RIB#
19
20
RXRDYB#
IOR#
18
GND
D0
DSRB#
16
17
CDB#
D1
45
44
15
IOW#
D2
46
13
14
XTAL2
D3
XTAL1
D4
48
47
39
30
28
48
1
D7
XTAL2 11
8
D6
30 D3
TXB
DTRB#
9
7
XR68M 752
48- pin TQFP
Intel Mode
RESET
NC
TXA
XR16M752
48-pin TQFP
Intel Mode Only
VCC
33
CTSA#
4
25
DTRA#
RXB
D0
34
26
3
D1
D7
27
35
28
36
2
XTAL1 10
37
1
D6
31 D4
CTSA#
NC
38
D5
32 D5
CDA#
DSRA#
RIA#
41
39
VCC
42
40
D0
TXRDYA#
43
D1
45
44
D3
D2
46
D4
48
47
FIGURE 2. PIN OUT ASSIGNMENT
GND
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
ORDERING INFORMATION
PART NUMBER
PACKAGE
OPERATING TEMPERATURE RANGE
DEVICE STATUS
XR16M752IL32
32-pin QFN
-40°C to +85°C
Active
XR16M752IM48
48-Lead TQFP
-40°C to +85°C
Active
XR68M752IL32
32-pin QFN
-40°C to +85°C
Active
XR68M752IM48
48-Lead TQFP
-40°C to +85°C
Active
PIN DESCRIPTIONS
Pin Description
NAME
32-QFN
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
Address data lines [2:0]. These 3 address lines select one of the internal registers in UART channel A/B during a data bus transaction.
DATA BUS INTERFACE
A2
A1
A0
18
19
20
26
27
28
I
D7
D6
D5
D4
D3
D2
D1
D0
2
1
32
31
30
29
28
27
3
2
1
48
47
46
45
44
I/O
IOR#
(NC)
14
19
I
When 16/68# pin is HIGH, the Intel bus interface is selected and this
input becomes read strobe (active low). The falling edge instigates an
internal read cycle and retrieves the data byte from an internal register
pointed by the address lines [A2:A0], puts the data byte on the data bus
to allow the host processor to read it on the rising edge.
When 16/68# pin is LOW, the Motorola bus interface is selected and
this input is not used.
IOW#
(R/W#)
12
15
I
When 16/68# pin is HIGH, it selects Intel bus interface and this input
becomes write strobe (active low). The falling edge instigates the internal write cycle and the rising edge transfers the data byte on the data
bus to an internal register pointed by the address lines.
When 16/68# pin is LOW, the Motorola bus interface is selected and
this input becomes read (HIGH) and write (LOW) signal.
CSA#
(CS#)
7
10
I
When 16/68# pin is HIGH, this input is chip select A (active low) to
enable channel A in the device.
When 16/68# pin is LOW, this input becomes the chip select (active
low) for the Motorola bus interface.
CSB#
(A3)
8
11
I
When 16/68# pin is HIGH, this input is chip select B (active low) to
enable channel B in the device.
When 16/68# pin is LOW, this input becomes address line A3 which is
used for channel selection in the Motorola bus interface. Input logic 0
selects channel A and logic 1 selects channel B.
Data bus lines [7:0] (bidirectional).
3
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
Pin Description
32-QFN
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
INTA
(IRQ#)
22
30
O
When 16/68# pin is HIGH for Intel bus interface, this output becomes
channel A interrupt output. The output state is defined by the user
through the software setting of MCR[3]. INTA is set to the active mode
and OP2A# output LOW when MCR[3] is set to a logic 1. INTA is set to
the three state mode and OP2A# to HIGH when MCR[3] is set to a logic
0. See MCR[3].
When 16/68# pin is LOW for Motorola bus interface, this output
becomes device interrupt output (active low, open drain). An external
pull-up resistor is required for proper operation.
INTB
(NC)
21
29
O
When 16/68# pin is HIGH for Intel bus interface, this output becomes
channel B interrupt output. The output state is defined by the user
through the software setting of MCR[3]. INTB is set to the active mode
and OP2A# output to LOW when MCR[3] is set to a logic 1. INTA is set
to the three state mode and OP2A# to HIGH when MCR[3] is set to a
logic 0. See MCR[3].
When 16/68# pin is LOW for Motorola bus interface, this output is not
used.
TXRDYA#
-
43
O
UART channel A Transmitter Ready (active low). The output provides
the TX FIFO/THR status for transmit channel A. See Table 3. If it is not
used, leave it unconnected.
RXRDYA#
-
31
O
UART channel A Receiver Ready (active low). This output provides the
RX FIFO/RHR status for receive channel A. See Table 3. If it is not
used, leave it unconnected.
TXRDYB#
-
6
O
UART channel B Transmitter Ready (active low). The output provides
the TX FIFO/THR status for transmit channel B. See Table 4. If it is not
used, leave it unconnected.
RXRDYB#
-
18
O
UART channel B Receiver Ready (active low). This output provides the
RX FIFO/RHR status for receive channel B. See Table 3. If it is not
used, leave it unconnected.
NAME
MODEM OR SERIAL I/O INTERFACE
TXA
5
7
O
UART channel A Transmit Data or infrared encoder data. Standard
transmit and receive interface is enabled when MCR[6] = 0. In this
mode, the TX signal will be HIGH during reset or idle (no data). Infrared
IrDA transmit and receive interface is enabled when MCR[6] = 1. In the
Infrared mode, the inactive state (no data) for the Infrared encoder/
decoder interface is LOW. If it is not used, leave it unconnected.
RXA
4
5
I
UART channel A Receive Data or infrared receive data. Normal receive
data input must idle HIGH. The infrared receiver pulses typically idles at
LOW but can be inverted by software control prior going in to the
decoder, see MCR[6]. If this pin is not used, tie it to VCC or pull it high
via a 100k ohm resistor.
RTSA#
23
33
O
UART channel A Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control,
see EFR[6] and IER[6]. For auto RS485 half-duplex direction control,
see DLD[6].
4
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
Pin Description
NAME
32-QFN
PIN #
48-TQFP
PIN #
TYPE
CTSA#
25
38
I
UART channel A Clear-to-Send (active low) or general purpose input.
It can be used for auto CTS flow control, see EFR[7] and IER[7]. This
input should be connected to VCC or GND when not used.
DTRA#
-
34
O
UART channel A Data-Terminal-Ready (active low) or general purpose
output. If it is not used, leave it unconnected.
DSRA#
-
39
I
UART channel A Data-Set-Ready (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
CDA#
-
40
I
UART channel A Carrier-Detect (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
RIA#
-
41
I
UART channel A Ring-Indicator (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
OP2A#
-
32
O
Output Port 2 Channel A - The output state is defined by the user and
through the software setting of MCR[3]. INTA is set to the active mode
and OP2A# output LOW when MCR[3] is set to a logic 1. INTA is set to
the three state mode and OP2A# output HIGH when MCR[3] is set to a
logic 0. See MCR[3]. If INTA is used, this output should not be used as
a general output else it will disturb the INTA output functionality.
TXB
6
8
O
UART channel B Transmit Data or infrared encoder data. Standard
transmit and receive interface is enabled when MCR[6] = 0. In this
mode, the TX signal will be HIGH during reset or idle (no data). Infrared
IrDA transmit and receive interface is enabled when MCR[6] = 1. In the
Infrared mode, the inactive state (no data) for the Infrared encoder/
decoder interface is LOW. If it is not used, leave it unconnected.
RXB
3
4
I
UART channel B Receive Data or infrared receive data. Normal receive
data input must idle HIGH. The infrared receiver pulses typically idles at
logic 0 but can be inverted by software control prior going in to the
decoder, see MCR[6]. If this pin is not used, tie it to VCC or pull it high
via a 100k ohm resistor.
RTSB#
15
22
O
UART channel B Request-to-Send (active low) or general purpose output. This port must be asserted prior to using auto RTS flow control,
see EFR[6] and IER[6]. For auto RS485 half-duplex direction control,
see DLD[6].
CTSB#
16
23
I
UART channel B Clear-to-Send (active low) or general purpose input.
It can be used for auto CTS flow control, see EFR[7] and IER[7]. This
input should be connected to VCC or GND when not used.
DTRB#
-
35
O
UART channel B Data-Terminal-Ready (active low) or general purpose
output. If it is not used, leave it unconnected.
DSRB#
-
20
I
UART channel B Data-Set-Ready (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
CDB#
-
16
I
UART channel B Carrier-Detect (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
RIB#
-
21
I
UART channel B Ring-Indicator (active low) or general purpose input.
This input should be connected to VCC or GND when not used.
DESCRIPTION
5
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
Pin Description
NAME
32-QFN
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
OP2B#
-
9
O
Output Port 2 Channel B - The output state is defined by the user and
through the software setting of MCR[3]. INTB is set to the active mode
and OP2B# output LOW when MCR[3] is set to a logic 1. INTB is set to
the three state mode and OP2B# output HIGH when MCR[3] is set to a
logic 0. See MCR[3]. If INTB is used, this output should not be used as
a general output else it will disturb the INTB output functionality.
ANCILLARY SIGNALS
XTAL1
10
13
I
Crystal or external clock input.
XTAL2
11
14
O
Crystal or buffered clock output.
16/68#
17
24
I
Intel or Motorola Bus Select (internal pull-up resistor). This pin is not
available for the XR16M752. This pin is available for the XR68M752
only.
When 16/68# pin is HIGH, 16 or Intel Mode, the device will operate in
the Intel bus type of interface.
When 16/68# pin is LOW, 68 or Motorola mode, the device will operate
in the Motorola bus type of interface.
RESET
(RESET#)
24
36
I
When 16/68# pin is HIGH for Intel bus interface, this input becomes
RESET (active high). When 16/68# pin is LOW for Motorola bus interface, this input becomes RESET# (active low).
A 40 ns minimum active pulse on this pin will reset the internal registers
and all outputs of channel A and B. The UART transmitter output will be
held HIGH, the receiver input will be ignored and outputs are reset during reset period (see Table 16).
VCC
26
42
Pwr
1.62V to 3.63V power supply.
GND
13
17
Pwr
Power supply common, ground.
GND
Center Pad
-
Pwr
The center pad on the backside of the QFN package is metallic and
should be connected to GND on the PCB. The thermal pad size on the
PCB should be the approximate size of this center pad and should be
solder mask defined. The solder mask opening should be at least
0.0025" inwards from the edge of the PCB thermal pad.
NC
9
12, 25, 37
No Connection.
Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain.
6
XR16M752/XR68M752
REV. 1.0.2
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
1.0 PRODUCT DESCRIPTION
The XR16M752/XR68M752 (M752) integrates the functions of 2 enhanced 16C550 Universal Asynchronous
Receiver and Transmitter (UART). Each UART is independently controlled having its own set of device
configuration registers. The configuration registers set is 16550 UART compatible for control, status and data
transfer. Additionally, each UART channel has 64-bytes of transmit and receive FIFOs, automatic RTS/CTS
hardware flow control, automatic Xon/Xoff and special character software flow control, programmable transmit
and receive FIFO trigger levels, infrared encoder and decoder (IrDA ver 1.0), programmable fractional baud
rate generator with a prescaler of divide by 1 or 4, and data rate up to 16 Mbps with 4X sampling clock rate.
