Z8 Family of Microcontrollers Z8 CPU User Manual UM001602-0904 ZiLOG Worldwide Headquarters • 532 Race Street • San Jose, CA 95126 Telephone: 408.558.8500 • Fax: 408.558.8300 • www.ZiLOG.com Z8 Family of Microcontrollers User Manual ii This publication is subject to replacement by a later edition. To determine whether a later edition exists, or to request copies of publications, contact: ZiLOG Worldwide Headquarters 532 Race Street San Jose, CA 95126 Telephone: 408.558.8500 Fax: 408.558.8300 www.ZiLOG.com Document Disclaimer ZiLOG is a registered trademark of ZiLOG Inc. in the United States and in other countries. All other products and/or service names mentioned herein may be trademarks of the companies with which they are associated. © 2004 by ZiLOG, Inc. All rights reserv ed. Information in this publication concerning the devices, applications, or technology described is intended to suggest possible uses and may be superseded. ZiLOG, INC. DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES, OR T ECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZiLOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED IN ANY MANNER T O USE OF INFORMATION, DEVICES, OR T ECHN OLOGY DESCRIBED HEREIN OR OTHERWISE. Devices sold by ZiLOG, Inc. are covered by warranty and limitation of liability provisions appearing in the ZiLOG, Inc. Terms and Conditions of Sale. ZiLOG, Inc. makes no warranty of merchantability or fitness for any purpose Except with the express written approval of ZiLOG, use of information, devices, or technology as critical components of life support systems is not authorized. No licenses are conveyed, implicitly or otherwise, by this document under any intellectual property rights. UM001602-0904 Z8 CPU User Manual iii Revision History Each instance in Table 1 reflects a change to this document from its previous revision. To see more detail, click the appropriate link in the table. Table 1. Revision History of this Document Date Sept. 2004 Revision Level Section 02 UM001602-0904 Description Formatted to current publication standards Page # All Revision History Z8 Family of Microcontrollers User Manual iv Revision History UM001602-0904 Z8 CPU User Manual v Table of Contents Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii List of Figures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Z8 CPU Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Development Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Z8 CPU Standard Register File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 General-Purpose Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 RAM Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Working Register Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Error Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Z8 Expanded Register File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Z8 Control and Peripheral Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Standard Z8 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Expanded Z8 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Program Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Z8 External Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 External Data Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Z8 Stacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Clock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frequency Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCLK ÷ TCLK Divide-By-16 Select . . . . . . . . . . . . . . . . . . . . . . . . . External Clock Divide-By-Two . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Oscillator Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UM001602-0904 33 33 33 34 34 35 Table of Contents Z8 Family of Microcontrollers User Manual vi Oscillator Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indications of an Unreliable Design . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Board Design Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Crystals and Resonators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LC Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 37 38 38 40 43 44 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Reset Pin, Internal POR Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Watch–Dog Timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Power-On-Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 I/O Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mode Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input and Output Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General I/O Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Read/Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handshake Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General I/O Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Read/Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handshake Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Port I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Read/Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handshake Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Port I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Read/Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table of Contents 61 61 62 63 65 67 68 68 68 71 73 73 74 78 78 80 80 87 88 90 UM001602-0904 Z8 CPU User Manual vii I/O Port Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Full Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Analog Comparators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Comparator Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Comparator Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Comparator Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Comparator Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Run Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Halt Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Stop Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Open-Drain Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Low EMI Emission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Input Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Z8 CMOS Autolatches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Autolatch Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Counters and Timers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescalers and Counter/Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Counter/Timer Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Load and Enable Count Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescaler Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TOUT Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TIN Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Clock Input Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gated Internal Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triggered Input Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Retriggerable Input Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cascading Counter/Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UM001602-0904 115 117 120 120 122 124 127 129 129 130 131 132 132 Table of Contents Z8 Family of Microcontrollers User Manual viii Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Request Register Logic and Timing . . . . . . . . . . . . . . . . . . . . . Interrupt Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Priority Register Initialization . . . . . . . . . . . . . . . . . . . . . . Interrupt Mask Register Initialization . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Request Register Initialization . . . . . . . . . . . . . . . . . . . . . . IRQ Software Interrupt Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vectored Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vectored Interrupt Cycle Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . Nesting of Vectored Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polled Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 139 139 141 141 143 143 145 147 150 150 153 154 154 155 Power-Down Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Halt Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stop Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stop-Mode Recovery Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 157 158 160 Serial Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Bit-Rate Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Receiver Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receiver Shift Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overwrites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Framing Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overwrites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 165 166 170 170 171 171 172 173 174 174 175 Table of Contents UM001602-0904 Z8 CPU User Manual ix Serial Peripheral Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPI Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPI Compare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPI Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receive Character Available and Overrun . . . . . . . . . . . . . . . . . . . . . . . 176 179 180 180 182 External Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Addressing Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Stacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bus Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Address Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extended Bus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Instruction Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z8 Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 187 188 189 190 191 192 194 195 195 198 200 Instruction Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Processor Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Carry Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Zero Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sign Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overflow Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Decimal Adjust Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Half Carry Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Notation and Binary Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly Language Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z8 Instruction Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Op Code Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 205 206 206 206 207 207 207 208 210 212 213 222 UM001602-0904 Table of Contents Z8 Family of Microcontrollers User Manual x Instruction Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 Customer Feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 Table of Contents UM001602-0904 Z8 CPU User Manual xi List of Figures Figure 1. Z8 CPU Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2. 16-Bit Register Addressing . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 3. Accessing Individual Bits (Example) . . . . . . . . . . . . . . . . . 9 Figure 4. Working Register Addressing Examples . . . . . . . . . . . . . 12 Figure 5. Register Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Figure 6. Expanded Register File Architecture . . . . . . . . . . . . . . . . 15 Figure 7. Register Pointer Example . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 8. Z8 Program Memory Map . . . . . . . . . . . . . . . . . . . . . . . . 27 Figure 9. External Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 10. Stack Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 11. Stack Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Figure 12. Z8® CPU Clock Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Figure 13. Stop-Mode Recovery Register . . . . . . . . . . . . . . . . . . . . . 34 Figure 14. External Clock Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 15. Port Configuration Register . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 16. Pierce Oscillator with Internal Feedback Circuit . . . . . . . 37 Figure 17. Circuit Board Design Rules . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 18. Crystal/Ceramic Resonator Oscillator . . . . . . . . . . . . . . . . 41 Figure 19. LC Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 20. External Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 21. RC Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Figure 22. Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 UM001602-0904 List of Figures Z8 Family of Microcontrollers User Manual xii Figure 23. Example of External Power-On Reset Circuit . . . . . . . . . . 50 Figure 24. Example of Z8 Reset with RESET Pin, WDT, SMR, and POR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Figure 25. Example of Z8 Reset with WDT, SMR, and POR . . . . . . 54 Figure 26. Example of Z8 Watch–Dog Timer Mode Register . . . . . . 56 Figure 27. Example of Z8 with Simple SMR and POR . . . . . . . . . . . 59 Figure 28. I/O Ports and Mode Registers . . . . . . . . . . . . . . . . . . . . . . 62 Figure 29. Ports 0, 1, 2 Generic Block Diagram . . . . . . . . . . . . . . . . 64 Figure 30. Port 0 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger . . . . . . . . . . . . . . . . . . . . . 66 Figure 31. Port 0 Configuration with TTL Level Shifter . . . . . . . . . . 67 Figure 32. Port 0 I/O Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Figure 33. Port 0 Handshake Operation . . . . . . . . . . . . . . . . . . . . . . . 69 Figure 34. Port 1 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger . . . . . . . . . . . . . . . . . . . . . 70 Figure 35. Port 1 Configuration with TTL Level Shifter . . . . . . . . . . 71 Figure 36. Port 1 I/O Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Figure 37. Handshake Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Figure 38. Port 2 I/O Mode Configuration . . . . . . . . . . . . . . . . . . . . . 74 Figure 39. Port 2 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger . . . . . . . . . . . . . . . . . . . . . 75 Figure 40. Port 2 Configuration with TTL Level Shifter . . . . . . . . . . 76 Figure 41. Port 2 Configuration with Open-Drain Capability, Autolatch, Schmitt-Trigger and SPI . . . . . . . . . . . . . . . . . 77 Figure 42. Port 2 Handshake Configuration . . . . . . . . . . . . . . . . . . . . 79 List of Figures UM001602-0904 Z8 CPU User Manual xiii Figure 43. Port 2 Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Figure 44. Port 3 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Figure 45. Port 3 Configuration with Comparator, Autolatch, and Schmitt-Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Figure 46. Port 3 Configuration with Comparator . . . . . . . . . . . . . . . 84 Figure 47. Port 3 Configuration with SPI and Comparator Outputs . 86 Figure 48. Port 3 Configuration with TTL Level Shifter and Autolatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Figure 49. Port 3 Mode Register Configuration . . . . . . . . . . . . . . . . . 88 Figure 50. Z8 Input Handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Figure 51. Z8 Output Handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Figure 52. Output Strobed Handshake on Port 2 . . . . . . . . . . . . . . . . 94 Figure 53. Input Strobed Handshake on Port 2 . . . . . . . . . . . . . . . . . 94 Figure 54. Port 0/1 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Figure 55. Port 2 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Figure 56. Port 3 Mode Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Figure 57. Port 3 Input Analog Selection . . . . . . . . . . . . . . . . . . . . . . 99 Figure 58. Port 3 Comparator Output Selection . . . . . . . . . . . . . . . . 100 Figure 59. Port Configuration of Comparator Inputs on P31, P32, and P33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Figure 60. Port 3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Figure 61. Port 2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Figure 62. Port Configuration Register . . . . . . . . . . . . . . . . . . . . . . 106 Figure 63. Diode Input Protection . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Figure 64. OTP Diode Input Protection . . . . . . . . . . . . . . . . . . . . . . 110 UM001602-0904 List of Figures Z8 Family of Microcontrollers User Manual xiv Figure 65. Simplified CMOS Z8 I/O Circuit . . . . . . . . . . . . . . . . . . 111 Figure 66. Autolatch Equivalent Circuit . . . . . . . . . . . . . . . . . . . . . . 113 Figure 67. Effect of Pulldown Resistors on Autolatches . . . . . . . . . 114 Figure 68. Counter/Timer Block Diagram . . . . . . . . . . . . . . . . . . . . 116 Figure 69. Counter/Timer Register Map . . . . . . . . . . . . . . . . . . . . . . 118 Figure 70. Prescaler 0 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Figure 71. Prescaler 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Figure 72. Counter/Timer 0 and 1 Registers . . . . . . . . . . . . . . . . . . . 119 Figure 73. Timer Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Figure 74. Starting The Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Figure 75. Counting Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Figure 76. Timer Mode Register (TOUT Operation) . . . . . . . . . . . . . 124 Figure 77. Port 3 Mode Register (TOUT Operation) . . . . . . . . . . . . . 125 Figure 78. T0 and T1 Output Through TOUT . . . . . . . . . . . . . . . . . . 126 Figure 79. Internal Clock Output Through TOUT . . . . . . . . . . . . . . . 127 Figure 80. Timer Mode Register (TIN Operation) . . . . . . . . . . . . . . 128 Figure 81. Prescaler 1 Register (TIN Operation) . . . . . . . . . . . . . . . . 128 Figure 82. External Clock Input Mode . . . . . . . . . . . . . . . . . . . . . . . 129 Figure 83. Gated Clock Input Mode . . . . . . . . . . . . . . . . . . . . . . . . . 130 Figure 84. Triggered Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Figure 85. Cascaded Counter/Timers . . . . . . . . . . . . . . . . . . . . . . . . 132 Figure 86. Counter/Timer Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Figure 87. Prescaler 1 Register Reset . . . . . . . . . . . . . . . . . . . . . . . . 133 Figure 88. Prescaler 0 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 List of Figures UM001602-0904 Z8 CPU User Manual xv Figure 89. Timer Mode Register Reset . . . . . . . . . . . . . . . . . . . . . . 135 Figure 90. Interrupt Control Registers . . . . . . . . . . . . . . . . . . . . . . . 137 Figure 91. Interrupt Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 138 Figure 92. Interrupt Sources IRQ0-IRQ2 Block Diagram . . . . . . . . 140 Figure 93. Interrupt Source IRQ3 Block Diagram . . . . . . . . . . . . . . 141 Figure 94. IRQ Register Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Figure 95. Interrupt Request Timing . . . . . . . . . . . . . . . . . . . . . . . . 143 Figure 96. Interrupt Priority Register . . . . . . . . . . . . . . . . . . . . . . . . 144 Figure 97. Interrupt Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Figure 98. Interrupt Request Register . . . . . . . . . . . . . . . . . . . . . . . . 148 Figure 99. IRQ Reset Functional Logic Diagram . . . . . . . . . . . . . . . 149 Figure 100. Effects of an Interrupt on the Stack . . . . . . . . . . . . . . . . . 151 Figure 101. Interrupt Vectoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Figure 102. Z8 Interrupt Acknowledge Timing . . . . . . . . . . . . . . . . . 153 Figure 103. Stop-Mode Recovery Register . . . . . . . . . . . . . . . . . . . . 160 Figure 104. Stop-Mode Recovery Source . . . . . . . . . . . . . . . . . . . . . 163 Figure 105. UART Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Figure 106. Port 3 Mode Register and Bit-Rate Generation . . . . . . . 167 Figure 107. Bit Rate Divide Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Figure 108. Prescaler 0 Register Bit-Rate Generation . . . . . . . . . . . . 169 Figure 109. Timer Mode Register Bit Rate Generation . . . . . . . . . . . 169 Figure 110. Receiver Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Figure 111. Receiver Data Formats . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Figure 112. Port 3 Mode Register Parity . . . . . . . . . . . . . . . . . . . . . . 173 UM001602-0904 List of Figures Z8 Family of Microcontrollers User Manual xvi Figure 113. Transmitter Data Formats . . . . . . . . . . . . . . . . . . . . . . . . 175 Figure 114. SIO Register Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Figure 115. P3M Register Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Figure 116. SPI Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Figure 117. SPI System Configuration . . . . . . . . . . . . . . . . . . . . . . . . 181 Figure 118. SPI Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Figure 119. SPI Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Figure 120. SPI Data In/Out Configuration . . . . . . . . . . . . . . . . . . . . 184 Figure 121. SPI Clock/SPI Slave Select Output Configuration . . . . . 185 Figure 122. Z8 CPU External Interface Pins . . . . . . . . . . . . . . . . . . . 187 Figure 123. External Address Configuration . . . . . . . . . . . . . . . . . . . 190 Figure 124. Z8 Stack Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Figure 125. Port 3 Data Memory Operation . . . . . . . . . . . . . . . . . . . . 192 Figure 126. External Instruction Fetch or Memory Read Cycle . . . . . 193 Figure 127. External Memory Write Cycle . . . . . . . . . . . . . . . . . . . . . 194 Figure 128. Extended External Instruction Fetch or Memory Read Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Figure 129. Extended External Memory Write Cycle . . . . . . . . . . . . 197 Figure 130. Extended Bus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Figure 131. Instruction Cycle Timing (1-Byte Instructions) . . . . . . . 199 Figure 132. Instruction Cycle Timing (2- and 3-Byte Instructions) . . 200 Figure 133. Z8 Flag Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Figure 134. Op Code Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 List of Figures UM001602-0904 Z8 CPU User Manual xvii List of Tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. UM001602-0904 Revision History of this Document . . . . . . . . . . . . . . . . . . . iii ZiLOG General-Purpose Microcontroller Product Family . 4 Z8 Standard Register File . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Working Register Groups . . . . . . . . . . . . . . . . . . . . . . . . . 11 ERF Bank Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Register Pointer Access Example . . . . . . . . . . . . . . . . . . . 18 ERF Bank C Access Example . . . . . . . . . . . . . . . . . . . . . . 20 Z8 Expanded Register File Bank Layout . . . . . . . . . . . . . 20 Expanded Register File Register Bank C . . . . . . . . . . . . . 23 Expanded Register File Bank 0 . . . . . . . . . . . . . . . . . . . . . 24 Expanded Register File Bank F . . . . . . . . . . . . . . . . . . . . . 25 Crystal/Resonator Characteristics . . . . . . . . . . . . . . . . . . . 41 Sample Control and Peripheral Register Reset Values (ERF Bank 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Expanded Register File Bank 0 Reset Values at RESET . 51 Sample Expanded Register File Bank C Reset Values . . . 51 Sample Expanded Register File Bank F Reset Values . . . 52 Time-Out Period of the WDT . . . . . . . . . . . . . . . . . . . . . . 57 Port 3 Line Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Interrupt Types, Sources, and Vectors . . . . . . . . . . . . . . 139 Interrupt Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Interrupt Group Priority . . . . . . . . . . . . . . . . . . . . . . . . . 145 IRQ Register Configuration . . . . . . . . . . . . . . . . . . . . . . 149 Stop-Mode Recovery Source . . . . . . . . . . . . . . . . . . . . . 161 UART Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Bit Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 List of Tables Z8 Family of Microcontrollers User Manual xviii Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Table 41. Table 42. List of Tables SPI Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . Load Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arithmetic Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . Logical Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Program Control Instructions . . . . . . . . . . . . . . . . . . . . . Bit Manipulation Instructions . . . . . . . . . . . . . . . . . . . . . Block Transfer Instructions . . . . . . . . . . . . . . . . . . . . . . . Rotate and Shift Instructions . . . . . . . . . . . . . . . . . . . . . . CPU Control Instructions . . . . . . . . . . . . . . . . . . . . . . . . Z8 Flag Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flag Settings Definitions . . . . . . . . . . . . . . . . . . . . . . . . . Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Notational Shorthand . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of Z8 Instruction Set . . . . . . . . . . . . . . . . . . . . Summary of Z8 Address Modes . . . . . . . . . . . . . . . . . . . Process Manipulation Functions . . . . . . . . . . . . . . . . . . . 177 201 202 202 202 203 203 204 204 208 208 209 210 211 213 221 223 UM001602-0904 Z8 CPU User Manual 1 Z8 CPU Product Overview The ZiLOG Z8 microcontroller (MCU) product line continues to expand with new product introductions. ZiLOG MCU products are targeted for cost-sensitive, high-volume applications including consumer, automotive, security, and HVAC. It includes ROM-based products geared for highvolume production (where software is stable) and one-time programmable (OTP) equivalents for prototyping as well as volume production where time to market or code flexibility is critical (see Table 1 on page 4). A variety of packaging options are available including plastic DIP, SOIC, PLCC, and QFP. A generalized Z8 CPU® block diagram is shown in Figure 1. The same on-chip peripherals are used across the MCU product line with the primary differences being the amount of ROM/RAM, number of I/O lines present, and packaging/temperature ranges available. This allows code written for one MCU device to be easily ported to another family member. Key Features General-Purpose Register File. Every RAM register acts like an accumulator, speeding instruction execution and maximizing coding efficiency. Working register groups allow fast context switching. Flexible I/O. I/O byte, nibble, and/or bit programmable as inputs or outputs. Outputs are software programmable as open-drain or push–pull on a port basis. Inputs are Schmitt-triggered with autolatches to hold unused inputs at a known voltage state. Analog Inputs. Three input pins are software programmable as digital or analog inputs. When in analog mode, two comparator inputs are provided with a common reference input. These inputs are ideal for a variety of common functions, including threshold level detection, analog-to-digital UM001602-0904 Z8 CPU Product Overview Z8 Family of Microcontrollers User Manual 2 conversion, and short circuit detection. Each analog input provides a unique maskable interrupt input. Timer/Counter. The Timer/Counter (T/C) consists of a programmable 6bit prescaler and 8-bit downcounter, with maskable interrupt upon end-ofcount. Software controls T/C load/start/stop, countdown read (at any time on the fly), and maskable end-of-count interrupt. Special functions available include TIN (external counter input, external gate input, or external trigger input) and TOUT (external access to timer output or the internal system clock.) These special functions allow accurate hardware input pulse measurement and output waveform generation. Interrupts. There are six vectored interrupt sources with software-programmable enable and priority for each of the six sources. Watch–Dog Timer. An internal Watch–Dog Timer (WDT) circuit is included as a fail-safe mechanism so that if software strays outside the bounds of normal operation, the WDT will time-out and reset the MCU. To maximize circuit robustness and reliability, the default WDT clock source is an internal RC circuit (isolated from the device clock source). Auto Reset/Low-Voltage Protection. All family devices have internal Power-On Reset. ROM devices add low-voltage protection. Low-voltage protection ensures the MCU is in a known state at all times (in active RUN mode or RESET) without external hardware (or a device reset pin). Low-EMI Operation. Mode is programmable via software or as a mask option. This new option provides for reduced radiated emission via clock and output drive circuit changes. Low-Power. CMOS with two standby modes; STOP and HALT. Full Z8 Instruction Set. Forty-eight basic instructions, supported by six addressing modes with the ability to operate on bits, nibbles, bytes, and words. Z8 CPU Product Overview UM001602-0904 Z8 CPU User Manual 3 Output Input GND VCC XTAL AS DS R/W RESET Machine Timing & Instruction Control Port 3 RESET, WDT, POR ALU Counter/ Timers (2) FLAG Interrupt Control Analog Comparators (2) Prg. Memory 512/K x 8-Bit Register Pointer Register File 256 x 8-Bit Port 2 Port 0 4 I/O (Bit Programmable) 4 Address or I/O (Nibble Programmable) Program Counter Port 1 8 Address/Data or I/O (Byte Programmable) Figure 1. Z8 CPU Block Diagram UM001602-0904 Z8 CPU Product Overview Z8 Family of Microcontrollers User Manual 4 Product Development Support The Z8® MCU product line is fully supported with a range of cross assemblers, C compilers, ICEBOX emulators, single and gang OTP/ EPROM programmers, and software simulators. The Z86CCP01ZEM low-cost Z8 CCP™ real-time emulator/programmer kit was designed specifically to support all of the products outlined in Table 1. Table 1. ZiLOG General-Purpose Microcontroller Product Family Product ROM/ RAM I/0 T/C AN INT Z86C03 512/60 14 1 2 6 F Y Y Y 8 18 Z86E03 512/60 14 1 2 6 F Y N Y 8 18 Z86C04 1K/124 14 2 2 6 F Y Y Y 8 18 Z86E04 1K/124 14 2 2 6 F Y N Y 8 18 Z86C06 1K/124 14 2 2 6 P Y Y Y 12 18 Z86E06 1K/124 14 2 2 6 P Y N Y 12 18 Z86C08 2K/124 14 2 2 6 F Y Y Y 12 18 Z86E08 2K/124 14 2 2 6 F Y N Y 12 18 Z86C30 4K/236 24 2 2 6 P Y Y Y 12 28 Z86E30 4K/236 24 2 2 6 P Y N Y 12 28 Z86C31 2K/124 24 2 2 6 P Y Y Y 8 28 Z86E31 2K/124 24 2 2 6 P Y N Y 8 28 Z86C40 4K/236 32 2 2 6 P Y Y Y 16 40/44 Z86E40 4K/236 32 2 2 6 P Y N Y 16 40/44 WDT POR VBO RC Speed Pin (MHz) Count *Note: Z86Cxx signify ROM devices; 86xx signify EPROM devices; F = fixed; P = programmable Z8 CPU Product Overview UM001602-0904 Z8 CPU User Manual 5 The Z86CCP01ZEM kit comes with: • • • Z8 CCP Evaluation Board • • 1999 ZiLOG Technical Library Z8 CCP Power Cable ZiLOG Developer’s Studio (ZDS) CD-ROM , Including WindowsBased GUI Host Software Z8 CCP User Manual A Z8 CCP Emulator Accessory Kit (Z8CCP00ZAC) is also available and provides an RS-232 cable and power cable along with the 28- and 40- pin ZIF sockets and 28- and 40- pin target connector cables required to emulate/program 28/40 pin devices. UM001602-0904 Z8 CPU Product Overview Z8 Family of Microcontrollers User Manual 6 Z8 CPU Product Overview UM001602-0904 Z8 CPU User Manual 7 Address Space Introduction Four address spaces are available for the Z8® CPU: • The Z8® Standard Register File contains addresses for peripheral, control, all general-purpose, and all I/O port registers. This is the default register file specification. • The Z8® Expanded Register File (ERF) contains addresses for control and data registers for additional peripherals/features. • Z8 external program memory contains addresses for all memory locations having executable code and/or data. • Z8 external data memory contains addresses for all memory locations that hold data only, whether internal or external. Z8 CPU Standard Register File The Z8® Standard Register File totals up to 256 consecutive bytes (Registers). The register file consists of 4 I/O ports (00h–03h), 236 GeneralPurpose Registers (04h–EFh), and 16 control registers (F0h–FFh). Table 2 shows the layout of the register file, including register names, locations, and identifiers. Table 2. Z8 Standard Register File UM001602-0904 Hex Address Register Identifier Register Description FF SPL Stack Pointer Low Byte FE SPH Stack Pointer High Byte FD RP Register Pointer Address Space Z8 Family of Microcontrollers User Manual 8 Table 2. Z8 Standard Register File (Continued) Hex Address Register Identifier Register Description FC FLAGS Program Control Flags FB IMR Interrupt Mask Register FA IRQ Interrupt Request Register F9 IPR Interrupt Priority Register F8 P01M Port 0–1 Mode Register F7 P3M Port 3 Mode Register F6 P2M Port 2 Mode Register F5 PRE0 T0 Prescaler F4 T0 Timer/Counter 0 F3 PRE1 T1 Prescaler F2 T1 Timer/Counter 1 F1 TMR Timer Mode F0 SIO Serial I/O EF R239 General-Purpose Registers (GPR) 04 R4 03 P3 Port 3 02 P2 Port 2 01 P1 Port 1 00 P0 Port 0 Registers can be accessed as either 8-bit or 16-bit registers using Direct, Indirect, or Indexed Addressing. All 236 general-purpose registers can be Address Space UM001602-0904 Z8 CPU User Manual 9 referenced or modified by any instruction that accesses an 8-bit register, without the requirement for special instructions. Registers accessed as 16 bits are treated as even-odd register pairs (there are 118 valid pairs). In this case, the data’s Most Significant Byte (MSB) is stored in the even numbered register, while the Least Significant Byte (LSB) goes into the next higher odd numbered register. See Figure 2. MSB Rn LSB Rn+1 n = Even Address Figure 2. 