36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Features Sub-harmonic, Image Reject Transmitter Integrated Mixer, LO Doubler/Buffer & Output Amplifier +17.0 dBm Output Third Order Intercept (OIP3) +2.0 dBm LO Drive Level 5.0 dB Conversion Gain 7x7mm SMT Package 100% RF and DC Testing General Description Absolute Maximum Ratings Mimix Broadband’s 36.0-42.0 GHz GaAs transmitter has a +17.0 dBm output third order intercept across the band. This device is a balanced, resistive pHEMT mixer followed by a distributed output amplifier and includes an integrated LO doubler and LO buffer amplifier. The use of integrated LO doubler and LO buffer amplifier makes the provision of the LO easier than for fundamental mixers at these frequencies. I and Q mixer inputs are provided and an external 90 degree hybrid is required to select the desired sideband. The device comes in a 7x7mm SMT package that is RoHS compliant.This device is well suited for Millimeter-wave Point-to-Point Radio, LMDS, SATCOM and VSAT applications. Supply Voltage (Vd) Supply Current (Id) Gate Bias Voltage (Vg) Input Power (Pin) Storage Temperature (Tstg) Operating Temperature (Ta) Channel Temperature (Tch) ESD - Human Body Model ESD - Machine Body Model +6.0 VDC 350 mA +0.3 VDC +0.0 dBm -65 to +165 deg C -55 to MTTF Table1 MTTF Table1 Class 1A Class M1 (1) Channel temperature affects a device’s MTTF. It is recommended to keep channel temperature as low as possible for maximum life Electrical Characteristics (Ambient Temperature T = 25o C) Parameter Frequency Range (RF) Upper Side Band Frequency Range (RF) Lower Side Band Frequency Range (LO) Frequency Range (IF) Output Return Loss RF (S22) Small Signal Conversion Gain IF/RF (S21) LO Input Drive (PLO) Leakage @ RF Port LOx1 Leakage @ RF Port LOx2 Input Third Order Intercept (IIP3) Attenuation Range Drain Bias Voltage (Vd) Gate Bias Voltage (Vg1) Gate Bias Voltage (Vg2) Mixer, Doubler Dynamic Range Control (Vc) Supply Current (Id) (Vd=4.0V) Supply Current (Ic) Units GHz GHz GHz GHz dB dB dBm dBm dBm dBm dB VDC VDC VDC VDC mA mA Min. 36.0 36.0 16.0 DC 2.0 +2.0 10.0 25.0 -2.0 - Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Typ. 10.0 5.0 +4.0 -25.0 -15.0 13.0 28.0 +4.0 -0.4 -0.5 240 0.0 Max. 42.0 42.0 26.0 4.0 7.0 -12.0 0.0 - Page 1 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Transmitter Measurements XU1006-QB, LSB Conv. Gain (dB) and Image Rejection (dBc) 10 5 5 CG (dB) and IR (dBc) CG (dB) and IR (dBc) XU1006-QB, USB Conv. Gain (dB) and Image Rejection (dBc) 10 0 Conv Gain Image Rej -5 -10 -15 0 -5 Conv Gain Image Rej -10 -15 -20 -20 -25 -25 36 37 38 39 40 41 36 42 37 38 -5 -5 -10 -15 -20 -25 17.5 18.0 18.5 19.0 41 42 19.5 20.0 -10 -15 -20 -25 -30 17.0 20.5 17.5 18.0 LO (GHz) 18.5 19.0 19.5 20.0 20.5 LO (GHz) RFout-2xLO (dBc) vs. LO Freq P_LO=+2 dBm, IF_in=-10dBm 25 40 XU1006-QB, 2xLO to RF Leakage (dBm), P_LO=+2dBm 0 2xLO to RF Leakage (dBm) 1xLO to RF Leakage (dBm) XU1006-QB, 1xLO to RF Leakage (dBm), P_LO=+2dBm 0 -30 17.0 39 RF LSB (GHz) [IF=2 GHz] RF USB (GHz) [IF=2 GHz] XU1006-QB, Output IP3 (dBm) 20 18 16 14 OIP3 (dBm) RFout-2xLO (dBc) 20 15 10 12 10 8 6 5 4 USB LSB 2 0 17.0 0 17.5 18.0 18.5 19.0 LO Freq (GHz) 19.5 20.0 20.5 36 37 38 39 RF (GHz) Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com 40 41 42 Page 2 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Transmitter