The XR16M752 is a 1.62V to 3.63V device. The M752 is fabricated with an advanced CMOS process.
Enhanced Features
The M752 DUART provides a solution that supports 64 bytes of transmit and receive FIFO memory, instead of
16 bytes in the industry standard 16C550. The M752 is designed to work with low supply voltage and high
performance data communication systems, that require fast data processing time. Increased performance is
realized in the M752 by the larger transmit and receive FIFOs, FIFO trigger level control and automatic flow
control mechanism. This allows the external processor to handle more networking tasks within a given time.
For example, the 16C550 with a 16 byte FIFO, unloads 16 bytes of receive data in 1.53 ms (This example uses
a character length of 11 bits, including start/stop bits at 115.2 Kbps). This means the external CPU will have to
service the receive FIFO at 1.53 ms intervals. However with the 64 byte FIFO in the M752, the data buffer will
not require unloading/loading for 6.1 ms. This increases the service interval giving the external CPU additional
time for other applications and reducing the overall UART interrupt servicing time. In addition, the
programmable FIFO level trigger interrupt and automatic hardware/software flow control is uniquely provided
for maximum data throughput performance especially when operating in a multi-channel system. The
combination of the above greatly reduces the CPU’s bandwidth requirement, increases performance, and
reduces power consumption.
The M752 supports a half-duplex output direction control signaling pin, RTS# A/B, to enable and disable the
external RS-485 transceiver operation. It automatically switches the logic state of the output pin to the receive
state after the last stop-bit of the last character has been shifted out of the transmitter. After receiving, the logic
state of the output pin switches back to the transmit state when a data byte is loaded in the transmitter. The
auto RS-485 direction control pin is not activated after reset. To activate the direction control function, user has
to set DLD Bit-6 to “1”. This pin is HIGH for receive state and LOW for transmit state.
Data Rate
The M752 is capable of operation up to 16 Mbps at 3.3V with 4X internal sampling clock rate, 8 Mbps at 3.3V
with 8X sampling clock rate, and 4 Mbps at 3.3V with 16X internal sampling clock rate. The device can operate
with an external 24 MHz crystal on pins XTAL1 and XTAL2, or external clock source of up to 64 MHz on XTAL1
pin. With a typical crystal of 14.7456 MHz and through a software option, the user can set the prescaler bit for
data rates of up to 3.68 Mbps.
The rich feature set of the M752 is available through the internal registers. Automatic hardware/software flow
control, programmable transmit and receive FIFO trigger levels, programmable TX and RX baud rates, infrared
encoder/decoder interface, modem interface controls, and a sleep mode are all standard features.
Following a power on reset or an external reset, the M752 is software compatible with previous generation of
UARTs, 16C450, 16C550 and 16C2550.
7
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
2.0 FUNCTIONAL DESCRIPTIONS
2.1
CPU Interface
The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and
write transactions. The XR16M752 data interface supports the Intel compatible types of CPUs while the
XR68M752 supports both the Intel and Motorola compatible data interfaces. No clock (oscillator nor external
clock) is required to operate a data bus transaction. Each bus cycle is asynchronous using CS#, IOR# and
IOW# signals. Both UART channels share the same data bus for host operations. The data bus
interconnections are shown in Figure 3.
FIGURE 3. XR16M752/XR68M752 DATA BUS INTERCONNECTIONS
VCC
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
A0
A1
A2
A0
A1
DSRA#
A2
RIA#
OP2A#
IO R#
IOR #
IO W #
IOW #
RXA
UART
Channel A
UART_INTA
INTA
UART_INTB
INTB
TXRDYA#
RXRDYA#
TXRDYB#
TXRDYB#
RXRDYB#
RXRDYB#
UART_RESET
CTSA#
Serial Interface of
RS-232, RS-422
or RS-485
(no connect)
TXB
RXB
UART
Channel B
TXRDYA#
RXRDYA#
DTRA#
RTSA#
CDA#
CSA#
CSB#
UART_CSA#
UART_CSB#
VCC
TXA
DTRB#
RTSB#
CTSB#
DSRB#
CDB#
RIB#
OP2B#
RESET
Serial Interface of
RS-232, RS-422
or RS-485
(no connect)
GND
Intel Data Bus Interconnections
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
A0
A1
A2
A0
A1
A3
CSB#
VCC
RXA
UART
Channel A
DTRA#
RTSA#
CTSA#
DSRA#
A2
Serial Interface of
RS-232, RS-422
or RS-485
CDA#
RIA#
OP2A#
IOR #
VCC
2.25 to 3.6 Volt VCC
TXA
(no connect)
IOW #
R/W #
TXB
UART_CS#
CSA#
VCC
UART_IRQ#
INTA
(no connect)
RXB
UART
Channel B
INTB
DTRB#
RTSB#
CTSB#
DSRB#
TXRDYA#
CDB#
RXRDYA#
RXRDYA#
TXRDYB#
TXRDYB#
RIB#
OP2B#
RXRDYB#
RXRDYB#
TXRDYA#
UART_RESET#
RESET #
M otorola Data Bus Interconnections
8
G ND
Serial Interface of
RS-232, RS-422
or RS-485
(no connect)
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
2.2
Device Reset
The RESET input resets the internal registers and the serial interface outputs in both channels to their default
state (see Table 16). An active high pulse of longer than 40 ns duration will be required to activate the reset
function in the device.
2.3
Channel A and B Selection
The UART provides the user with the capability to bi-directionally transfer information between an external
CPU and an external serial communication device. During Intel Bus Mode (16/68# pin connected to VCC), a
logic 0 on chip select pins, CSA# or CSB#, allows the user to select UART channel A or B to configure, send
transmit data and/or unload receive data to/from the UART. Selecting both UARTs can be useful during power
up initialization to write to the same internal registers, but do not attempt to read from both UARTs
simultaneously. Individual channel select functions are shown in Table 1.
TABLE 1: CHANNEL A AND B SELECT IN 16 MODE
CSA#
CSB#
FUNCTION
1
1
UART de-selected
0
1
Channel A selected
1
0
Channel B selected
0
0
Channel A and B selected
During Motorola Bus Mode (16/68# pin connected to GND), the package interface pins are configured for
connection with Motorola, and other popular microprocessor bus types. In this mode the M752 decodes an
additional address, A3, to select one of the UART ports. The A3 address decode function is used only when in
the Motorola Bus Mode. See Table 2.
TABLE 2: CHANNEL A AND B SELECT IN 68 MODE
2.4
CS#
A3
FUNCTION
1
N/A
UART de-selected
0
0
Channel A selected
0
1
Channel B selected
Channel A and B Internal Registers
Each UART channel in the M752 has a set of enhanced registers for control, monitoring and data loading and
unloading. The configuration register set is compatible to those already available in the standard single
16C550 and dual ST16C2550. These registers function as data holding registers (THR/RHR), interrupt status
and control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/
LCR), modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/
DLM/DLD), and a user accessible Scratchpad Register (SPR).
Beyond the general 16C550 features and capabilities, the M752 offers enhanced feature registers (EFR, Xon/
Xoff 1, Xon/Xoff 2, TCR, TLR and DLD) that provide automatic RTS and CTS hardware flow control, Xon/Xoff
software flow control, automatic RS-485 half-duplex direction output enable/disable, and programmable FIFO
trigger level control. All the register functions are discussed in full detail later in “Section 3.0, UART Internal
Registers” on page 22.
9
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
2.5
REV. 1.0.2
DMA Mode
The device does not support direct memory access. The DMA Mode (a legacy term) in this document doesn’t
mean “direct memory access” but refers to data block transfer operation. The DMA mode affects the state of
the RXRDY# A/B and TXRDY# A/B output pins. The transmit and receive FIFO trigger levels provide additional
flexibility to the user for block mode operation. The LSR bits 5-6 provide an indication when the transmitter is
empty or has an empty location(s) for more data. The user can optionally operate the transmit and receive
FIFO in the DMA mode (FCR bit-3=1). When the transmit and receive FIFO are enabled and the DMA mode is
disabled (FCR bit-3 = 0), the M752 is placed in single-character mode for data transmit or receive operation.
When DMA mode is enabled (FCR bit-3 = 1), the user takes advantage of block mode operation by loading or
unloading the FIFO in a block sequence determined by the programmed trigger level. In this mode, the M752
sets the TXRDY# pin when the transmit FIFO becomes full, and sets the RXRDY# pin when the receive FIFO
becomes empty. The following table shows their behavior. Also see Figures 19 through 24.
TABLE 3: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE
PINS
FCR BIT-0=0
(FIFO DISABLED)
FCR BIT-0=1 (FIFO ENABLED)
FCR Bit-3 = 0
(DMA Mode Disabled)
RXRDY# A/B LOW = 1 byte.
HIGH = no data.
LOW = at least 1 byte in FIFO.
HIGH = FIFO empty.
TXRDY# A/B LOW = THR empty. LOW = FIFO empty.
HIGH = byte in THR. HIGH = at least 1 byte in FIFO.
2.6
FCR Bit-3 = 1
(DMA Mode Enabled)
HIGH to LOW transition when FIFO reaches the
trigger level, or time-out occurs.
LOW to HIGH transition when FIFO empties or
LSR[7] = 1.
LOW = FIFO is below the trigger level.
HIGH = FIFO is full.
INTA and INTB Outputs
The INTA and INTB interrupt output changes according to the operating mode and enhanced features setup.
Table 4 and 5 summarize the operating behavior for the transmitter and receiver. Also see Figures 19
through 24.
TABLE 4: INTA AND INTB PINS OPERATION FOR TRANSMITTER
Auto RS485
Mode
FCR BIT-0 = 0
(FIFO DISABLED)
FCR BIT-0 = 1 (FIFO ENABLED)
INTA/B Pin
NO
LOW = a byte in THR
HIGH = THR empty
LOW = FIFO above trigger level
HIGH = FIFO below trigger level or FIFO empty
INTA/B Pin
YES
LOW = a byte in THR
HIGH = transmitter empty
LOW = FIFO above trigger level
HIGH = FIFO below trigger level or transmitter empty
TABLE 5: INTA AND INTB PIN OPERATION FOR RECEIVER
FCR BIT-0 = 0
(FIFO DISABLED)
INTA/B Pin
LOW = no data
HIGH = 1 byte
FCR BIT-0 = 1
(FIFO ENABLED)
LOW = FIFO below trigger level
HIGH = FIFO above trigger level
10
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
2.7
Crystal Oscillator or External Clock Input
The M752 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the
device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a
system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the
oscillator or external clock buffer input with XTAL2 pin being the output. Please note that the input XTAL1 is not
5V tolerant and so the maximum at the pin should be VCC. For programming details, see ““Section 2.8,
Programmable Baud Rate Generator with Fractional Divisor” on page 11.”