16-Bit Register Addressing By using a logical instruction and a mask, individual bits within registers can be accessed for bit set, bit clear, bit complement, or bit test operations. For example, the instruction AND R15, MASK performs a bit clear operation. Figure 3 shows this example. 0 1 1 1 0 0 0 0 R15 1 1 0 1 1 1 1 1 MASK AND R15, DFh 0 1 0 1 ;Clear Bit 5 of Working Register 15 0 0 0 0 R15 Figure 3. Accessing Individual Bits (Example) UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 10 When instructions are executed, registers are read when defined as sources and written when defined as destinations. All General-Purpose Registers function as accumulators, address pointers, index registers, stack areas, or scratch pad memory. General-Purpose Registers General-Purpose Registers (GPR) are undefined after the device is powered up. The registers keep their last value after any reset, as long as the reset occurs in the VCC voltage-specified operating range. It will not keep its last state from a VLV reset if VCC drops below 1.8v. Note: Registers in Bank E0-EF may only be accessed through the working register and indirect addressing modes. Direct access cannot be used because the 4-bit working register address mode already uses the format [E | dst], where dst represents the working register number from 0h to Fh. RAM Protect The upper portion of the register file address space 80h to EFh (excluding the control registers) may be protected from reading and writing. The RAM Protect bit option is mask-programmable and is selected by the customer when the ROM code is submitted. After the mask option is selected, the user activates this feature from the internal ROM code to turn off/on the RAM Protect by loading either a 0 or 1 into the IMR register, bit D6. A 1 in D6 enables RAM Protect. Only devices that use registers 80h to EFh offer this feature. Working Register Groups Z8 instructions can access 8-bit registers and register pairs (16-bit words) using either 4-bit or 8-bit address fields. 8-bit address fields refer to the actual address of the register. For example, Register 58h is accessed by calling upon its 8-bit binary equivalent, 01011000 (58h). With 4-bit addressing, the register file is logically divided into 16 Working Register Groups of 16 registers each, as shown in Table 3. These 16 Address Space UM001602-0904 Z8 CPU User Manual 11 registers are known as Working Registers. A Register Pointer (one of the control registers, FDh) contains the base address of the active Working Register Group. The high nibble of the Register Pointer determines the current Working Register Group. When accessing one of the Working Registers, the 4-bit address of the Working Register is combined within the upper four bits (high nibble) of the Register Pointer, thus forming the 8-bit actual address. Figure 4 illustrates this operation. Because working registers are typically specified by short format instructions, there are fewer bytes of code required, which reduces execution time. In addition, when processing interrupts or changing tasks, the Register Pointer speeds context switching. A special Set Register Pointer (SRP) instruction sets the contents of the Register Pointer. Table 3. Working Register Groups Register Pointer (FDh) High Nibble UM001602-0904 Working Register Actual Registers Group (Hex) (Hex) 1111b F F0–FF 1110b E E0–EF 1101b D D0–DF 1100b C C0–CF 1011b B B0–BF 1010b A A0–AF 1001b 9 90–9F 1000b 8 80–8F 0111b 7 70–7F 0110b 6 60–6F 0101b 5 50–5F 0100b 4 40–4F Address Space Z8 Family of Microcontrollers User Manual 12 Table 3. Working Register Groups (Continued) Register Pointer (FDh) High Nibble 0 0 1 1 1 1 Working Register Actual Registers Group (Hex) (Hex) 0011b 3 30–3F 0010b 2 20–2F 0001b 1 10–1F 0000b 0 00–0F 1 1 0 0 0 0 1 1 0 1 0 1 1 0 Register Pointer (FDh), Standard Register File 1 1 1 1 INC R6 (instruction, short format) Actual register address (76h) Figure 4. Working Register Addressing Examples Address Space UM001602-0904 Z8 CPU User Manual 13 R7 R6 R5 R4 R3 R2 R1 R0 R253 (Register Pointer) The upper nibble of the register file address, provided by the register pointer, specifies the active working-register group. FF F0 EF 80 7F 70 6F 60 5F 50 4F 40 3F 30 2F 20 1F 10 0F Working Register Group F Specified Working Register Group 00 The lower nibble of the register file address (provided by the instruction) points to the specified register. Working Register Group 1 R15 to R0 Working Register Group 0 R15 to R4 I/O Ports R3 to R0 *Note: The full register file is shown. Please refer to the selected device product specification for actual file size. Figure 5. Register Pointer Error Conditions Registers in the Z8® Standard Register File must be correctly used because certain conditions produce inconsistent results and should be avoided. • UM001602-0904 Registers F3h and F5h–F9h are write-only registers. If an attempt is made to read these registers, FFh is returned. Reading any write-only register will return FFh. Address Space Z8 Family of Microcontrollers User Manual 14 • When register FDh (Register Pointer) is read, the least significant four bits (lower nibble) will indicate the current Expanded Register File Bank. (Example: 0000 indicates the Standard Register File, while 1010 indicates Expanded Register File Bank A.) • When Ports 0 and 1 are defined as address outputs, registers 00h and 01h will return 1s in each address bit location when read. • Writing to bits that are defined as timer output, serial output, or handshake output will have no effect. • The Z8® CPU instruction DJNZ uses any general-purpose working register as a counter. • Logical instructions such as OR and AND require that the current contents of the operand be read. They therefore will not function properly on write-only registers. • The WDTMR register must be written within the first 60 internal system clocks (SCLK) of operation after a reset. Z8 Expanded Register File The standard register file of the Z8® CPU has been expanded to form 16 Expanded Register File (ERF) Banks, as shown in Figure 6. Each ERF Bank consists of up to 256 registers (the same amount as in the Standard Register File) that can then be divided into 16 Working Register Groups. This expansion allows for access to additional feature/peripheral control and data registers. Address Space UM001602-0904 Z8 CPU User Manual 15 Expanded Register File Bank (F) (F) 0F WDTMR (F) 0E Reserved Register Pointer (F) 0D Reserved D7 D6 D5 D4 D3 D2 D1 D0 (F) 0C Reserved (F) 0B SMR Working Register Group Pointer Expanded Register Group Pointer (F) 0A Z8 Register File FF F0 Reserved (F) 09 Reserved (F) 08 Reserved (F) 07 Reserved (F) 06 Reserved (F) 05 Reserved (F) 04 Reserved (F) 03 Reserved (F) 02 Reserved (F) 01 Reserved (F) 00 PCON 7F Expanded Register File Bank (0) Expanded Register File Bank (C) (C) 0F Reserved (C) 0E Reserved (C) 0D Reserved (C) 0C Reserved (C) 0B Reserved (C) 0A Reserved (C) 09 Reserved (C) 08 Reserved (C) 07 Reserved 0F (0) 0F GPR 00 (0) 0E GPR (C) 06 Reserved (0) 0D GPR (C) 05 Reserved (0) 0C GPR (C) 04 Reserved (0) 0B GPR (C) 03 Reserved (0) 0A GPR (C) 02 SCON (0) 09 GPR (C) 01 RXBUF (0) 08 GPR (C) 00 SCOMP (0) 07 GPR (0) 06 GPR (0) 05 GPR (0) 04 GPR (0) 03 P3 (0) 02 P2 (0) 01 P1 (0) 00 P0 *Note: The fully implemented register file is shown. Please refer to the specific product specification for actual register file architecture implemented. Figure 6. Expanded Register File Architecture UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 16 Currently, three out of the possible sixteen Z8 ERF Banks have been implemented. ERF Bank 0, also known as the Z8® Standard Register File, has all 256 bytes defined, as shown in Figure 7. Only Working Register Group 0 (register addresses 00h to 0Fh) have been defined for ERF Bank C and ERF Bank F (see Table 4). All other working register groups in ERF Banks C and F, as well as the remaining thirteen ERF Banks, are not implemented. All are reserved for future use. When an ERF Bank is selected, register addresses 00h to 0Fh access those sixteen ERF Bank registers—in effect replacing the first sixteen locations of the Z8® Standard Register File. For example, if ERF Bank C is selected, the Z8® Standard Registers 00h through 0Fh are no longer accessible. Registers 00h through 0Fh are now the 16 registers from ERF Bank C, Working Register Group 0. No other Z8 Standard Registers are affected because only Working Register Group 0 is implemented in ERF Bank C. Access to the ERF is accomplished through the Register Pointer (FDh). The lower nibble of the Register Pointer determines the ERF Bank while the upper nibble determines the Working Register Group within the register file, as Figure 7 shows. 0111 Working Register Group 1100 Expanded Register Bank Select ERF Bank Ch Working Register Group 7h Figure 7. Register Pointer Example Address Space UM001602-0904 Z8 CPU User Manual 17 The value of the lower nibble in the Register Pointer (FDh) corresponds to the ERF Bank identification. Table 4 shows the lower nibble value and the register file assigned to it. Table 4. ERF Bank Address Register Pointer (FDh) Low Nibble Hex Register File 0000b 0 Z8 Standard Register File.* 0001b 1 Expanded Register File Bank 1. 0010b 2 Expanded Register File Bank 2. 0011b 3 Expanded Register File Bank 3.. 0100b 4 Expanded Register File Bank 4 0101b 5 Expanded Register File Bank 5.. 0110b 6 Expanded Register File Bank 6 0111b 7 Expanded Register File Bank 7.. 1000b 8 Expanded Register File Bank 8 1001b 9 Expanded Register File Bank 9.. 1010b A Expanded Register File Bank A 1011b B Expanded Register File Bank B. 1100b C Expanded Register File Bank C. 1101b D Expanded Register File Bank D.. 1110b E Expanded Register File Bank E F Expanded Register File Bank F. 1111b ® *Note: the Z8 Standard Register File is equivalent to Expanded Register File Bank 0. UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 18 The upper nibble of the register pointer selects which group of 16 bytes in the Register File, out of the 256 total bytes, will be accessed as working registers. Table 5 shows an example. Table 5. Register Pointer Access Example R253 RP = 00h ;ERF Bank 0, Working Reg. Group 0. R0 = Port 0 = 00h R1 = Port 1 = 01h R2 = Port 2 = 02h R3 = Port 3 = 03h R11 = GPR 0Bh R15 = GPR 0Fh If R253 RP = 0Fh ;ERF Bank F, Working Reg. Group 0. R0 = PCON = 00h R1 = Reserved = 01h R2 = Reserved = 02h R11 = SMR = 0Bh R15 = WDTMR = 0Fh Address Space UM001602-0904 Z8 CPU User Manual 19 Table 5. Register Pointer Access Example (Continued) If R253 RP = FFh ;ERF Bank F, Working Reg. Group F. 00h = PCON R0 = SI0 01h = Reserved R1 = TMR 02h = Reserved ... R2 = T1 0Bh = SMR ... R15 = SPL 0Fh = WDTMR Because enabling an ERF Bank (C or F) only changes register addresses 00h to 0Fh, the working register pointer can be used to access either the selected ERF Bank (Bank C or F, Working Register Group 0) or the Z8® Standard Register File (ERF Bank 0, Working Register Groups 1 through F). When an ERF Bank other than Bank 0 is enabled, the first 16 bytes of the Z8® Standard Register File (I/O ports 0 to 3, Groups 4 to F) are no longer accessible (the selected ERF Bank, Registers 00h to 0Fh are accessed instead). It is important to re-initialize the Register Pointer to enable ERF Bank 0 when these registers are required for use. The SPI register is mapped into ERF Bank C. Access is easily done using the example in Table 6. UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 20 Table 6. ERF Bank C Access Example LD RP, #0Ch ;Select ERF Bank C working ;register group 0 for access. LD R2,#xx ;access SCON LD R1, #xx ;access RXBUF LD RP, #00h ;Select ERF Bank 0 so I/O ports ;are again accessible. Table 7. Z8 Expanded Register File Bank Layout Expanded Register File Bank ERF Address Space Fh PCON, SMR, WDT, (00h, 0Bh, 0Fh), Working Register Group 0 only implemented. Eh Not implemented (reserved) Dh Not implemented (reserved) Ch SPI Registers: SCOMP, RXBUF, SCON (00h, 01h, 02h), Working Register Group 0 only implemented. Bh Not implemented (reserved) Ah Not implemented (reserved) 9h Not implemented (reserved) 8h Not implemented (reserved) 7h Not implemented (reserved) 6h Not implemented (reserved) 5h Not implemented (reserved) UM001602-0904 Z8 CPU User Manual 21 Table 7. Z8 Expanded Register File Bank Layout Expanded Register File Bank ERF 4h Not implemented (reserved) 3h Not implemented (reserved) 2h Not implemented (reserved) 1h Not implemented (reserved) 0h Z8 Ports 0, 1, 2, 3, and General-Purpose Registers 04h to EFh, and control registers F0h to FFh. Please refer to the specific product specification to determine the above registers are implemented. Z8 Control and Peripheral Registers Standard Z8 Registers The standard Z8 control registers govern the operation of the CPU. Any instruction which references the register file can access these control registers. Available control registers are: • • • • • • • UM001602-0904 Interrupt Priority Register (IPR) Interrupt Mask Register (IMR) Interrupt Request Register (IRQ) Program Control Flags (FLAGS) Register Pointer (RP) Stack Pointer High-Byte (SPH) Stack Pointer Low-Byte (SPL) Address Space Z8 Family of Microcontrollers User Manual 22 The Z8® CPU uses a 16-bit Program Counter (PC) to determine the sequence of current program instructions. The PC is not an addressable register. Peripheral registers are used to transfer data, configure the operating mode, and control the operation of the on-chip peripherals. Any instruction that references the register file can access the peripheral registers. The peripheral registers are: • • • • • • • • • Serial I/O (SIO) Timer Mode (TMR) Timer/Counter 0 (T0) T0 Prescaler (PRE0) Timer/Counter 1 (T1) T1 Prescaler (PRE1) Port 0–1 Mode (P01M) Port 2 Mode (P2M) Port 3 Mode (P3M) In addition, the four port registers (P0–P3) are considered to be peripheral registers. Expanded Z8 Registers The expanded Z8 control registers govern the operation of additional features or peripherals. Any instruction which references the register file can access these registers. The ERF contains the control registers for WDT, Port Control, Serial Peripheral Interface (SPI), and the SMR functions. Figure 6 on page 15 shows the layout of the Register Banks in the ERF. Register Bank C in the ERF consists of the registers for the SPI. Table 8 shows the registers within ERF Bank C, Working Register Group 0. Address Space UM001602-0904 Z8 CPU User Manual 23 Table 8. Expanded Register File Register Bank C WR Group 0 UM001602-0904 Register Function Working Register F Reserved R15 E Reserved R14 D Reserved R13 C Reserved R12 B Reserved R11 A Reserved R10 9 Reserved R9 8 Reserved R8 7 Reserved R7 6 Reserved R6 5 Reserved R5 4 Reserved R4 3 Reserved R3 2 SPI Control (SCON) R2 1 SPI Tx/Rx Data (Roxburgh) R1 0 SPI Compare (SCOMP) R0 Address Space Z8 Family of Microcontrollers User Manual 24 Working Register Group 0 in ERF Bank 0 consists of the registers for Z8 General-Purpose Registers and ports. Table 9 shows the registers within this group. Table 9. Expanded Register File Bank 0 WR Group 0 Address Space Register Function Working Register F General-Purpose Register R15 E General-Purpose Register R14 D General-Purpose Register R13 C General-Purpose Register R12 B General-Purpose Register R11 A General-Purpose Register R10 9 General-Purpose Register R9 8 General-Purpose Register R8 7 General-Purpose Register R7 6 General-Purpose Register R6 5 General-Purpose Register R5 4 General-Purpose Register R4 3 Port 3 R3 2 Port 2 R2 1 Port 1 R1 0 Port 0 R0 UM001602-0904 Z8 CPU User Manual 25 Working Register Group 0 in ERF Bank F consists of the control registers for STOP mode, WDT, and port control. Table 10 shows the registers within this group. Table 10. Expanded Register File Bank F WR Group 0 UM001602-0904 Register Function Working Register F WDTMR R15 E Reserved R14 D Reserved R13 C Reserved R12 B SMR R11 A Reserved R10 9 Reserved R9 8 Reserved R8 7 Reserved R7 6 Reserved R6 5 Reserved R5 4 Reserved R4 3 Reserved R3 2 Reserved R2 1 Reserved R1 0 PCON R0 Address Space Z8 Family of Microcontrollers User Manual 26 The functions and applications of the control and peripheral registers are described in subsequent sections of this manual. Program Memory The first 12 bytes of program memory are reserved for the interrupt vectors, as shown in Figure 8. These locations contain six 16-bit vectors that correspond to the six available interrupts. Address 12 up to the maximum ROM address consists of on-chip mask-programmable ROM. See the product data sheet for the exact program, data, register memory size, and address range available. At addresses outside the internal ROM, the Z8® CPU executes external program memory fetches through Port 0 and Port 1 in Address/Data mode for devices with Port 0 and Port 1 featured. Otherwise, the program counter will continue to execute NOPs up to address FFFFh, roll over to 0000h, and continue to fetch executable code (see Figure 8). The internal program memory is one-time programmable (OTP) or mask programmable dependent on the specific device. A ROM protect feature prevents dumping of the ROM contents by inhibiting execution of the LDC, LDCI, LDE, and LDEI instructions to program memory in all modes. ROM look-up tables cannot be used with this feature. The ROM Protect option is mask-programmable, to be selected by the customer when the ROM code is submitted. For the OTP ROM, the ROM Protect option is an OTP programming option. Address Space UM001602-0904 Z8 CPU User Manual 27 65535 External ROM and RAM 4096 4095 Location of First Byte of Instruction Executed After RESET On–Chip ROM 12 Interrupt Vector (Lower Byte) Interrupt Vector (Upper Byte) 11 IRQ5 10 IRQ5 9 IRQ4 8 IRQ4 7 IRQ3 6 IRQ3 5 IRQ2 4 IRQ2 3 IRQ1 2 IRQ1 1 IRQ0 0 IRQ0 Figure 8. Z8 Program Memory Map Z8 External Memory The Z8® CPU, in some cases, has the capability to access external program memory with the 16-bit Program Counter. To access external pro- UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 28 gram memory the Z8® CPU offers multiplexed address/data lines (AD7– AD0) on Port 1 and address lines (A15–A8) on Port 0. This feature only applies to devices that offer Port 0 and Port 1. The maximum external address is FFFF. This memory interface is supported by the control lines AS (Address Strobe), DS (Data Strobe), and R/W (Read/Write). The origin of the external program memory starts after the last address of the internal ROM. Figure 9 shows an example of external program memory for the Z8® CPU. External Data Memory The Z8® CPU, in some cases, can address up to 60 KB of external data memory beginning at location 4096. External data memory (DM) can be included with, or separated from, the external program memory space. DM, an optional I/O function that can be programmed to appear on pin P34, is used to distinguish between data and program memory space. The state of the DM signal is controlled by the type of instruction being executed. An LDC opcode references program memory (DM inactive) , and an LDE instruction references data memory (DM active Low) . The user must configure Port 3 Mode Register (P3M) bits D3 and D4 for this mode. Address Space UM001602-0904 Z8 CPU User Manual 29 65535 External Memory 4096 4095 Not Addressable 0 *Note: For additional information on using external memory, see Chapter 10 of this manual. For exact memory addressing options available, see the device product specification. Figure 9. External Memory Map UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 30 Z8 Stacks Stack operations can occur in either the Z8® Standard Register File or external data memory. Under software control, Port 0–1 Mode register (F8h) selects the stack location. Only the General-Purpose Registers can be used for the stack when the internal stack is selected. The register pair FEh and FFh form the 16-bit Stack Pointer (SP), that is used for all stack operations. The stack address is stored with the MSB in FEh and LSB in FFh; see Figure 10. FFh LOWER Byte Stack Pointer Low UPPER Byte Stack Pointer High FEh Figure 10. Stack Pointer The stack address is decremented prior to a PUSH operation and incremented after a POP operation. The stack address always points to the data stored on the top of the stack. The Z8® CPU stack is a return stack for CALL instructions and interrupts, as well as a data stack. During a CALL instruction, the contents of the PC are saved on the stack. The PC is restored during a RETURN instruction. Interrupts cause the contents of the PC and Flag registers to be saved on the stack. The IRET instruction restores them Figure 11. When the Z8® CPU is configured for an internal stack (using the Z8® Standard Register File), register FFh serves as the Stack Pointer. The Address Space UM001602-0904 Z8 CPU User Manual 31 value in FEh is ignored. FEh can be used as a general-purpose register in this case only. An overflow or underflow can occur when the stack address is incremented or decremented during normal stack operations. The programmer must prevent this occurrence or unpredictable operation will result. PCL PCH PCL Top of Stack PCH Top of Stack Stack Contents After a Call Instruction FLAGS Stack Contents After an Interrupt Cycle Figure 11. Stack Operations UM001602-0904 Address Space Z8 Family of Microcontrollers User Manual 32 Address Space UM001602-0904 Z8 CPU User Manual 33 Clock The Z8® CPU derives its timing from on-board clock circuitry connected to pins XTAL1 and XTAL2. The clock circuitry consists of an oscillator, a divide-by-two shaping circuit, and a clock buffer. Figure 12 illustrates the clock circuitry. The oscillator’s input is XTAL1 and its output is XTAL2. The clock can be driven by a crystal, a ceramic resonator, LC clock, RC, or an external clock source. Frequency Control In some cases, the Z8® CPU has an EPROM/OTP option or a Mask ROM option bit to bypass the divide-by-two flip flop in Figure 12. This feature is used in conjunction with the low EMI option. When low EMI is selected, the device output drive and oscillator drive is reduced to approximately 25 percent of the standard drive and the divide-by-two flip flop is bypassed such that the XTAL clock frequency is equal to the internal system clock frequency. In this mode, the maximum frequency of the XTAL clock is 4 MHz. Please refer to specific product specification for availability of options and output drive characteristics. XTAL1 XTAL2 OSC ÷2 Internal Clock Buffer Figure 12. Z8® CPU Clock Circuit Clock Control In some cases, the Z8® CPU offers software control of the internal system clock via programming register bits. The bits are located in the StopMode Recovery Register in Expanded Register File Bank F, Register 0Bh. UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 34 This register selects the clock divide value and determines the mode of Stop-Mode Recovery (see Figure 13). Please refer to the specific product specification for availability of this feature/register. SMR (F) OB D7 D6 D5 D4 D3 D2 D1 D0 SCLK ÷ TCLK Divide by 16 0 OFF ** 1 ON External Clock Divide Mode by 2 0 = SCLK ÷ TCLK = XTAL ÷ 2* 1 = SCLK ÷ TCLK = XTAL * Default setting after RESET. **Default setting after RESET and Stop-Mode Recovery. Figure 13. Stop-Mode Recovery Register (Write-Only Except D7, Which is Read-Only) SCLK ÷ TCLK Divide-By-16 Select The D0 bit of the SMR controls a divide-by-16 prescaler of SCLK ÷ TCLK. The purpose of this control is to selectively reduce device power consumption during normal processor execution (SCLK control) and/or HALT mode (where TCLK sources counter/timers and interrupt logic). External Clock Divide-By-Two The D1 bit can eliminate the oscillator divide-by-two circuitry. When this bit is 0, SCLK (System Clock) and TCLK (Timer Clock) are equal to the external clock frequency divided by two. The SCLK ÷ TCLK is equal to the external clock frequency when this bit is set (D1 = 1). Using this bit, together with D7 of PCON, further helps lower EMI (D7 (PCON) = 0, D1 (SMR) = 1). The default setting is 0. Maximum frequency is 4 MHz with D1 = 1 (see Figure 14). Clock UM001602-0904 Z8 CPU User Manual 35 OSC D1 (SMR) ÷2 D0 (SMR) ÷16 External Clock Figure 14. External Clock Circuit Oscillator Control In some cases, the Z8® CPU offers software control of the oscillator to select low EMI drive or standard drive. The selection is done by programming bit D7 of the Port Configuration (PCON) register (see Figure 15). The PCON register is located in Expanded Register File Bank F, Register 00h. UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 36 A 1 in bit D7 configures the oscillator with standard drive, while a 0 configures the oscillator with Low EMI drive. This only affects the drive capability of the oscillator and does not affect the relationship of the XTAL clock frequency to the internal system clock (SCLK). PCON (Fh) 00h D7 D6 D5 D4 D3 D2 D1 D0 Low EMI Oscillator 0 Low EMI 1 Standard Figure 15. Port Configuration Register (Write-Only) Oscillator Operation The Z8® CPU uses a Pierce oscillator with an internal feedback (see Figure 16). The advantages of this circuit are low cost, large output signal, low-power level in the crystal, stability with respect to VCC and temperature, and low impedances (not disturbed by stray affects). One drawback is the requirement for high gain in the amplifier to compensate for feedback path losses. The oscillator amplifies its own noise at start-up until it settles at the frequency that satisfies the gain/phase requirements A x B = 1, where A = V0/VI is the gain of the amplifier and B = VI/V0 is the gain of the feedback element. The total phase shift around the loop is forced to zero (360 degrees). Because VIN must be in phase with itself, the amplifier/inverter provides 180 degree phase shift and the feedback element is forced to provide the other 180 degrees of phase shift. R1 is a resistive component placed from output to input of the amplifier. The purpose of this feedback is to bias the amplifier in its linear region and to provide the start-up transition. Clock UM001602-0904 Z8 CPU User Manual 37 Capacitor C2 combined with the amplifier output resistance provides a small phase shift. It will also provide some attenuation of overtones. Capacitor C1 combined with the crystal resistance provides additional phase shift. C1 and C2 can affect the start-up time if they increase dramatically in size. As C1 and C2 increase, the start-up time increases until the oscillator reaches a point where it does not start up any more. For fast and reliable oscillator start-up over the manufacturing process range, ZiLOG recommends that the load capacitors be sized as low as possible without resulting in overtone operation. Z8 CPU VSS A RI V1 XTAL1 V0 XTAL2 C1 C2 Figure 16. Pierce Oscillator with Internal Feedback Circuit Layout Traces connecting crystal, caps, and the Z8® CPU oscillator pins should be as short and wide as possible. This reduces parasitic inductance and resistance. The components (caps, crystal, resistors) should be placed as close as possible to the oscillator pins of the Z8® CPU . The traces from the oscillator pins of the IC and the ground side of the lead caps should be guarded from all other traces (clock, VCC, address/ UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 38 data lines, system ground) to reduce cross talk and noise injection. This is usually accomplished by keeping other traces and system ground trace planes away from the oscillator circuit and by placing a Z8® CPU device VSS ground ring around the traces/components. The ground side of the oscillator lead caps should be connected to a single trace to the Z8® CPU’s VSS (GND) pin. It should not be shared with any other system ground trace or components except at the Z8® CPU’s VSS pin. This is to prevent differential system ground noise injection into the oscillator (see Figure 17). Indications of an Unreliable Design Start-up time and output level are two major indicators that are used in working designs to determine their reliability over full lot and temperature variations. These two indicators are described below. Start-Up Time. If start-up time is excessive, or varies widely from unit to unit, there is probably a gain problem. C1/C2 must be reduced; the amplifier gain is not adequate at frequency, or crystal resistance is too large. Output Level. The signal at the amplifier output should swing from ground to VCC. This indicates there is adequate gain in the amplifier. As the oscillator starts up, the signal amplitude grows until clipping occurs, at which point the loop gain is effectively reduced to unity and constant oscillation is achieved. A signal of less than 2.5 volts peak-to-peak is an indication that low gain may be a problem. Either C1 or C2 should be made smaller or a low-resistance crystal should be used. Circuit Board Design Rules The following circuit board design rules are suggested: • Clock To prevent induced noise the crystal and load capacitors should be physically located as close to the Z8® CPU as possible. UM001602-0904 Z8 CPU User Manual 39 UM001602-0904 • Signal lines should not run parallel to the clock oscillator inputs. In particular, the crystal input circuitry and the internal system clock output should be separated as much as possible. • VCC power lines should be separated from the clock oscillator input circuitry. • Resistivity between XTAL1 or XTAL2 and the other pins should be greater than 10 MΩ. Clock Z8 Family of Microcontrollers User Manual 40 XTAL1 20 mm max C1 Signal Line Layout Should Avoid High Lighted Areas Z8 CPU XTAL2 C2 VSS Clock