Measurements (cont.) XU1006-QB, Conv Gain and IIP3 vs Vc (Dynamic Range) RF=38GHz, IF=2GHz, P_IF=-3dBm/tone XU1006-QB, Input IP3 (dBm) 18 20 15 14 10 CG (dB) and IIP3 (dBm) 16 IIP3 (dBm) 12 10 8 6 4 USB LSB 2 37 38 39 RF (GHz) 40 41 0 -5 -10 CG @ USB CG @ LSB IIP3 @ USB IIP3 @ LSB -15 -20 -25 0 36 5 -30 -2.0 42 -1.8 -1.4 -1.2 -1.0 Vc (V) -0.8 -0.6 -0.4 -0.2 0.0 -0.2 0 USB Conversion Gain Vs Control Voltage (Vc), 36GHz Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm 20 20 15 15 10 10 5 5 Conversion Gain (dB) Conversion Gain (dB) USB Conversion Gain Vs Control Voltage (Vc), 38GHz Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm -1.6 0 -5 -10 0 -5 -10 Conv Gain,36 GHz,Temp=-40ºC -15 Conv Gain,36 GHz,Temp=+25ºC Conv Gain,38 GHz,Temp=-40ºC -15 Conv Gain,38 GHz,Temp=+25ºC Conv Gain,36 GHz,Temp=+75ºC Conv Gain,38 GHz,Temp=+75ºC -20 -20 -25 -25 -30 -30 -2 -1.8 -1.6 -1.4 -1.2 -1 -0.8 -0.6 -0.4 -0.2 0 -2 -1.8 -1.6 -1.4 -1.2 Frequency (GHz) LSB IIP3 for XU1006-QB Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm, P_IF/tone=-5dBm, ? F=10 MHz -0.8 -0.6 -0.4 USB IIP3 for XU1006-QB Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm, P_IF/tone=-5dBm, ? F=10 MHz 20 20 18 18 16 16 14 14 12 12 IIP3 (dBm) IIP3(dBm) -1 Frequency (GHz) 10 10 8 8 IIP3 Temp=-40ºC 6 6 IIP3 Temp=+25ºC IIP3 Temp=-40ºC IIP3 Temp=+25ºC 4 IIP3 Temp=+75ºC 4 IIP3 Temp=+75ºC 2 2 0 0 36 37 38 39 Frequency (GHz) 40 41 42 36 37 38 39 40 41 Frequency (GHz) Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 3 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 42 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Transmitter Measurements (cont.) LSB Conversion Gain (dB) and IR (dBc) for XU1006-QB Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm, P_IF=-10dBm, IF_Frequency=2 GHz (x2)LO Leakage for XU1006-QB Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm, P_IF=-10dBm, IF_Frequency=2 GHz 20 10 15 5 10 5 Con.Gain(dB) and IR (dBc) x2LO Leakage (dBm) 0 -5 -10 0 -5 Con.Gain Temp=-40ºC Con.Gain Temp=+25ºC Con.Gain Temp=+75ºC -10 IR Temp=-40ºC IR Temp=+25ºC -15 IR Temp=+75ºC x2LO Leakage Temp=-40ºC -15 -20 x2LO Leakage Temp=+25ºC x2LO Leakage Temp=+75ºC -25 -30 -20 36 37 38 39 40 41 36 42 37 38 39 40 41 Frequency (GHz) Frequency (GHz) USB Conversion Gain (dB) and IR (dBc) for XU1006-QB Vg2=-0.5V, Vd=4V, Id=240mA, P_LO=+4dBm, P_IF=-10dBm, IF_Frequency=2 GHz 20 Con.Gain Temp=-40ºC Con.Gain Temp=+25ºC Con.Gain Temp=+75ºC IR Temp=-40ºC IR Temp=+25ºC IR Temp=+75ºC 15 10 Con.Gain(dB) and IR (dBc) 5 0 -5 -10 -15 -20 -25 -30 36 37 38 39 40 41 42 Frequency (GHz) Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 4 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 42 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Physical Dimensions Functional Schematic VD 28 GND GND 26 24 25 Package Pin-out Table 23 Pin Number 22 1 21 2 20 3 RF OUT 4 GND 5 6 VC 27 GND IF1 Balanced Image Reject Mixer PA Zin >> 1M LO Buffer x2 600 19 GND 18 LO IN 17 GND 4 7 8 9 11 18 25 27 All other pins Pin Name RF Out VC VG1 VG2 IF2 LO IN IF1 VD1 GND Pin Function RF Out Gain Control LNA, LO Amp Mixer, Doubler IF2 Input LO Input IF1 Input Drain Bias Ground Nominal Value Unit -2.0 to 0.0 -0.4 -0.5 Volts volts volts +2.0 dBm +4.0 volts 16 15 7 12.1 K 8 VG1 9 10 VG2 GND 11 12 IF2 GND 13 14 Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 5 