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS
XTAL1
XTAL2
R2
500 ΚΩ − 1 ΜΩ
Y1
C1
22-47 pF
R1
0-120 Ω
(Optional)
1.8432 MHz
to
24 MHz
C2
22-47 pF
The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant,
fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100 ppm frequency
tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud
Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an
external clock input on XTAL1 pin, it can extend its operation up to 64 MHz (16 Mbps serial data rate) at 3.3V
with an 4X sampling rate. For further reading on the oscillator circuit please see the Application Note DAN108
on the EXAR web site at http://www.exar.com.
2.8
Programmable Baud Rate Generator with Fractional Divisor
Each UART has its own Baud Rate Generator (BRG) with a prescaler for the transmitter and receiver. The
prescaler is controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescaler to divide
the input crystal or external clock by 1 or 4. The output of the prescaler clocks to the BRG. The BRG further
divides this clock by a programmable divisor between 1 and (216 - 0.0625) in increments of 0.0625 (1/16) to
obtain a 16X, 8X or 4X sampling clock of the serial data rate. The sampling clock is used by the transmitter for
data bit shifting and receiver for data sampling. The BRG divisor (DLL, DLM and DLD registers) defaults to the
value of ’1’ (DLL = 0x01, DLM = 0x00 and DLD = 0x00) upon reset. Therefore, the BRG must be programmed
during initialization to the operating data rate. The DLL and DLM registers provide the integer part of the divisor
and the DLD register provides the fractional part of the dvisior. The four lower bits of the DLD are used to select
a value from 0 (for setting 0000) to 0.9375 or 15/16 (for setting 1111). Programming the Baud Rate Generator
Registers DLL, DLM and DLD provides the capability for selecting the operating data rate. Table 6 shows the
standard data rates available with a 24MHz crystal or external clock at 16X clock rate. If the pre-scaler is used
(MCR bit-7 = 1), the output data rate will be 4 times less than that shown in Table 6. At 8X sampling rate, these
data rates would double and at 4X sampling rate, these data rates would quadruple. Also, when using 8X
sampling mode, the bit time will have a jitter of ± 1/16 whenever the DLD is non-zero and is an odd number.
11
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
When using 4X sampling mode, the bit time will have a jitter of ± 1/8 whenever DLD is non-zero, odd and not a
multiple of 4. When using a non-standard data rate crystal or external clock, the divisor value can be calculated
with the following equation(s):
Required Divisor (decimal)=(XTAL1 clock frequency / prescaler) /(serial data rate x 16), with 16X mode, DLD[5:4]=’00’
Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 8), with 8X mode, DLD[5:4] = ’01’
Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 4), with 4X mode, DLD[5:4] = ’10’
The closest divisor that is obtainable in the M752 can be calculated using the following formula:
ROUND( (Required Divisor - TRUNC(Required Divisor) )*16)/16 + TRUNC(Required Divisor), where
DLM = TRUNC(Required Divisor) >> 8
DLL = TRUNC(Required Divisor) & 0xFF
DLD = ROUND( (Required Divisor-TRUNC(Required Divisor) )*16)
In the formulas above, please note that:
TRUNC (N) = Integer Part of N. For example, TRUNC (5.6) = 5.
ROUND (N) = N rounded towards the closest integer. For example, ROUND (7.3) = 7 and ROUND (9.9) = 10.
A >> B indicates right shifting the value ’A’ by ’B’ number of bits. For example, 0x78A3 >> 8 = 0x0078.
FIGURE 5. BAUD RATE GENERATOR
To Other
Channel
DLL, DLM and DLD
Registers
Prescaler
Divide by 1
XTAL1
XTAL2
Crystal
Osc/
Buffer
Prescaler
Divide by 4
12
MCR Bit-7=0
(default)
Fractional Baud
Rate Generator
Logic
MCR Bit-7=1
16X or 8X or 4X
Sampling
Rate Clock
to Transmitter
and Receiver
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE 6: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING
Required
Output Data
Rate
DIVISOR FOR
16x Clock
(Decimal)
DIVISOR
OBTAINABLE IN
M752
DLM PROGRAM
VALUE (HEX)
DLL PROGRAM
VALUE (HEX)
DLD PROGRAM
VALUE (HEX)
DATA ERROR
RATE (%)
400
3750
3750
E
A6
0
0
2400
625
625
2
71
0
0
4800
312.5
312 8/16
1
38
8
0
9600
156.25
156 4/16
0
9C
4
0
10000
150
150
0
96
0
0
19200
78.125
78 2/16
0
4E
2
0
25000
60
60
0
3C
0
0
28800
52.0833
52 1/16
0
34
1
0.04
38400
39.0625
39 1/16
0
27
1
0
50000
30
30
0
1E
0
0
57600
26.0417
26 1/16
0
1A
1
0.08
75000
20
20
0
14
0
0
100000
15
15
0
F
0
0
115200
13.0208
13
0
D
0
0.16
153600
9.7656
9 12/16
0
9
C
0.16
200000
7.5
7 8/16
0
7
8
0
225000
6.6667
6 11/16
0
6
B
0.31
230400
6.5104
6 8/16
0
6
8
0.16
250000
6
6
0
6
0
0
300000
5
5
0
5
0
0
400000
3.75
3 12/16
0
3
C
0
460800
3.2552
3 4/16
0
3
4
0.16
500000
3
3
0
3
0
0
750000
2
2
0
2
0
0
921600
1.6276
1 10/16
0
1
A
0.16
1000000
1.5
1 8/16
0
1
8
0
2.9
Transmitter
The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 64 bytes of FIFO which
includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X/4X
internal clock. A bit time is 16 (8 if 8X or 4 if 4X) clock periods (see DLD[5:4]). The transmitter sends the startbit followed by the number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The
status of the FIFO and TSR are reported in the Line Status Register (LSR[6:5]).
13
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
2.9.1
REV. 1.0.2
Transmit Holding Register (THR) - Write Only
The transmit holding register is an 8-bit register providing a data interface to the host processor. The host
writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits,
parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input
register to the transmit FIFO of 64 bytes when FIFO operation is enabled by FCR bit-0. Every time a write
operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data
location.
2.9.2
Transmitter Operation in non-FIFO Mode
The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the
data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled
by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty.
FIGURE 6. TRANSMITTER OPERATION IN NON-FIFO MODE
Transmit
Holding
Register
(THR)
Data
Byte
16X or 8X or 4X
Clock
( DLD[5:4] )
THR Interrupt (ISR bit-1)
Enabled by IER bit-1
Transmit Shift Register (TSR)
M
S
B
L
S
B
TXNOFIFO1
2.9.3
Transmitter Operation in FIFO Mode
The host may fill the transmit FIFO with up to 64 bytes of transmit data. The THR empty flag (LSR bit-5) is set
whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the
amount of data in the FIFO falls below its programmed trigger level. The transmit empty interrupt is enabled by
IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty.
FIGURE 7. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE
Transmit
Data Byte
Transmit
FIFO
THR Interrupt (ISR bit-1) falls
below the programmed Trigger
Level and then when becomes
empty. FIFO is Enabled by FCR
bit-0=1
Auto CTS Flow Control (CTS# pin)
Flow Control Characters
(Xoff1/2 and Xon1/2 Reg.)
Auto Software Flow Control
16X or 8X or 4X Clock
( DLD[5:4] )
Transm it Data Shift Register
(TSR)
TXFIFO 1
14
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
2.10
Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and 64 bytes of FIFO which includes a
byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X/4X clock (DLD [5:4]) for timing. It
verifies and validates every bit on the incoming character in the middle of each data bit. On the falling edge of
a start or false start bit, an internal receiver counter starts counting at the 16X/8X/4X clock rate. After 8 clocks
(or 4 if 8X or 2 if 4X) the start bit period should be at the center of the start bit. At this time the start bit is
sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from
assembling a false character. The rest of the data bits and stop bits are sampled and validated in this same
manner to prevent false framing. If there were any error(s), they are reported in the LSR register bits 2-4. Upon
unloading the receive data byte from RHR, the receive FIFO pointer is bumped and the error tags are
immediately updated to reflect the status of the data byte in RHR register. RHR can generate a receive data
ready interrupt upon receiving a character or delay until it reaches the FIFO trigger level. Furthermore, data
delivery to the host is guaranteed by a receive data ready time-out interrupt when data is not received for 4
word lengths as defined by LCR[1:0] plus 12 bits time. This is equivalent to 3.7-4.6 character times. The RHR
interrupt is enabled by IER bit-0.
2.10.1
Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift
Register. It provides the receive data interface to the host processor. The RHR register is part of the receive
FIFO of 64 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When
the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the
RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data
byte are immediately updated in the LSR bits 2-4.
FIGURE 8. RECEIVER OPERATION IN NON-FIFO MODE
16X or 8X or 4X C lock
( D LD[5:4] )
R eceive
D ata B yte
and E rrors
R eceive D ata S hift
R egister (R S R )
E rror
Tags in
LS R bits
4:2
R eceive D ata
H olding R egister
(R H R)
D ata Bit
V alidation
R eceive D ata C haracters
R H R Interrupt (ISR bit-2)
R XFIFO 1
15
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 9. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
16X or 8X or 4X Clock
( DLD[5:4] )
Receive Data Shift
Register (RSR)
Data Bit
Validation
64 bytes by 11-bit wide
FIFO
Error Tags
(64-sets)
Data falls to
Resume Level
Receive
Data FIFO
FIFO
Trigger=16
Error Tags in
LSR bits 4:2
Data fills to
Halt Level
Receive Data
Byte and Errors
Receive Data Characters
Example
: - RX FIFO trigger level selected at 16 bytes
(See Note Below)
RTS# re-asserts when data falls to the Resume
Level to restart remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills to the Halt Level
to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
Receive
Data
RXFIFO1
2.11
Auto RTS (Hardware) Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see Figure 10):
• Enable auto RTS flow control using EFR bit-6.
• The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If using the Auto RTS interrupt:
• Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.12
Auto RTS Halt and Resume
The RTS# pin will not be forced HIGH (RTS off) until the receive FIFO reaches the Halt Level (TCR[3:0]). The
RTS# pin will return LOW after the RX FIFO is unloaded to the Resume Level (TCR[7:4]). Under these
conditions, the M752 will continue to accept data if the remote UART continues to transmit data. It is the
responsibility of the user to ensure that the Halt Level is greater than the Resume Level. If interrupts are used,
it is recommended that Halt Level > RX Trigger Level > Resume Level. The Auto RTS function is initiated
when the RTS# output pin is asserted LOW (RTS On).
2.13
Auto RS485 Half-duplex Control
The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by DLD
bit-6. It also changes the behavior of the transmit empty interrupt (see Table 4). When idle, the auto RS485
half-duplex direction control signal (RTS#) is LOW for receive mode. When data is loaded into the THR for
transmission, the RTS# output is automatically asserted HIGH prior to sending the data. After the last stop bit
of the last character that has been transmitted, the RTS# signal is automatically de-asserted. This helps in
turning around the transceiver to receive the remote station’s response. When the host is ready to transmit
next polling data packet, it only has to load data bytes to the transmit FIFO. The transmitter automatically reasserts RTS# (HIGH) output prior to sending the data.