Generator Circuit 1 2 Signals A B 3 (Parallel Traces Must Be Avoided) Z8 CPU VSS Signal C 2 Z8 CPU Board Design Example (Top View) 3 (Connection to System Group Must Be Avoided) Figure 17. Circuit Board Design Rules Crystals and Resonators Crystals and ceramic resonators, shown in Figure 18 should have the characteristics listed in Table 11 to ensure proper oscillator operation. Clock UM001602-0904 Z8 CPU User Manual 41 Table 11. Crystal/Resonator Characteristics Crystal Cut: AT (crystal only) Mode: Parallel, Fundamental mode Crystal Capacitance: < 7 pF Load Capacitance: 10 pF < CL < 220 pF, 15 typical Resistance: 100 Ω max Depending on operation frequency, the oscillator may require the addition of capacitors C1 and C2 (shown in Figure 18). The capacitance values are dependent on the manufacturer’s crystal specifications. VSS Z8 CPU XTAL1 XTAL2 RF C1 RD C2 Figure 18. Crystal/Ceramic Resonator Oscillator UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 42 XTAL1 C1 L Z8 CPU VSS XTAL2 C2 Figure 19. LC Clock In most cases, the RD is 0 Ω and RF is infinite. It is determined and specified by the crystal/ceramic resonator manufacturer. The RD can be increased to decrease the amount of drive from the oscillator output to the crystal. It can also be used as an adjustment to avoid clipping of the oscillator signal to reduce noise. The RF can be used to improve the start-up of the crystal/ceramic resonator. The Z8® oscillator already has an internal shunt resistor in parallel to the crystal/ceramic resonator. XTAL1 Z8 CPU VSS XTAL2 Figure 20. External Clock Clock UM001602-0904 Z8 CPU User Manual 43 In Figures 18 through 20, ZiLOG recommends that the user connect the load capacitor ground trace directly to the VSS (GND) pin of the Z8® CPU to ensure that no system noise is injected into the Z8® clock. This trace should not be shared with any other components except at the VSS pin of the Z8® CPU. In some cases, the Z8® CPU’s XTAL1 pin also functions as one of the EPROM high-voltage mode programming pins or as a special factory test pin. In this case, applying 2 V above VCC on the XTAL1 pin will cause the device to enter one of these modes. Because this pin accepts high voltages to enter these respective modes, the standard input protection diode to VCC is not on XTAL1. ZiLOG recommends that in applications where the Z8® CPU is exposed to much system noise, a diode from XTAL1 to VCC be used to prevent accidental enabling of these modes. This diode will not affect the crystal/ceramic resonator operation. Please note that a parallel resonant crystal or resonator data sheet will specify a load capacitor value that is the series combination of C1 and C2, including all parasitics (PCB and holder). LC Oscillator The Z8® CPU oscillator can use a LC network to generate a XTAL clock (see Figure 19). The frequency stays stable over VCC and temperature. The oscillation frequency is determined by the equation. Frequency = 1 2 π (LCT)1/2 where L is the total inductance including parasitics and CT is the total series capacitance including the parasitics. Simple series capacitance is calculated using the following equation: UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 44 1 CT If C1 = 1 C1 + 1 C2 = C2 1 = 2 CT = C1 C1 = 2CT Sample calculation of capacitance C1 and C2 for 5.83 MHz frequency and inductance value of 27 µH. 5.83 (106) = 1 2π [2.7 (10–6) CT] 1/2 CT = 27.6 pF Thus C1 = 55.2 pF and C2 = 55.2 pF. RC Oscillator In some cases, the Z8® CPU features an RC oscillator option. Please refer to the specific product specification for availability. The RC oscillator requires a resistor across XTAL1 and XTAL2. An additional load capacitor is required from the XTAL1 input to VSS pin (see Figure 21). Clock UM001602-0904 Z8 CPU User Manual 45 XTAL1 R Z8 CPU VSS XTAL2 C1 Figure 21. RC Clock UM001602-0904 Clock Z8 Family of Microcontrollers User Manual 46 Clock UM001602-0904 Z8 CPU User Manual 47 Reset This section describes the Z8® CPU reset conditions, reset timing, and register initialization procedures. Reset is generated by Power-On Reset (POR), Reset Pin, Watch–Dog Timer (WDT), and Stop-Mode Recovery. A system reset overrides all other operating conditions and puts the Z8® CPU into a known state. To initialize the chip’s internal logic, the RESET input must be held Low for at least 21 SCP or 5 XTAL clock cycles. The control register and ports are reset to their default conditions after a POR, a reset from the RESET pin, or Watch–Dog Timer time-out while in RUN mode and HALT mode. The control registers and ports are not reset to their default conditions after Stop- Mode Recovery and WDT time-out while in STOP mode. While RESET pin is Low, AS is output at the internal clock rate, DS is forced Low, and R/W remains High. The program counter is loaded with 000Ch. I/O ports and control registers are configured to their default reset state. Resetting the Z8® CPU does not affect the contents of the general-purpose registers. Reset Pin, Internal POR Operation In some cases, the Z8® CPU hardware RESET pin initializes the control and peripheral registers, as shown in Tables 12 through 15. Specific reset values are shown by 1 or 0, while bits whose states are unknown are indicated by the letter U. Tables 12 through 15 show the reset conditions for the Z8 CPU. Note: The register file reset state is device dependent. Please refer to the selected device product specifications for register availability and reset state. UM001602-0904 Reset Z8 Family of Microcontrollers User Manual 48 Table 12. Sample Control and Peripheral Register Reset Values (ERF Bank 0) Bits Register (Hex) Register Name 7 6 5 4 3 2 1 0 Comments F0 Serial I/O U U U U U U U U F1 Timer Mode 0 0 0 0 0 0 0 0 Counter/Timers stopped. F2 Counter/Timer1 U U U U U U U U F3 T1 Prescaler U U U U U U 0 0 Single-pass count mode, external clock source. F4 Counter/Timer0 U U U U U U U U F5 T0 Prescaler U U U U U U U 0 Single-pass count mode. F6 Port 2 Mode 1 1 1 1 1 1 1 1 All inputs. F7 Port 3 Mode 0 0 0 0 0 0 0 0 Port 2 open-drain, P33– P30 Input, P37–P34 Output. F8 Port 0–1 Mode 0 1 0 0 1 1 0 1 Internal Stack, Normal Memory Timing. F9 Interrupt Priority U U U U U U U U FA Interrupt Request 0 0 0 0 0 0 0 0 All Interrupts Cleared. FB Interrupt Mask 0 U U U U U U U Interrupts Disabled. FC Flags U U U U U U U U FD Register Pointer 0 0 0 0 0 0 0 0 FE Stack Pointer (High) U U U U U U U U FF Stack Pointer (Low) U U U U U U U U Reset UM001602-0904 Z8 CPU User Manual 49 Program execution starts 5 to 10 clock cycles after internal RESET has returned High. The initial instruction fetch is from location 000Ch. Figure 22 illustrates reset timing. First Machine Cycle T1 Clock SCLK RESET Hold Low For 4 SCLK Periods (Minimum) AS DS R/W First Instruction Fetch Figure 22. Reset Timing After a reset, the first routine executed should be one that initializes the control registers to the required system configuration. The RESET pin is the input of a Schmitt-triggered circuit. Resetting the Z8® CPU will initialize port and control registers to their default states. To form the internal reset line, the output of the trigger is synchronized with the internal clock. The clock must therefore be running for RESET to function. It requires 4 internal system clocks after reset is detected for the Z8® CPU to reset the internal circuitry. An internal pull-up, combined with an external capacitor of 1 uf, provides enough time to properly reset the Z8® CPU (see Figure 23). In some cases, the Z8® CPU has an internal POR timer circuit that holds the Z8® CPU in reset mode for a duration UM001602-0904 Reset Z8 Family of Microcontrollers User Manual 50 (TPOR) before releasing the device out of reset. On these Z8 devices, the internally generated reset drives the reset pin low for the POR time. Any devices driving the reset line must be open-drained in order to avoid damage from possible conflict during reset conditions. This reset time allows the on-board clock oscillator to stabilize. To avoid asynchronous and noisy reset problems, the Z8® CPU is equipped with a reset filter of four external clocks (4TpC). If the external reset signal is less than 4TpC in duration, no reset occurs. On the fifth clock after the reset is detected, an internal RST signal is latched and held for an internal register count of 18 external clocks, or for the duration of the external reset, whichever is longer. During the reset cycle, DS is held active low while AS cycles at a rate of the internal system clock. Program execution begins at location 000Ch, 5-10 TpC cycles after RESET is released. For the internal Power-On Reset, the reset output time is specified as TPOR. Please refer to specific product specifications for actual values. +5V RESET 1K 100 KΩ to 200 KΩ 1 µF 10 V Figure 23. Example of External Power-On Reset Circuit Reset UM001602-0904 Z8 CPU User Manual 51 Table 13. Expanded Register File Bank 0 Reset Values at RESET Bits Register (Hex) Register Name 7 6 5 4 3 2 1 0 Comments 00 Port 0 U U U U U U U U Input mode, output set to push–pull. 01 Port 1 U U U U U U U U Input mode, output set to push–pull. 02 Port 2 U U U U U U U U Input mode, output set to open drain. 03 Port 3 1 1 1 1 U U U U Standard digital input and output Z86L7X Family Device Port P34-P37 = 0 (Except Z86L70/71/75) All other Z8 = 1. 04–EF General-Purpose Registers 04h– EFh U U U U U U U U Undefined. Table 14. Sample Expanded Register File Bank C Reset Values Bits Register (Hex) Register Name 7 6 5 4 3 2 1 0 Comments 00 SPI Compare (SCOMP) 0 0 0 0 0 0 0 0 01 Receive Buffer (RxBUF) U U U U U U U U 02 SPI Control (SCON) U U U U 0 0 0 0 UM001602-0904 Reset Z8 Family of Microcontrollers User Manual 52 Table 15. Sample Expanded Register File Bank F Reset Values Bits Register (Hex) Register Name 7 6 5 4 3 2 1 0 Comments 00 1 1 1 1 1 1 1 0 Comparator outputs disabled on Port 3. Port Configuration (PCON) Port 0 and 1 output is push–pull. Port 0, 1, 2, 3, and oscillator with standard output drive. 0B Stop-Mode Recovery (SMR) 0 0 1 0 0 0 0 0 Clock divide by 16 off. XTAL divide by 2. POR and/OR External Reset. Stop delay on. Stop recovery level is low, STOP flag is POR. 0F Reset Watch–Dog Timer Mode (WDTMR) U U U 0 1 1 0 1 512 TPC for WDT time out, WDT runs during STOP. UM001602-0904 Z8 CPU User Manual 53 RESET 4 Clock Filter Clear CLK 18 Clock RESET Generator RESET Internal RESET WDT Select (WDTMR) WDT TAP SELECT CLK Source Select (WDTMR) XTAL RC OSC. VDD 2.6V REF + - M U X 256 TpC POR CK CLR 256 TpC 512 TpC 1024 TpC 4096 TpC WDT/POR Counter Chain 2.6V Operating Voltage Det. WDT . From Stop Mode Recovery Source Stop Delay Select (SMR) Figure 24. Example of Z8 Reset with RESET Pin, WDT, SMR, and POR UM001602-0904 Reset Z8 Family of Microcontrollers User Manual 54 CLEAR 18 Clock RESET CLK Generator 4 Clock Filter RESET Internal RESET WDT Select (WDTMR) WDT TAP SELECT CLK Source Select (WDTMR) XTAL Internal RC OSC. VDD + - VLV M U X 5ms POR CLK CLR 5ms 15ms 25ms 100ms WDT/POR Counter Chain 2V Operating Voltage Det. WDT . From Stop Mode Recovery Source Stop Delay Select (SMR) Figure 25. Example of Z8 Reset with WDT, SMR, and POR Reset UM001602-0904 Z8 CPU User Manual 55 Watch–Dog Timer The Watch-Dog Timer (WDT) is a retriggerable one-shot timer that resets the Z8® CPU if it reaches its terminal count. When operating in the RUN or HALT modes, a WDT reset is functionally equivalent to a hardware POR reset. The WDT is initially enabled by executing the WDT instruction and refreshed on subsequent executions of the WDT instruction. The WDT cannot be disabled after it has been initially enabled. Permanently enabled WDTs are always enabled and the WDT instruction is used to refresh it. The WDT circuit is driven by an on-board RC oscillator or external oscillator from the XTAL1 pin. The POR clock source is selected with bit 4 of the Watch–Dog Timer Mode register (WDTMR). In some cases, a Z8 that offers the WDT but does not have a WDTMR register, has a fixed WDT time-out and uses the on board RC oscillator as the only clock source. Please refer to specific product specifications for selectability of time-out, WDT during HALT and STOP modes, source of WDT clock, and availability of the permanently-on WDT option. Execution of the WDT instruction affects the Z (zero), S (sign), and V (overflow) flags. UM001602-0904 Watch–Dog Timer Z8 Family of Microcontrollers User Manual 56 WDTMR (F) 0F D7 D6 D5 D4 D3 D2 D1 D0 WDT TAP* 00 01** 10 11 INT RC OSC 5 10 20 80 SYS CLK 128 256 512 2048 WDT During HALT 0 OFF 1 ON * WDT During STOP 0 OFF 1 ON * XTAL1/INT RC Select for WDT 0 On-Board RC * 1 XTAL Reserved (Must be 0) * Must be 0 for Z86C03 ** Default setting after RESET Figure 26. Example of Z8 Watch–Dog Timer Mode Register (WriteOnly) The WDTMR register is accessible only during the first 60 processor cycles from the execution of the first instruction after Power-On Reset, Watch–Dog Reset or a Stop-Mode Recovery. After this point, the register cannot be modified by any means, intentional or otherwise. The WDTMR is a write-only register. WDTMR is located in Expanded Register File Bank F, register 0Fh. This register’s control bits are described on the next two pages. Watch–Dog Timer UM001602-0904 Z8 CPU User Manual 57 WDT Time Select. Bits D1 and D0 control a tap circuit that determines the time-out period. Table 16 shows the different values that can be obtained. The default value of D1 and D0 are 0 and 1, respectively. Table 16. Time-Out Period of the WDT Time-Out of Typical Time-Out of Internal RC OSC System Clock 0 5 ms min 256 TpC 0 1 15 ms min 512 TpC 1 0 25 ms min 1024 TpC 1 1 100 ms min 4096 TpC D1 D0 0 *Notes: The values given are for VCC = 5.0V. See the device product specification for exact WDTMR time out select options available. 1. TpC = XTAL clock cycle 2. The default on reset is, D0 = 1 and D1 = 0. WDT During HALT. The D2 bit determines whether or not the WDT is active during HALT mode. A 1 indicates active during HALT. The default is 1. A WDT time out during HALT mode will reset control register ports to their default reset conditions. WDT During STOP. The D3 bit determines whether or not the WDT is active during STOP mode. Because XTAL clock is stopped during STOP mode, unless as specified below, the on-board RC must be selected as the clock source to the POR counter. A 1 indicates active during STOP. The default is 1. If bits D3 and D4 are both set to 1, the WDT only, is driven by the external clock during STOP mode. This feature makes it possible to wake up from STOP mode from an internal source. Please refer to specific product specifications for conditions of control and port registers when the Z8® CPU comes out of STOP mode. A WDT time out during STOP mode will not reset all control registers. The reset conditions of the ports from STOP mode due to WDT time out is the same as if recovered using any of the other STOP mode sources. UM001602-0904 Watch–Dog Timer Z8 Family of Microcontrollers User Manual 58 Clock Source for WDT. The D4 bit determines which oscillator source is used to clock the internal POR and WDT counter chain. If the bit is a 1, the internal RC oscillator is bypassed and the POR and WDT clock source is driven from the external pin, XTAL1. The default configuration of this bit is 0, which selects the internal RC oscillator. Bits 5, 6, and 7. These bits are reserved. VCC Voltage Comparator. An on-board voltage comparator checks that VCC is at the required level to insure correct operation of the device. Reset is globally driven if VCC is below the specified voltage. This feature is available in select ROM Z8 devices. See the device product specification for feature availability and operating range. Power-On-Reset A timer circuit clocked by a dedicated on-board RC oscillator is used for the Power-On Reset (POR) timer function, TPOR. This POR time allows VCC and the oscillator circuit to stabilize before instruction execution begins. The POR timer circuit is a one-shot timer triggered by one of three conditions: • • • Power fail to Power OK status (cold start) Stop-Mode Recovery (if bit 5 of SMR = 1) WDT time-out The POR time is specified as TPOR. On Z8 devices that feature a StopMode Recovery register (SMR), bit 5 selects whether the POR timer is used after Stop-Mode Recovery or by-passed. If bit D5 = 1 then the POR timer is used. If bit 5 = 0 then the POR timer is by-passed. In this case, the Stop-Mode Recovery source must be held in the recovery state for 5 TPC or 5 crystal clocks to pass the reset signal internally. This option is used Watch–Dog Timer UM001602-0904 Z8 CPU User Manual 59 when the clock is provided with an RC/LC clock. See the device product specification for timing details. POR (cold start) will always reset the Z8® CPU control and port registers to their default condition. If a Z8 has a SMR register, the warm start bit will be reset to a 0 to indicate POR. INT OSC XTAL OSC POR (Cold Start) VBO Delay Line TPOR ms WDT 18 CLK Reset Filter Chip Reset P27 (Stop Mode) Figure 27. Example of Z8 with Simple SMR and POR UM001602-0904 Watch–Dog Timer Z8 Family of Microcontrollers User Manual 60 Watch–Dog Timer UM001602-0904 Z8 CPU User Manual 61 I/O Ports The Z8® CPU features up to 32 lines dedicated to input and output. These lines are grouped into four 8-bit ports known as Port 0, Port 1, Port 2, and Port 3. Port 0 is nibble programmable as input, output, or address. Port 1 is byte configurable as input, output, or address/data. Port 2 is bit programmable as either inputs or outputs, with or without handshake and SPI. Port 3 can be programmed to provide timing, serial and parallel input/output, or comparator input/output. All ports have push–pull CMOS outputs. In addition, the push–pull outputs of Port 2 can be turned off for open-drain operation. Mode Registers Each port has an associated Mode Register that determines the port’s functions and allows dynamic change in port functions during program execution. Port and Mode Registers are mapped into the Standard Register File as shown in Figure 28. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 62 Register HEX Identifier Port 0–1 Mode F8h P01M Port 3 Mode F7h P3M Port 2 Mode F6h P2M Port 3 03h P3 Port 2 02h P2 Port 1 01h P1 Port 0 00h P0 Figure 28. I/O Ports and Mode Registers Because of their close association, Port and Mode registers are treated like any other general-purpose register. There are no special instructions for port manipulation. Any instruction which addresses a register can address the ports. Data can be directly accessed in the Port Register, with no extra moves. Input and Output Registers Each bit of Ports 0, 1, and 2, have an input register, an output register, associated buffer, and control logic. Because there are separate input and output registers associated with each port, writing to bits defined as inputs stores the data in the output register. This data cannot be read as long as the bits are defined as inputs. However, if the bits are reconfigured as outputs, the data stored in the output register is reflected on the output pins I/O Ports UM001602-0904 Z8 CPU User Manual 63 and can then be read. This mechanism allows the user to initialize the outputs prior to driving their loads (see Figure 29). Because port inputs are asynchronous to the Z8® CPU internal clock, a READ operation could occur during an input transition. In this case, the logic level might be uncertain (somewhere between a logic 1 and 0). To eliminate this meta-stable condition, the Z8® CPU latches the input data two clock periods prior to the execution of the current instruction. The input register uses these two clock periods to stabilize to a legitimate logic level before the instruction reads the data. Note: The following sections describe the generic function of the Z8® CPU ports. Any additional features of the ports such as SPI, C/T, and StopMode Recovery are covered in their own section. Port 0 This section deals with only the I/O operation of Port 0. The port's external memory interface operation is covered later in this manual. Figure 29 shows a block diagram of Port 0. This diagram also applies to Ports 1 and 2. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 64 Port I/O Lines 8 8 8 Input Buffer Input Register Read Port E Internal Timing 8 Handshake Selected DAV/RDY Handshake Handshake Logic Logic Write Port RDY/DAV 8 Output Register Output Buffer 8 8 Output Enable Internal Bus Figure 29. Ports 0, 1, 2 Generic Block Diagram I/O Ports UM001602-0904 Z8 CPU User Manual 65 General I/O Mode Port 0 can be an 8-bit, bidirectional, CMOS or TTL compatible I/O port. These eight I/O lines can be configured under software control as a nibble I/O port (P03–P00 input/output and P07–P04 input/output), or as an address port for interfacing external memory. The input buffers can be Schmitt-triggered, level shifted, or a single-trip point buffer and can be nibble programmed. Either nibble output can be globally programmed as push–pull or open-drain. Low EMI output buffers in some cases can be globally programmed by the software as an OTP program option or as a ROM mask option. In such cases, the Z8® MCU features autolatches that are hardwired to the inputs. Please refer to the specific Z8 MCU product specification for the exact input/output buffer features that are available (see Figures 30 and 31). UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 66 4 Port 1 (I/O or AD15–AD08) Z8 4 Handshake Controls DAV0 and RDY0 (P32 and P35) OPEN-DRAIN OEN PIN OUT 1.5 2.3V Hysteresis IN Autolatch R ≈ 500 KΩ Figure 30. Port 0 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger I/O Ports UM001602-0904 Z8 CPU User Manual 67 OEN PIN OUT TTL Level Shifter IN Figure 31. Port 0 Configuration with TTL Level Shifter Read/Write Operations In the nibble I/0 Mode, Port 0 is accessed as general-purpose register P0 (00h) with ERF Bank set to 0. The port is written by specifying P0 as an instruction's destination register. Writing to the port causes data to be stored in the port's output register. The port is read by specifying P0 as the source register of an instruction. When an output nibble is read, data on the external pins is returned. Under normal loading conditions this is equivalent to reading the output register. However, for Port 0 outputs defined as open–drain, the data returned is the value forced on the output by the external system. This may not be the same as the data in the output register. Reading a nibble defined as input also returns data on the external pins. However, input bits UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 68 under handshake control return data latched into the input register via the input strobe. The Port 0–1 Mode resistor bits D1–D0 and D7–D6 are used to configure Port 0 nibbles. The lower nibble (P00–P03) can be defined as inputs by setting bits D1 to 0 and D0 to 1, or as outputs by setting both D1 and D0 to 0. Likewise, the upper nibble (P04–P07) can be defined as inputs by setting bits D7 to 0 and D6 to 1, or as outputs by setting both D6 and D7 to 0 (see Figure 32). Handshake Operation When used as an I/0 port, Port 0 can be placed under handshake control by programming the Port 3 Mode register bit D2 to 1. In this configuration, handshake control lines are DAV0 (P32) and RDY0 (P35) when Port 0 is an input port, or RDY0 (P32) and DAV0 (P35) when Port 0 is an output port (see Figure 33). Handshake direction is determined by the configuration (input or output) assigned to the Port 0 upper nibble, P04–P07. The lower nibble must have the same I/0 configuration as the upper nibble to be under handshake control. Figure 30 illustrates the Port 0 upper and lower nibbles and the associated handshake lines of Port 3. Port 1 This section deals only with the I/0 operation. The port's external memory interface operation is discussed later in this manual. Figure 29 shows a block diagram of Port 1. General I/O Mode Port 1 can be an 8-bit, bidirectional, CMOS or TTL compatible port with multiplexed address (A7–A0) and data (D7–D0) ports. These eight I/O lines can be byte programmed as inputs or outputs or can be configured under software control as an Address/Data port for interfacing to external I/O Ports UM001602-0904 Z8 CPU User Manual 69 memory. The input buffers can be Schmitt-triggered, level- shifted, or a single-point buffer. In some cases, the output buffers can be globally programmed as either push–pull or open-drain. Low-EMI output buffers can be globally programmed by software, as an OTP program option, or as a ROM Mask Option. In some cases, the Z8® MCU can have autolatches hardwired to the inputs. Please refer to specific product specifications for exact input/output buffer-type features available (Figures 32 and 33). Register F8h (P01M) Port 0–1 Mode Register (P01M) (Write-Only) D7 D6 D1 D0 P04–P07 Mode 00 = Output 01 = Input 1X = A12–A15 P00–P03 Mode 00 = Output 01 = Input 1X = A8–A11 Figure 32. Port 0 I/O Operation Register F7h Port 3 Mode Register (P3M) (Write-Only) D2 0 P32 = Input P35 = Output 1 P32 = DAV0/RDY0 P35 = RDY0/DAV0 Figure 33. Port 0 Handshake Operation UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 70 8 Port 1 (I/O or AD7–AD0) Z8 Handshake Controls DAV1 and RDY1 (P33 and P34) OPEN-DRAIN OEN PIN OUT 1.5 2.3V Hysteresis IN Autolatch R ≈ 500 KΩ Figure 34. Port 1 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger I/O Ports UM001602-0904 Z8 CPU User Manual 71 8 Port 1 (I/O or AD7–AD0) Z8 Handshake Controls DAV1 and RDY1 (P33 and P34) OEN PIN OUT TTL Level Shifter IN Figure 35. Port 1 Configuration with TTL Level Shifter Read/Write Operations In byte input or byte output mode, the port is accessed as General-Purpose Register P1 (01h). The port is written by specifying P1 as an instruction's UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 72 destination register. Writing to the port causes data to be stored in the port's output register. The port is read by specifying P1 as the source register of an instruction. When an output is read, data on the external pins is returned. Under normal loading conditions, this is equivalent to reading the output register. However, if Port 1 outputs are defined as open-drain, the data returned is the value forced on the output by the external system. This may not be the same as the data in the output register. When Port 1 is defined as an input, reading also returns data on the external pins. However, inputs under handshake control return data latched into the input register via the input strobe. Using the Port 0–1 Mode Register, Port 1 is configured as an output port by setting bits D4 and D3 to 0, or as an input port by setting D4 to 0 and D3 to 1 (see Figure 36). R248 P01M Port 0–1 Mode Register (F8, Write-Only) D4 D3 P10–P13 Mode 00 = Byte Output 01 = Byte Output 10 = AD0-AD7 11 = High Impedance AD0–AD7, AS, DS, R/W, A8–A11, A12–A15 Figure 36. Port 1 I/O Operation I/O Ports UM001602-0904 Z8 CPU User Manual 73 Handshake Operations When used as an I/O port, Port 1 can be placed under handshake control by programming the Port 3 Mode register bits D4 and D3 both to 1. In this configuration, handshake control lines are DAV1 (P33) and RDY1 (P34) when Port 1 is an input port, or RDY1 (P33) and DAV1 (P34) when Port 1 is an output port. See Figures 37 and 39. Handshake direction is determined by the configuration (input and output) assigned to Port 1. For example, if Port 1 is an output port then handshake is defined as output. R247 P3M Port 3 Mode Register (F7, Write-Only) D4 D3 00 P33 = Input P34 = Output 01 P33 = Input P34 = DM 10 P33 = Input P34 = DM 11 P33 = DAV1/RDY1 P34 = RDY1/DAV1 Figure 37. Handshake Operation Port 2 Port 2 is a general-purpose port. Figure 29 shows a block diagram of Port 2. Each of its lines can be independently programmed as input or output via the Port 2 Mode Register (F6h) as seen in Figure 38. A bit set to a 1 in P2M configures the corresponding bit in Port 2 as an input, while a bit set to 0 configures an output line. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 74 Register F6h Port 2 Mode Register (P2M) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Port 2 Mode 0 = Output 1 = Input Figure 38. Port 2 I/O Mode Configuration General Port I/O Port 2 can be an 8-bit, bidirectional, CMOS- or TTL- compatible I/O port. These eight I/O lines can be configured under software control to be an input or output, independently. Input buffers can be Schmitt-triggered, level-shifted, or a single trip point buffer and may contain autolatches. Bits programmed as outputs may be globally programmed as either push– pull or open-drain. Low-EMI output buffers can be globally programmed by the software, an OTP program option, or as a ROM mask option. In addition, when the SPI is featured and enabled, P20 functions as data-in (DI), and P27 functions as data-out (DO). Please refer to specific product specifications for exact input/output buffer type features available. See Figures 39 through 41. I/O Ports UM001602-0904 Z8 CPU User Manual 75 OPEN-DRAIN P21–P26 OE P21–P26 PIN P21–P26 OUT 1.5 2.3V Hysteresis @ VCC = 5.0V P21–P26 IN Autolatch R ≈ 500 KΩ Figure 39. Port 2 Configuration with Open-Drain Capability, Autolatch, and Schmitt-Trigger UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 76 Open-Drain OEN PIN OUT TTL Level Shifter IN Figure 40. Port 2 Configuration with TTL Level Shifter I/O Ports UM001602-0904 Z8 CPU User Manual 77 OPEN-DRAIN P20 OE SPI EN P20 PIN P20 OUT P20 IN or SPI DI Autolatch R ≈ 500 KΩ OPEN-DRAIN Standard P27 OUT SPI SPI DO P27 PIN Standard P27 OE SPI SPI Active SCON D2 0 SOI D0 Enable 1 P27 OUT *SPI must be enabled with D0 P27 IN Autolatch R ≈ 500 KΩ Figure 41. Port 2 Configuration with Open-Drain Capability, Autolatch, Schmitt-Trigger and SPI UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 78 Read/Write Operations Port 2 is accessed as General-Purpose Register P2 (02h). Port 2 is written by specifying P2 as an instruction’s destination register. Writing to Port 2 causes data to be stored in the output register of Port 2, and reflected externally on any bit configured as an output. Port 2 is read by specifying P2 as the source register of an instruction. When an output bit is read, data on the external pin is returned. Under normal loading conditions, this is equivalent to reading the output register. However, if a bit of Port 2 is defined as an open-drain output, the data returned is the value forced on the output pin by the external system. This may not be the same as the data in the output register. Reading input bits of Port 2 also returns data on the external pins. However, inputs under handshake control return data latched into the input register via the input strobe. Handshake Operation Port 2 can be placed under handshake control by programming bit 6 in the Port 3 Mode Register (see Figure 42). In this configuration, Port 3 lines P31 and P36 are used as the handshake control lines DAV2 and RDY2 for input handshake, or RDY2 and DAV2 for output handshake. Handshake direction is determined by the configuration (input or output) assigned to bit 7 of Port 2. Only those bits with the same configuration as P27 will be under handshake control. Figure 43 illustrates the bit lines of Port 2 and the associated handshake lines of Port 3. I/O Ports UM001602-0904 Z8 CPU User Manual 79 Register F7h Port 3 Mode Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Port 2 Handshaking 0 P31 = Input (TIN) 1 P31 = DAV2/RDY2 P36 = Output (TOUT) P36 = RDY2/DAV2 Figure 42. Port 2 Handshake Configuration P20 Port 2 (I/O) P27 Handshake Controls DAV2 and RDY2 (P31 and P36) Figure 43. Port 2 Handshaking UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 80 Port 3 General Port I/O Port 3 differs structurally from Port 0, 1, and 2. Port 3 lines are fixed as four inputs (P33–P30) and four outputs (P37–P34) Port 3 does not have an input and output register for each bit. Instead, all of the input lines have one input register, and all of the output lines have an output register. Port 3 can be a CMOS- or TTL- compatible I/O port. Under software control, the lines can be configured as special control lines for handshake, comparator inputs, SPI control, external memory status, or I/O lines for the on-board serial and timer facilities. Figure 44 is a generic block diagram of Port 3. The inputs can be Schmitt-triggered, level-shifted, or single-trip point buffered. In some cases, the Z8® MCU may have autolatches hardwired on certain Port 3 inputs and Low-EMI capabilities on the outputs. Please refer to specific product specifications for exact input/output buffer type features. Please refer to the section on counter/timers, Stop-Mode Recovery, serial I/O, comparators, and interrupts for more information on the relationships of Port 3 to that feature. I/O Ports UM001602-0904 Z8 CPU User Manual 81 Read Port Input Register 4 Input Input Buffer Buffer 4 Port Input Lines P30–P33 4 To Interrupt Timer, Handshake Logic, or Serial I/O Read Port Output Data Return Buffer 4 4 Write Port 4 Internal Bus Output Output Register Register Register Output Output Buffer Buffer 4 4 Port Output Lines P34–P37 From Timer, Handshake Logic, or Serial I/O Figure 44. Port 3 Block Diagram UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 82 I/O Ports UM001602-0904 Z8 CPU User Manual 83 P30 P31 P32 P33 Port 3 (I/O or Control) Z8 P34 P35 P36 P37 Autolatch R ≈ 500 KΩ P30 Data Latch IRQ3 P30 R247 = P3M D1 1 = Analog 0 = Digital DIG. P31 (AN1) IRQ2, TIN, P31 Data Latch + - P32 (AN2) AN. IRQ0, P32 Data Latch + - P33 (REF) From Stop-Mode Recovery Source IRQ1, P33 Data Latch Figure 45. Port 3 Configuration with Comparator, Autolatch, and Schmitt-Trigger UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 84 P34 P37 OUT PIN P32 + REF (P33) P37 P37 OUT P32 PIN + REF (P33) PCON D0 0 P34, P37 Standard Output 1 P34, P37 Comparator Output Figure 46. Port 3 Configuration with Comparator I/O Ports UM001602-0904 Z8 CPU User Manual 85 UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 86 SK IN SPI EN SPI MSTR P34 PIN SPI EN SK OUT P34 OUT P31 MUX + SS REF SPI EN SPI MSTR P35 PIN P34 OUT P31 + - REF PCON D0 0 P34, P35 Standard Output 1 P34, P35 Comparator Output Figure 47. Port 3 Configuration with SPI and Comparator Outputs I/O Ports UM001602-0904 Z8 CPU User Manual 87 Port 3 Output Configuration PIN OUT TTL Level Shifter Port 3 Input Configuration IN PIN Autolatch R ≈ 500 KΩ Figure 48. Port 3 Configuration with TTL Level Shifter and Autolatch Read/Write Operations Port 3 is accessed as a General-Purpose Register P3 (03h). Port 3 is written by specifying P3 as an instruction’s destination register. However, Port 3 outputs cannot be written to if they are used for special functions. When writing to Port 3, data is stored in the output register. Port 3 is read by specifying P3 as the source register of an instruction. When reading from Port 3, the data returned is both the data on the input pins and in the output register. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 88 Special Functions Special functions for Port 3 are defined by programming the Port 3 Mode Register. By writing 0s in bit 6 through bit 1, lines P37–P30 are configured as input/output pairs (see Figure 49). Table 17 shows available functions for Port 3. The special functions indicated in the figure are discussed in detail in their corresponding sections in this manual. Port 3 input lines P33–P30 always function as interrupt requests regardless of the configuration specified in the Port 3 Mode Register. Register F7h Port 3 Mode Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 0 Port 2 Open-Drain 1 Port 2 Push–Pull 0 P31, P32 Digital Mode 1 P31, P32 Analog Mode 0 P32 = Input P35 = Output 00 P33 = Input 01 P33 = Input 10 P33 = Input P34 = Output P34 = DM P34 = DM 0 P31 = Input P36 = Output 0 P30 = Input 1 P30 = Serial In P37 = Output P37 = Serial Out 0 Party ON 1 Party OFF Figure 49. Port 3 Mode Register Configuration I/O Ports UM001602-0904 Z8 CPU User Manual 89 Table 17. Port 3 Line Functions Function Line Signal Inputs P30 Input P31 Input P32 Input P33 Input P34 Output P35 Output P36 Output P37 Output Port 0 Handshake Input P32 DAV0/RDY0 Port 1 Handshake Input P33 DAV1/RDY1 Port 2 Handshake Input P31 DAV2/RDY2 Port 0 Handshake Output P35 RDY0/DAV0 Port 1 Handshake Output P34 RDY1/DAV1 Port 2 Handshake Output P36 RDY2/DAV2 Analog Comparator Input P31 AN1 P32 AN2 P33 REF P34 AN1-OUT P35 AN2-OUT P37 AN2-OUT Outputs Analog Comparator Output UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 90 Table 17. Port 3 Line Functions (Continued) Function Line Signal Interrupt Requests P30 IRQ3 P31 IRQ2 P32 IRQ0 P33 IRQ1 Serial Input (UART) P30 DI Serial Output (UART) P37 DO SPI Slave Select P35 SS SPI Clock P34 SK Counter/Timer P31 TIN P36 TOUT P34 DM External Memory Status Port Handshake When Ports 0, 1, and 2 are configured for handshake operation, a pair of lines from Port 3 are used for handshake controls. The handshake controls are interlocked to properly time asynchronous data transfers between the Z8® and a peripheral. One control line (DAV) functions as a strobe from the sender to indicate to the receiver that data is available. The second control line (RDY) acknowledges receipt of the sender’s data, and indicates when the receiver is ready to accept another data transfer. In input mode, data is latched into the Port’s input register by the first DAV signal, and is protected from being overwritten if additional pulses occur on the DAV line. This overwrite protection is maintained until the port data is read. In output mode, data written to the port is not protected and can be overwritten by the Z8® CPU during the handshake sequence. I/O Ports UM001602-0904 Z8 CPU User Manual 91 To avoid losing data, the software must not overwrite the port until the corresponding interrupt request indicates that the external device has latched the data. The software can always read Port 3 output and input handshake lines, but cannot write to the output handshake line. The following is the recommended setup sequence when configuring a Port for handshake operation for the first time after a reset: • • • Load P01M or P2M to configure the port for input/output Load P3 to set the Output Handshake bit to a logic 1 Load P3M to select HANDSHAKE mode for the port Once a data transfer begins, the configuration of the handshake lines should not be changed until the handshake is completed. Figures 50 and 51 show detailed operation for the handshake sequence. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 92 1 2 3 4 5 DAV (Input To Z8) RDY (Output From Z8) Data on Port (Input To Z8) Valid Data State 1. Port 3 output is High, indicating that the I/O device is ready to accept data. State 2. The I/O device puts data on the port and then activates the DAV input. This causes the data to be latched . into the port input register and generates an interrupt request. State 3. the Z8® CPU forces the Ready (RDY) output Low, signaling to the I/O device that the data has been latched. State 4. The I/O device returns the DAV line High in response to RDY going Low. State 5. the Z8® CPU RR software must respond to the interrupt request and read the contents of the port in order for t handshake sequence to be completed. The RDY line goes High if and only if the port has been read and DAV is High. This returns the interface to its initial state. Figure 50. Z8 Input Handshake I/O Ports UM001602-0904 Z8 CPU User Manual 93 1 2 3 4 5 RDY (Input To Z8) DAV (Output From Z8) Data on Port (Output From Z8) Valid Data State 1. RDY input is High indicating that the I/O device is ready to accept data. State 2. the Z8® CPU Writes to the port register to initiate a data transfer. Writing to the port outputs new data and forces DAV Low if and only if RDY is High. State 3. The I/O device forces RDY Low after latching the data. RDY Low causes an interrupt request to be generate the Z8® CPU can write new data responses to RDY going Low; however, the data is not output until State 5 State 4. The DAV output from the Z8® CPU is driven High in response to RDY going Low. State 5. The DAV goes High, the I/O device is free to raise RDY High thus returning the interface to its initial state. Figure 51. Z8 Output Handshake In applications requiring a strobed signal instead of the interlocked handshake, the Z8® CPU can satisfy this requirement as follows: UM001602-0904 • In the Strobed Input mode, data can be latched in the Port input register using the DAV input. The data transfer rate must allow enough time for the software to read the Port before strobing in the next character. The RDY output is ignored. • In the Strobed Output Mode, the RDY input should be tied to the DAV output. I/O Ports Z8 Family of Microcontrollers User Manual 94 Figures 52 and 53 illustrate the strobed handshake connections. P20–P27 I/O Device Z8 P36 DAV P31 RDY Figure 52. Output Strobed Handshake on Port 2 P20–P27 I/O Device Z8 P31 DAV Figure 53. Input Strobed Handshake on Port 2 I/O Port Reset Conditions Full Reset After a hardware reset, Watch–Dog Timer (WDT) reset, or a Power-On Reset (POR), Port Mode Registers P01M, P2M, and P3M are set as I/O Ports UM001602-0904 Z8 CPU User Manual 95 shown in Figures 54 through 56. Port 2 is configured for input operation on all bits and is set for open-drain (see Figure 55). If push-pull outputs are required for Port 2 outputs, remember to configure them using P3M. Please note that a WDT time-out from Stop-Mode Recovery does not do a full reset. Certain registers that are not reset after Stop-Mode Recovery will not be reset. For the condition of the Ports after Stop-Mode Recovery, please refer to specific device product specifications. In some cases, an Z8® MCU features the P01M, P2M, and P3M control register set back to the default condition after reset while others do not. All special I/O functions of Port 3 are inactive, with P33–P30 set as inputs and P37–P34 set as outputs (see Figure 56). Because the types and amounts of I/O vary greatly among the Z8® CPU family devices, the user is advised to review the selected device's product specifications for the register default state after reset. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 96 Register F8h Port 0–1 Mode Register (P01M) (Write-Only) 0 1 0 0 1 1 0 1 P00–P03 Mode 00 = Output 01 = Input 1X = A8–A11 Stack Selection 0 = External 1 = Internal P10–P17 Mode 00 = Byte Output 01 = Byte Output 10 = AD0–AD7 11 = High Impedance AD0–AD7, A8–A15, AS, DS, R/W External Memory Timing Normal = 0 Extended = 1 P04–P07 Mode Output = 00 Input = 01 A12–A15 = 1X Figure 54. Port 0/1 Reset I/O Ports UM001602-0904 Z8 CPU User Manual 97 Register F6h Port 2 Mode Register (P2M) (Write-Only) 1 1 1 1 1 1 1 1 Port 2 Mode 0 = Output 1 = Input Figure 55. Port 2 Reset UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 98 Register F7h Port 3 Mode Register (P3M) (Write-Only) 0 0 0 0 0 0 0 0 0 Port 2 Open-Drain 1 Port 2 Push–Pull 0 P31, P32 Digital Mode 1 P31, P32 Analog Mode 0 P32 = Input 1 P32 = DAV0/RDY0 P35 = Output P35 = RDY0/DAV0 00 01 10 11 P34 = Output P34 = DM P34 = DM P34 = RDY1/DAV1 P33 = Input P33 = Input P33 = Input P33 = DAV1/RDY1 0 P31 = Input 1 P32 = DAV2/RDY2 P36 = Output P36 = RDY2/DAV2 0 P30 = Input 1 P30 = Serial In P37 = Output P37 = Serial Out 0 Parity OFF 1 Parity ON Figure 56. Port 3 Mode Reset Analog Comparators Select Z8 devices include two independent on-chip analog comparators. See the device product specification for feature availability and use. Port 3, Pins P31 and P32 each have a comparator front end. The comparator reference voltage, pin P33, is common to both comparators. In analog mode, the P31 and P32 are the positive inputs to the comparators and P33 is the reference voltage supplied to both comparators. In digital mode, pin P33 can be used as a P33 register input or IRQ1 source. P34, P35, or P37 I/O Ports UM001602-0904 Z8 CPU User Manual 99 may output the comparator outputs by software-programming the PCON Register bit D0 to 1. Comparator Description Two on-board comparators can process analog signals on P31 and P32 with reference to the voltage on P33. The analog function is enabled by programming the Port 3 Mode Register (P3M bit 1). For interrupt functions during analog mode, P31 and P32 can be programmable as rising, falling, or both edge triggered interrupts (IRQ register bits 6 and bit 7). P33 cannot generate an external interrupt while in this mode. P33 can only generate interrupts in digital mode. Port 3 inputs must be in digital mode if Port 3 is a Stop-Mode Recovery source. The analog comparator is disabled in STOP mode. P31 can be used as TIN in analog or digital modes, but it must be referenced to P33, when in analog mode. Register F7h Port 3 Mode Register (P3M) (Write-Only) D1 0 = Digital Mode P31, P32, P33 1 = Analog Mode P31, P32, P33 Figure 57. Port 3 Input Analog Selection UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 100 ERF Bank F Register 00h Port Configuration Register (PCON) (Write-Only) D0 0 = P34, P35, or P37 Standard Outputs 1 = P34, P35, or P37 Comparator Outputs Figure 58. Port 3 Comparator Output Selection I/O Ports UM001602-0904 Z8 CPU User Manual 101 P30 P31 P32 P33 Port 3 (I/O or Control) Z8 P34 P35 P36 P37 Autolatch R ≈ 500 KΩ P30 Data Latch IRQ3 P30 R247 = P3M D1 1 = Analog 0 = Digital DIG. P31 (AN1) IRQ2, TIN, P31 Data Latch + - P32 (AN2) AN. IRQ0, P32 Data Latch + - P33 (REF) From Stop-Mode Recovery Source IRQ1, P33 Data Latch Figure 59. Port Configuration of Comparator Inputs on P31, P32, and P33 UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 102 P34 P34 OUT PIN P31 + REF (P33) P37 P37 OUT PIN P32 + REF (P33) PCON D0 0 P34, P37 Standard Output 1 P34, P37 Comparator Output Figure 60. Port 3 Configuration Comparator Programming Example of enabling analog comparator mode. LD P3M, #XXXX XX1Xb X = any binary number Example of enabling analog comparator output. I/O Ports UM001602-0904 Z8 CPU User Manual 103 LD RP, #%0Fh ;Sets register pointer to ;working register group 0 ;and Expanded Register ;File Bank F. LD R0, #XXXX XXX1b ;Enables comparator ;outputs using PCON ;Register programming. Comparator Operation After enabling the Analog Comparator mode, P33 becomes a common reference input for both comparators. The P33 (Ref) is hard wired to the reference inputs to both comparators and cannot be separated. P31 and P32 are always connected to the positive inputs to the comparators. P31 is the positive input to comparator AN1 while P32 is the positive input to comparator AN2. The outputs to comparators AN1 and AN2 are AN1-out and AN2-out, respectively. The comparator output reflects the relationship between the positive input to the reference input. Example If the voltage on AN1 is higher than the voltage on Ref then AN1-out will be at a high state. If voltage on AN2 is lower than the voltage on Ref then AN2-out will be at a Low state. In this example, when the Port 3 register is read, Bits D1 = 1 and D2 = 0. If the comparator outputs are enabled to come out on P34 and P37, then P34 = 1 and P37 = 0. Please note that the previous data stored in P34 and P37 is not disturbed. Once the comparator outputs are de-selected the stored values in the P34 and P37 register bits will be reflected on these pins again. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 104 Interrupts In the example from Section 5.8.3, P32 (AN2) will generate an interrupt based on the result of the comparison being low and the Interrupt Request Register (IRQ FAh) having bits D7 = 0 and D6 = 0. If IRQ D7 = 1 and D6 = 0 then both P31 and P32 would generate interrupts. Comparator Definitions VICR The usable voltage range for both positive inputs and the reference input is called the common mode voltage range (VICR). The comparator is not guaranteed to work if the inputs are outside of the VICR range. VOFFSET The absolute value of the voltage between the positive input and the reference input required to make the comparator output voltage switch is the input offset voltage (VOFFSET). If AN1 is 3.000V and Ref is 3.001V when the comparator output switches states then the Voffset = 1mV. IIO For CMOS voltage comparator inputs, the input offset current (IIO) is the leakage current of the CMOS input gate. Run Mode P33 is not available as an interrupt input during analog mode. P31 and P32 are valid interrupt inputs in conjunction with P33 (Ref) when in analog mode. P31 can still be used as TIN when analog mode is selected. If comparator outputs are required to be outputted on the Port 3 outputs, please refer to specific products specification for priority of mixing when other special features are sharing those same Port 3 pins. I/O Ports UM001602-0904 Z8 CPU User Manual 105 Halt Mode The analog comparators are functional during HALT mode if analog mode has been enabled. P31 and P32, in conjunction with P33 (Ref) will be able to generate interrupts. Only P33 cannot generate an interrupt Because the P33 input goes directly to the Ref input of the comparators and is disconnected from the interrupt sensing circuits. Stop Mode The analog comparators are disabled during STOP mode so it does not use any current at that time. If P31, P32, or P33 are used as a source for Stop-Mode Recovery, the Port 3 digital mode must be selected by setting bit D1 = 0 in the Port 3 Mode Register. Otherwise in STOP mode, the P31, P32, and P33 cannot be sensed. If analog mode was selected when entering STOP mode, it will still be enabled after a valid SMR triggered reset. Open-Drain Configuration All Z8® MCUs can configure Port 2 to provide open-drain outputs by programming the Port 3 Mode Register (P3M) bit D0 = 0. Register F7h Port 3 Mode Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Port 2 Configuration 1 = Pull-Ups Open-Drain 0 = Pull-Ups Active Figure 61. Port 2 Configuration Other Z8® MCUs feature a Port Configuration Register (PCON) for which Port 0 and Port 1 can be configured to provide open-drain outputs. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 106 The PCON Register is located in Expanded Register File (ERF) Bank F, Register 00h. See Figure 62. PCON (Fh) 00h D7 D6 D5 D4 D3 D2 D1 D0 Comparator Output Port 3 0 P34, P37 Standard Output* 1 P34, P37 Comparator Output 0 Port 1 Open Drain 1 Port 1 Push–pull Active * 0 Port 0 Open Drain 1 Port 0 Push–pull Active * 0 Port 0 Low EMI 1 Port 0 Standard * 0 Port 1 Low EMI 1 Port 1 Standard * 0 Port 2 Low EMI 1 Port 2 Standard * 0 Port 3 Low EMI 1 Port 3 Standard * * Default Setting After RESET Low EMI Oscillator 0 Low EMI 1 Standard * Figure 62. Port Configuration Register (Write-Only) Port 1 Open-Drain. Port 1, D1 can be configured as open-drain by resetting this bit (D1 = 0) or configured as push–pull active by setting this bit (D1 = 1). The default value is 1. Port 0 Open Drain. Port 0, D2 can be configured as open-drain by resetting this bit (D2 = 0) or configured as push–pull active by setting this bit (D2 = 1). The default value is 1. I/O Ports UM001602-0904 Z8 CPU User Manual 107 Low EMI Emission Some Z8® MCUs can be programmed to operate in a Low EMI Emission Mode using the Port configuration register (PCON). The PCON register allows the oscillator and all I/O ports to be programmed in the Low-EMI Mode independently. Other Z8® MCUs may offer a ROM Mask or OTP programming option to configure the Z8® MCU ports and oscillator globally to a Low-EMI mode (where the XTAL frequency is set equal to the internal system clock frequency. Use of the Low EMI feature results in: • • • • • The output pre-drivers slew rate reduced to 10 ns (typical) Low EMI output drivers have resistance of 200 Ω (typical) Low EMI Oscillator All output drivers are approximately 25 percent of the standard drive Internal SCLK ÷ TCLK = XTAL operation limited to a maximum of 4 MHz–250 ns cycle time, when Low EMI Oscillator is selected and system clock (SCLK = XTAL, SMR Reg. Bit D1 = 1) For Z8® MCUs having the PCON register feature, the following bits control the Low EMI options. Low EMI Port 0. Port 0, D3 can be configured as a Low EMI Port by resetting this bit (D3 = 0) or configured as a Standard Port by setting this bit (D3 = 1). The default value is 1. Low EMI Port 1. Port 1, D4 can be configured as a Low EMI Port by resetting this bit (D4 = 0) or configured as a Standard Port by setting this bit (D4 = 1). The default value is 1. Low EMI Port 2. Port 2, D5 can be configured as a Low EMI Port by resetting this bit (D5 = 0) or configured as a Standard Port by setting this bit (D5 = 1). The default value is 1. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 108 Low EMI Port 3. Port 3, D6 can be configured as a Low EMI Port by resetting this bit (D6 = 0) or configured as a Standard Port by setting this bit (D6 = 1). The default value is 1. Low EMI OSC. This D7 bit of the PCON Register controls the Low EMI oscillator. A 1 in this location configures the oscillator with standard drive, while a 0 configures the oscillator with low noise drive. The LowEMI mode will reduce the drive of the oscillator (OSC). The default value is 1. XTAL ÷ 2 mode is not affected by this bit. The maximum external clock frequency is 4 MHz when running in the Low EMI oscillator mode. Please refer to the selected device product specification for availability of the Low EMI feature and programming options. Input Protection All CMOS ROM Z8® MCUs have I/O pins with diode input protection. There is a diode from the I/O pad to VCC and to VSS. See Figure 63. I/O Ports UM001602-0904 Z8 CPU User Manual 109 VCC PIN VSS Figure 63. Diode Input Protection On CMOS OTP EPROM Z8® MCUs, the Port 3 inputs P31, P32, P33 and the XTAL 1 pin have only the input protection diode from pad to VSS. See Figure 64. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 110 PIN VSS Figure 64. OTP Diode Input Protection The high-side input protection diodes were removed on these pins to allow the application of +12.5V during the various OTP programming modes. For better noise immunity in applications that are exposed to system EMI, a clamping diode to VCC from these pins may be required to prevent entering the OTP programming mode or to prevent high voltage from damaging these pins. Z8 CMOS Autolatches I/O port bits that are configurable as inputs are protected against open circuit conditions using autolatches. An autolatch is a circuit which, in the event of an open circuit condition, latches the input at a valid CMOS level. This inhibits the tendency of the input transistors to self-bias in the forward active region, thus drawing excessive supply current. A simplified schematic of the CMOS Z8 I/O circuit is shown in Figure 65. I/O Ports UM001602-0904 Z8 CPU User Manual 111 VDD Open-Drain OE P Data Out PIN N Data In VDD Autolatch P N G1 Figure 65. Simplified CMOS Z8 I/O Circuit The operation of the autolatch circuit is straight-forward. Assume the input pad is latched at +5V (logic 1). The inverter G1 inverts the bit, turning the P-channel FET ON and the N-channel FET OFF. The output of the circuit is effectively shorted to VDD, returning +5V to the input. If the pad is then disconnected from the +5V source, the autolatch will hold the input at the previous state. If the device is powered up with the input float- UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 112 ing, the state of the autolatch will be at either supply, but which state is unpredictable. There are four operating conditions which will activate the autolatches. The first, which occurs when the input pin is physically disconnected from any source, is the most obvious. The second occurs when the input is connected to the output of a device with tri-state capability. The autolatch will also activate when the input voltage at the pin is not within 200 microvolts or so of either supply rail. In this case, the circuit will draw current, which is not significant compared to the ICC operating current of the device, but will increase ICC2 STOP mode current of the device dramatically. The fourth condition occurs when the I/O bit is configured as an output. Referring to the output section of Figure 65, there are two ways of tri-stating the port pin. The first is by configuring the port as an input, which disables the OE signal turning both transistors off. The second can be achieved in output mode by writing a 1 to the output port, then activating the open drain mode. Both transistors are again off, and the port bit is in a high impedance state. The autolatches then pull the input section toward VDD. Autolatch Model The autolatch’s equivalent circuit is shown in Figure 66. When the input is high, the circuit consists of a resistance Rp from VDD (the P-channel transistor in its ON state) and a much greater resistance Rh to GND. Current IAO flows from VDD to the output. When the input is low, the circuit may be modeled as a resistance Rp from GND (the N-channel transistor in the ON state) and a much greater resistance Rh to VDD. Current IAO now flows from the input to ground. The autolatch is characterized with respect to IAO, so the equivalent resistance Rp is calculated according to RP = (VDD–VIN)/IAO. The worst case equivalent resistance Rp (min) may be calculated at the worst case input voltage, VI = VIH (min). I/O Ports UM001602-0904 Z8 CPU User Manual 113 VDD VDD A0 RP RH Data in PIN Data in PIN Logic 0 Logic 1 RH A0 RP Figure 66. Autolatch Equivalent Circuit Design Considerations For circuits in which the autolatch is active, consideration should be given to the loading constraints of the autolatches. For example, with weak values of VIN, close to Vih (min) or Vil (max), pullup or pull-down resistances must be calculated using Ref = R/Rp. For best case STOP mode operation, the inputs should be within 200 mV of the supply rails. In output mode, if a port bit is forced into a tri-state condition, the autolatches will force the pad to VDD. If there is an external pulldown resistor on the pin, the voltage at the pin may not switch to GND due to the autolatch. As shown in Figure 67, the equivalent resistance of the autolatch and the external pulldown form a voltage divider, and if the external resistor is large, the voltage developed across it will exceed VIL(max). For worst case. VIL(max > VDD [REXT ÷ (REXT + RP)] REXT(max) = [(VIL(max) ÷ VDD) RP] ÷ [1—(VIL(max) ÷ VDD)] For VDD = 5.0 V and IAO = 5 µA, VIH(max) = 0.8 V: REXT(max) = (0.16 ÷ 1M) ÷ (1—0.16) = 190 KΩ. UM001602-0904 I/O Ports Z8 Family of Microcontrollers User Manual 114 Rp increases rapidly with VDD, so increased VDD will relax the requirement on Rext. In summary, the CMOS Z8 autolatch inhibits excessive current drain in Z8 devices by latching an open input to either VDD or GND. The effect of the autolatch on the I/O characteristics of the device may be modeled by a current IAO and a resistor Rp, whose value is VDD/IAO. VLO RP VIH (min.) REXT Figure 67. Effect of Pulldown Resistors on Autolatches I/O Ports UM001602-0904 Z8 CPU User Manual 115 Counters and Timers The Z8® CPU provides up to two 8-bit counter/timers, T0 and T1, each driven by its own 6-bit prescaler, PRE0 and PRE1 (see Figure 68). Both counter/timers are independent of the processor instruction sequence, that relieves software from time-critical operations such as interval timing or event counting. Some MCUs offer clock scaling using the SMR register. See the device product specification for clock available options. The following description is typical. Each counter/timer operates in either Single-Pass or Continuous mode. At the end-of-count, counting either stops or the initial value is reloaded and counting continues. Under software control, new values are loaded immediately or when the end-of-count is reached. Software also controls the counting mode, how a counter/timer is started or stopped, and its use of I/ O lines. Both the counter and prescaler registers can be altered while the counter/timer is running. UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 116 Internal Data Bus OSC Write Write D1 (SMR) ÷2 D0 (SMR) ÷4 ÷16 T0 Initial Value Register 6-Bit Down Counter 8-Bit Down Counter T0 Current Value Register IRQ4 6-Bit Down Counter 8-Bit Down Counter PRE1 Initial Value Register T1 Initial Value Register TOUT P36 IRQ5 External Clock ÷4 TIN P31 PRE0 Initial Value Register ÷2 Internal Clock Clock Logic Read Internal Clock Gated Clock Triggered Clock Write Write T1 Current Value Register Read Internal Data Bus Figure 68. Counter/Timer Block Diagram Counter/timers 0 and 1 are driven by a timer clock generated by dividing the internal clock by four. The divide-by-four stage, the 6-bit prescaler, and the 8-bit counter/timer form a synchronous 16-bit divide chain. Counter/timer 1 can also be driven by a external input (TIN) using P31. Port 3 line P36 can serve as a timer output (TOUT) through which T0, T1, or the internal clock can be output. The timer output will toggle at the end-of-count. The counter/timer, prescaler, and associated mode registers are mapped into the register file as shown in Figure 69. This allows the software to Counters and Timers UM001602-0904 Z8 CPU User Manual 117 treat the counter/timers as general-purpose registers, and eliminates the requirement for special instructions. Prescalers and Counter/Timers The prescalers, PRE0 (F5h) and PRE1 (F3h), each consist of an 8-bit register and a 6-bit down-counter as shown in Figure 68. The prescaler registers are write-only registers. Reading the prescalers returns the value FFh. Figures 70 and 71 show the prescaler registers. The six most significant bits (D2–D7) of PRE0 or PRE1 hold the prescalers count modulo, a value from 1 to 64 decimal. The prescaler registers also contain control bits that specify T0 and T1 counting modes. These bits also indicate whether the clock source for T1 is internal or external. These control bits will be discussed in detail throughout this chapter. The counter/timer registers, T0 (F4h) and T1 (F2h), each consist of an 8bit down-counter, a write-only register that holds the initial count value, and a read-only register that holds the current count value (Figure 68). The initial value can range from 1 to 256 decimal (01h,02h,..,00h). Figure 72 illustrates the counter/timer registers. UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 118 DEC HEX Identifiers 247 Port 3 Mode F7 245 T0 Prescaler F5 244 Timer/Counter0 F4 243 T1 Prescaler F3 242 Time/Counter1 F2 241 Timer Mode F1 Figure 69. Counter/Timer Register Map R245 PRE0 Prescaler 0 Register (%F5; Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Count Mode 0 = T0 Single Pass 1 = T0 Modulo-n Reserved (Must be 0) Prescaler Modulo (Range: 1-64 Decimal 01-00 HEX) Figure 70. Prescaler 0 Register Counters and Timers UM001602-0904 Z8 CPU User Manual 119 R243 PRE1 Prescaler 1 Register (%F3; Write-Only) U U U U U U 0 0 Count Mode 0 = T1 Single Pass 1 = T1 Modulo-n Clock Source 1 = T1 Internal 0 = T1 External (TIN) Prescaler Modulo (Range: 1-64 Decimal 01-00 HEX) Figure 71. Prescaler 1 Register R242 T1 Counter/Timer 1 Register (%F2; Write/Read