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 Recommended Layout Environmental MSL - Gross Test Leak Compliant Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 6 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 App Note [1] Biasing - App Note [1] Biasing - The device is operated by biasing VD=4.0V with ID=240mA. Additionally, a mixer and doubler bias are also required with VG2 = -0.5V. Adjusting Vg2 above or below this value can adversely affect conversion gain, image rejection and intercept point performance. The VC bias pin controls an integrated attenuator where VC=-1.3 V provides the minimum attenuation and VC = 0.0 V provides the maximum attenuation (approximately 25 dB). It is recommended to use active biasing to keep the currents constant as the RF power and temperature vary; this gives the most reproducible results. Depending on the supply voltage available and the power dissipation constraints, the bias circuit may be a single transistor or a low power operational amplifier, with a low value resistor in series with the drain supply used to sense the current. The gate of the pHEMT is controlled to maintain correct drain current and thus drain voltage. The typical gate voltage needed to do this is VG1= -0.4V. Typically the gate is protected with Silicon diodes to limit the applied voltage. Also, make sure to sequence the applied voltage to ensure negative gate bias is available before applying the positive drain supply. MTTF MTTF is calculated from accelerated life-time data of single devices and assumes an isothermal back-plate. XU1006-QB, MTTF (yrs) vs. Backplate Temperature (°C) 1.0E+05 MTTF (Years) 1.0E+04 1.0E+03 1.0E+02 1.0E+01 1.0E+00 55 65 75 85 95 Temperature (°C) Bias Conditions: Vd=4.0V, Id=240 mA Typical Application RF OUT 37.0-39.5 GHz XP1005 XU1006-QB Coupler Mixer IF In 2 GHz X Buffer X2 LO(+2.0dBm) 17.5-18.75 GHz (USB Operation) 19.5-20.75 GHz (LSB Operation) Mimix Broadband MMIC-based 35.0-45.0 GHz Transmitter Block Diagram (Changing LO and IF frequencies as required allows design to operate as high as 42 GHz) Mimix Broadband's 36.0-42.0 GHz XU1006-QB GaAs Transmitter can be used in saturated radio applications and linear modulation schemes up to 128 QAM. The transmitter can be used in upper and lower sideband applications from 36.0-42.0 GHz. Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 7 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 App Note [3] USB/LSB Selection - LSB USB IF2 For Upper Side Band operation (USB): With IF1 and IF2 connected to the direct port (0º) and coupled port (90º) respectively as shown in the diagram, the USB signal will reside on the isolated port. The input port must be loaded with 50 ohms. For Lower Side Band operation (LSB): With IF1 and IF2 connected to the direct port (0º) and coupled port (90º) respectively as shown in the diagram, the LSB signal will reside on the input port. The isolated port must be loaded with 50 ohms. IF1 An alternate method of Selection of USB or LSB: LSB USB In Phas e Combiner In Phas e Combiner -90 -90 o o IF2 IF1 Factory Automation and Identification IF2 IF1 Mimix Designator Package Type Number of leads offered W Tape Width P1 Component Pitch P0 Hole Pitch Reel Diameter Units per Reel -QB QFN (7x7mm) 28 16mm 12mm 4mm 329mm (13in) 1000 Tape and Reel Packaging per the following conditions: Tape Width: 16 mm Tape Pitch (part to part): 12 mm Component Orientation: Parts are to be oriented with the PIN 1 closest to the tape's round sprocket holes on the tape’s trailing edge. Reel Diameter: 329 mm (13 inch) Note: Tape and Reel packaging is ordered with a -000T suffix. Package is available in 500 unit reels through designated sales channels. Minimum order quantities should be discussed with your local sales representative. Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 8 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws. 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm U1006-QB December 2007 - Rev 18-Dec-07 CAUTION! - Mimix Broadband MMIC Products contain gallium arsenide (GaAs) which can be hazardous to the human body and the environment. For safety, observe the following procedures: Do not ingest. Do not alter the form of this product into a gas, powder, or liquid through burning, crushing, or chemical processing as these by-products are dangerous to the human body if inhaled, ingested, or swallowed. Observe government laws and company regulations when discarding this product. This product must be discarded in accordance with methods specified by applicable hazardous waste procedures. Life Support Policy - Mimix Broadband's products are not authorized for use as critical components in life support devices or systems without the express written approval of the President and General Counsel of Mimix Broadband. As used herein: (1) Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. (2) A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Package Attachment - This packaged product from Mimix Broadband is provided as a rugged surface mount package compatible with high volume solder installation. Vacuum tools or other suitable pick and place equipment may be used to pick and place this part. Care should be taken to ensure that there are no voids or gaps in the solder connection so that good RF, DC and ground connections are maintained. Voids or gaps can eventually lead not only to RF performance degradation, but reduced reliability and life of the product due to thermal stress. Reflow Profile Ramp Up Rate Activation Time and Temperature Time Above Melting Point Max Peak Temperature Time Within 5 ºC of Peak Ramp Down Rate SnPb 3-4 ºC/sec 60-120 sec @ 140-160 ºC 60-150 sec 240 ºC 10-20 sec 4-6 ºC/sec Pb Free 3-4 ºC/sec 60-180 sec @ 170-200 ºC 60-150 sec 265 ºC 10-20 sec 4-6 ºC/sec Mimix Lead-Free RoHS Compliant Program - Mimix has an active program in place to meet customer and governmental requirements for eliminating lead (Pb) and other environmentally hazardous materials from our products. All Mimix RoHS compliant components are form, fit and functional replacements for their non-RoHS equivalents. Lead plating of our RoHS compliant parts is 100% matte tin (Sn) over copper alloy and is backwards compatible with current standard SnPb low-temperature reflow processes as well as higher temperature (260°C reflow) “Pb Free” processes. Part Number for Ordering XU1006-QB-0L00 XU1006-QB-0L0T XU1006-QB-EV1 Description Ni/Pd/Au plated RoHS compliant QFN 7x7 28L surface mount package in bulk quantity Ni/Pd/Au plated RoHS compliant QFN 7x7 28L surface mount package in tape and reel XU1006-QB Evaluation Module Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com Page 9 of 9 Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.