16
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
2.14
Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 10):
• Enable auto CTS flow control using EFR bit-7.
If using the Auto CTS interrupt:
• Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as
the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is reasserted (LOW), indicating more data may be sent.
FIGURE 10. AUTO RTS AND CTS FLOW CONTROL OPERATION
Local UART
UARTA
Remote UART
UARTB
RXA
Receiver FIFO
Trigger Reached
RTSA#
Auto RTS
Trigger Level
Receiver FIFO
Trigger Reached
RTSB#
Assert RTS# to Begin
Transmission
1
ON
Auto RTS
Trigger Level
10
OFF
ON
7
2
CTSB#
Auto CTS
Monitor
RXB
CTSA#
Auto CTS
Monitor
Transmitter
CTSB#
TXA
Transmitter
RTSA#
TXB
ON
3
8
OFF
6
Suspend
11
ON
TXB
Data Starts
4
Restart
9
RXA FIFO
INTA
(RXA FIFO
Interrupt)
Receive
RX FIFO
Data
Trigger Level
5
RTS High
Threshold
RTS Low
Threshold
12
RX FIFO
Trigger Level
RTSCTS1
The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of
remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO
(4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA
monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows
(7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9),
UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until
next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB
with RTSB# and CTSA# controlling the data flow.
17
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
2.15
REV. 1.0.2
Auto Xon/Xoff (Software) Flow Control
When software flow control is enabled (See Table 15), the M752 compares one or two sequential receive data
characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the M752 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the M752 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the M752 will resume operation
and clear the flags (ISR bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to 0x00. Following reset the user can
write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/Xoff
characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are
selected, the M752 compares two consecutive receive characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control
mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed, the M752 automatically
sends the Xoff-1,2 via the serial TX output to the remote modem when the RX FIFO reaches the Halt Level
(TCR[3:0]). To clear this condition, the M752 will transmit the programmed Xon-1,2 characters as soon as RX
FIFO falls down to the Resume Level.
2.16
Special Character Detect
A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced
Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal
incoming RX data.
The M752 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will
be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal
Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is
dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of
character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also
determines the number of bits that will be used for the special character comparison.
2.17
Infrared Mode
The M752 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association)
version 1.0. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGHpulse for each “0” bit in the transmit data stream. This signal encoding reduces the on-time of the infrared LED,
hence reduces the power consumption. See Figure 11 below.
The infrared encoder and decoder are enabled by setting DLD register bit-7 to a ‘1’. When the infrared feature
is enabled, the transmit data output, TX, idles LOW. Likewise, the RX input also idles LOW, see Figure 11.
The wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin. Each
time it senses a light pulse, it returns a logic 1 to the data bit stream.
18
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 11. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING
Character
TX Data
0
1
0
1
0
Stop
Start
Data Bits
1
0
1
1
0
Transmit
IR Pulse
(TX Pin)
1/2 Bit Time
Bit Time
3/16 Bit Time
IrEncoder-1
Receive
IR Pulse
(RX pin)
Bit Time
1/16 Clock Delay
1
0
1
0
0
1 1
0
Data Bits
1
Stop
0
Start
RX Data
Character
IRdecoder-
2.18
Sleep Mode with Auto Wake-Up
The M752 supports low voltage system designs, hence, a sleep mode is included to reduce its power
consumption when the chip is not actively used.
All of these conditions must be satisfied for the M752 to enter sleep mode:
■
no interrupts pending for both channels of the M752 (ISR bit-0 = 1)
■
sleep mode of both channels are enabled (IER bit-4 = 1)
■
modem inputs are not toggling (MSR bits 0-3 = 0)
■
RX input pins are idling HIGH
The M752 stops its crystal oscillator to conserve power in the sleep mode. User can check the XTAL2 pin for
no clock output as an indication that the device has entered the sleep mode.
The M752 resumes normal operation by any of the following:
■
a receive data start bit transition (HIGH to LOW)
■
a data byte is loaded to the transmitter, THR or FIFO
■
a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI#
If the M752 is awakened by any one of the above conditions, it will return to the sleep mode automatically after
all interrupting conditions have been serviced and cleared. If the M752 is awakened by the modem inputs, a
read to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while
an interrupt is pending from channel A or B. The M752 will stay in the sleep mode of operation until it is
disabled by setting IER bit-4 to a logic 0.
19
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
If the address lines, data bus lines, IOW#, IOR#, CSA#, CSB#, and modem input lines remain steady when the
M752 is in sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical
Characteristics on page 38. If the input lines are floating or are toggling while the M752 is in sleep mode, the
current can be up to 100 times more. If any of those signals are toggling or floating, then an external buffer
would be required to keep the address, data and control lines steady to achieve the low current. As an
alternative, please refer to the XR16L2751 which is pin-to-pin and software compatible with the M752 but with
(some additional pins and) the PowerSave feature that eliminates any unnecessary external buffer.
A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the
first few receive characters may be lost. The number of characters lost during the restart also depends on your
operating data rate. More characters are lost when operating at higher data rate. Also, it is important to keep
RX A/B inputs idling HIGH or “marking” condition during sleep mode to avoid receiving a “break” condition
upon the restart. This may occur when the external interface transceivers (RS-232, RS-485 or another type)
are also put to sleep mode and cannot maintain the “marking” condition. To avoid this, the designer can use a
47k-100k ohm pull-up resistor on the RXA and RXB pins.
2.19
Internal Loopback
The M752 UART provides an internal loopback capability for system diagnostic purposes. The internal
loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally.
Figure 12 shows how the modem port signals are re-configured. Transmit data from the transmit shift register
output is internally routed to the receive shift register input allowing the system to receive the same data that it
was sending. The TX, RTS# and DTR# pins are held while the CTS#, DSR# CD# and RI# inputs are ignored.
Caution: the RX input pin must be held HIGH during loopback test else upon exiting the loopback test the
UART may detect and report a false “break” signal. Also, Auto RTS/CTS flow control is not supported during
internal loopback.
20
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 12. INTERNAL LOOP BACK IN CHANNEL A AND B
VCC
TXA/TXB
Transmit Shift Register
(THR/FIFO)
Receive Shift Register
(RHR/FIFO)
RXA/RXB
VCC
RTSA#/RTSB#
RTS#
Modem / General Purpose Control Logic
Internal Data Bus Lines and Control Signals
MCR bit-4=1
CTS#
CTSA#/CTSB#
VCC
DTRA#/DTRB#
DTR#
DSR#
DSRA#/DSRB#
OP1#
RI#
VCC
RIA#/RIB#
OP2A#/OP2B#
OP2#
CD#
CDA#/CDB#
21
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
3.0 UART INTERNAL REGISTERS
Each of the UART channel in the M752 has its own set of configuration registers selected by address lines A0,
A1 and A2 with CSA# or CSB# selecting the channel. The complete register set is shown on Table 7 and
Table 8.
TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS
ADDRESSES
A2 A1 A0
REGISTER
READ/WRITE
COMMENTS
LCR[7] = 0
16C550 COMPATIBLE REGISTERS
0
0 0
RHR - Receive Holding Register
THR - Transmit Holding Register
Read-only
Write-only
0
0 0
DLL - Divisor LSB
Read/Write
0
0 1
DLM - Divisor MSB
Read/Write
0
1 0
DLD - Divisor Fractional
Read/Write
0
0 1
IER - Interrupt Enable Register
Read/Write
0
1 0
ISR - Interrupt Status Register
FCR - FIFO Control Register
Read-only
Write-only
0
1 1
LCR - Line Control Register
Read/Write
1
0 0
MCR - Modem Control Register
Read/Write
1
0 1
LSR - Line Status Register
Read-only
1
1 0
MSR - Modem Status Register
Read-only
See Table 13
1
1 1
SPR - Scratch Pad Register
Read/Write
See Table 12
1
1 0
TCR - Transmission Control Register
Read/Write
See Table 13
1
1 1
TLR - Trigger Level Register
Read/Write
See Table 12
1
1 1
FIFO Rdy - FIFO Ready Register
Read-only
See Table 12
LCR[7] = 1, LCR ≠ 0xBF
LCR[7] = 1, LCR ≠ 0xBF,
EFR[4] = 1
LCR[7] = 0
LCR ≠ 0xBF
ENHANCED REGISTERS
0
1 0
EFR - Enhanced Function Register
Read/Write
1
0 0
Xon-1 - Xon Character 1
Read/Write
1
0 1
Xon-2 - Xon Character 2
Read/Write
1
1 0
Xoff-1 - Xoff Character 1
Read/Write
1
1 1
Xoff-2 - Xoff Character 2
Read/Write
22
LCR = 0xBF
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
.
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
REG
ADDRESS
NAME
A2-A0
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
16C550 Compatible Registers
000
RHR
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
THR
WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
IER
RD/WR
0/
0/
0/
0/
CTS Int.
Enable
RTS Int.
Enable
Xoff Int.
Enable
Sleep
Mode
Enable
0/
0/
INT
Source
Bit-5
INT
Source
Bit-4
0/
0/
010
010
ISR
FCR
RD
WR
FIFOs
FIFOs
Enabled Enabled
RX FIFO RX FIFO
Trigger
Trigger
TX FIFO TX FIFO
Trigger Trigger
011
LCR RD/WR
Divisor
Enable
Set TX
Break
Set Parity
100
MCR RD/WR
0/
0/
0/
Clock
Prescaler
Select
Even
Parity
Modem RX Line
Stat. Int. Stat. Int.
Enable Enable
TX
RX Data
Empty
Int.
Int
Enable
Enable
INT
Source
Bit-3
INT
Source
Bit-2
INT
Source
Bit-1
INT
Source
Bit-0
DMA TX FIFO
Mode
Reset
Enable
RX
FIFO
Reset
FIFOs
Enable
Parity
Enable
Word
Length
Bit-1
Word
Length
Bit-0
RTS#
Output
Control
DTR#
Output
Control
Stop
Bits
Internal OP2#/
FIFO
Lopback INT OutRdy
TCR and XonAny Enable
Enable
put
TLR
Enable (OP1#)
ENable
LCR[7]=0
LCR≠0xBF
101
LSR
RD
RX FIFO
Global
Error
THR &
TSR
Empty
THR
Empty
RX
Break
RX
Framing
Error
RX
Parity
Error
RX
Overrun
Error
RX Data
Ready
110
MSR
RD
CD#
Input
RI# Input
DSR#
Input
CTS#
Input
Delta
CD#
Delta
RI#
Delta
DSR#
Delta
CTS#
See Table 13
111
SPR RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
See Table 12
110
TCR RD/WR Resume Resume Resume Resume
Bit-3
Bit-2
Bit-1
Bit-0
Halt
Bit-3
Halt
Bit-2
Halt
Bit-1
Halt
Bit-0
See Table 13
111
TLR RD/WR RX Trig
Bit-3
TX Trig
Bit-3
TX Trig
Bit-2
TX Trig
Bit-1
111
FIFO
Rdy
0
0
RD
0
RX Trig
Bit-2
0
RX Trig
Bit-1
RX Trig
Bit-0
RX FIFO RX FIFO
B Status A Status
23
TX Trig
See Table 12
Bit-0
TX FIFO TX FIFO
See Table 12
B Status A Status
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
REG
ADDRESS
NAME
A2-A0
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
LCR[7]=1
LCR≠0xBF
Baud Rate Generator Divisor
000
DLL
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
DLM RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
010
DLD RD/WR IR Mode
Bit-3
Bit-2
Bit-1
Bit-0
Software
Flow
Cntl
Bit-2
Software
Flow
Cntl
Bit-1
Software
Flow
Cntl
Bit-0
DLD
Software
Flow
Cntl
Bit-3
Auto
4X Mode 8X Mode
RS485
Direction
Control
LCR[7]=1
LCR≠0xBF
EFR[4]=1
Enhanced Registers
010
EFR RD/WR
Auto Auto RTS
CTS
Enable
Enable
Special
Char
Select
Enable
IER [7:4],
ISR [5:4],
FCR[5:4],
MCR[7:5],
100
XON1 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
101
XON2 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
110
XOFF RD/WR
1
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
111
XOFF RD/WR
2
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
LCR=0XBF
4.0 INTERNAL REGISTER DESCRIPTIONS
4.1
Receive Holding Register (RHR) - Read- Only
SEE”RECEIVER” ON PAGE 15.