Only) R244 T0 Counter/Timer 0 Register (%F4; Write/Read Only) D7 D6 D5 D4 D3 D2 D1 D0 Initial value when written (Range 1-256 decimal, 01-00 HEX) current value when read Figure 72. Counter/Timer 0 and 1 Registers UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 120 Counter/Timer Operation Under software control, counter/timers are started and stopped via the Timer Mode Register (TMR,F1h) bits D0–D3 (see Figure 73). Each counter/timer is associated with a Load bit and an Enable Count bit. Load and Enable Count Bits Setting the Load bit (D0 for T0 and D2 for T1) transfers the initial value in the prescaler and the counter/timer registers into their respective downcounters. The next internal clock resets bits D0 and D2 to 0, readying the Load bit for the next load operation. New values may be loaded into the down-counters at any time. If the counter/timer is running, it continues to do so and starts the count over with the new value. Therefore, the Load bit actually functions as a software re-trigger. R241 TMR Timer Mode Register (% F1; Read/Write) D3 D2 D1 D0 0 = No Function 1 = Load T0 0 = Disable T0 Count 1 = Enable T0 Count 0 = No Function 1 = Load T1 0 = Disable T1 Count 1 = Enable T1 Count Figure 73. Timer Mode Register The counter timers remain at rest as long as the Enable Count bits are 0. To enable counting, the Enable Count bit (D1 for T0 and D3 for T1) must Counters and Timers UM001602-0904 Z8 CPU User Manual 121 be set to 1. Counting actually starts when the Enable Count bit is written by an instruction. The first decrement occurs four internal clock periods after the Enable Count bit has been set. If T1 is configured to use an external clock, the first decrement begins on the next clock period. The Load and Enable Count bits can be set at the same time. For example, using the instruction: OR TMR,#03h sets both D0 and D1 of the TMR. This loads the initial values of PRE0 and T0 into their respective counters and starts the count after the M2T2 machine state after the operand is fetched (see Figure 74). R243 PRE1 Prescaler 1 Register (% F3; Write-Only) R245 PRE0 Prescaler 0 Register (% F5; Write-Only) D0 Count Mode 0 = T1 Single Pass 1 = T1 Modulo-n Figure 74. Starting The Count UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 122 M3 M1 M2 Mn T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 First Decrement Occurs Four Clock Periods Later TMR is Written, Counter/Timer is Loaded #03h is Fetched Figure 75. Counting Modes Prescaler Operations During counting, the programmed clock source drives the 6-bit Prescaler Counter. The counter is counted down from the value specified by bits of the corresponding Prescaler Register, PRE0 (bit 7 to bit 2) or PRE1 (bit 7 to bit 2; see Figures 70 and 71). When the Prescaler Counter reaches its end-of-count, the initial value is reloaded and counting continues. The prescaler never actually reaches 0. For example, if the prescaler is set to divide-by-three, the count sequence is: 3–2–1–3–2–1–3–2–1–3... Each time the prescaler reaches its end of count a carry is generated, that allows the Counter/Timer to decrement by one on the next timer clock input. When the Counter/Timer and the prescaler both reach the end-ofcount, an interrupt request is generated (IRQ4 for T0, IRQ5 for T1). Depending on the counting mode selected, the Counter/Timer will either come to rest with its value at 00h (Single-Pass Mode) or the initial value will be automatically reloaded and counting will continue (Continuous Mode). The counting modes are controlled by bit 0 of PRE0 and bit 0 of PRE1 (see Figure 75). A 0, written to this bit configures the counter for Counters and Timers UM001602-0904 Z8 CPU User Manual 123 Single-pass counting mode, while a 1 written to this bit configures the counter for Continuous mode. The Counter/Timer can be stopped at any time by setting the Enable Count bit to 0, and restarted by setting it back to 1. The Counter/Timer will continue its count value at the time it was stopped. The current value in the Counter/Timer can be read at any time without affecting the counting operation. Note: The prescaler registers are write-only and cannot be read. New initial values can be written to the prescaler or the Counter/Timer registers at any time. These values will be transferred to their respective down counters on the next load operation. If the Counter/Timer mode is continuous, the next load occurs on the timer clock following an end-ofcount. New initial values should be written before the load operation, because the prescalers always effectively operate in Continuous count mode. The time interval (i) until end-of-count, is given by the equation: i=txpxv in which t = four times the internal clock period. The internal clock frequency defaults to the external clock source (XTAL, ceramic resonator, and others) divided by 2. Some Z8 microcontrollers allow this divisor to be changed via the Stop-Mode Recovery register. See the product data sheet for available clock divisor options. t is equal to eight divided-by-XTAL frequency of the external clock source for T1 (external clock mode only). p = the prescaler value (1–63) for T0 and T1. The minimum prescaler count of 1 is achieved by loading 000001xx. The maximum prescaler count of 63 is achieved by loading 111111xx. v = the Counter/Timer value (1–256) UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 124 Minimum duration is achieved by loading 01h (1 prescaler output count), maximum duration is achieved by loading 00h (256 prescaler outputs counts). The prescaler and counter/timer are true divide-by-n counters. TOUT Modes The Timer Mode Register TMR (F1h; see Figure 76), is used in conjunction with the Port 3 Mode Register P3M (F7h; see Figure 77) to configure P36 for TOUT operation for T0 and T1. In order for TOUT to function, P36 must be defined as an output line by setting P3M bit 5 to 0. Output is controlled by one of the counter/timers (T0 or T1) or the internal clock. Register F1hR Timer Mode Register (TMR) (Read/Write) D7 D6 D3 D0 0 = No Function 1 = Load T0 0 = Disable T1 Count 1 = Enable T1 Count TOUT Modes: TOUT OFF = 00 T0 OUT = 01 T1 OUT = 10 Internal Clock OUT = 11 Figure 76. Timer Mode Register (TOUT Operation) Counters and Timers UM001602-0904 Z8 CPU User Manual 125 Register F7h Port 3 Mode Register (P3M) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 0 P31 = Input (TIN) 1 P31 = DAV2/RDY2 P36 = Output (TOUT) P36 = RDY2/DAV2 Figure 77. Port 3 Mode Register (TOUT Operation) The counter/timer to be output is selected by TMR bit 7 and bit 6. T0 is selected to drive the TOUT line by setting bit 7 to 0 and bit 6 to 1. Likewise, T1 is selected by setting bit 7 and bit 6 to 1 and 0, respectively. The counter/timer TOUT mode is turned off by setting TMR bit and bit 6 both to 0, freeing P36 to be a data output line. TOUT is initialized to a logic 1 whenever the TMR Load bit (bit 0 for T0 or bit 1 for T2) is set to 1. The TOUT configuration timer load, and Timer Enable Count bits for the counter/timer driving the TOUT pin can be set at the same time. For example, using the instruction: OR TMR,#43h • • • Configures T0 to drive the TOUT pin (P36) Sets the P36 TOUT pin to a logic 1 level Loads the initial PRE0 and T0 levels into their respective counters and starts the counter after the M2T2 machine state after the operand is fetched At end-of-count, the interrupt request line (IRQ4 or IRQ5), clocks a toggle flip-flop. The output of this flip-flop drives the TOUT line, P36. In all cases, when the selected counter/timer reaches its end-of-count, TOUT toggles to its opposite state (see Figure 78). If, for example, the counter/ UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 126 timer is in Continuous Counting Mode, Tout will have a 50 percent duty cycle output. This duty cycle can easily be controlled by varying the initial values after each end-of-count. The internal clock can be selected as output instead of T0 or T1 by setting TMR bit 7 and bit 6 both to 1. The internal clock (XTAL frequency ÷ 2) is then directly output on P36 (see Figure 79). While programmed as TOUT, P36 cannot be modified by a write to port register P3. However, the Z8® software can examine the P36 current output by reading the port register. IRQ4 (T0 End-of-Count) TMR D7–D6 = 01 ÷2 IRQ5 (T1 End-of-Count) P36 TOUT TMR D7–D6 = 10 Figure 78. T0 and T1 Output Through TOUT Counters and Timers UM001602-0904 Z8 CPU User Manual 127 Internal Clock OSC ÷2 P36 TOUT TMR D6 TMR D7 Figure 79. Internal Clock Output Through TOUT TIN Modes The Timer Mode Register TMR (F1h; see Figure 80) is used in conjunction with the Prescaler Register PRE1 (F3h; see Figure 81) to configure P31 as TIN. TIN is used in conjunction with T1 in one of four modes: • • • • External Clock Input Gated Internal Clock Triggered Internal Clock Retriggerable Internal Clock The TIN mode is restricted for use with timer 1 only. To enable the TIN mode selected (via TMR bits 4- 5), bit 1 of PRE1 must be set to 0. The counter/timer clock source must be configured for external by setting the PRE1 Register bit 2 to 1. The Timer Mode Register bit 5 and bit 4 can then be used to select the appropriate TIN operation. UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 128 For T1 to start counting as a result of a TIN input, the Enable Count bit (bit 3 in TMR) must be set to 1. When using TIN as an external clock or a gate input, the initial values must be loaded into the down counters by setting the Load bit (bit 2 in TMR) to a 1 before counting begins. In the descriptions of TIN that follow, it is assumed the programmer has performed these operations. Initial values are automatically loaded in Trigger and Retrigger modes so software loading is unnecessary. Register F1h Timer Mode Register (TMR) (Read/Write) D5 D4 TIN = Modes: External Clock Input = 00 Gate Input = 01 Trigger Input = 10 (Non-retriggerable) Trigger Input = 11 (Retriggerable) Figure 80. Timer Mode Register (TIN Operation) Register F3h Prescaler 1 Register (PRE1) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Clock Source 0 = T1 External Enable TIN Mode 1 = T1 Internal Disable TIN Mode Figure 81. Prescaler 1 Register (TIN Operation) Counters and Timers UM001602-0904 Z8 CPU User Manual 129 It is suggested that P31 be configured as an input line by setting P3M Register bit 5 to 0, although TIN is still functional if P31 is configured as a handshake input. Each High-to-Low transition on TIN generates an interrupt request IRQ2, regardless of the selected TIN mode or the enabled/disabled state of T1. IRQ2 must therefore be masked or enabled according to the requirements of the application. External Clock Input Mode The TIN External Clock Input Mode (TMR bit 5 and bit 4 both set to 0) supports counting of external events, where an event is considered to be a High-to-Low transition on TIN (see Figure 82). See the product data sheet for the minimum allowed TIN external clock input period (TP TIN). TMR D5–D4 = 00 TIN Clock IRQ5 P31 D D PRE1 Internal Clock T1 IRQ2 Figure 82. External Clock Input Mode Gated Internal Clock Mode The TIN Gated Internal Clock Mode (TMR bit 5 and bit 4 set to 0 and 1 respectively) measures the duration of an external event. In this mode, the T1 prescaler is driven by the internal timer clock, gated by a High level on UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 130 TIN (see Figure 83). T1 counts while TIN is High and stops counting while TIN is Low. Interrupt request IRQ2 is generated on the High-to-Low transition of TIN signalling the end of the gate input. Interrupt request IRQ5 is generated if T1 reaches its end-of-count. OSC ÷2 Internal Clock TMR D5–D4 = 01 ÷4 TIN Gate P31 D PRE1 T1 IRQ5 IRQ2 D Figure 83. Gated Clock Input Mode Triggered Input Mode The TIN Triggered Input Mode (TMR bits 5 and 4 are set to 1 and 0, respectively) causes T1 to start counting as the result of an external event (see Figure 84). T1 is then loaded and clocked by the internal timer clock following the first High-to-Low transition on the TIN input. Subsequent TIN transitions do not affect T1. In SINGLE-PASS mode, the Enable bit is reset whenever T1 reaches its end-of-count. Further TIN transitions will have no effect on T1 until software sets the Enable Count bit again. In Continuous mode, once T1 is triggered counting continues until software resets the Enable Count bit. Interrupt request IRQ5 is generated when T1 reaches its end-of-count. Counters and Timers UM001602-0904 Z8 CPU User Manual 131 OSC ÷2 Internal Clock TMR D5 = 1 ÷4 PRE1 T1 IRQ5 Edge Trigger TIN Trigger P31 D D TMR D5–D4 = 11 IRQ2 Figure 84. Triggered Clock Mode Retriggerable Input Mode The TIN Retriggerable Input Mode (TMR bits 5 and 4 are set to 1) causes T1 to load and start counting on every occurrence of a High-to-Low transition on TIN (see Figure 84). Interrupt request IRQ5 will be generated if the programmed time interval (determined by T1 prescaler and counter/ timer register initial values) has elapsed because the last High-to-Low transition on TIN. In Single-Pass Mode, the end-of-count resets the Enable Count bit. Subsequent TIN transitions will not cause T1 to load and start counting until software sets the Enable Count bit again. In Continuous Mode, counting continues once T1 is triggered until software resets the Enable Count bit. When enabled, each High-to-Low TIN transition causes T1 to reload and restart counting. Interrupt request IRQ5 is generated on every end-of-count. UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 132 Cascading Counter/Timers For some applications, it may be necessary to measure a time interval greater than a single counter/timer can measure. In this case, TIN and TOUT can be used to cascade T0 and T1 as a single unit (see Figure 85). T0 should be configured to operate in Continuous mode and to drive TOUT. TIN should be configured as an external clock input to T1 and wired back to TOUT. On every other T0 end-of-count, TOUT undergoes a High-to-Low transition that causes T1 to count. T1 can operate in either Single-Pass or Continuous mode. When the T1 end-of-count is reached, interrupt request IRQ5 is generated. Interrupt requests IRQ2 (TIN High-to-Low transitions) and IRQ4 (T0 end-of-count) are also generated but are most likely of no importance in this configuration and should be disabled. OSC ÷2 ÷4 PRE0 T0 ÷2 P36 TOUT TIN P31 IRQ4 PRE1 T1 IRQ5 IRQ2 Figure 85. Cascaded Counter/Timers Reset Conditions After a hardware reset, the counter/timers are disabled and the contents of the counter/timer and prescaler registers are undefined. However, the counting modes are configured for Single-Pass and the T1 clock source is set for external. Counters and Timers UM001602-0904 Z8 CPU User Manual 133 R242 T1 Counter/Timer 1 Register (%F2; Write/Read Only) R244 T0 Counter/Timer 0 Register (%F4; Write/Read Only) U U U U U U U U Initial value when written (Range 1–256 decimal, 01–00 HEX) current value when read Figure 86. Counter/Timer Reset TIN is set for External Clock mode, and the TOUT mode is off. Figures 87 through 89 show the binary reset values of the Prescaler, Counter/Timer, and Timer Mode registers. R243 PRE1 PRESCALER 1 REGISTER (%F3; WRITE-ONLY) U U U U U U 0 0 COUNT MODE 0 = T1 SINGLE PASS 1 = T1 MODULO-N CLOCK SOURCE 1 = T1 INTERNAL 0 = T1 EXTERNAL (TIN) PRESCALER MODULO (RANGE: 1–64 DECIMAL 01–00 HEX) Figure 87. Prescaler 1 Register Reset UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 134 R245 PRE0 Prescaler 0 Register (%F5; Write-Only) U U U U U U U 0 Count Mode 0 = T0 Single Pass 1 = T0 Modulo-n Reserved (Must be 0) Prescaler Modulo (Range: 1–64 Decimal 01–00 HEX) Figure 88. Prescaler 0 Reset Counters and Timers UM001602-0904 Z8 CPU User Manual 135 R241 TMR Timer Mode Register (% F1; Read/Write) 0 0 0 0 0 0 0 0 0 = No Function 1 = Load T0 0 = Disable T0 Count 1 = Enable T0 Count 0 = No Function 1 = Load T1 0 = Disable T1 Count 1 = Enable T1 Count TIN = Modes: External Clock Input = 00 Gate Input = 01 Trigger Input = 10 (Non-retriggerable) Trigger Input = 11 (Retriggerable) TOUT Modes: TOUT OFF = 00 T0 OUT = 01 T1 OUT = 10 Internal Clock OUT = 11 Figure 89. Timer Mode Register Reset UM001602-0904 Counters and Timers Z8 Family of Microcontrollers User Manual 136 Counters and Timers UM001602-0904 Z8 CPU User Manual 137 Interrupts The Z8® CPU allows 6 different interrupts from a variety of sources; up to four external inputs, the on-chip Counter/Timer(s), software, and serial I/O peripherals. These interrupts can be masked and their priorities set by using the Interrupt Mask and the Interrupt Priority Registers. All six interrupts can be globally disabled by resetting the master Interrupt Enable, bit 7 in the Interrupt Mask Register, with a Disable Interrupt (DI) instruction. Interrupts are globally enabled by setting bit 7 with an Enable Interrupt (EI) instruction. HEX Identifier Interrupt Mask FBh IMR Interrupt Request FAh IRQ Interrupt Priority F9h IPR Register 7 Figure 90. Interrupt Control Registers There are three interrupt control registers: the Interrupt Request Register (IRQ), the Interrupt Mask register (IMR), and the Interrupt Priority Register (IPR). Figure 90 shows addresses and identifiers for the interrupt control registers. Figure 91 is a block diagram showing the Interrupt Mask and Interrupt Priority logic. UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 138 The Z8® family supports both vectored and polled interrupt handling. Details on vectored and polled interrupts can be found later in this chapter. IRQ0–IRQ5 6 IRQ IMR Global Interrupt Enable 6 IPR Interrupt Request Priority Logic Vector Select Figure 91. Interrupt Block Diagram Note: See the selected Z8 CPU's product specification for the exact interrupt sources supported. Interrupts UM001602-0904 Z8 CPU User Manual 139 Interrupt Sources Table 18 presents the interrupt types, sources, and vectors available in the Z8® family of processors. Table 18. Interrupt Types, Sources, and Vectors Name Sources Vector Location Comments IRQ0 DAV0, IRQ0, Comparator 0,1 External (P32), Edge Triggered; Internal IRQ1 DAV1, IRQ1 2,3 External (P33), Edge Triggered; Internal IRQ2 DAV2, IRQ2, TIN, Comparator 4,5 External (P31), Edge Triggered; Internal IRQ3 6,7 External (P30) or (P32), Edge Triggered; Internal Serial In 6,7 Internal T0 8,9 Internal Serial Out 8,9 Internal T1 10,11 Internal IRQ5 External Interrupt Sources External sources involve interrupt request lines IRQ0–IRQ3. IRQ0, IRQ1, and IRQ2 can be generated by a transition on the corresponding Port 3 pin (P32, P33, and P31 correspond to IRQ0, IRQ1, and IRQ2, respectively). Figure 92 is a block diagram for interrupt sources IRQ0, IRQ1, and IRQ2. UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 140 The interrupt sources and trigger conditions are device dependent. See the device product specification to determine available sources (internal and external), triggering edge options, and exact programming details. IRQm m = 0,1,2 n = 2, 3, 1 P3n Multiple Input and Signal Conditioning Circuitry S Q D Q Q D R System Clock (Internal) Figure 92. Interrupt Sources IRQ0-IRQ2 Block Diagram When the Port 3 pin (P31, P32, or P33) transitions, the first flip-flop is set. The next two flip-flops synchronize the request to the internal clock and delay it by two internal clock periods. The output of the last flip-flop (IRQ0, IRQ1, or IRQ2) goes to the corresponding Interrupt Request Register. IRQ3 can be generated from an external source only if Serial In is not enabled. Otherwise, its source is internal. The external request is generated by a Low edge signal on P30 as shown in Figure 93. Again, the external request is synchronized and delayed before reaching IRQ3. Some Z8 products replace P30 with P32 as the external source for IRQ3. In this case, IRQ3 interrupt generation follows the logic as illustrated in Figure 92. Although interrupts are edge triggered, minimum interrupt request Low and High times must be observed for proper operation. See the device product specification for exact timing requirements on external interrupt requests (TWIL, TWIH). Interrupts UM001602-0904 Z8 CPU User Manual 141 P3M6 PIN D Q D Q (IRQ3 Serial In) IRQ3 Clock IRQ3 External Source IRQ3 Internal Source Serial Receiver Figure 93. Interrupt Source IRQ3 Block Diagram Internal Interrupt Sources Internal sources involve interrupt requests IRQ0, IRQ2, IRQ3, IRQ4, and IRQ5. Internal sources are ORed with the external sources, so either an internal or external source can trigger the interrupt. Internal interrupt sources and trigger conditions are device dependent. See the device product specification to determine available sources, triggering edge options, and exact programming details. For more details on the internal interrupt sources, refer to the chapters describing the Counter/ Timer, I/O ports, and Serial I/O. Interrupt Request Register Logic and Timing Figure 94 shows the logic diagram for the Interrupt Request (IRQ) Register. The leading edge of the request will set the first flip-flop, that will remain set until interrupt requests are sampled. Requests are sampled internally during the last clock cycle before an opcode fetch (see Figure 95). External requests are sampled two internal UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 142 clocks earlier, due to the synchronizing flip-flops shown in Figures 92 and 93. At sample time the request is transferred to the second flip-flop in Figure 94, that drives the interrupt mask and priority logic. When an interrupt cycle occurs, this flip-flop will be reset only for the highest priority level that is enabled. The user has direct access to the second flip-flop by reading and writing the IRQ Register. IRQ is read by specifying it as the source register of an instruction and written by specifying it as the destination register. Q Q IRQ0–IRQ5 S To Mask and Priority Logic Sample Clock R R From Priority Logic Figure 94. IRQ Register Logic Interrupts UM001602-0904 Z8 CPU User Manual 143 Mn M1 M2 T1 T2 T3 T1 T2 T3 T1 T2 T3 Interrupt Request Sampled Internally External Interrupt Request Sampled Figure 95. Interrupt Request Timing Interrupt Initialization After reset, all interrupts are disabled and must be initialized before vectored or polled interrupt processing can begin. The Interrupt Priority Register (IPR), Interrupt Mask Register (IMR), and Interrupt Request Register (IRQ) must be initialized, in that order, to start the interrupt process. Interrupt Priority Register Initialization The Interrupt Priority Register (IPR) shown in Figure 96 is a write-only register that sets priorities for the vectored interrupts in order to resolve simultaneous interrupt requests. (There are 48 sequence possibilities for interrupts.) The six interrupt levels IRQ0-IRQ5 are divided into three groups of two interrupt requests each. One group contains IRQ3 and IRQ5. The second group contains IRQ0 and IRQ2, while the third group contains IRQ1 and IRQ4. Priorities can be set both within and between groups as shown in Tables 19 and 20. Bits 1, 2, and 5 define the priority of the individual members within the three groups. Bits 0, 3, and 4 are encoded to define six priority orders between the three groups. Bits 6 and 7 are reserved. UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 144 Register F9h Interrupt Priority Register (IPR) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Interrupt Group Priority Bits Priority 000 001 010 011 100 101 110 111 Reserved C>A>B A>B>C A>C>B B>C>A C>B>A B>A>C Reserved Group C (IRQ1 and IRQ4 Priority) 0 = IRQ1 > IRQ4 1 = IRQ4 > IRQ1 Group B (IRQ0 and IRQ2 Priority) 0 = IRQ2 > IRQ0 1 = IRQ0 > IRQ2 Group A (IRQ3 and IRQ5 Priority) 0 = IRQ5 > IRQ3 1 = IRQ3 > IRQ5 Reserved (Must be 0) Figure 96. Interrupt Priority Register Table 19. Interrupt Priority Priority Group Bit Value Highest Lowest C Bit 1 0 IRQ1 IRQ4 1 IRQ4 IRQ1 0 IRQ2 IRQ0 1 IRQ0 IRQ2 B Interrupts Bit 2 UM001602-0904 Z8 CPU User Manual 145 Table 19. Interrupt Priority (Continued) Priority Group Bit Value Highest Lowest A Bit 5 0 IRQ5 IRQ3 1 IRQ3 IRQ5 Table 20. Interrupt Group Priority Bit Pattern Group Priority Bit 4 Bit 3 Bit 0 High Medium Low 0 0 0 Not Used 0 0 1 C A B 0 1 0 A B C 0 1 1 A C B 1 0 0 B C A 1 0 1 C B A 1 1 0 B A C 1 1 1 Not Used Interrupt Mask Register Initialization The Interrupt Mask Register individually or globally enables or disables the six interrupt requests (see Figure 97). When bit 0 to bit 5 are set to 1, the corresponding interrupt requests are enabled. Bit 7 is the master enable and must be set before any of the individual interrupt requests can be recognized. Resetting bit 7 globally disables all of the interrupt requests. Bit 7 is set and reset by the EI and DI instructions. It is automat- UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 146 ically reset during an interrupt service routine and set following the execution of an Interrupt Return (IRET) instruction. Bit 7 must be reset by the DI instruction before the contents of the Interrupt Mask Register or the Interrupt Priority Register are changed except: • • Immediately after a hardware reset Immediately after executing an interrupt service routine and before IMR bit 7 has been set by any instruction Register FBh Interrupt Request Register (IMR) (Read/Write) D7 D6 D5 D4 D3 D2 D1 D0 0 = Disables IRQ0 1 = Enables IRQ0 0 = Disables IRQ1 1 = Enables IRQ1 0 = Disables IRQ2 1 = Enables IRQ2 0 = Disables IRQ3 1 = Enables IRQ3 0 = Disables IRQ4 1 = Enables IRQ4 0 = Disables IRQ5 1 = Enables IRQ5 0 = Disables RAM Protect 1 = Enables RAM Protect 0 = Disables Interrupt 1 = Enables Interrupt Figure 97. Interrupt Mask Register Interrupts UM001602-0904 Z8 CPU User Manual 147 The RAM Protect option is selected at ROM mask submission time or at EPROM program time. If not selected or not an available option, this bit is reserved and must be 0. Interrupt Request Register Initialization The Interrupt Request Register (IRQ), shown in Figure 98, is a read/write register that stores the interrupt requests for both vectored and polled interrupts. When an interrupt is made on any of the six, the corresponding bit position in the register is set to 1. Bit 0 to bit 5 are assigned to interrupt requests IRQ0 to IRQ5, respectively. Whenever Power-On Reset (POR) is executed, the IRQ resister is reset to 00h and disabled. Before the IRQ register will accept requests, it must be enabled by executing an ENABLE INTERRUPTS (EI) instruction. Setting the Global Interrupt Enable bit in the Interrupt Mask Register (IMR, bit 7) will not enable the IRQ. Execution of the EI instruction is required (see Figure 99). For polled processing, IRQ must still be initialized by an EI instruction. To properly initialize the IRQ register, the following code is provided. CLR IMR // Make sure vectored interrupts are disabled. EI // Enable IRQ register, otherwise read only. // Not required if interrupts were previously enabled. DI // Disable interrupt heading. Note: IRQ is always cleared to 00h and is read only until the first EI instruction, which enables the IRQ to be read/write. UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 148 Register FAh Interrupt Request Register (IRQ) (Read/Write) D7 D6 D5 D4 D3 D2 D1 D0 0 = IRQ0 RESET 1 = IRQ0 SET 0 = IRQ1 RESET 1 = IRQ1 SET 0 = IRQ2 RESET 1 = IRQ2 SET 0 = IRQ3 RESET 1 = IRQ3 SET 0 = IRQ4 RESET 1 = IRQ4 SET 0 = IRQ5 RESET 1 = IRQ5 SET Reserved /Int Edge Select Figure 98. Interrupt Request Register IMR is cleared before the IRQ enabling sequence to insure no unexpected interrupts occur when EI is executed. This code sequence should be executed prior to programming the application required values for IPR and IMR. IRQ bits 6 and 7 are device dependent. When reserved, the bits are not used and will return a 0 when read. When used as the Interrupt Edge select bits, the configuration options are as show in Table 21. Interrupts UM001602-0904 Z8 CPU User Manual 149 Table 21. IRQ Register Configuration* IRQ Interrupt Edge D7 D6 P31 P32 0 0 F F 0 1 F R 1 0 R F 1 1 R/F R/F *Note: F = Falling Edge; R = Rising Edge. The proper sequence for programming the interrupt edge select bits is (assumes IPR and IMR have been previously initialized). DI ;Inhibit all interrupts until input edges are configured. OR IRQ,#XX 000000b EI ;Configure interrupt; do not disturb edges as required—IRQ 0-5. ;Reenable interrupts. El Instruction Interrupt Request Register (IRQ, FAh) S RESET R POR Figure 99. IRQ Reset Functional Logic Diagram UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 150 IRQ Software Interrupt Generation IRQ can be used to generate software interrupts by specifying IRQ as the destination of any instruction referencing the Z8® Standard Register File. These Software Interrupts (SWI) are controlled in the same manner as hardware generated requests (in other words, the IPR and the IMR control the priority and enabling of each SWI level). To generate a SWI, the appropriate request bit in the IRQ is set as follows: ORIRQ, #NUMBER where the immediate data, NUMBER, has a 1 in the bit position corresponding to the appropriate level of the SWI. For example, if an SWI is required on IRQ5, NUMBER would have a 1 in bit 5: OR IRQ, #00100000b With this instruction, if the interrupt system is globally enabled, IRQ5 is enabled, and there are no higher priority pending requests, control is transferred to the service routine pointed to by the IRQ5 vector. Vectored Processing Each Z8 interrupt level has its own vector. When an interrupt occurs, control passes to the service routine pointed to by the interrupt’s vector location in program memory. The sequence of events for vectored interrupts is as follows: • • • • • Interrupts PUSH PC Low byte on stack PUSH PC High byte on stack PUSH FLAGS on stack Fetch High byte of vector Fetch Low byte of vector UM001602-0904 Z8 CPU User Manual 151 • Branch to service routine specified by vector Figures 100 and 101 show the vectored interrupt operation. SP and Stack before an interrupt SP Top of Stack SP and Stack after an interrupt SP PC LOW Byte PC HIGH Byte FLAGS Figure 100. Effects of an Interrupt on the Stack UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 152 Program Memory XXFFh Interrupt Service Routine PC HIGH Byte FLAGS 000Ch Vector Selected By Priority Logic Interrupt Vector Table 0000h Figure 101. Interrupt Vectoring Interrupts UM001602-0904 Z8 CPU User Manual 153 Vectored Interrupt Cycle Timing The interrupt acknowledge cycle time is 24 internal clock cycles and is shown in Figure 102. In addition, two internal clock cycles are required for the synchronizing flip-flops. The maximum interrupt recognition time is equal to the number of clock cycles required for the longest executing instruction present in the user program (assumes worst case condition of interrupt sampling, Figure 95, just prior to the interrupt occurrence). To calculate the worst case interrupt latency (maximum time required from interrupt generation to fetch of the first instruction of the interrupt service routine), sum these components: Worst Case Interrupt Latency ≈ 24 INT CLK (interrupt acknowledge time) + # TPC of longest instruction present in the user's application program + 2TPC (internal synchronization time). M2 M1 M3 Stack Push Stack Push Fetch Vector High Stack Push Fetch Vector Low M1 M2 Internal Clock AS /DS For Stack External Only Odd Vector Address A0-A7 OUT PC PC+1 PC SP-1 PCL SP-2 PCH SP-3 FLAGS VECT VECT+1 Even Vector Address A0-A7 IN Op Code (Discarded) VECTH VECTL