4.2
Transmit Holding Register (THR) - Write-Only
SEE”TRANSMITTER” ON PAGE 13.
4.3
Interrupt Enable Register (IER) - Read/Write
The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status
and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR).
4.3.1
IER versus Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts
(see ISR bits 2 and 3) status will reflect the following:
A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed
trigger level. It will be cleared when the FIFO drops below the programmed trigger level.
B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register
status bit and the interrupt will be cleared when the FIFO drops below the trigger level.
C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to
the receive FIFO. It is reset when the FIFO is empty.
24
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
4.3.2
IER versus Receive/Transmit FIFO Polled Mode Operation
When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16M752 in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can
be used in the polled mode by selecting respective transmit or receive control bit(s).
A. LSR BIT-0 indicates there is data in RHR or RX FIFO.
B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid.
C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any.
D. LSR BIT-5 indicates THR is empty.
E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty.
F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO.
IER[0]: RHR Interrupt Enable
The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when
the receive FIFO has reached the programmed trigger level in the FIFO mode.
• Logic 0 = Disable the receive data ready interrupt (default).
• Logic 1 = Enable the receiver data ready interrupt.
IER[1]: THR Interrupt Enable
This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when spaces in the FIFO is above the programmed trigger level in the FIFO mode. If the THR is
empty when this bit is enabled, an interrupt will be generated.
• Logic 0 = Disable Transmit Ready interrupt (default).
• Logic 1 = Enable Transmit Ready interrupt.
IER[2]: Receive Line Status Interrupt Enable
If any of the LSR register bits 1, 2, 3, 4 or 7 is a logic 1, it will generate an interrupt to inform the host controller
about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when the
character has been received. LSR bit-7 is set if any character in the RX FIFO has a parity or framing error, or is
a break character. LSR[4:2] always show the error status for the received character available for reading from
the RX FIFO. If IER[2] = 1, an LSR interrupt will be generated as long as LSR[7] = 1, ie. the RX FIFO contains
at lease one character with an error.
• Logic 0 = Disable the receiver line status interrupt (default).
• Logic 1 = Enable the receiver line status interrupt.
IER[3]: Modem Status Interrupt Enable
• Logic 0 = Disable the modem status register interrupt (default).
• Logic 1 = Enable the modem status register interrupt.
IER[4]: Sleep Mode Enable (requires EFR bit-4 = 1)
• Logic 0 = Disable Sleep Mode (default).
• Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details.
IER[5]: Xoff Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the software flow control, receive Xoff interrupt (default).
• Logic 1 = Enable the receive Xoff interrupt. See Software Flow Control section for details.
25
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
IER[6]: RTS# Output Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the RTS# interrupt (default).
• Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition
from low to high.
IER[7]: CTS# Input Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the CTS# interrupt (default).
• Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from
low to high.
4.4
Interrupt Status Register (ISR) - Read-Only
The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The
Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the
ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be
serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt
Source Table, Table 9, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources
associated with each of these interrupt levels.
4.4.1
Interrupt Generation:
• LSR is by any of the LSR bits 1, 2, 3, 4 and 7.
• RXRDY is by RX trigger level.
• RXRDY Time-out is by a 4-char plus 12 bits delay timer.
• TXRDY is by TX trigger level or TX FIFO empty (or transmitter empty in auto RS-485 control).
• MSR is by any of the MSR bits 0, 1, 2 and 3.
• Receive Xoff/Special character is by detection of a Xoff or Special character.
• CTS# is when its transmitter toggles the input pin (from LOW to HIGH) during auto CTS flow control.
• RTS# is when its receiver toggles the output pin (from LOW to HIGH) during auto RTS flow control.
4.4.2
Interrupt Clearing:
• LSR interrupt is cleared by reading all characters with errors out of the RX FIFO.
• RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level.
• RXRDY Time-out interrupt is cleared by reading RHR.
• TXRDY interrupt is cleared by a read to the ISR register or writing to THR.
• MSR interrupt is cleared by a read to the MSR register.
• Xoff interrupt is cleared when Xon character(s) is received.
• Special character interrupt is cleared by a read to ISR.
• RTS# and CTS# flow control interrupts are cleared by a read to the MSR register.
26
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
]
TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL
PRIORITY
ISR REGISTER STATUS BITS
SOURCE OF INTERRUPT
LEVEL
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
1
0
0
0
1
1
0
LSR (Receiver Line Status Register)
2
0
0
1
1
0
0
RXRDY (Receive Data Time-out)
3
0
0
0
1
0
0
RXRDY (Received Data Ready)
4
0
0
0
0
1
0
TXRDY (Transmit Ready)
5
0
0
0
0
0
0
MSR (Modem Status Register)
6
0
1
0
0
0
0
RXRDY (Received Xoff or Special character)
7
1
0
0
0
0
0
CTS#, RTS# change of state
-
0
0
0
0
0
1
None (default)
ISR[0]: Interrupt Status
• Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt
service routine.
• Logic 1 = No interrupt pending (default condition).
ISR[3:1]: Interrupt Status
These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 9).
ISR[4]: Xoff/Xon or Special Character Interrupt Status
This bit is set when EFR[4] = 1 and IER[5] = 1. ISR bit-4 indicates that the receiver detected a data match of
the Xoff character(s). If this is an Xoff interrupt, it is cleared when XON is received. If it is a special character
interrupt, it is cleared by reading ISR.
ISR[5]: RTS#/CTS# Interrupt Status
This bit is enabled when EFR[4] = 1. ISR bit-5 indicates that the CTS# or RTS# has been de-asserted.
ISR[7:6]: FIFO Enable Status
These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are
enabled.
4.5
FIFO Control Register (FCR) - Write-Only
This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and
select the DMA mode. The DMA, and FIFO modes are defined as follows:
FCR[0]: TX and RX FIFO Enable
• Logic 0 = Disable the transmit and receive FIFO (default).
• Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are
written or they will not be programmed.
27
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FCR[1]: RX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No receive FIFO reset (default)
• Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
FCR[2]: TX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No transmit FIFO reset (default).
• Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
FCR[3]: DMA Mode Select
Controls the behavior of the TXRDY# and RXRDY# pins. See DMA operation section for details.
• Logic 0 = Normal Operation (default).
• Logic 1 = DMA Mode.
FCR[5:4]: Transmit FIFO Trigger Select (requires EFR bit-4=1)
(logic 0 = default, TX trigger level = 1)
These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the
number of spaces in the FIFO is above the selected trigger level, or when it gets empty in case that the FIFO
did not get filled over the trigger level on last re-load. Table 10 shows the selections. The UART will issue a
transmit interrupt when the number of available spaces in the FIFO is less than the transmit trigger level.
Table 10 shows the selections.
FCR[7:6]: Receive FIFO Trigger Select
(logic 0 = default, RX trigger level =1)
These 2 bits are used to set the trigger level for the receive FIFO. The UART will issue a receive interrupt when
the number of the characters in the FIFO is greater than the receive trigger level or when a receive data
timeout occurs (see “Section 2.10, Receiver” on page 15).
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION
FCR
BIT-7
0
0
1
1
FCR
BIT-6
FCR
BIT-5
FCR
BIT-4
0
0
1
1
0
1
0
1
RECEIVE
TRIGGER LEVEL
(CHARACTERS)
TRANSMIT
TRIGGER LEVEL
(SPACES)
8
16
32
56
0
1
0
1
8
16
56
60
28
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
4.6
Line Control Register (LCR) - Read/Write
The Line Control Register is used to specify the asynchronous data communication format. The word or
character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this
register.
LCR[1:0]: TX and RX Word Length Select
These two bits specify the word length to be transmitted or received.
BIT-1
BIT-0
WORD LENGTH
0
0
5
0
1
6 (default)
1
0
7
1
1
8
LCR[2]: TX and RX Stop-bit Length Select
The length of stop bit is specified by this bit in conjunction with the programmed word length.
LENGTH
STOP BIT LENGTH
(BIT TIME(S))
0
5,6,7,8
1
1
5
1-1/2
1
6,7,8
2 (default)
BIT-2
WORD
LCR[3]: TX and RX Parity Select
Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data
integrity check. See Table 11 for parity selection summary below.
• Logic 0 = No parity.
• Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the
data character received.
LCR[4]: TX and RX Parity Select
If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR bit-4 selects the even or odd parity format.
• Logic 0 = ODD Parity is generated by forcing an odd number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format.
• Logic 1 = EVEN Parity is generated by forcing an even number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format.
29
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
LCR[5]: TX and RX Parity Select
If the parity bit is enabled, LCR BIT-5 selects the forced parity format.
• LCR BIT-5 = logic 0, parity is not forced (default).
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive
data.
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive
data.
TABLE 11: PARITY SELECTION
LCR BIT-5 LCR BIT-4 LCR BIT-3
PARITY SELECTION
X
X
0
No parity
0
0
1
Odd parity
0
1
1
Even parity
1
0
1
Force parity to mark, “1”
1
1
1
Forced parity to space, “0”
LCR[6]: Transmit Break Enable
When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a
“space", LOW state). This condition remains, until disabled by setting LCR bit-6 to a logic 0.
• Logic 0 = No TX break condition (default).
• Logic 1 = Forces the transmitter output (TX) to a “space”, LOW, for alerting the remote receiver of a line
break condition.
LCR[7]: Baud Rate Divisors Enable
Baud rate generator divisor (DLL, DLM and DLD) enable.
• Logic 0 = Data registers are selected (default).
• Logic 1 = Divisor latch registers are selected.
4.7
Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write
The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs.
MCR[0]: DTR# Output
The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a
general purpose output.
• Logic 0 = Force DTR# output HIGH (default).
• Logic 1 = Force DTR# output LOW.
MCR[1]: RTS# Output
The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by
EFR bit-6. The RTS# pin can also be used for Auto RS485 Half-Duplex direction control enabled by FCTR bit3. If the modem interface is not used, this output may be used as a general purpose output.
• Logic 0 = Force RTS# HIGH (default).
• Logic 1 = Force RTS# LOW.
30
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
MCR[2]: OP1# / FIFO Rdy Enable
OP1# is not available as an output pin on the M752. But it is available for use during Internal Loopback Mode
(MCR[4] = 1). In the Internal Loopback Mode, this bit is used to write the state of the modem RI# interface
signal.
This bit is also used to select between the SPR, TLR and FIFO Rdy registers. All of these registers are
accessible at address offset 0x7 when LCR≠0xBF. However, LCR = 0xBF is required to access EFR.
TABLE 12: REGISTER AT ADDRESS OFFSET 0X7
EFR[4] MCR[6] MCR[4, 2] Register at Address Offset 0x7
0
X
≠’01’
Scratchpad Register (SPR)
1
0
≠’01’
Scratchpad Register (SPR)
1
1
≠’01’
Trigger Level Register (TLR)
X
X
=’01’
FIFO Ready Register (FIFO Rdy)
MCR[3]: OP2# Output / INT Output Enable
This bit enables or disables the operation of INT, interrupt output. If INT output is not used, OP2# can be used
as a general purpose output.
• Logic 0 = INT (A-B) outputs disabled (three state mode) and OP2# output set HIGH(default).
• Logic 1 = INT (A-B) outputs enabled (active mode) and OP2# output set LOW.
MCR[4]: Internal Loopback Enable
• Logic 0 = Disable loopback mode (default).
• Logic 1 = Enable local loopback mode, see loopback section and Figure 12.
MCR[5]: Xon-Any Enable (requires EFR bit-4=1 to write to this bit)
• Logic 0 = Disable Xon-Any function (default).
• Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
the M752 is programmed to use the Xon/Xoff flow control.
MCR[6]: TCR and TLR Enable (requires EFR bit-4=1 to write to this bit)
This bit enables the TCR and TLR registers at address offset 0x6 and 0x7, respectively. See Table 12 above
for the correct register setting to access the TLR register. See Table 13 below for the setting to access the
TCR register.
• Logic 0 = Reserved (default).
• Logic 1 = Enable access to the TCR and TLR registers.
TABLE 13: REGISTER AT ADDRESS OFFSET 0X6
EFR[4] MCR[6] Register at Address Offset 0x6
0
X
Modem Status Register (MSR)
1
0
Modem Status Register (MSR)
1
1
Trigger Control Register (TCR)
31
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
MCR[7]: Clock Prescaler Select (requires EFR bit-4=1 to write to this bit)
• Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
• Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
4.8
Line Status Register (LSR) - Read Only
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
• Logic 0 = No data in receive holding register or FIFO (default).
• Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Error Flag
• Logic 0 = No overrun error (default).
• Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Tag
• Logic 0 = No parity error (default).
• Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Tag
• Logic 0 = No framing error (default).
• Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Error Tag
• Logic 0 = No break condition (default).
• Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO.
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and
transmit shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
• Logic 0 = No FIFO error (default).
32
XR16M752/XR68M752
REV. 1.0.2
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
• Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
RX FIFO.
4.9
Modem Status Register (MSR) - Read Only
This register provides the current state of the modem interface input signals. Lower four bits of this register are
used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem
changes state. These bits may be used for general purpose inputs when they are not used with modem
signals.
MSR[0]: Delta CTS# Input Flag
• Logic 0 = No change on CTS# input (default).
• Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[1]: Delta DSR# Input Flag
• Logic 0 = No change on DSR# input (default).
• Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[2]: Delta RI# Input Flag
• Logic 0 = No change on RI# input (default).
• Logic 1 = The RI# input has changed from a LOW to HIGH, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[3]: Delta CD# Input Flag
• Logic 0 = No change on CD# input (default).
• Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[4]: CTS Input Status
CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto
CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the
modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has
finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of
the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The
CTS# input may be used as a general purpose input when the modem interface is not used.
MSR[5]: DSR Input Status
Normally this bit is the complement of the DSR# input. In the loopback mode, this bit is equivalent to the DTR#
bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is
not used.
MSR[6]: RI Input Status
Normally this bit is the complement of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the
MCR register. The RI# input may be used as a general purpose input when the modem interface is not used.
MSR[7]: CD Input Status
Normally this bit is the complement of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the
MCR register. The CD# input may be used as a general purpose input when the modem interface is not used.
33
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
4.10
REV. 1.0.2
Scratch Pad Register (SPR) - Read/Write
This is a 8-bit general purpose register for the user to store temporary data. The content of this register is
preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle. There are also
two other registers (TLR and FIFO Rdy) that share the same address location as the Scratch Pad Register.
See Table 12.
4.11
Transmission Control Register (TCR) - Read/Write (requires EFR bit-4 = 1)
This register replaces MSR and is accessible only when MCR[6] = 1. This 8-bit register is used to store the RX
FIFO threshold levels to halt/resume transmission during hardware or software flow control.
TCR[3:0]: RX FIFO Halt Level
A value of 0-60 (decimal value of TCR[3:0] multiplied by 4) can be selected as the Halt Level. When the RX
FIFO is greater than or equal to this value, the RTS# output will be de-asserted if Auto RTS flow control is used
or the XOFF character(s) will be transmitted if Auto XON/XOFF flow control is used. It is recommended that
this value is greater than the RX Trigger Level.
TCR[7:4]: RX FIFO Resume Level
A value of 0-60 (decimal value of TCR[7:4] multiplied by 4) can be selected as the Resume Level. When the
RX FIFO is less than or equal to this value, the RTS# output will be re-asserted if Auto RTS flow control is used
or the XON character(s) will be transmitted if Auto XON/XOFF flow control is used. It is recommended that this
value is less than the RX Trigger Level.
4.12
Trigger Level Register (TLR) - Read/Write (requires EFR bit-4 = 1)
This register replaces SPR and is accessible under the conditions listed in Table 12. This 8-bit register is used
to store the RX and TX FIFO trigger levels used for interrupts.
TLR[3:0]: TX FIFO Trigger Level
A value of 4-60 (decimal value of TCR[3:0] multiplied by 4) can be selected as the TX FIFO Trigger Level.
When the number of available spaces in the TX FIFO is greater than or equal to this value, a Transmit Ready
interrupt is generated. For any non-zero value, TCR[3:0] will be used as the TX FIFO Trigger Level. If
TCR[3:0] = 0x0, then the TX FIFO Trigger Level is the value selected by FCR[5:4]. See Table 10.
TLR[7:4]: RX FIFO Trigger Level
A value of 4-60 (decimal value of TCR[7:4] multiplied by 4) can be selected as the RX FIFO Trigger Level.
When the number of characters received in the RX FIFO is greater than or equal to this value, a Receive Data
Ready interrupt is generated (a Receive Data Timeout interrupt is independent of the RX FIFO Trigger Level
and can be generated any time there is at least 1 byte in the RX FIFO and the RX input has been idle for the
timeout period described in “Section 2.10, Receiver” on page 15). For any non-zero value, TCR[7:4] will be
used as the RX FIFO Trigger Level. If TCR[7:4] = 0x0, then the RX FIFO Trigger Level is the value selected by
FCR[7:6]. See Table 10.
4.13
Baud Rate Generator Registers (DLL, DLM and DLD[3:0]) - Read/Write
These registers make-up the value of the baud rate divisor. The concatenation of the contents of DLM and
DLL is a 16-bit value is then added to DLD[3:0]/16 to achieve the fractional baud rate divisor. DLD must be
enabled via EFR bit-4 before it can be accessed. SEE”PROGRAMMABLE BAUD RATE GENERATOR WITH
FRACTIONAL DIVISOR” ON PAGE 11.
DLD[5:4]: Sampling Rate Select
These bits select the data sampling rate. By default, the data sampling rate is 16X. The maximum data rate will
double if the 8X mode is selected and will quadruple if the 4X mode is selected. See Table 14 below.
34
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE 14: SAMPLING RATE SELECT
DLD[5]
DLD[4]
SAMPLING RATE
0
0
16X
0
1
8X
1
X
4X
DLD[6]: Auto RS-485 Direction Control
• Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
becomes empty and transmit shift register is shifting data out. The RTS# output can be used as a general
purpose output or for Auto RTS flow control.
• Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its
output logic state from HIGH to LOW one bit time after the last stop bit of the last character is shifted out.
Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The
RTS# output pin will automatically return to a HIGH when a data byte is loaded into the TX FIFO. See
“Section 2.13, Auto RS485 Half-duplex Control” on page 16.
DLD[7]: Infrared Encoder/Decoder Enable
• Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
• Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be idling LOW. SEE”INFRARED MODE” ON
PAGE 18.
4.14
Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive
character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes
are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that
whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before
programming a new setting.
EFR[3:0]: Software Flow Control Select
Single character and dual sequential characters software flow control is supported. Combinations of software
flow control can be selected by programming these bits.
TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS
EFR BIT-3
CONT-3
EFR BIT-2
CONT-2
EFR BIT-1
CONT-1
EFR BIT-0
CONT-0
0
0
0
0
No TX and RX flow control (default and reset)
0
0
X
X
No transmit flow control
1
0
X
X
Transmit Xon1, Xoff1
0
1
X
X
Transmit Xon2, Xoff2
1
1
X
X
Transmit Xon1 and Xon2, Xoff1 and Xoff2
X
X
0
0
No receive flow control
X
X
1
0
Receiver compares Xon1, Xoff1
35
TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS
EFR BIT-3
CONT-3
EFR BIT-2
CONT-2
EFR BIT-1
CONT-1
EFR BIT-0
CONT-0
X
X
0
1
Receiver compares Xon2, Xoff2
1
0
1
1
Transmit Xon1, Xoff1
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
0
1
1
1
Transmit Xon2, Xoff2
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
1
1
1
1
Transmit Xon1 and Xon2, Xoff1 and Xoff2,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
0
0
1
1
No transmit flow control,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL
EFR[4]: Enhanced Function Bits Enable
Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 5-7, TCR,
TLR and DLD to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the
new values. This feature prevents legacy software from altering or overwriting the enhanced functions once
set. Normally, it is recommended to leave it enabled, logic 1.
• Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 57, and DLD are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5,
MCR bits 5-7, and DLD are set to a logic 0 to be compatible with ST16C550 mode (default).
• Logic 1 = Enables the above-mentioned register bits to be modified by the user.
EFR[5]: Special Character Detect Enable
• Logic 0 = Special Character Detect Disabled (default).
• Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts HIGH at the programmed HALT level. RTS# will return LOW when FIFO data falls below the
programmed RESUME level. The RTS# output must be asserted (LOW) before the auto RTS can take effect.
RTS# pin will function as a general purpose output when hardware flow control is disabled.
• Logic 0 = Automatic RTS flow control is disabled (default).
• Logic 1 = Enable Automatic RTS flow control.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
• Logic 0 = Automatic CTS flow control is disabled (default).
36
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
• Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts HIGH.
Data transmission resumes when CTS# returns LOW.
4.14.1
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see Table 8.