First Instruction Of Interrupt Service Routine R/W For Stack External Only Figure 102. Z8 Interrupt Acknowledge Timing UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 154 Nesting of Vectored Interrupts Nesting of vectored interrupts allows higher priority requests to interrupt a lower priority request. To initiate vectored interrupt nesting, do the following during the interrupt service routine: • • • • • • Push the old IMR on the stack • Execute IRET Load IMR with a new mask to disable lower priority interrupts Execute EI instruction Proceed with interrupt processing After processing is complete, execute DI instruction Restore the IMR to its original value by returning the previous mask from the stack Depending on the application, some simplification of the above procedure may be possible. Polled Processing Polled interrupt processing is supported by masking off the IRQ to be polled. This is accomplished by clearing the corresponding bits in the IMR. To enable any interrupt, first the interrupt mechanism must be engaged with an EI instruction. If only polled interrupts are to be serviced, execute: EI ;Enable interrupt mechanism DI ;Disable vectored interrupts. To initiate polled processing, check the bits of interest in the IRQ using the Test Under Mask (TM) instruction. If the bit is set, call or branch to Interrupts UM001602-0904 Z8 CPU User Manual 155 the service routine. The service routine services the request, resets its Request Bit in the IRQ, and branches or returns back to the main program. An example of a polling routine is as follows: TM IRQ, #MASKA ;Test for request JR Z, NEXT ;If no request go to NEXT CALL SERVICE ;If request is there, then ;service it NEXT: . . . SERVICE: ;Process Request . . . AND IRQ, #MASKB ;Clear Request Bit RET ;Return to next In this example, if IRQ2 is being polled, MASKA will be 00000100b and MASKB will be 11111011b. Reset Conditions Upon reset, all bits in IPR are undefined. In IMR, bit 7 is 0 and bits 0–6 are undefined. The IRQ register is reset and held in that state until an enable interrupt (EI) instruction is executed. UM001602-0904 Interrupts Z8 Family of Microcontrollers User Manual 156 Interrupts UM001602-0904 Z8 CPU User Manual 157 Power-Down Modes In addition to the standard RUN mode, the Z8® CPU supports two PowerDown modes to minimize device current consumption. The two modes supported are HALT and STOP. Halt Mode Operation HALT mode suspends instruction execution and turns off the internal CPU clock. The on-chip oscillator circuit remains active so the internal clock continues to run and is applied to the Counter/Timer(s) and interrupt logic. To enter HALT mode, it is necessary to first flush the instruction pipeline to avoid suspending execution in mid-instruction. To do this, the application program must execute a NOP instruction (opcode = FFh) immediately before the HALT instruction (opcode 7Fh), that is: FF NOP ;clear the instruction pipeline 7F HALT ;enter HALT mode HALT mode is exited by interrupts, either externally or internally generated. Upon completion of the interrupt service routine, the user program continues from the instruction after HALT. HALT mode may also be exited via a POR/RESET activation or a Watch– Dog Timer (WDT) time-out. (See the product data sheet for WDT availability). In this case, program execution will restart at the reset restart address 000Ch. To further reduce power consumption in HALT mode, some Z8 family devices allow dynamic internal clock scaling. Clock scaling may be accomplished on the fly by reprogramming bit 0 and/or bit1 of the StopMode Recovery register (SMR). See Figure 103 on page 160. UM001602-0904 Power-Down Modes Z8 Family of Microcontrollers User Manual 158 Note: Internal clock scaling directly affects Counter/Timer operation—adjustment of the prescaler and downcounter values may be required. To determine the actual HALT mode current (ICC1) value for the various optional modes available, see the related Z8 device’s product specification. Stop Mode Operation STOP mode provides the lowest possible device standby current. This instruction turns off the on-chip oscillator and internal system clock. To enter STOP mode, it is necessary to first flush the instruction pipeline to avoid suspending execution in mid-instruction. To do this, the application program must execute a NOP instruction (opcode = FFh) immediately before the STOP instruction (opcode = 6Fh), that is, FF NOP ;clear the instruction pipeline 6F STOP ;enter STOP mode STOP mode is exited by any one of the following resets: Power-On Reset activation, WDT time out (if available), or a Stop-Mode Recovery source. Upon reset generation, the processor will always restart the application program at address 000Ch. POR/RESET activation is present on all Z8 devices and is implemented as a reset pin and/or an on-chip power on reset circuit. Some Z8 devices allow for the on-chip WDT to run in STOP mode. If so activated, the WDT time-out will generate a reset some fixed time period after entering STOP mode. Stop-Mode Recovery by the WDT will increase STOP mode standby current (ICC2). This is due to the WDT clock and divider circuitry that is now enabled and running to support this recovery mode. See the product data sheet for actual ICC2 values. Power-Down Modes UM001602-0904 Z8 CPU User Manual 159 All Z8 devices provide some form of dedicated Stop-Mode Recovery (SMR) circuitry. Two SMR methods are implemented—a single fixed input pin or a flexible, programmable set of inputs. The selected Z8 device product specification should be reviewed to determine the SMR options available for use. For devices that support SPI, the slave mode compare feature also serves as a SMR source. In the simple case, a low level applied to input pin P27 will trigger a SMR. To use this mode, pin P27 (I/O Port 2, bit 7) must be configured as an input before STOP mode is entered. The low level on P27 must meet a minimum pulse width TWSM. (See the product data sheet) to trigger the device reset mode). Some Z8 devices provide multiple SMR input sources. The appropriate SMR source is selected via the SMR Register. Use of specialized SMR modes (P2.7 input or SMR register based) or the WDT time-out (only when in STOP mode) provide a unique reset operation. Some control registers are initialized differently for a SMR/WDT triggered POR than a standard reset operation. See the product specification (register file map) for exact details. To determine the actual STOP mode current (ICC2) value for the optional SMR modes available, see the selected Z8 device’s product data sheet. STOP mode current (ICC2) will be minimized when: • • • • UM001602-0904 VCC is at the low end of the devices operating range WDT is off in STOP mode Output current sourcing is minimized All inputs (digital and analog) are at the low or high rail voltages Power-Down Modes Z8 Family of Microcontrollers User Manual 160 Stop-Mode Recovery Register This register selects the clock divide value and determines the mode of Stop-Mode Recovery (see Figure 103). All bits are Write-Only, except bit 7, that is Read-Only. Bit 7 is a flag bit that is hardware set on the condition of stop-recovery and reset by a power-on cycle. Bit 6 controls whether a low level or a high level is required from the recovery source. Bit 5 controls the reset delay after recovery. Bits 2, 3, and 4, of the SMR register, specify the source of the Stop-Mode Recovery signal. Bits 0 and 1 control internal clock divider circuitry. The SMR is located in Bank F of the Expanded Register File at address 0Bh. SMR (Fh) 0B D7 D6 D5 D4 D3 D2 D1 D0 SCLK ÷ TCLK Divide-by-16 0 OFF ** 1 ON External Clock Divide by 2 0 SCLK ÷ TCLK = XTAL ÷ 2* 1 SCLK ÷ TCLK = XTAL Stop-Mode Recovery Source 000 POR Only and/or External Reset 001 P30 010 P31 011 P32 100 P33 101 P27 110 P2 NOR 0–3 111 P2 NOR 0–7 Stop Delay 0 OFF 1 ON* Stop Recovery Level 0 Low* 1 High Stop Flag (Read Only) 0 POR* 1 Stop Recovery * Default setting after RESET. ** Default setting after RESET and Stop-Mode Recovery. Figure 103. Stop-Mode Recovery Register (Write-Only Except Bit D7, Which Is Read-Only) Power-Down Modes UM001602-0904 Z8 CPU User Manual 161 The SMR register is available in select Z8 CPU products. Refer to the device product specification to determine SMR options available. SCLK ÷ TCLK Divide-by-16 Select. This D0 bit of the SMR controls a divide-by-16 prescaler of SCLK ÷ TCLK. The purpose of this control is to selectively reduce device power consumption during normal processor execution (SCLK control) and/or HALT mode (where TCLK sources counter/timers and interrupt logic). External Clock Divide-by-Two. This D1 bit can eliminate the oscillator divide-by-two circuitry. When this bit is 0, the System Clock (SCLK) and Timer Clock (TCLK) are equal to the external clock frequency divided by two. The SCLK ÷ TCLK is equal to the external clock frequency when this bit is set (D1 = 1). Using this bit together with D7 of PCON helps further lower EMI (D7 (PCON) = 0, D1 (SMR) = 1). The default setting is zero. Stop-Mode Recovery Source. The D2, D3, and D4 bits of the SMR specify the wake-up source of the stop-recovery and (Table 22 and Figure 104). Table 22. Stop-Mode Recovery Source SMR: 432 UM001602-0904 D4 D3 D2 Description of Operation 0 0 0 POR and/or external reset recovery. 0 0 1 P30 transition. 0 1 0 P31 transition (not in Analog Mode). 0 1 1 P32 transition (not in Analog Mode). 1 0 0 P33 transition (not in Analog Mode). Power-Down Modes Z8 Family of Microcontrollers User Manual 162 Table 22. Stop-Mode Recovery Source SMR: 432 D4 D3 D2 Description of Operation 1 0 1 P27 transition. 1 1 0 Logical NOR of P20 through P23. 1 1 1 Logical NOR of P20 through P27. Stop-Mode Recovery Delay Select. This D5 bit, if High, enables the TPOR RESET delay after Stop-Mode Recovery. The default configuration of this bit is 1. If the fast wake up is selected, the Stop-Mode Recovery source is kept active for at least 5 TpC. Stop-Mode Recovery Edge Select. A 1 in this D6 bit position indicates that a high level on any one of the recovery sources wakes the Z8® CPU from STOP mode. A 0 indicates low-level recovery. The default is 0 on POR (see Figure 104). Cold or Warm Start. This D7 bit is set by the device upon entering STOP mode. A 0 in this bit (cold) indicates that the device reset by POR/ WDT RESET. A 1 in this bit (warm) indicates that the device awakens by a SMR source. Power-Down Modes UM001602-0904 Z8 CPU User Manual 163 SMR D4 D3 D2 0 0 0 SMR D4 D3 D2 SMR D4 D3 D2 SMR D4 D3 D2 VDD 0 0 1 1 0 0 1 0 1 0 1 0 0 1 1 P20 P30 P27 P31 P33 P32 P23 SMR D4 D3 D2 1 1 0 SMR D4 D3 D2 1 1 0 P20 P27 To POR RESET Stop Mode Recovery Edge Select (SMR) To P33 Data Latch and IRQ1 MUX P33 From Pads Digital/Analog Mode Select (P3M) Figure 104. Stop-Mode Recovery Source If P31, P32, or P33 are to be used for a SMR source, the digital mode of operation must be selected prior to entering STOP mode. UM001602-0904 Power-Down Modes Z8 Family of Microcontrollers User Manual 164 Power-Down Modes UM001602-0904 Z8 CPU User Manual 165 Serial Input/Output UART Introduction Select Z8 CPU® microcontrollers contain an on-board full-duplex Universal Asynchronous Receiver/Transmitter (UART) for data communications. The UART consists of a Serial I/O Register (SIO) located at address F0h, and its associated control logic (see Figure 105). The SIO is actually two registers, the receiver buffer and the transmitter buffer, which are used in conjunction with Counter/Timer T0 and Port 3 I/O lines P30 (input) and P37 (output). Counter/Timer T0 provides the clock input for control of the data rates. Internal Data Bus Read FOH IRQ4 Stop Bit Detect Receiver Buffer P30 Serial In Transfer Write FOH Receiver Shift Register Start Bit Detect Transmitter Shift Register Char Detect Shift Clock Mark P37 Shift Clock RESET ÷16 Parity Check Serial Out Parity Gan Start Clock Control ÷6 IRQ3 Stop Serial I/O Clock (From T0) Figure 105. UART Block Diagram UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 166 Configuration of the UART is controlled by the Port 3 Mode Register (P3M) located at address F7h. the Z8® CPU always transmits eight bits between the start and stop bits (eight Data Bits or seven Data Bits and one Parity Bit). Odd parity generation and detection is supported. The SIO Register and its associated Mode Control Registers are mapped into the Standard Z8 Register File as shown in Table 23. The organization allows the software to access the UART as general-purpose registers, eliminating the requirement for special instructions. Table 23. UART Register Map Register Name Identifier Hex Address Port 3 Mode P3M F7 T0 Prescaler PRE0 F5 T0 F4 Timer Mode TMR F1 UART SIO F0 Timer/Counter0 UART Bit-Rate Generation When Port 3 Mode Register bit 6 is set to 1, the UART is enabled and T0 automatically becomes the bit rate generator (see Figure 106). The endof-count signal of T0 no longer generates Interrupt Request IRQ4. Instead, the signal is used as the input to the divide-by-16 counters (one each for the receiver and the transmitter) that clock the data stream. Serial Input/Output UM001602-0904 Z8 CPU User Manual 167 Register F7h Port 3 Mode Register (P3M) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 0 P30 Input and P37 = Output 1 P30 Serial In and P37 = Serial Out Figure 106. Port 3 Mode Register and Bit-Rate Generation The divide chain that generates the bit rate is shown in Figure 107. The bit rate is given by the following equation: Bit Rate = XTAL Frequency ÷ (2 x 4 x p x t x 16) where p and t are the initial values in Prescaler0 and Counter/Timer0, respectively. The final divide-by-16 is required because T0 runs at 16 times the bit rate in order to synchronize on the incoming data. fXTAL ÷2 ÷4 P t PRE0 T0 ÷16 Bit Rate Clock Figure 107. Bit Rate Divide Chain To configure the Z8® CPU for a specific bit rate, appropriate values as determined by the above equation must be loaded into registers PRE0 (F5h) and T0 (F4h). PRE0 also controls the counting mode for T0 and should therefore be set to CONTINUOUS mode (D0 = 1). For example, given an input clock frequency (XTAL) of 11.9808 MHz and a selected bit rate of 1200 bits per second, the equation is satisfied by UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 168 p = 39 and t = 2. Counter/Timer T0 should be set to 02h. With T0 in Continuous Mode, the value of PRE0 becomes 9Dh (see Figure 108). Table 24 lists several commonly used bit rates and the values of XTAL, p, and t required to derive them. This list is presented for convenience and is not intended to be exhaustive. Table 24. Bit Rates 7,3728 7,9872 9,8304 11,0592 11,6736 11,9808 12,2880 Bit Rate p t p t p t p t p t p t p t 19200 3 1 – – 4 1 – – – – – – 5 1 9600 3 2 – – 4 2 9 1 – – – – 5 2 4800 3 4 13 1 4 4 9 2 19 1 – – 5 4 2400 3 8 13 2 4 8 9 4 19 2 39 1 5 8 1200 3 16 13 4 4 16 9 8 19 4 39 2 5 16 600 3 32 13 8 4 32 9 16 19 8 39 4 5 32 300 3 64 13 16 4 64 9 32 19 16 39 8 5 64 150 3 128 13 32 4 128 9 64 19 32 39 16 5 128 110 3 175 3 189 4 175 5 157 4 207 17 50 8 109 Serial Input/Output UM001602-0904 Z8 CPU User Manual 169 Register F5h Prescalar 0 Register (PRE0) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Count Mode 0 = T0 Single Pass 1 = T0 Modulo-n (Range: 1-64 decimal, 01h–00h) (Range: 1-64) Figure 108. Prescaler 0 Register Bit-Rate Generation The bit rate generator is started by setting the Timer Mode Register (TMR) (F1h) bit 1 and bit 0 both to 1 (see Figure 109). This transfers the contents of the Prescaler 0 Register and Counter/Timer0 Register to their corresponding down counters. In addition, counting is enabled so that UART operations begin. Register F1h Timer Mode Register (TMR) (Read/Write) D7 D6 D5 D4 D3 D2 D1 D0 0 = No Function 1 = Load T0 0 = Disable T0 Count 1 = Enable T0 Count Figure 109. Timer Mode Register Bit Rate Generation UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 170 UART Receiver Operation The receiver consists of a receiver buffer (SIO Register [F0h]), a serial-in, parallel-out shift register, parity checking, and data synchronizing logic. The receiver block diagram is shown as part of Figure 105 on page 165. Receiver Shift Register After a hardware reset or after a character has been received, the Receiver Shift Register is initialized to all 1s and the shift clock is stopped. Serial data, input through Port 3 bit 0, is synchronized to the internal clock by two D-type flip-flops before being input to the Shift Register and the start bit detection circuitry. The start bit detection circuitry monitors the incoming data stream, looking for a start bit (a High-to-Low input transition). When a start bit is detected, the shift clock logic is enabled. The T0 input is divided-by-16 and, when the count equals eight, the divider outputs a shift clock. This clock shifts the start bit into the Receiver Shift Register at the center of the bit time. Before the shift actually occurs, the input is rechecked to ensure that the start bit is valid. If the detected start bit is false, the receiver is reset and the process of looking for a start bit is repeated. If the start bit is valid, the data is shifted into the Shift Register every sixteen counts until a full character is assembled (see Figure 110). Serial Input/Output UM001602-0904 Z8 CPU User Manual 171 Start Bit Transition Detected (R) RCVR Data Shift Clock Stop Bit One or More Eight T0 Counts Later Shifting Starts RCVR IRQ3 Shift register Contents Transferred to Receive Buffer and IRQ3 is Generated Figure 110. Receiver Timing After a full character has been assembled in the receiver’s buffer, SIO Register (F0h), Interrupt Request IRQ3 is generated. The shift clock is stopped and the Shift Register reset to all 1s. The start bit detection circuitry begins monitoring the data input for the next start bit. This cycle allows the receiver to synchronize on the center of the bit time for each incoming character. Overwrites Although the receiver is single buffered, it is not protected from being overwritten, so the software must read the SIO Register (F0h) within one character time after the interrupt request (IRQ3). the Z8® CPU does not have a flag to indicate this overrun condition. If polling is used, the IRQ3 bit in the Interrupt Request Register must be reset by software. Framing Errors Framing error detection is not supported by the receiver hardware, but by responding to the interrupt request within one character bit time, the software can test for a stop bit on P30. Port 3 bits are always readable, which UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 172 facilitates break detection. For example, if a null character is received, testing P30 results in a 0 being read. Parity The data format supported by the receiver must have a start bit, eight data bits, and at least one stop bit. If parity is on, bit 7 of the data received will be replaced by a Parity Error Flag. A parity error sets bit 7 to 1, otherwise, bit D7 is set to 0. Figure 111 shows these data formats. Received Data (No Parity) SP D7 D6 D5 D4 D3 D2 D1 D0 ST Start Bit Eight Data Bits One Stop Bit Received Data (With Parity) SP P D6 D5 D4 D3 D2 D1 D0 ST Start Bit Seven Data Bits Parity Error Flag One Stop Bit Figure 111. Receiver Data Formats The Z8® CPU hardware supports odd parity only, that is enabled by setting the Port 3 Mode Register bit 7 to 1 (see Figure 112). If even parity is required, PARITY mode should be disabled (P3M bit 7 set to 0), and software must calculate the received data’s parity. Serial Input/Output UM001602-0904 Z8 CPU User Manual 173 Register F7h Port 3 Mode Register (P3M) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 0 = Parity OFF 1 = Parity ON Figure 112. Port 3 Mode Register Parity Transmitter Operation The transmitter consists of a transmitter buffer (SIO Register [F0h]), a parity generator, and associated control logic. The transmitter block diagram is shown as part of Figure 105 on page 165. After a hardware reset or after a character has been transmitted, the transmitter is forced to a marking state (output always High) until a character is loaded into the transmitter buffer, SIO Register (F0h). The transmitter is loaded by specifying the SIO Register as the destination register of any instruction. T0’s output drives a divide-by-16 counter that in turn generates a shift clock every 16 counts. This counter is reset when the transmitter buffer is written by an instruction. This reset synchronizes the shift clock to the software. The transmitter then outputs one bit per shift clock, through Port 3 bit 7, until a start bit, the character written to the buffer, and two stop bits have been transmitted. After the second stop bit has been transmitted, the output is again forced to a marking state. Interrupt request IRQ4 is generated at this time to notify the processor that the transmitter is ready to accept another character. UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 174 Overwrites The user is not protected from overwriting the transmitter, so it is up to the software to respond to IRQ4 appropriately. If polling is used, the IRQ4 bit in the Interrupt Request Register must be reset. Parity The data format supported by the transmitter has a start bit, eight data bits, and at least two stop bits. If parity is on, bit 7 of the data transmitted will be replaced by an odd parity bit. Figure 113 shows the transmitter data formats. Parity is enabled by setting Port 3 Mode Register bit 7 to 1. If even parity is required, PARITY mode should be disabled (P3M bit 7 reset to 0), and software must modify the data to include even parity. Because the transmitter can be overwritten, the user is able to generate a break signal. This is done by writing null characters to the transmitter buffer (SIO Register [F0h]) at a rate that does not allow the stop bits to be output. Each time the SIO Register is loaded, the divide-by-16 counter is resynchronized and a new start bit is output followed by data. Serial Input/Output UM001602-0904 Z8 CPU User Manual 175 Transmitted Data (No Parity) SP SP D7 D6 D5 D4 D3 D2 D1 D0 ST Start Bit Eight Data Bits Two Stop Bit Transmitted Data (With Parity) SP SP P D6 D5 D4 D3 D2 D1 D0 ST Start Bit Seven Data Bits Odd Parity Two Stop Bit Figure 113. Transmitter Data Formats UART Reset Conditions After a hardware reset, the SIO Register contents are undefined, and Serial Mode and parity are disabled. Figures 114 and 115 show the binary reset values of the SIO Register and its associated mode register P3M. Register RF0h Serial I/O Register (SIO) (Read/Write) U U U U U U U U Serial Data (D0 = LSB) Figure 114. SIO Register Reset UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 176 Register F7h Port 3 Mode Register (P3M) (Write-Only) 0 0 0 0 0 0 0 0 0 Port 2 Pull-Ups Open-Drain 1 Port 2 Pull-Ups Active 0 P32 = Input 1 P32 = DAV0/RDY0 P35 = Output P35 = RDY0/DAV0 00 01 10 11 P34 = Output P34 = DM P34 = DM P34 = RDY1/DAV1 P33 = Input P33 = Input P33 = Input P33 = DAV1/RDY1 0 P31 = Input (TIN) 1 P32 = DAV2/RDY2 P36 = Output (TOUT) P36 = RDY2/DAV2 0 P30 = Input 1 P30 = Serial In P37 = Output P37 = Serial Out 0 Parity ON 1 Parity OFF Figure 115. P3M Register Reset Serial Peripheral Interface Select Z8 microcontrollers incorporate a Serial Peripheral Interface (SPI) for communication with other microcontrollers and peripherals. The SPI includes features such as Stop-Mode Recovery, Master/Slave selection, and Compare mode. Table 25 contains the pin configuration for the SPI feature when it is enabled. The SPI consists of four registers: SPI Control Register (SCON), SPI Compare Register (SCOMP), SPI Receive/Buffer Register (RxBUF), and SPI Shift Register. SCON is located in bank (C) of the Expanded Register File at address 02. Serial Input/Output UM001602-0904 Z8 CPU User Manual 177 Table 25. SPI Pin Configuration Name Function Pin Location DI Data-In P20 DO Data-Out P27 SS Slave Select P35 SK SPI Clock P34 The SPI Control Register (SCON; see Figure 116), is a read/write register that controls Master/Slave selection, interrupts, clock source and phase selection, and error flag. Bit 0 enables/disables the SPI with the default being SPI disabled. A 1 in this location will enable the SPI, and a 0 will disable the SPI. Bits 1 and 2 of the SCON register in Master Mode select the clock rate. The user may choose whether internal clock is divide-by-2, 4, 8, or 16. In Slave Mode, Bit 1 of this register flags the user if an overrun of the RxBUF Register has occurred. The RxCharOverrun flag is only reset by writing a 0 to this bit. In slave mode, bit 2 of the Control Register disables the data-out I/O function. If a 1 is written to this bit, the data-out pin is released to its original port configuration. If a 0 is written to this bit, the SPI shifts out one bit for each bit received. Bit 3 of the SCON Register enables the compare feature of the SPI, with the default being disabled. When the compare feature is enabled, a comparison of the value in the SCOMP Register is made with the value in the RxBUF Register. Bit 4 signals that a receive character is available in the RxBUF Register. UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 178 SCON (C) 02 D7 D6 D5 D4 D3 D2 D1 D0 SPI Enable 0 Disable * 1 Enable RxCharOverrun (S) 0 Reset 1 Overrun CLK Divide (M) 00 TCLK/2 01 TCLK/4 10 TCLK/8 11 TCLK/16 DO SPI Port Enable (S) 0 SPI DO Port Enable 1 Do Port to I/O Compare Enable 0 Enable 1 Disable * RxCharAvail 0 Reset 1 Char. Avail Clock Phase 0 Trans/Fall 1 Trans/Rise CLK Source 0 TCLK 1 Timer 0 Output (S) Used with Bit D7 equal to 0 (M) Used with Bit D7 equal to 1 Master Slave 0 Slave 1 Master * Default setting after Reset Figure 116. SPI Control Register Serial Input/Output UM001602-0904 Z8 CPU User Manual 179 If the associated IRQ3 is enabled, an interrupt is generated. Bit 5 controls the clock phase of the SPI. A 1 in bit 5 allows for receiving data on the clock’s falling edge and transmitting data on the clock’s rising edge. A 0 allows receiving data on the clock’s rising edge and transmitting on the clock’s falling edge. The SPI clock source is defined in bit 6. A 1 uses Timer0 output for the SPI clock, and a 0 uses TCLK for clocking the SPI. Finally, bit 7 determines whether the SPI is used as a Master or a Slave. A 1 puts the SPI into Master mode and a 0 puts the SPI into Slave mode. SPI Operation The SPI is used in one of two modes: either as system slave, or as system master. Several of the possible system configurations are shown in Figure 117. In slave mode, data transfer starts when the slave select (SS) pin goes active. Data is transferred into the slave’s SPI Shift Register through the DI pin, which has the same address as the RxBUF Register. After a byte of data has been received by the SPI Shift Register, a Receive Character Available (RCA/IRQ3) flag and interrupt is generated. The next byte of data will be received at this time. The RxBUF Register must be cleared, or a Receive Character Overrun (RxCharOverrun) flag will be set in the SCON Register, and the data in the RxBUF Register will be overwritten. When the communication between the master and slave is complete, the SS goes inactive.When the SPI is activated as a slave, it operates in all system modes: STOP, HALT, and RUN. Unless disconnected, for every bit that is transferred into the slave through the DI pin, a bit is transferred out through the D0 pin on the opposite clock edge. During slave operation, the SPI clock pin (SK) is an input. In master mode, the CPU must first activate a SS through one of its I/O ports. Next, data is transferred through the master’s D0 pin one bit per master clock cycle. Loading data into the shift register initiates the transfer. In master mode, the master’s clock will drive the slave’s clock. At the conclusion of a transfer, a Receive Character Available (RCA/IRQ3) flag UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 180 and interrupt is generated. Before data is transferred via the D0 pin, the SPI Enable bit in the SCON Register must be enabled. SPI Compare When the SPI Compare Enable bit, D3 of the SCON Register is set to 1, the SPI Compare feature is enabled. The compare feature is only valid for slave mode. A compare transaction begins when the (SS) line goes active. Data is received as if it were a normal transaction, but there is no data transmitted to avoid bus contention with other slave devices. When the compare byte is received, IRQ3 is not generated. Instead, the data is compared with the contents of the SCOMP Register. If the data does not match, DO remains inactive and the slave ignores all data until the (SS) signal is reset. If the data received matches the data in the SCOMP register, then a SMR signal is generated. DO is activated if it is not tri-stated by D2 in the SCON Register, and data is received the same as any other SPI slave transaction. Slaves’ not comparing remain in their current mode, whereas slaves’ comparing wake from a STOP mode by means of an SMR SPI Clock The SPI clock maybe driven by three sources: Timer0, a division of the internal system clock, or the external master when in slave mode. Bit D6 of the SCON Register controls what source drives the SPI clock. A 0 in bit D6 of the SCON Register determines the division of the internal system clock if this is used as the SPI clock source. Divide by 2, 4, 8, or 16 is chosen as the scaler. Serial Input/Output UM001602-0904 Z8 CPU User Manual 181 Standard Serial Setup ss sk Master do di ss sk do di Slave ss sk do di ss sk do di ss sk do di Slave Slave Slave ss sk do di ss sk do di ss sk do di ss sk do di Slave Slave Slave Slave ss sk do di ss sk do di ss sk do di ss sk do di Slave Slave Slave Standard Parallel Setup ss1 ss2 ss3 Master ss4 sk do di Setup For Compare ss sk Master do di (1) Three Wire Compare Setup (2) (255) Up to 256 slaves per SS line Slave (256) ss sk Master do di ss sk do di ss sk do di ss sk do di ss sk do di Slave Slave Slave Slave Multiple slaves may have the same address Figure 117. SPI System Configuration UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 182 Receive Character Available and Overrun When a complete data stream is received, an interrupt is generated and the RxCharAvail bit in the SCON Register is set. Bit 4 in the SCON Register is for enabling or disabling the RxCharAvail interrupt. The RxCharAvail bit is available for interrupt polling purposes and is reset when the RxBUF Register is read. RxCharAvail is generated in both master and slave modes. While in slave mode, if the RxBUF is not read before the next data stream is received and loaded into the RxBUF Register, Receive Character Overrun (RxCharOverrun) occurs. Because there is no requirement for clock control in slave mode, bit D1 in the SPI Control Register is used to log any RxCharOverrun (see Figures 118 and 119). TSK SK 3 SS 2 4 D0 1 DI 5 Figure 118. SPI Timing Serial Input/Output UM001602-0904 Z8 CPU User Manual 183 SK D0 Port Control SMR Bit Control /Interrupt Control DI SPI Compare Register (SCOMP) SS SPI Shift Register SPI Receive Buffer (RxBUF) SPI Control IRQ3 SPI Clock TCLK SCLK + n Figure 119. SPI Logic UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 184 OPEN-DRAIN P20 OE SPI EN P20 PIN P20 IN or SPI DI Autolatch R ≈ 500 KΩ OPEN-DRAIN Standard P27 OUT SPI SPI DO P27 PIN Standard P27 OE SPI SPI Active SCON D2 0 SOI D0 Enable 1 P27 OUT *SPI must be enabled with D0 P27 IN Autolatch R ≈ 500 KΩ Figure 120. SPI Data In/Out Configuration Serial Input/Output UM001602-0904 