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B
REGISTERS
RESET STATE
DLM, DLL
DLM = 0x00 and DLL = 0x01. Only resets to these values during a power up.
They do not reset when the Reset Pin is asserted.
DLD
Bits 7-0 = 0x00
RHR
Bits 7-0 = 0xXX
THR
Bits 7-0 = 0xXX
IER
Bits 7-0 = 0x00
FCR
Bits 7-0 = 0x00
ISR
Bits 7-0 = 0x01
LCR
Bits 7-0 = 0x1D
MCR
Bits 7-0 = 0x00
LSR
Bits 7-0 = 0x60
MSR
Bits 3-0 = Logic 0
Bits 7-4 = Logic levels of the inputs inverted
SPR
Bits 7-0 = 0xFF. Only resets to these values during a power up. They do not
reset when the Reset Pin is asserted.
TCR
Bits 7-0 = 0x0F
TLR
Bits 7-0 = 0x00
FIFO Rdy
Bits 7-0 = 0x03
EFR
Bits 7-0 = 0x00
XON1
Bits 7-0 = 0x00. Only resets to these values during a power up. They do not
reset when the Reset Pin is asserted.
XON2
Bits 7-0 = 0x00. Only resets to these values during a power up. They do not
reset when the Reset Pin is asserted.
XOFF1
Bits 7-0 = 0x00. Only resets to these values during a power up. They do not
reset when the Reset Pin is asserted.
XOFF2
Bits 7-0 = 0x00. Only resets to these values during a power up. They do not
reset when the Reset Pin is asserted.
37
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B
REGISTERS
RESET STATE
I/O SIGNALS
RESET STATE
TX
HIGH
OP2#
HIGH
RTS#
HIGH
DTR#
HIGH
RXRDY#
HIGH
TXRDY#
LOW
INT
Three-State Condition
5.0 ELECTRICAL CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
Power Supply Range
4 Volts
Voltage at Any Pin
GND-0.3V to 4V
Operating Temperature
-40o to +85oC
Storage Temperature
-65o to +150oC
Package Dissipation
500 mW
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%)
Thermal Resistance (48-TQFP)
theta-ja =59oC/W, theta-jc = 16oC/W
Thermal Resistance (32-QFN)
theta-ja = 33oC/W, theta-jc = 22oC/W
DC ELECTRICAL CHARACTERISTICS
TA= -40o to +85oC, Vcc is 1.62V to 3.63V
SYMBOL
PARAMETER
LIMITS
1.8V
MIN
MAX
LIMITS
2.5V
MIN
MAX
LIMITS
3.3V
MIN
MAX
UNITS
VILCK
Clock Input Low Level
-0.3
0.3
-0.3
0.6
-0.3
0.6
V
VIHCK
Clock Input High Level
1.4
VCC
1.8
VCC
2.4
VCC
V
VIL
Input Low Voltage
-0.3
0.2
-0.3
0.5
-0.3
0.8
V
VIH
Input High Voltage
1.4
VCC
1.8
VCC
2.0
VCC
V
VOL
Output Low Voltage
0.4
V
V
0.4
0.4
CONDITIONS
IOL = 4 mA
IOL = 2 mA
IOL = 1.5 mA
38
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
DC ELECTRICAL CHARACTERISTICS
TA= -40o to +85oC, Vcc is 1.62V to 3.63V
SYMBOL
VOH
LIMITS
1.8V
MAX
MIN
PARAMETER
LIMITS
2.5V
MAX
MIN
Output High Voltage
LIMITS
3.3V
MAX
MIN
2.0
UNITS
V
V
1.8
CONDITIONS
IOH = -1 mA
IOH = -400 uA
1.4
IOH = -200 uA
IIL
Input Low Leakage Current
±10
±10
±10
uA
IIH
Input High Leakage Current
±10
±10
±10
uA
CIN
Input Pin Capacitance
5
5
5
pF
ICC
Power Supply Current
0.5
1
2
mA
XTAL1 = 2 MHz
ISLEEP
Sleep Current (16 Mode)
3
10
15
uA
See Test 1
ISLEEP
Sleep Current (68 Mode)
50
75
100
uA
See Test 1
Test 1: The following inputs must remain steady at VCC or GND state to minimize Sleep current: A0-A2, D0D7, IOR#, IOW#, CSA# (CS# in 68 Mode), CSB# and all modem inputs. Also, RXA and RXB inputs must idle
HIGH while asleep. Floating inputs will result in sleep currents in the mA range.
AC ELECTRICAL CHARACTERISTICS
Unless otherwise noted: TA=-40o to +85oC, Vcc=1.62 - 3.63V, 70 pF load where applicable
SYMBOL
LIMITS
LIMITS
LIMITS
1.8V ± 10%
2.5V ± 10%
3.3V ± 10%
MIN
MAX MIN
MAX MIN
MAX
PARAMETER
UNIT
XTAL1
UART Crystal Oscillator
24
24
24
MHz
ECLK
External Clock
32
50
64
MHz
TECLK
External Clock Time Period
15
10
7
ns
TAS
Address Setup Time (16 mode)
5
5
5
ns
TAH
Address Hold Time (16 mode)
0
0
0
ns
TCS
Chip Select Width (16 mode)
60
30
30
ns
TRD
IOR# Strobe Width (16 mode)
60
30
30
ns
TDY
Read Cycle Delay (16 mode)
60
30
30
ns
TRDV
Data Access Time (16 mode)
TDD
Data Disable Time (16 mode)
0
TWR
IOW# Strobe Width (16 mode)
60
30
30
ns
TDY
Write Cycle Delay (16 mode)
60
30
30
ns
TDS
Data Setup Time (16 mode)
15
10
10
ns
55
39
20
25
0
20
0
25
ns
10
ns
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
AC ELECTRICAL CHARACTERISTICS
Unless otherwise noted: TA=-40o to +85oC, Vcc=1.62 - 3.63V, 70 pF load where applicable
SYMBOL
LIMITS
LIMITS
LIMITS
1.8V ± 10%
2.5V ± 10%
3.3V ± 10%
MIN
MAX MIN
MAX MIN
MAX
PARAMETER
UNIT
TDH
Data Hold Time (16 mode)
5
5
5
ns
TADS
Address Setup (68 Mode)
5
5
5
ns
TADH
Address Hold (68 Mode)
0
0
0
ns
TRWS
R/W# Setup to CS# (68 Mode)
5
5
5
ns
TRDA
Read Data Access (68 mode)
55
25
25
ns
TRDH
Read Data Disable (68 mode)
20
20
10
ns
TWDS
Write Data Setup (68 mode)
15
10
10
ns
TWDH
Write Data Hold (68 Mode)
5
5
5
ns
TRWH
CS# De-asserted to R/W# De-asserted (68
Mode)
5
5
5
ns
TCSL
CS# Width (68 Mode)
60
30
30
ns
TCSD
CS# Cycle Delay (68 Mode)
60
30
30
ns
TWDO
Delay From IOW# To Output
50
50
50
ns
TMOD
Delay To Set Interrupt From MODEM Input
50
50
50
ns
TRSI
Delay To Reset Interrupt From IOR#
50
50
50
ns
TSSI
Delay From Stop To Set Interrupt
1
1
1
Bclk
TRRI
Delay From IOR# To Reset Interrupt
45
45
45
ns
TSI
Delay From Stop To Interrupt
45
45
45
ns
TINT
Delay From Initial INT Reset To Transmit Start
24
Bclk
TWRI
Delay From IOW# To Reset Interrupt
45
45
45
ns
TSSR
Delay From Stop To Set RXRDY#
1
1
1
Bclk
TRR
Delay From IOR# To Reset RXRDY#
45
45
45
ns
TWT
Delay From IOW# To Set TXRDY#
45
45
45
ns
TSRT
Delay From Center of Start To Reset TXRDY#
8
8
8
Bclk
TRST
Reset Pulse Width
Bclk
Baud Clock
8
40
40
24
8
40
24
8
40
ns
16X or 8X or 4X of data rate
Hz
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 13. CLOCK TIMING
TECLK
TECL
TECH
VIH
External
Clock
VIL
FIGURE 14. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B
IOW #
Active
T W DO
RTS#
DTR#
Change of state
Change of state
CD#
CTS#
DSR#
Change of state
Change of state
T MO D
T M OD
INT
Active
Active
Active
T RSI
IOR#
Active
Active
Active
T M OD
Change of state
RI#
41
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 15. 16 MODE (INTEL) DATA BUS READ TIMING
A0-A2
Valid Address
TAS
TCS
Valid Address
TAS
TAH
TAH
TCS
CSA#/
CSB#
TDY
TRD
TRD
IOR#
TDD
TRDV
D0-D7
TDD
TRDV
Valid Data
Valid Data
RDTm
FIGURE 16. 16 MODE (INTEL) DATA BUS WRITE TIMING
A0-A2
Valid Address
TAS
TCS
Valid Address
TAS
TAH
TCS
TAH
CSA#/
CSB#
TDY
TWR
TWR
IOW#
TDS
D0-D7
TDH
Valid Data
TDS
TDH
Valid Data
16Write
42
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 17. 68 MODE (MOTOROLA) DATA BUS READ TIMING
A0-A2
Valid Address
TADS
TCSL
Valid Address
TADH
CS#
TCSD
TRWS
TRWH
R/W#
TRDH
TRDA
D0-D7
Valid Data
Valid Data
68Read
FIGURE 18. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING
A0-A2
Valid Address
TADS
TCSL
Valid Address
TADH
CS#
TCSD
TRWS
TRWH
R/W#
TWDS
D0-D7
T WDH
Valid Data
Valid Data
68Write
43
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 19. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
RX
Start
Bit
Stop
Bit
D0:D7
INT
D0:D7
D0:D7
TSSR
TSSR
TSSR
1 Byte
in RHR
1 Byte
in RHR
1 Byte
in RHR
TSSR
TSSR
Active
Data
Ready
Active
Data
Ready
RXRDY#
TRR
TSSR
Active
Data
Ready
TRR
TRR
IOR#
(Reading data
out of RHR)
RXNFM
FIGURE 20. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
TX
Start
Bit
IER[1]
enabled
Stop
Bit
D0:D7
D0:D7
ISR is read
D0:D7
ISR is read
ISR is read
INT*
TWRI
TWRI
TWRI
TSRT
TSRT
TSRT
TXRDY#
TWT
TWT
TWT
IOW#
(Loading data
into THR)
*INT is cleared when the ISR is read or when data is loaded into the THR.
44
TXNonFIFO
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B
Start
Bit
RX
S D0:D7
S D0:D7 T
D0:D7
Stop
Bit
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
FIFO
Empties
TSSR
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
RXRDY#
First Byte is
Received in
RX FIFO
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXINTDMA#
FIGURE 22. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B
Start
Bit
RX
Stop
Bit
S D0:D7
S D0:D7 T
D0:D7
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
FIFO
Empties
TSSR
RXRDY#
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXFIFODMA
45
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B
Start
Bit
TX FIFO
Empty
TX
Stop
Bit
S D0:D7 T
(Unloading)
IER[1]
enabled
Last Data Byte
Transmitted
T S D0:D7 T S D0:D7 T
S D0:D7 T S D0:D7 T
ISR is read
TSI
ISR is read
S D0:D7 T
TSRT
INT*
TX FIFO
Empty
TX FIFO fills up
to trigger level
Data in
TX FIFO
TXRDY#
TX FIFO drops
below trigger level
TWRI
TWT
IOW#
(Loading data
into FIFO)
*INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level.
TXDMA#
FIGURE 24. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B
Start
Bit
TX
Stop
Bit
Last Data Byte
Transmitted
S D0:D7 T S D0:D7 T
(Unloading)
IER[1]
enabled
D0:D7
S D0:D7 T
ISR Read
S D0:D7 T S D0:D7 T
S D0:D7 T
TSI
TSRT
ISR Read
INT*
TX FIFO fills up
to trigger level
TXRDY#
TX FIFO drops
below trigger level
TWRI
At least 1
empty location
in FIFO
TX FIFO
Full
TWT
IOW#
(Loading data
into FIFO)
*INT cleared when the ISR is read or when TX FIFO fills up to trigger level.
46
TXDMA
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm)
D
D1
36
25
37
24
D1
48
13
1
2
1
B
e
A2
C
A
Seating
Plane
α
A1
L
Note: The control dimension is the millimeter column
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.039
0.047
1.00
1.20
A1
0.002
0.006
0.05
0.15
A2
0.037
0.041
0.95
1.05
B
0.007
0.011
0.17
0.27
C
0.004
0.008
0.09
0.20
D
0.346
0.362
8.80
9.20
D1
0.272
0.280
6.90
7.10
e
0.020 BSC
0.50 BSC
L
0.018
0.030
0.45
0.75
a
0°
7°
0°
7°
47
D
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
PACKAGE DIMENSIONS (32 PIN QFN - 5 X 5 X 0.9 mm)
Note: the actual center pad
is metallic and the size (D2)
is device-dependent with a
typical tolerance of 0.3mm
Note: The control dimension is in millimeter.
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.031
0.039
0.80
1.00
A1
0.000
0.002
0.00
0.05
A3
0.006
0.010
0.15
0.25
D
0.193
0.201
4.90
5.10
D2
0.138
0.150
3.50
3.80
b
0.007
0.012
0.18
0.30
e
0.0197 BSC
0.50 BSC
L
0.012
0.020
0.35
0.45
k
0.008
-
0.20
-
48
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
REVISION HISTORY
DATE
REVISION
DESCRIPTION
July 2006
P1.0.0
September 2006
1.0.0
Final Datasheet. Updated AC Electrical Characteristics.
May 2007
1.0.1
Corrected pin names pin out assignment for 48-pin TQFP package for XR68M752 in
Motorola mode. Added GND center pad for QFN package to pin description. Added
Motorola mode Read/Write timing waveforms. Updated QFN package dimensions
drawing to show minimum "k" parameter.
May 2007
1.0.2
Updated pin description table, correct pin # of RXA in QFN-32 package.
Preliminary Datasheet.
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any
circuits described herein, conveys no license under any patent or other right, and makes no representation that
the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration
purposes and may vary depending upon a user’s specific application. While the information in this publication
has been carefully checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the
failure or malfunction of the product can reasonably be expected to cause failure of the life support system or
to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless
EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has
been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately
protected under the circumstances.
Copyright 2007 EXAR Corporation
Datasheet May 2007.
Send your UART technical inquiry with technical details to hotline: [email protected].
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
49
XR16M752/XR68M752
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
REV. 1.0.2
TABLE OF CONTENTS
GENERAL DESCRIPTION ................................................................................................ 1
APPLICATIONS ............................................................................................................................................... 1
FEATURES .................................................................................................................................................... 1
FIGURE 1. XR16M752 BLOCK DIAGRAM .......................................................................................................................................... 1
FIGURE 2. PIN OUT ASSIGNMENT ..................................................................................................................................................... 2
ORDERING INFORMATION................................................................................................................................ 3
PIN DESCRIPTIONS ........................................................................................................ 3
1.0 PRODUCT DESCRIPTION....................................................................................................................... 7
2.0 FUNCTIONAL DESCRIPTIONS............................................................................................................... 8
2.1 CPU INTERFACE................................................................................................................................................. 8
FIGURE 3. XR16M752/XR68M752 DATA BUS INTERCONNECTIONS .................................................................................................. 8
2.2 DEVICE RESET ................................................................................................................................................... 9
2.3 CHANNEL A AND B SELECTION....................................................................................................................... 9
TABLE 1: CHANNEL A AND B SELECT IN 16 MODE ............................................................................................................................ 9
TABLE 2: CHANNEL A AND B SELECT IN 68 MODE ............................................................................................................................ 9
2.4 CHANNEL A AND B INTERNAL REGISTERS ................................................................................................... 9
2.5 DMA MODE........................................................................................................................................................ 10
TABLE 3: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE ........................................................................................... 10
2.6 INTA AND INTB OUTPUTS ............................................................................................................................... 10
TABLE 4: INTA AND INTB PINS OPERATION FOR TRANSMITTER ...................................................................................................... 10
TABLE 5: INTA AND INTB PIN OPERATION FOR RECEIVER ............................................................................................................. 10
2.7 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT .............................................................................. 11
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS ............................................................................................................................... 11
2.8 PROGRAMMABLE BAUD RATE GENERATOR WITH FRACTIONAL DIVISOR............................................ 11
FIGURE 5. BAUD RATE GENERATOR ............................................................................................................................................... 12
TABLE 6: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING ................................................... 13
2.9 TRANSMITTER .................................................................................................................................................. 13
2.9.1 TRANSMIT HOLDING REGISTER (THR) - WRITE ONLY ...........................................................................................
2.9.2 TRANSMITTER OPERATION IN NON-FIFO MODE ....................................................................................................
FIGURE 6. TRANSMITTER OPERATION IN NON-FIFO MODE ..............................................................................................................
2.9.3 TRANSMITTER OPERATION IN FIFO MODE .............................................................................................................
FIGURE 7. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE .....................................................................................
14
14
14
14
14
2.10 RECEIVER ....................................................................................................................................................... 15
2.10.1 RECEIVE HOLDING REGISTER (RHR) - READ-ONLY ............................................................................................ 15
FIGURE 8. RECEIVER OPERATION IN NON-FIFO MODE .................................................................................................................... 15
FIGURE 9. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE ......................................................................... 16
2.11 AUTO RTS (HARDWARE) FLOW CONTROL ................................................................................................
2.12 AUTO RTS HALT AND RESUME...................................................................................................................
2.13 AUTO RS485 HALF-DUPLEX CONTROL .....................................................................................................
2.14 AUTO CTS FLOW CONTROL ........................................................................................................................
16
16
16
17
FIGURE 10. AUTO RTS AND CTS FLOW CONTROL OPERATION ....................................................................................................... 17
2.15 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL...................................................................................... 18
2.16 SPECIAL CHARACTER DETECT .................................................................................................................. 18
2.17 INFRARED MODE ........................................................................................................................................... 18
FIGURE 11. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING .......................................................................... 19
2.18 SLEEP MODE WITH AUTO WAKE-UP.......................................................................................................... 19
2.19 INTERNAL LOOPBACK ................................................................................................................................. 20
FIGURE 12. INTERNAL LOOP BACK IN CHANNEL A AND B ................................................................................................................ 21
3.0 UART INTERNAL REGISTERS ............................................................................................................. 22
TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS ....................................................................................... 22
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ......................................... 23
4.0 INTERNAL REGISTER DESCRIPTIONS............................................................................................... 24
4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY .................................................................................. 24
4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ............................................................................... 24
4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE................................................................................. 24
4.3.1 IER VERSUS RECEIVE FIFO INTERRUPT MODE OPERATION ............................................................................... 24
4.3.2 IER VERSUS RECEIVE/TRANSMIT FIFO POLLED MODE OPERATION .................................................................. 25
4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY .................................................................................. 26
4.4.1 INTERRUPT GENERATION: ........................................................................................................................................ 26
I
XR16M752/XR68M752
REV. 1.0.2
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
4.4.2 INTERRUPT CLEARING: ............................................................................................................................................. 26
TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL ....................................................................................................................... 27
4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY ........................................................................................ 27
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION ............................................................................................ 28
4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE ........................................................................................ 29
TABLE 11: PARITY SELECTION ........................................................................................................................................................ 30
4.7 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE . 30
TABLE 12: REGISTER AT ADDRESS OFFSET 0X7 ............................................................................................................................. 31
TABLE 13: REGISTER AT ADDRESS OFFSET 0X6 ............................................................................................................................. 31
4.8 LINE STATUS REGISTER (LSR) - READ ONLY..............................................................................................
4.9 MODEM STATUS REGISTER (MSR) - READ ONLY .......................................................................................
4.10 SCRATCH PAD REGISTER (SPR) - READ/WRITE .......................................................................................
4.11 TRANSMISSION CONTROL REGISTER (TCR) - READ/WRITE (REQUIRES EFR BIT-4 = 1) ....................
4.12 TRIGGER LEVEL REGISTER (TLR) - READ/WRITE (REQUIRES EFR BIT-4 = 1) ......................................
4.13 BAUD RATE GENERATOR REGISTERS (DLL, DLM AND DLD[3:0]) - READ/WRITE................................
32
33
34
34
34
34
TABLE 14: SAMPLING RATE SELECT ............................................................................................................................................... 35
4.14 ENHANCED FEATURE REGISTER (EFR) ..................................................................................................... 35
TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS ........................................................................................................................ 35
4.14.1 SOFTWARE FLOW CONTROL REGISTERS (XOFF1, XOFF2, XON1, XON2) - READ/WRITE .............................. 37
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B ............................................................................................ 37
5.0 ELECTRICAL CHARACTERISTICS .....................................................................................................
ABSOLUTE MAXIMUM RATINGS ....................................................................................................................
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%)..............................................
DC ELECTRICAL CHARACTERISTICS.............................................................................................................
AC ELECTRICAL CHARACTERISTICS .............................................................................................................
38
38
38
38
39
FIGURE 13. CLOCK TIMING............................................................................................................................................................. 41
FIGURE 14. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B ................................................................................................. 41
FIGURE 16. 16 MODE (INTEL) DATA BUS WRITE TIMING ................................................................................................................. 42
FIGURE 15. 16 MODE (INTEL) DATA BUS READ TIMING ................................................................................................................... 42
FIGURE 17. 68 MODE (MOTOROLA) DATA BUS READ TIMING .......................................................................................................... 43
FIGURE 18. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING ......................................................................................................... 43
FIGURE 19. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ......................................................... 44
FIGURE 20. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ....................................................... 44
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B........................................ 45
FIGURE 22. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B......................................... 45
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B ........................... 46
FIGURE 24. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B ............................ 46
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm) .................................................................................. 47
PACKAGE DIMENSIONS (32 PIN QFN - 5 X 5 X 0.9 mm) ............................................................................... 48
REVISION HISTORY ..................................................................................................................................... 49
TABLE OF CONTENTS ..................................................................................................... I
II