Z8 CPU User Manual 185 SK IN SPI EN SPI MSTR P34 PIN SPI EN SK OUT P34 OUT P31 MUX + SS REF SPI EN SPI MSTR P35 PIN P35 OUT P32 + REF PCON D0 0 P34, P35 Standard Output 1 P34, P35 Comparator Output Figure 121. SPI Clock/SPI Slave Select Output Configuration UM001602-0904 Serial Input/Output Z8 Family of Microcontrollers User Manual 186 Serial Input/Output UM001602-0904 Z8 CPU User Manual 187 External Interface Introduction The Z8® CPU can be a microcontroller with 20 pins for external memory interfacing. The external memory interface on the Z8® CPU is generally for either RAM or ROM; this features is only available for devices featuring Port 0, Port 1, R/W, DM, AS, and DS. Please refer to specific product specifications for availability of these features. The Z8® CPU offers a multiplexed external memory interface. In multiplexed mode, eight pins from Port 1 form an Address/Data Bus (AD7– AD0), eight pins from Port 0 form a High Address Bus (A15–A8). Three additional pins provide the Address Strobe, Data Strobe, and the Read/ Write Signal. Figure 122 shows the Z8® CPU external interface pins. (Port 1) AD7–AD0 (Port 0) AD15–AD8 Z8 CPU AS External Program/Data 64KB Each DS R/W DM Figure 122. Z8® CPU External Interface Pins UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 188 Pin Descriptions The following sections briefly describe the pins associated with the Z8® CPU external memory interface. Address Strobe (output, active Low). Address Strobe (AS) is pulsed Low once at the beginning of each machine cycle. The rising edge of AS indicates the address, Read/Write (R/W), and data memory (DM) signals are valid for program or data memory transfers. In some cases, the Z8® CPU address strobe is pulsed low regardless of accessing external or internal memory. Please refer to specific product specifications for AS operation. Data Strobe (Output, Active Low). Data Strobe (DS) provides the timing for data movement to or from the Address/Data bus for each external memory transfer. During a Write Cycle, data out is valid at the leading edge of the DS. During a Read Cycle, data in must be valid prior to the trailing edge of the DS. Read/Write (Output). Read/Write (R/W) determines the direction of data transfer for memory transactions. R/W is Low when writing to program or data memory, and High for all other transactions. Data Memory (Output). Data memory (DM) provides a signal to separate external program memory from external data memory. It is a programmable function on pin P34. Data memory is active low for external data memory accesses and high for external program memory accesses. High Address Lines A15–A8. A15–A8 provide the High Address lines for the memory interface. The Port 0–1 mode registers must have bits D7 and D1 set equal to 1 to configure Port 0 as A15–A8. Outputs can be CMOS- or TTL-compatible. Please refer to product specifications for actual type. See Figure 123. Address/Data Lines AD7–AD0. AD7–AD0 is a multiplexed Address/ Data memory interface. The lower eight Address lines (A7–A0) are multiplexed with Data lines (D7–D0). Port 0–1 mode registers must have bits External Interface UM001602-0904 Z8 CPU User Manual 189 D4 set equal to 1 and D3 set equal to 0 to configure Port 1 as AD7–AD0. Inputs and outputs are TTL-compatible. See Figure 123. Reset. RESET (input, active Low) initializes the Z8® CPU. When RESET is deactivated, program execution begins from program location 000Ch. If held Low, RESET acts as a register file protect during powerdown and power-up sequences. To avoid asynchronous and noisy reset problems, the Z8® CPU is equipped with a reset filter of four external clocks (4TPC). If the external RESET signal is less than 4TPC in duration, no reset will occur. On the fifth clock after the RESET is detected, an internal reset signal is latched and held for an internal register count of 18 or more external clocks, or for the duration of the external RESET, whichever is longer. Please refer to specific product specifications for length of reset delay time. Crystal1, Crystal2 (Oscillator Input and Output). These pins connect a parallel-resonant crystal, ceramic resonator, LC, RC network, or external single-phase clock to the on-chip oscillator input. Please refer to the device product specifications for information on availability of RC oscillator features. External Addressing Configuration The minimum bus configuration uses Port 1 as a multiplexed address/data port (AD7–AD0), allowing access to 256 bytes of external memory. In this configuration, the eight low-order bits (A0–A7) are multiplexed with the data (D7–D0). Port 0 can be programmed to provide either four additional address lines (A11–A8), which increases the addressable memory to 4 KB, or eight additional address lines (A15–A8), which increases the addressable external memory up to 64 KB. It is required to add a NOP after configuring Port 0/Port 1 for external addressing before jumping to external memory execution. UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 190 Register F8h (P01M) Port 0–1 Mode Register (P01M) (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 P00–P07 Mode 00 = Output 01 = Input 1X = A8–A11 P10–P17 Mode 00 = Byte Output 01 = Byte Output 10 = AD0-AD7 11 = High Impedance AD0–AD7, A8–A15, AS, DS, R/W P04–P07 Mode 00 = Output 01 = Input 1X = A12–A15 Figure 123. External Address Configuration External Stacks The Z8® CPU architecture supports stack operations in either the Z8® Standard Register File or external data memory. A stack’s location is determined by bit 2 in the Port 0–1 Mode Register (F8h). If bit 2 is set to 0, the stack is in external data memory (see Figure 124). The instruction used to change the stack selection bit should not be immediately followed by the instructions RET or IRET, because this will cause indeterminate program flow. After a RESET, the internal stack is selected. External Interface UM001602-0904 Z8 CPU User Manual 191 Please note that if Port 0 is configured as A15–A8 and the stack is selected as internal, any stack operation will cause the contents in register FEh to be displayed on Port 0. Register F8h (P01M) Port 0–1 Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Z8 Stack Selection 0 = External 1 = Internal Figure 124. Z8 Stack Selection Data Memory The two Z8 external memory spaces, data and program, are addressed as two separate spaces of up to 64 KB each. External program memory and external data memory are logically selected by the data memory select output (DM). DM is made available on Port 3, bit 4 (P34) by setting bit 4 and bit 3 in the Port 3 Mode Register (F7h) to 10 or 01 (see Figure 125). DM is active Low during the execution of the LDE, LDEI instructions, and High for the execution of program instructions. DM is also active Low during the execution of CALL, POP, PUSH, RET and IRET instructions if the stack resides in external data memory. After a RESET, DM is not selected. UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 192 Register F7h (P3M) Port 3 Mode Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 Bits 00 01 10 11 Configuration P33 = Input P33 = Input P33 = Input P33 = DAV1/RDY1 P34 = Output P34 = DM P34 = DM P34 = RDY1/DAV1 Figure 125. Port 3 Data Memory Operation Bus Operation Typical data transfers between the Z8® CPU and external memory are illustrated in Figures 126 and 127. Machine cycles can vary from six to 12 clock periods depending on the operation being performed. The notations used to describe the basic timing periods of the Z8® CPU are machine cycles (Mn), timing states (Tn), and clock periods. All timing references are made with respect to the output signals AS and DS. The clock is shown for clarity only and does not have a specific timing relationship with other signals. External Interface UM001602-0904 Z8 CPU User Manual 193 Machine Cycle T1 T2* T3 Clock A15-A8 A8-A15 AD7–AD0 A7–A0 D7–D0 IN AS DS R/W DM Read Cycle *Port inputs are strobed during T2, which is two internal systems clocks before the execution cycle of the current instruction. Figure 126. External Instruction Fetch or Memory Read Cycle UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 194 Machine Cycle T1 T3 T2 Clock A15-A8 A8-A15 AD7–AD0 A7–A0 D7–D0 OUT AS DS R/W DM Write Cycle Figure 127. External Memory Write Cycle Address Strobe All transactions start with AS driven Low and then raised High by the Z8® CPU. The rising edge of AS indicates that R/W, DM (if used), and the address outputs are valid. The address outputs (AD7–AD0), remain valid only during MnT1 and typically must be latched using AS. Address External Interface UM001602-0904 Z8 CPU User Manual 195 outputs (A15–A8) remain stable throughout the machine cycle, regardless of the addressing mode. Data Strobe The Z8® CPU uses DS to time the actual data transfer. For Write operations (R/W = Low), a Low on DS indicates that valid data is on the AD7– AD0 lines. For Read operations (R/W = High), the bus is placed in a highimpedance state before driving DS Low, so the addressed device can put its data on the bus. The Z8® CPU samples this data prior to raising DS High. Extended Bus Timing Some products can accommodate slow memory access time by automatically inserting an additional software controlled state time (Tx). This stretches the DS timing by two clock periods. Figures 128 and 129 illustrate extended external memory Read and Write cycles. UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 196 Machine Cycle T1 T2* TX T3 Clock A15-A8 AD7–AD0 A15-A8 A7–A0 D7–D0 IN AS DS R/W DM Read Cycle *Port inputs are strobed during T2, which is two internal system clocks before the execution of the current instruction. Figure 128. Extended External Instruction Fetch or Memory Read Cycle External Interface UM001602-0904 Z8 CPU User Manual 197 Machine Cycle T1 T2 TX T3 Clock A15-A8 AD7–AD0 A15–A8 A7–A0 D7–D0 OUT AS DS R/W DM Write Cycle Figure 129. Extended External Memory Write Cycle Timing is extended by setting bit D5 in the Port 0–1 Mode Register (F8h) to 1 (see Figure 130). After a RESET, this bit is set to 0. UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 198 Register F8h (P01M) Port 0–1 Register (Write-Only) D7 D6 D5 D4 D3 D2 D1 D0 External Memory Timing 0 = Normal 1 = Extended Figure 130. Extended Bus Timing Instruction Timing The High throughput of the Z8® CPU is due, in part, to the use of an instruction pipeline, in which the instruction fetch and execution cycles are overlapped. During the execution of the current instruction, the opcode of the next instruction is fetched. Instruction pipelining is illustrated in Figure 131. Figures 131 and 132 show typical instruction cycle timing for instructions fetched from memory. For those instructions that require execution time longer than that of the overlapped fetch, or reference program or data memory as part of their execution, the pipe must be flushed. Figures 131 and 132 assume the XTAL ÷ 2 clock mode is selected. External Interface UM001602-0904 Z8 CPU User Manual 199 M1 T1 T3 T2 T1 M2 T2 T3 T1 M3 T2 T3 Clock A15–A8 A15–A8 A7–A0 A7–A0 A15–A8 A7–A0 A7–A0 A7–A0 AS DS R/W Fetch 1st Byte Fetch 1st Byte Of Next Instruction * Port inputs are strobed during T2, which is two internal system clocks before the execution cycle of the current installation Figure 131. Instruction Cycle Timing (1-Byte Instructions) UM001602-0904 External Interface Z8 Family of Microcontrollers User Manual 200 M1 T1 T3 T2 T1 M2 T2 T3 T1 M3 T2 T3 Clock A15–A8 A15–A8 A15–A8 A7–A0 A7–A0 A7–A0 A7–A0 A15–A8 A7–A0 A7–A0 A7–A0 AS DS R/W Fetch 1st Byte Fetch 2nd Byte Fetch 3rd Byte (3-Byte Instruction) Fetch 1st Byte (1- or 2-Byte Instruction) *Port inputs are strobed during T2, which is two internal system clocks before the execution cycle of the current instruction. Figure 132. Instruction Cycle Timing (2- and 3-Byte Instructions) Z8 Reset Conditions After a hardware reset, extended timing is set to accommodate slow memory access during the configuration routine, DM is inactive, the stack resides in the register file. Port 0, 1, and 2 are reset to input mode. Port 2 is set to Open-Drain Mode. External Interface UM001602-0904 Z8 CPU User Manual 201 Instruction Set Z8 instructions can be divided functionally into the following eight groups: • • • • • • • • Load Bit Manipulation Arithmetic Block Transfer Logical Rotate and Shift Program Control CPU Control The following summary shows the instructions belonging to each group and the number of operands required for each. The source operand is src, the destination operand is dst, and a condition code is cc. Table 26. Load Instructions UM001602-0904 Mnemonic Operands Instruction CLR dst Clear LD dst, src Load LDC dst, src Load Constant LDE dst, src Load External POP dst Pop PUSH src Push Instruction Set Z8 Family of Microcontrollers User Manual 202 Table 27. Arithmetic Instructions Mnemonic Operands Instruction ADC dst, src Add with Carry ADD dst, src Add CP dst, src Compare DA dst Decimal Adjust DEC dst Decrement DECW dst Decrement Word INC dst Increment INCW dst Increment Word SBC dst, src Subtract with Carry SUB dst, src Subtract Table 28. Logical Instructions Mnemonic Operands Instruction AND dst, src Logical AND COM dst Complement OR dst, src Logical OR XOR dst, src Logical Exclusive OR Table 29. Program Control Instructions Instruction Set Mnemonic Operands Instruction CALL dst Call Procedure DJNZ dst, src Decrement and Jump Non-Zero UM001602-0904 Z8 CPU User Manual 203 Table 29. Program Control Instructions (Continued) Mnemonic Operands IRET Instruction Interrupt Return JP cc, dst Jump JR cc, dst Jump Relative RET Return Table 30. Bit Manipulation Instructions Mnemonic Operands Instruction TCM dst, src Test Complement Under Mask TM dst, src Test Under Mask AND dst, src Bit Clear OR dst, src Bit Set XOR dst, src Bit Complement Table 31. Block Transfer Instructions UM001602-0904 Mnemonic Operands Instruction LDCI dst, src Load Constant Auto Increment LDEI dst, src Load External Auto Increment Instruction Set Z8 Family of Microcontrollers User Manual 204 Table 32. Rotate and Shift Instructions Mnemonic Operands Instruction RL dst Rotate Left RLC dst Rotate Left Through Carry RR dst Rotate Right RRC dst Rotate Right Through Carry SRA dst Shift Right Arithmetic SWAP dst Swap Nibbles Table 33. CPU Control Instructions Mnemonic Instruction CCF Complement Carry Flag DI Disable Interrupts EI Enable Interrupts HALT Halt NOP No Operation RCF Reset Carry Flag SCF Set Carry Flag SRP Instruction Set Operands src Set Register Pointer STOP Stop WDh WDT Enable During HALT WDT WDT Enable or Refresh UM001602-0904 Z8 CPU User Manual 205 Processor Flags The Flag Register (FCh) informs the user of the current status of the Z8® CPU. The flags and their bit positions in the Flag Register are shown in Figure 133. The Z8® Flag Register contains six bits of status information which are set or cleared by CPU operations. Four of the bits (C, V, Z and S) can be tested for use with conditional Jump instructions. Two flags (H and D) cannot be tested and are used for BCD arithmetic. The two remaining bits in the Flag Register (F1 and F2) are available to the user, but they must be set or cleared by instructions and are not usable with conditional Jumps. As with bits in the other control registers, the Flag Register bits can be set or reset by instructions; however, only those instructions that do not affect the flags as an outcome of the execution should be used (Load Immediate). Note: The Watch–Dog Timer (WDT) instruction affects the Flags accordingly: Z = 1, S = 0, V = 0. Register FCh (Flags) Flag Register (Read/Write) D7 D6 D5 D4 D3 D2 D1 D0 User Flag (F1) User Flag (F2) Half Carry Flag (H) Decimal Adjust Flag (D) Overflow Flag (V) Sign Flag (S) Zero Flag (Z) Carry Flag (C) Figure 133. Z8 Flag Register UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 206 Carry Flag The Carry Flag (C) is set to 1 whenever the result of an arithmetic operation generates a carry or a borrow the high order bit 7. Otherwise, the Carry Flag is cleared to 0. Following Rotate and Shift instructions, the Carry Flag contains the last value shifted out of the specified register. An instruction can set, reset, or complement the Carry Flag. IRET may change the value of the Carry Flag when the Flag Register, saved in the Stack, is restored. Zero Flag For arithmetic and logical operations, the Zero Flag (Z) is set to 1 if the result is zero. Otherwise, the Zero Flag is cleared to 0. If the result of testing bits in a register is 00h, the Zero Flag is set to 1. Otherwise the Zero Flag is cleared to 0. If the result of a Rotate or Shift operation is 00h, the Zero Flag is set to 1. Otherwise, the Zero Flag is cleared to 0. IRET changes the value of the Zero Flag when the Flag Register saved in the Stack is restored. The WDT Instruction sets the Zero Flag to a 1. Sign Flag The Sign Flag (S) stores the value of the most significant bit of a result following an arithmetic, logical, Rotate, or Shift operation. When performing arithmetic operations on signed numbers, binary two’scomplement notation is used to represent and process information. A positive number is identified by a 0 in the most significant bit position (bit 7); therefore, the Sign Flag is also 0. A negative number is identified by a 1 in the most significant bit position (bit 7); therefore, the Sign Flag is also 1. Instruction Set UM001602-0904 Z8 CPU User Manual 207 IRET changes the value of the Sign Flag when the Flag Register saved in the Stack is restored. Overflow Flag For signed arithmetic, Rotate, and Shift operations, the Overflow Flag (V) is set to 1 when the result is greater than the maximum possible number (> 127) or less than the minimum possible number (< –128) that can be represented in two’s-complement form. The Overflow Flag is set to 0 if no overflow occurs. Following logical operations the Overflow Flag is set to 0. IRET changes the value of the Overflow Flag when the Flag Register saved in the Stack is restored. Decimal Adjust Flag The Decimal Adjust Flag (D) is used for BCD arithmetic. Because the algorithm for correcting BCD operations is different for addition and subtraction, this flag specifies what type of instruction was last executed so that the subsequent Decimal Adjust (DA) operation can function properly. Normally, the Decimal Adjust Flag cannot be used as a test condition. After a subtraction, the Decimal Adjust Flag is set to 1. Following an addition it is cleared to 0. IRET changes the value of the Decimal Adjust Flag when the Flag Register saved in the Stack is restored. Half Carry Flag The Half Carry Flag (H) is set to 1 whenever an addition generates a carry bit 3 (Overflow) or a subtraction generates a borrow bit 3. The Half Carry Flag is used by the Decimal Adjust (DA) instruction to convert the binary result of a previous addition or subtraction into the correct decimal (BCD) result. As in the case of the Decimal Adjust Flag, the user does not normally access this flag. UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 208 IRET changes the value of the Half Carry Flag when the Flag Register saved in the Stack is restored. Condition Codes The C, Z, S, and V Flags control the operation of the ‘Conditional’ Jump instructions. Sixteen frequently useful functions of the flag settings are encoded in a 4-bit field called the condition code (cc), which forms bits 47 of the conditional instructions. Table 34. Z8 Flag Definitions Flag Description C Carry Flag Z Zero Flag S Sign Flag V Overflow Flag D Decimal Adjust Flag H Half Carry Flag Condition codes and flag settings are summarized in Tables 34 through 36. Notation for the flags and how they are affected are as follows: Table 35. Flag Settings Definitions Instruction Set Symbol Definition 0 Cleared to 0 1 Set to 1 * Set or cleared according to operation – Unaffected X Undefined UM001602-0904 Z8 CPU User Manual 209 Table 36. Condition Codes Binary Hex Mnemonic Definition Flag Settings 0000 0 F Always False — 1000 8 (blank) Always True — 0111 7 C Carry C=1 1111 F NC No Carry C=0 0110 6 Z Zero Z=1 1110 E NZ Non-Zero Z=0 1101 D PL Plus S=0 0101 5 Ml Minus S=1 0100 4 OV Overflow V=1 1100 C NOV No Overflow V=0 0110 6 EQ Equal Z=1 1110 E NE Not Equal Z=0 1001 9 GE Greater Than or Equal (S XOR V) = 0 0001 1 LT Less Than (S XOR V) = 1 1010 A GT Greater Than (Z OR (S XOR V)) = 0 0010 2 LE Less Than or Equal (Z OR (S XOR V)) = 1 1111 F UGE Unsigned Greater Than or Equal C=0 0111 7 ULT Unsigned Less Than C=1 1011 B UGT Unsigned Greater Than (C = 0 AND Z = 0) = 1 0011 3 ULE Unsigned Less Than or Equal (C OR Z) = 1 UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 210 Notation and Binary Encoding In the detailed instruction descriptions that make up the rest of this chapter, operands and status flags are represented by a notational shorthand. Operands, condition codes, address modes, and their notations are as follows (Table 37). Table 37. Notational Shorthand Notation Address Mode cc Condition Code r Working Register Rn n = 0–15 R Register Reg Reg. represents a number in the range of 00h to FFh or Working Register Rn n = 0–15 Register Pair Reg Reg. represents an even number in the range of 00h to FEh RRp p = 0, 2, 4, 6, 8, 10, 12, or 14 RR Operand Range * See condition codes or Working Register Pair Ir Indirect Working Register @Rn n = 0 –15 IR Indirect Register Reg. represents a number in the range of 00h to FFh @Reg or Indirect Working Register @Rn n = 0– 15 Irr Indirect Working Register @RRp Pair p = 0, 2, 4, 6, 8, 10, 12, or 14 IRR Indirect Register Pair Reg. represents an even number in the range 00h to FFh @Reg *Note: *See the device product specification to determine the exact register file range available. The register file size varies by the device type. Instruction Set UM001602-0904 Z8 CPU User Manual 211 Table 37. Notational Shorthand Notation Address Mode Operand Range * Working Register Pair @RRp p = 0, 2, 4, 6, 8, 10, 12, or 14 X Indexed Reg (Rn) Reg. represents a number in the range of 00h to FFh and n = 0–15 DA Direct Address Addrs Addrs. represents a number in the range of 00h to FFh RA Relative Address Addrs Addrs. represents a number in the range of +127 to –128 which is an offset relative to the address of the next instruction IM Immediate #Data Data is a number between 00h to FFh or *Note: *See the device product specification to determine the exact register file range available. The register file size varies by the device type. Additional symbols used are listed in Table 38. Table 38. Additional Symbols UM001602-0904 Symbol Definition dst Destination Operand src Source Operand @ Indirect Address Prefix SP Stack Pointer PC Program Counter FLAGS Flag Register (FCh) RP Register Pointer (FDh) Instruction Set Z8 Family of Microcontrollers User Manual 212 Table 38. Additional Symbols Symbol Definition IMR Interrupt Mask Register (FBh) # Immediate Operand Prefix % Hexadecimal Number Prefix H Hexadecimal Number Suffix B Binary Number Suffix OPC Opcode Assignment of a value is indicated by the symbol “←”. For example, dst ← dst + src indicates the source data is added to the destination data and the result is stored in the destination location. The notation 'addr(n)' is used to refer to bit'n' of a given location. For example, dst (7) refers to bit 7 of the destination operand. Assembly Language Syntax For proper instruction execution, Z8 assembly language syntax requires ‘dst, src’ be specified, in that order. The following instruction descriptions show the format of the object code produced by the assembler. This binary format should be followed by users who prefer manual program coding or who intend to implement their own assembler. Example: If the contents of registers 43h and 08h are added and the result is stored in 43h, the assembly syntax and resulting object code is: Instruction Set UM001602-0904 Z8 CPU User Manual 213 ASM: ADD 43h, 08h (ADD dst, src) OBJ: 04 08 43 (OPC src, dst) In general, whenever an instruction format requires an 8-bit register address, that address can specify any register location in the range 0–255 or a Working Register R0–R15. If, in the above example, register 08h is a Working Register, the assembly syntax and resulting object code would be: ASM: ADD 43h, 08h (ADD dst, src) OBJ: 04 08 43 (OPC src, dst) See the device product specification to determine the exact register file range available. The register file size varies by device type. Z8 Instruction Summary Table 39. Summary of Z8 Instruction Set Instruction and Operation Address Mode dst src Op Code Flags Affected Byte (Hex) C Z S V D H ADC dst, src dst ← dst + src +C † 1[ ] [ [ [ [ 0 [ ADD dst, src dst ← dst + src † 0[ ] [ [ [ [ 0 [ AND dst, src dst ← dst AND src † 5[ ] – [ [ 0 – – *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 214 Table 39. Summary of Z8 Instruction Set Address Mode Op Code Flags Affected Byte (Hex) C Z S V D H Instruction and Operation dst CALL dst DA D6 SP ← SP–2 and PC ← dst or @ SP ← PC IRR D4 CCF C ←NOT C src – – – – – – EF [ – – – – – – – – – – – – [ [ 0 – – CLR dst R B0 dst ← 0 IR B1 COM dst R 60 dst ← NOT dst IR 61 CP dst, src dst − src † A[ ] [ [ [ [ – – DA dst R 40 [ [ [ X – – dst ← DA dst IR 41 DEC dst R 00 – [ [ [ – – dst ← dst–1 IR 01 RR 80 – [ [ [ – – IR 81 – – – – – – DECW dst dst ← dst–1 DI dst IMR(7) ← 0 8F *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. Instruction Set UM001602-0904 Z8 CPU User Manual 215 Table 39. Summary of Z8 Instruction Set Address Mode Instruction and Operation dst DJNZr, dst RA src r ← r–1 if r ≠ 0 PC ← PC + dst Range:+127, –128 Op Code Flags Affected Byte (Hex) C Z S V D H rA – – – – – – 9F – – – – – – 7F – – – – – – rE – [ [ [ – – – [ [ [ – – r = 0-F EI IMR(7) ← 1 HALT INC dst dst ← dst + 1 r r = 0-F R 20 IR 21 INCW dst RR A0 dst ← dst + 1 IR A1 Instruction and Operation Address Mode dst src Op Code Flags Affected Byte (Hex) C Z S V D H *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 216 Table 39. Summary of Z8 Instruction Set Instruction and Operation Address Mode dst src IRET FLAGS←@SP; SP ← SP + 1 PC ← @SP; SP ← SP + 2; and IMR(7)–1 JP cc, dst DA if cc is true, Op Code Flags Affected Byte (Hex) C Z S V D H BF [ [ [ [ [ [ cD – – – – – – – – – – – – – – – – – – c = 0–F then PC ← dst IRR 30 JR cc, dst RA cB if cc is true, PC ← PC + dst Range: +127, –128 LD dst, src c = 0–F r Im rC *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. Instruction Set UM001602-0904 Z8 CPU User Manual 217 Table 39. Summary of Z8 Instruction Set Instruction and Operation dst ← src Address Mode Op Code Flags Affected Byte (Hex) C Z S V D H dst src r R r8 R r r9 r = 0–F r X C7 X r D7 r Ir E3 Ir r F3 R R E4 R IR E5 R IM E6 IR IM E7 IR R F5 LDC dst, src r Irr C2 dst ← src lrr r D2 LDCI dst, src Ir Irr C3 dst ← src r ← r + 1 or rr ←rr + 1 lrr Ir D3 LDE dst, src r Irr 82 – – – – – – – – – – – – – – – – – – *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 218 Table 39. Summary of Z8 Instruction Set Instruction and Operation Address Mode Op Code Flags Affected Byte (Hex) C Z S V D H dst src dst ← src lrr r 92 LDEI dst, src Ir Irr 83 dst ← src and r ← r + 1 or rr ←rr + 1 lrr Ir 93 NOP – – – – – – FF – – – – – – OR dst, src dst ← dst OR src † 4[ ] – [ [ 0 – – POP dst R 50 – – – – – – dst ← @SP and SP ← SP + 1 IR 51 PUSH src R 70 – – – – – – SP ← SP–1 and @SP ← src IR 71 RCF C←0 CF 0 – – – – – RET PC ← @SP; SP ← SP + 2 AF – – – – – – 90 91 [ [ [ [ – – RL dst C 7 0 R IR *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. Instruction Set UM001602-0904 Z8 CPU User Manual 219 Table 39. Summary of Z8 Instruction Set Address Mode Instruction and Operation dst RLC dst 0 7 C RR dst RRC dst C R IR 10 11 [ [ [ [ – – R IR E0 E1 [ [ [ [ – – R C0 [ [ [ [ – – IR C1 † 3[ ] [ [ [ [ 1 [ DF 1 – – – – – R D0 [ [ [ 0 – – IR D1 Im 31 – – – – – – 6F – – – – – – 2[ ] [ [ [ [ 1 [ 0 7 C 0 7 SBC dst, src dst ← dst–src–C SCF C←1 SRA dst 7 C SRP dst RP ← src 0 STOP SUB dst, src dst ← dst–src src Op Code Flags Affected Byte (Hex) C Z S V D H † *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. UM001602-0904 Instruction Set Z8 Family of Microcontrollers User Manual 220 Table 39. Summary of Z8 Instruction Set Address Mode Instruction and Operation dst SWAP dst src Op Code Flags Affected Byte (Hex) C Z S V D H R IR F0 F1 X [ [ X – – TCM dst, src (NOT dst) AND src † 6[ ] – [ [ 0 – – TM dst, src dst AND src † 7[ ] – [ [ 0 – – WDh 4F – X X X – – WDT 5F – X X X – – 7[ ] – [ [ 0 – – 7 4 3 XOR dst, src dst AND src XOR src 0 † *Note: These instructions have an identical set of addressing modes, which are encoded for brevity. The first opcode nibble is found in the instruction set table above. The second nibble is expressed symbolically by a ‘[ ]’ in this table, and its value is found in the following table to the left of the applicable addressing mode pair. For example, the opcode of an ADC instruction using the addressing modes r (destination) and Ir (source) is 13. Instruction Set UM001602-0904 Z8 CPU User Manual 221 Table 40. Summary of Z8® Address Modes Address Mode UM001602-0904 dst src Lower Op Code Nibble r r [2] r Ir [3] R R [4] R IR [5] R IM [6] IR IM [7] Instruction Set Z8 Family of Microcontrollers User Manual 222 Op Code Map Lower Nibble (Hex) 0 0 1 2 3 4 5 Upper Nibble (Hex) 6 7 8 9 A B C D E F 1 6.5 DEC R1 6.5 RLC R1 6.5 INC R1 8.0 JP IRR1 8.5 DA R1 10.5 POP R1 6.5 COM R1 10/12.1 PUSH R2 10.5 DECW RR1 6.5 RL R1 10.5 INCW RR1 6.5 CLR R1 6.5 RRC R1 6.5 SRA R1 6.5 RR R1 8.5 SWAP R1 2 3 6.5 6.5 6.5 DEC ADD ADD IR1 r1, r2 r1, Ir2 6.5 6.5 6.5 RLC ADC ADC IR1 r1, r2 r1, Ir2 6.5 6.5 6.5 INC SUB SUB IR1 r1, r2 r1, Ir2 6.1 6.5 6.5 SRP SBC SBC IM r1, r2 r1, Ir2 8.5 6.5 6.5 DA OR OR IR1 r1, r2 r1, Ir2 10.5 6.5 6.5 POP AND AND IR1 r1, r2 r1, Ir2 6.5 6.5 6.5 COM TCM TCM IR1 r1, r2 r1, Ir2 12/14.1 6.5 6.5 PUSH TM TM IR2 r1, r2 r1, Ir2 10.5 12.0 18.0 DECW LDE LDEI r1, lrr2 lr1, lrr2 IR1 6.5 12.0 18.0 RL LDE LDEI IR1 r2, lrr1 lr2, lrr1 10.5 6.5 6.5 INCW CP CP IR1 r1, r2 r1, Ir2 6.5 6.5 6.5 CLR XOR XOR IR1 r1, r2 r1, Ir2 6.5 12.0 18.0 RRC LDC LDCI IR1 r1, Irr2 Ir1, Irr2 6.5 12.0 18.0 SRA LDC LDCI lrr1, r2 lrr1, Ir2 IR1 6.5 6.5 RR LD IR1 r1, IR2 8.5 6.5 SWAP LD Ir1, r2 IR1 4 5 6 10.5 ADD R2, R1 10.5 ADC R2, R1 10.5 SUB R2, R1 10.5 SBC R2, R1 10.5 OR R2, R1 10.5 AND R2, R1 10.5 TCM R2, R1 10.5 TM R2, R1 10.5 ADD IR2, R1 10.5 ADC IR2, R1 10.5 SUB IR2, R1 10.5 SBC IR2, R1 10.5 OR IR2, R1 10.5 AND IR2, R1 10.5 TCM IR2, R1 10.5 TM IR2, R1 10.5 ADD R1, IM 10.5 ADC R1, IM 10.5 SUB R1, IM 10.5 SBC R1, IM 10.5 OR R1, IM 10.5 AND R1, IM 10.5 TCM R1, IM 10.5 TM R1, IM 7 8 10.5 6.5 ADD LD IR1, IM r1, R2 10.5 ADC IR1, IM 10.5 SUB IR1, IM 10.5 SBC IR1, IM 10.5 OR IR1, IM 10.5 AND IR1, IM 10.5 TCM IR1, IM 10.5 TM IR1, IM 9 A B 6.0 WDT 6.0 STOP 7.0 HALT 10.5 10.5 10.5 10.5 CP CP CP CP R2, R1 IR2, R1 R1, IM IR1, IM 10.5 10.5 10.5 10.5 XOR XOR XOR XOR R2, R1 IR2, R1 R1, IM IR1, IM 10.5 LD r1,x,R2 20.0 20.0 10.5 CALL* CALL LD IRR1 DA r2,x,R1 10.5 10.5 10.5 10.5 LD LD LD LD R2, R1 IR2, R1 R1, IM IR1, IM 10.5 LD R2, IR1 14.0 RET 16.0 IRET 6.5 RCF 6.5 SCF 6.5 CCF 6.0 NOP 2 Lower Op Code Nibble Pipeline Cycles 4 10.5 CP R 2, R1 F 6.1 EI 3 A E 6.5 INC r1 6.0 WDh Bytes per Instruction Upper Op Code Nibble D 12.10.0 JP cc, DA 6.1 DI 2 Fetch Cycles C 6.5 12/10.5 12/10.0 6.5 LD DJNZ JR LD r2, R1 r1, RA cc, RA r1, IM Mnemonic 3 1 Legend: R = 8-Bit Addr ess r = 4-Bit Addr ess R1 or r1 = Dst Addr ess R2 or r2 = Src Address Sequence: Opcode, First Operand, Second Operand Note: Blank areas are reserved. First Operand Second Operand *2-byte instruction appears as a 3-byte instruction Figure 134. Op Code Map Instruction Set UM001602-0904 Z8 CPU User Manual 223 Instruction Description Table 41 contains a brief description of each of the ZTP process manipulation functions. Use the hyperlinks in Table 41 to jump quickly to more complete descriptions. Table 41. Process Manipulation Functions Add Logical OR Add With Carry Logical Exclusive OR Call Procedure Pop Complement Carry Flag Push Clear Reset Carry Flag Complement Return Compare Rotate Left Decimal Adjust Rotate Left Through Carry Decrement Rotate Right Decrement and Jump if Non-Zero Rotate Right Through Carry Decrement Word Set Carry Flag Disable Interrupts Set Register Pointer Enable Interrupts Shift Right Arithmetic Halt Rotate Right Through Carry Increment Set Carry Flag Increment Word Set Register Pointer Interrupt Return Shift Right Arithmetic Jump Stop Jump Relative Subtract Load Subtract With Carry UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 224 Table 41. Process Manipulation Functions (Continued) Load Constant Swap Nibbles Load Constant Autoincrement Test Complement Under Mask Load External Data Test Under Mask Load External Data Autoincrement Watch-Dog Timer No Operation Watch-Dog Timer Enable During Halt Mode Logical AND Instruction Description UM001602-0904 Z8 CPU User Manual 225 Add ADD dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 02 03 Address Mode dst src r r r lr OPC src dst 10 10 04 05 R R R IR OPC dst src 10 10 06 07 R IR IM IM Operation dst ← dst + src The source operand is added to the destination operand. Two’s complement addition is performed. The sum is stored in the destination operand. The contents of the source operand are not affected. Flags Description C Set if there is a carry from the most significant bit of the result; cleared otherwise. Z Set if the result is zero; cleared otherwise. S Set if the result is negative; cleared otherwise. V Set if an arithmetic overflow occurs, that is, if both operands are of the same sign and the result is of the opposite sign; cleared otherwise. D Always cleared. H Set if there is a carry from the most significant bit of the low order four bits of the result; cleared otherwise. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 226 Address modes R or IR can be used to specify a 4-bit Working Register. In Note: this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R3 contains 16h and Working Register R11 contains 20h, the statement: ADD R3, R11 Op Code: 02 3B leaves the value 36h in Working Register R3. The C, Z, S, V, D, and H Flags are all cleared. Example If Working Register R16 contains 16h, Working Register R10 contains 20h, and Register 20h contains 11h, the statement: ADD R16, @R10 Op Code: 03 FA leaves the value 27h in Working Register R16. The C, Z, S, V, D, and H Flags are all cleared. Example If Register 34h contains 2Eh and Register 12h contains 1Bh, the statement: ADD 34h, 12h Op Code: 04 12 34 leaves the value 49h in Register 34h. The H Flag is set, and the C, Z, S, V, and D flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 227 Example If Register 4Bh contains 82h, Working Register R3 contains 10h, and Register 10h contains 01h, the statement: ADD 3Eh, @R3 Op Code: 05 E3 4B leaves the value 83h in Register 4Bh. The S Flag is set, and the C, Z, V, D, and H flags are cleared. Example If Register 6Ch contains 2Ah, the statement: ADD 6Ch, #03h Op Code: 06 6C 03 leaves the value 2Dh in Register 6Ch. The C, Z, S, V, D, and H Flags are all cleared. Example If Register D4h contains 5Fh and Register 5Fh contains 4Ch, the statement: ADD @D4h, #02h Op Code: 07 D4 02 leaves the value 4Eh in Register 5Fh. The C, Z, S, V, D, and H Flags are all cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 228 Add With Carry Syntax ADC dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 02 03 Address Mode dst src r r r lr OPC src dst 10 10 04 05 R R R IR OPC dst src 10 10 06 07 R IR IM IM Operation dst ← dst + src + C The source operand, along with the setting of the Carry (C) Flag, is added to the destination operand. Two’s complement addition is performed. The sum is stored in the destination operand. The contents of the source operand are not affected. In multiple precision arithmetic, this instruction permits the carry from the addition of low order operands to be carried into the addition of high order operands. Instruction Description UM001602-0904 Z8 CPU User Manual 229 Flag C Z S V D H Description Set if there is a carry from the most significant bit of the result; cleared otherwise. Set if the result is zero; cleared otherwise. Set if the result is negative; cleared otherwise. Set if an arithmetic overflow occurs, that is, if both operands are of the same sign and the result is of the opposite sign; cleared otherwise. Always cleared. Set if there is a carry from the most significant bit of the low order four bits of the result; cleared otherwise. Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R3 contains 16h, the C Flag is set to 1, and Working Register R11 contains 20h, the statement: ADC R3, R11 Op Code: 12 3B leaves the value 37h in Working Register R3. The C, Z, S, V, D, and H Flags are all cleared. Example If Working Register R16 contains 16h, the C Flag is not set, Working Register R10 contains 20h, and Register 20h contains 11h, the statement: ADC R16, @R10 Op Code: 13 FA UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 230 leaves the value 27h in Working Register R16. The C, Z, S, V, D, and H Flags are all cleared. Example If Register 34h contains 2Eh, the C Flag is set, and Register 12h contains 1Bh, the statement: ADC 34h, 12h Op Code: 14 12 34 leaves the value 4Ah in Register 34h. The H Flag is set, and the C, Z, S, V, and D flags are cleared. Example If Register 4Bh contains 82h, the C Flag is set, Working Register R3 contains 10h, and Register 10h contains 01h, the statement: ADC 4Bh, @R3 Op Code: 15 E3 4B leaves the value 84h in Register 4Bh. The S Flag is set, and the C, Z, V, D, and H flags are cleared. Example If Register 6Ch contains 2Ah, and the C Flag is not set, the statement: ADC 6Ch, #03h Op Code: 16 6C 03 leaves the value 2Dh in Register 6Ch. The C, Z, S, V, D, and H Flags are all cleared. Example If Register D4h contains 5Fh, Register 5Fh contains 4Ch, and the C Flag is set, the statement: ADC @D4h, #02h Op Code: 17 D4 02 Instruction Description UM001602-0904 Z8 CPU User Manual 231 leaves the value 4Fh in Register 5Fh. The C, Z, S, V, D, and H Flags are all cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 232 Call Procedure CALL dst Instruction Format OPC dst OPC dst Cycles OPC (Hex) Address Mode dst 20 D6 DA 20 D4 IRR Operation SP ← SP–2 @SP ← PC PC ← dst The Stack pointer is decremented by two, the current contents of the Program Counter (PC) (address of the first instruction following the CALL instruction) are pushed onto the top of the Stack, and the specified destination address is then loaded into the PC. The PC now points to the first instruction of the procedure. At the end of the procedure a RET (return) instruction can be used to return to the original program flow. RET will pop the top of the Stack and replace the original value into the PC. Flag C Z S V D H Instruction Description Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected UM001602-0904 Z8 CPU User Manual 233 Address mode IRR can be used to specify a 4-bit Working Register Pair. In Note: this format, the destination Working Register Pair operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register Pair RR12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If the contents of the PC are 1A47h and the contents of the SP (Registers FEh and FFh) are 3002h, the statement: CALL 3521h Op Code: D6 35 21 causes the SP to be decremented to 3000h, 1A4Ah (the address following the CALL instruction) to be stored in external data memory 3000 and 3001h, and the PC to be loaded with 3521h. The PC now points to the address of the first statement in the procedure to be executed. Example If the contents of the PC are 1A47h, the contents of the SP (Register FFh) are 72h, the contents of Register A4h are 34h, and the contents of Register Pair 34h are 3521h, the statement: CALL @A4h Op Code: D4 A4 causes the SP to be decremented to 70h, 1A4Ah (the address following the CALL instruction) to be stored in R70h and 71h, and the PC to be loaded with 3521h. The PC now points to the address of the first statement in the procedure to be executed. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 234 Complement Carry Flag CCF Instruction Format OPC Cycles OPC (Hex) 6 EF Operation C ← NOT C The C Flag is complemented. If C = 1, then it is changed to C = 0; or, if C = 0, then it is changed to C = 1. Flag C Z S V D H Description Complemented Unaffected Unaffected Unaffected Unaffected Unaffected Example If the C Flag contains a 0, the statement: CCF Op Code: EF will change the C Flag from C = 0 to C = 1. Instruction Description UM001602-0904 Z8 CPU User Manual 235 Clear CLR dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) 80 81 Address dst R IR Operation dst ← 0 The destination operand is cleared to 00h. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Working Register R6 contains AFh, the statement: CLR R6 Op Code: B0 E6 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 236 will leave the value 00h in Working Register R6. If Register A5h contains the value 23h, and Register 23h contains the value FCh, the statement: CLR @A5h Op Code: B1 A5 will leave the value 00h in Register 23h. Instruction Description UM001602-0904 Z8 CPU User Manual 237 Complement COM dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) 60 61 Address Mode dst R IR Operation dst ← NOT dst The contents of the destination operand are complemented (one’s complement). All 1 bits are changed to 0, and all 0 bits are changed to 1. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise. Set if result bit 7 is set; cleared otherwise. Always reset to 0. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Register 08h contains 24h (00100100b), the statement: UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 238 COM 08h Op Code: 60 08 leaves the value DBh (11011011) in Register 08h. The S Flag is set, and the Z and V flags are cleared. Example If Register 08h contains 24h, and Register 24h contains FFh (11111111b), the statement: COM @08h Op Code: 61 08 leaves the value 00h (00000000b) in Register 24h. The Z Flag is set, and the V and S flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 239 Compare CP dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) A2 A3 Address Mode dst src r r r lr OPC src dst 10 10 A4 A5 R R R IR OPC dst src 10 10 A6 A7 R IR IM IM Operation dst–src The source operand is compared to (subtracted from) the destination operand, and the appropriate flags are set accordingly. The contents of both operands are unaffected. Flag C Z S V D H Description Cleared if there is a carry from the most significant bit of the result. Set otherwise indicating a borrow. Set if the result is zero; cleared otherwise. Set if result bit 7 is set (negative); cleared otherwise. Set if arithmetic overflow occurs; cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 240 if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. Example E src or E dst If Working Register R3 contains 16h and Working Register R11 contains 20h, the statement: CP R3, R11 Op Code: A2 3B sets the C and S Flags, and the Z and V flags are cleared. Example If Working Register R15 contains 16h, Working Register R10 contains 20h, and Register 20h contains 11h, the statement: CP R16, @R10 Op Code: A3 FA clears the C, Z, S, and V Flags. Example If Register 34h contains 2Eh and Register 12h contains 1Bh, the statement: CP 34h,12h Op Code: A4 12 34 clears the C, Z, S, and V Flags. Example If Register 4Bh contains 82h, Working Register R3 contains 10h, and Register 10h contains 01h, the statement: CP 4Bh, @R3 Op Code: A5 E3 4B Instruction Description UM001602-0904 Z8 CPU User Manual 241 sets the S Flag, and clears the C, Z, and V Flags. Example If Register 6Ch contains 2Ah, the statement: CP 6Ch, #2Ah Op Code: A6 6C 2A sets the Z Flag, and the C, S, and V Flags are all cleared. Example If Register D4h contains FCh, and Register FCh contains 8Fh, the statement: CP @D4h, 7Fh Op Code: A7 D4 FF sets the V Flag, and the C, Z, and S Flags are all cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 242 Decimal Adjust DA dst Instruction Format OPC dst Cycles 8 8 OPC (Hex) 40 41 Address Mode dst R IR Operation dst ← DA dst The destination operand is adjusted to form two 4-bit BCD digits following a binary addition or subtraction operation on BCD encoded bytes. For addition (ADD and ADC) or subtraction (SUB and SBC), the following table indicates the operation performed. Instruction ADD ADC SUB Instruction Description Carry Before DA 0 0 0 0 0 0 1 1 1 0 0 Bits 7–4 Value (Hex) 0–9 0–8 0–9 A–F 9–F A–F 0–2 0–2 0–3 0–9 0–8 H Flag Before DA 0 0 1 0 0 1 0 0 1 0 1 Bits 3–0 Value (Hex) 0–9 A–F 0–3 0–9 A–F 0–3 0–9 A–F 0–3 0–9 6–F Number Added To Byte 00 06 06 60 66 66 60 66 66 00 FA UM001602-0904 Carry After DA 0 0 0 1 1 1 1 1 1 0 0 Z8 CPU User Manual 243 Instruction SBC Carry Before DA 1 1 Bits 7–4 Value (Hex) 7–F 6–F H Flag Before DA 0 1 Bits 3–0 Value (Hex) 0–9 6–F Number Added To Byte A0 9A If the destination operand is not the result of a valid addition or subtraction of BCD digits, the operation is undefined. Flag C Z S D H Description Set if there is a carry from the most significant bit; cleared otherwise (see table above). Set if the result is zero; cleared otherwise. Set if result bit 7 is set (negative); cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If addition is performed using the BCD value 15 and 27, the result should be 42. The sum is incorrect, however, when the binary representations are added in the destination location using standard binary arithmetic. 0001 0101 = 15h + 0010 0111 = 27h 0011 1100 = 3Ch UM001602-0904 Instruction Description Carry After DA 1 1 Z8 Family of Microcontrollers User Manual 244 If the result of the addition is stored in Register 5Fh, the statement: DA 5Fh Op Code: 40 5F adjusts this result so the correct BCD representation is obtained. 0011 1100 = 3Ch 0000 0110 = 06h 0100 0010 = 42h Register 5Fh now contains the value 42h. The C, Z, and S flags are cleared, and V is undefined. Example If addition is performed using the BCD value 15 and 27, the result should be 42. The sum is incorrect, however, when the binary representations are added in the destination location using standard binary arithmetic. 0001 0101 = 15h + 0010 0111 = 27h 0011 1100 = 3Ch Register 45F contains the value 5Fh, and the result of the addition is stored in Register 5Fh, the statement: DA @45h Op Code: 40 45 adjusts this result so the correct BCD representation is obtained. 0011 1100 = 3Ch 0000 0110 = 06h 0100 0010 = 42h Register 5Fh now contains the value 42h. The C, Z, and S flags are cleared, and V is undefined. Instruction Description UM001602-0904 Z8 CPU User Manual 245 Decrement DEC dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) 00 01 Address Mode dst R IR Operation dst ← dst–1 The contents of the destination operand are decremented by one. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise Set if the result of bit 7 is set (negative); cleared otherwise Set if arithmetic overflow occurs; cleared otherwise Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Working Register R10 contains 2A%, the statement: DEC R10 Op Code: 00 EA UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 246 leaves the value 29h in Working Register R10. The Z, V, and S flags are cleared. Example If Register B3h contains CBh, and Register CBh contains 01h, the statement: DEC @B3h Op Code: 01 B3 leaves the value 00h in Register CBh. The Z Flag is set, and the V and S flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 247 Decrement and Jump if Non-Zero DJNZ r, dst Instruction Format r OPC dst Cycles 12 If jump taken 10 if jump not taken OPC (Hex) rA (R = 0 to F) Address Mode dst r r Operation r ← r–1; If r <> 0, PC ← PC + dst The specified Working Register being used as a counter is decremented. If the contents of the specified Working Register are not zero after decrementing, then the relative address is added to the Program Counter (PC) and control passes to the statement whose address is now in the PC. The range of the relative address is +127 to –128. The original value of the PC is the address of the instruction byte following the DJNZ statement. When the specified Working Register counter reaches zero, control falls through to the statement following the DJNZ instruction. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: The Working Register being used as a counter must be one of the Registers from 04h to EFh. Use of one of the I/O ports, control or peripheral registers will have undefined results. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 248 Example DJNZ is typically used to control a loop of instructions. In this example, 12 bytes are moved from one buffer area in the register file to another. The steps involved are: • • • Load 12 into the counter (Working Register R6) Set up the loop to perform the moves End the loop with DJNZ The assembly listing required for this routine is as follows: LD R6, 12 LOOP: LD R9, @R6 LD @R6, R9 DJNZ R6, LOOP Instruction Description ;Load Counter ;Move one byte to ;new location ;Decrement and Loop until counter ;= 0 UM001602-0904 Z8 CPU User Manual 249 Decrement Word DECW dst Instruction Format OPC dst Cycles 10 10 OPC (Hex) 80 81 Address Mode dst RR IR Operation dst ← dst–1 The contents of the destination (which must be an even address) operand are decremented by one. The destination operand can be a Register Pair or a Working Register Pair. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise Set if the result of bit 7 is set (negative); cleared otherwise Set if arithmetic overflow occurs; cleared otherwise Unaffected Unaffected Note: Address modes RR or IR can be used to specify a 4-bit Working Register Pair. In this format, the destination Working Register Pair operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register Pair R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Register Pair 30h and 31h contain the value 0AF2h, the statement: UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 250 DECW 30h Op Code: 80 30 leaves the value 0AF1h in Register Pair 30h and 31h. The Z, V, and S flags are cleared. Example If Working Register R0 contains 30h and Register Pairs 30h and 31h contain the value FAF3h, the statement: DECW @R0 Op Code: 81 E0 leaves the value FAF2h in Register Pair 30h and 31h. The S Flag is set, and the Z and V flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 251 Disable Interrupts Dl Instruction Format Cycles OPC (Hex) 6 8F OPC Operation IMR (7) ← 0 Bit 7 of Control Register FBh (the Interrupt Mask Register) is reset to 0. All interrupts are disabled, although they remain potentially enabled. (For instance, the Global Interrupt Enable is cleared, but not the individual interrupt level enables.) Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Example If Control Register FBh contains 8Ah (10001010) (interrupts IRQ1 and IRQ3 are enabled), the statement: DI Op Code: 8F sets Control Register FBh to 0Ah (00001010b) and disables these interrupts. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 252 Enable Interrupts EI Instruction Format Cycles OPC (Hex) 6 9F OPC Operation IMR (7) ← 0 Bit 7 of Control Register FBh (the Interrupt Mask Register) is set to 1. This allows potentially enabled interrupts to become enabled. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Example If Control Register FBh contains 0Ah (00001010) (interrupts IRQ1 and IRQ3 are selected), the statement: EI Op Code: 9F sets Control Register FBh to 8Ah (10001010b) and enables IRQ1 and IRQ3. Instruction Description UM001602-0904 Z8 CPU User Manual 253 Halt HALT Instruction Format OPC Cycles OPC (Hex) 6 7F Operation The HALT instruction turns off the internal CPU clock, but not the XTAL oscillation. The counter/timers and the external interrupts IRQ1, IRQ2, and IRQ3 remain active. The devices are recovered by interrupts, either externally or internally generated. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: In order to enter HALT mode, it is necessary to first flush the instruction pipeline to avoid suspending execution in mid-instruction. The user must execute a NOP immediately before the execution of the HALT instruction. Example Assuming the Z8® CPU is in normal operation, the statements: NOP HALT Op Codes: FF 7F place the Z8® CPU into HALT mode. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 254 Increment Instruction Format dst OPC OPC dst Cycles OPC (Hex) Address Mode dst 6 rE r 6 6 20 21 R IR Operation dst ← dst + 1 The contents of the destination operand are incremented by one. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise. Set if the result of bit 7 is set (negative); cleared otherwise. Set if arithmetic overflow occurs; cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Working Register R10 contains 2Ah, the statement: Instruction Description UM001602-0904 Z8 CPU User Manual 255 INC R10 Op Code: AE leaves the value 2Bh in Working Register R10. The Z, V, and S flags are cleared. Example If Register B3h contains CBh, the statement: INC B3h Op Code: 20 B3 leaves the value CCh in Register CBh. The S Flag is set, and the Z and V flags are cleared. Example If Register B3h contains CBh and Register BCh contains FFh, the statement: INC @B3h Op Code: 21 B3 leaves the value 00h in Register CBh. The Z Flag is set, and the V and S flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 256 Increment Word INCW dst Instruction Format OPC dst Cycles 10 10 10 OPC (Hex) A0 A1 A0 Address Mode dst RR IR R Operation dst ← dst–1 The contents of the destination (which must be an even address) operand is decremented by one. The destination operand can be a Register Pair or a Working Register Pair. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise. Set if the result of bit 7 is set (negative); cleared otherwise. Set if arithmetic overflow occurs; cleared otherwise. Unaffected Unaffected Note: Address modes RR or IR can be used to specify a 4-bit Working Register Pair. In this format, the destination Working Register Pair operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register Pair R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code E dst Example If Register Pairs 30h and 31h contain the value 0AF2h, the statement: Instruction Description UM001602-0904 Z8 CPU User Manual 257 INCW 30h Op Code: A0 30 leaves the value 0AF3h in Register Pair 30h and 31h. The Z, V, and S flags are cleared. Example If Working Register R0 contains 30h, and Register Pairs 30h and 31h contain the value FAF3h, the statement: INCW @R0 Op Code: A1 E0 leaves the value FAF4h in Register Pair 30h and 31h. The S Flag is set, and the Z and V flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 258 Interrupt Return IRET Instruction Format Cycles OPC (Hex) 16 8F OPC Operation FLAGS ← @SP SP ← SP + 1 PC ← @SP SP ← SP + 2 IMR (7) ← 1 This instruction is issued at the end of an interrupt service routine. It restores the Flag Register (Control Register FCh) and the PC. It also reenables any interrupts that are potentially enabled. Flag C Z S V D H Description Restored to original setting before the interrupt occurred. Restored to original setting before the interrupt occurred. Restored to original setting before the interrupt occurred. Restored to original setting before the interrupt occurred. Restored to original setting before the interrupt occurred. Restored to original setting before the interrupt occurred. Example If Stack Pointer Low Register FFh currently contains the value 45h, Register 45h contains the value 00h, Register 46h contains 6Fh, and Register 47 contains E4h, the statement: IRET Op Code: BF Instruction Description UM001602-0904 Z8 CPU User Manual 259 restores the FLAG Register FCh with the value 00h, restores the PC with the value 6FE4h, re-enables the interrupts, and sets the Stack Pointer Low to 48h. The next instruction to be executed will be at location 6FE4h. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 260 Jump JP cc, dst Instruction Format cc OPC dst dst dst Cycles 12 If jump taken 10 if jump not taken 8 OPC (Hex) ccD cc = 0 to F Address Mode dst DA 30 IRR Operation If cc (condition code) is true, then PC ← dst A conditional jump transfers Program Control to the destination address if the condition specified by cc (condition code) is true. Otherwise, the instruction following the JP instruction is executed. See Section 12.3 for a list of condition codes. The unconditional jump simply replaces the contents of the Program Counter with the contents of the register pair specified by the destination operand. Program Control then passes to the instruction addressed by the PC. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: Address mode IRR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Instruction Description UM001602-0904 Z8 CPU User Manual 261 Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the Carry Flag is set, the statement: JP C, 1520h Op Code: 7D 15 20 replaces the contents of the Program Counter with 1520h and transfers program control to that location. If the Carry Flag had not been set, control would have fallen through to the statement following the JP instruction. Example If Working Register Pair RR2 contains the value 3F45h, the statement: JP @RR2 Op Code: 30 E2 replaces the contents of the PC with the value 3F45h and transfers program control to that location. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 262 Jump Relative JR cc, dst Instruction Format cc OPC dst Cycles 12 If jump taken 10 if jump not taken OPC (Hex) ccB cc = 0 to F Address Mode dst RR Operation If cc is true, PC ← PC + dst If the condition specified by the cc is true, the relative address is added to the PC and control passes to the instruction located at the address specified by the PC (See Section 12.3 for a list of condition codes). Otherwise, the instruction following the JR instruction is executed. The range of the relative address is +127 to –128, and the original value of the PC is taken to be the address of the first instruction byte following the JR instruction. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Example If the result of the last arithmetic operation executed is negative, the next four statements (which occupy a total of seven bytes) are skipped with the statement: JR Ml, #9 Op Code: 5B 09 Instruction Description UM001602-0904 Z8 CPU User Manual 263 If the result was not negative, execution would have continued with the instruction following the JR instruction. Example A short form of a jump –45 is: JR #–45 Op Code: 8B D3 The condition code is blank in this case, and is assumed to be always true. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 264 Load LD dst, src Instruction Format dst OPC src src OPC dst OPC dst Cycles 6 6 OPC OPC (Hex) rC r8 Address Mode dst src r IM r R 6 r9 R* r = 0 to F r 6 6 E3 F3 r Ir Ir r OPC src dst 10 10 E4 E5 R R R IR OPC dst src 10 10 E6 E7 R IR IM IM OPC src dst 10 F5 IR R OPC dst X src 10 C7 r X OPC src X dst 10 D7 X r Operation dst ← src The contents of the source operand are loaded into the destination operand. The contents of the source operand are not affected. Instruction Description UM001602-0904 Z8 CPU User Manual 265 Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example The statement: LD R15, #34h Op Code: FC 34 loads the value 34h into Working Register R15. Example If Register 34h contains the value FCh, the statement: LD R14, 34h Op Code: F8 34 loads the value FCh into Working Register R15. The contents of Register 34h are not affected. Example If Working Register R14 contains the value 45h, the statement: UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 266 LD 34h, R14 Op Code: E9 34 loads the value 45h into Register 34h. The contents of Working Register R14 are not affected. Example If Working Register R12 contains the value 34h, and Register 34h contains the value FFh, the statement: LD R13, @R12 Op Code: E3 DC loads the value FFh into Working Register R13. The contents of Working Register R12 and Register R34 are not affected. Example If Working Register R13 contains the value 45h, and Working Register R12 contains the value 00h the statement: LD @R13, R12 Op Code: F3 DC loads the value 00h into Register 45h. The contents of Working Register R12 and Working Register R13 are not affected. Example If Register 45h contains the value CFh, the statement: LD 34h, 45h Op Code: E4 45 34 loads the value CFh into Register 34h. The contents of Register 45h are not affected. Example If Register 45h contains the value CFh and Register CFh contains the value FFh, the statement: Instruction Description UM001602-0904 Z8 CPU User Manual 267 LD 34h, @45h Op Code: E5 45 34 loads the value FFh into Register 34h. The contents of Register 45h and Register CFh are not affected. Example The statement: LD 34h, #A4h Op Code: E6 34 A4 loads the value A4h into Register 34h. Example If Working Register R14 contains the value 7Fh, the statement: LD @R14, #FCh Op Code: E7 EE FC loads the value FCh into Register 7Fh. The contents of Working Register R14 are not affected. Example If Register 34h contains the value CFh and Register 45h contains the value FFh, the statement: LD @34h, 45h Op Code: F5 45 34 loads the value FFh into Register CFh. The contents of Register 34h and Register 45h are not affected. Example IIf Working Register R0 contains the value 08h and Register 2Ch (24h + 08h = 2Ch) contains the value 4Fh, the statement: LD R10, 24h(R0) Op Code: C7 A0 24 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 268 loads Working Register R10 with the value 4Fh. The contents of Working Register R0 and Register 2Ch are not affected. Example If Working Register R0 contains the value 0Bh and Working Register R10 contains 83h the statement: LD F0h(R0), R10 Op Code: D7 A0 F0 loads the value 83h into Register FBh (F0h + 0Bh = FBh). Because this is the Interrupt Mask Register, the LOAD statement has the effect of enabling IRQ0 and IRQ1. The contents of Working Registers R0 and R10 are unaffected by the load. Instruction Description UM001602-0904 Z8 CPU User Manual 269 Load Constant LDC dst, src Instruction Format Cycles OPC (Hex) Address Mode dst src OPC dst src 12 C2 r Irr OPC dst src 12 D2 Irr r Operation dst ← src This instruction is used to load a byte constant from program memory into a Working Register, or vice versa. The address of the program memory location is specified by a Working Register Pair. The contents of the source operand are not affected. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Example If Working Register Pair R6 and R7 contain the value 30A2h and program memory location 30A2h contains the value 22h, the statement: LDC R2, @RR6 Op Code: C2 26 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 270 loads the value 22h into Working Register R2. The value of program memory location 30A2h is unchanged by the load. Example If Working Register R2 contains the value 22h, and Working Register Pair R6 and R7 contains the value 10A2h, the statement: LDC @RR6, R2 Op Code: D2 26 loads the value 22h into program memory location 10A2h. The value of Working Register R2 is unchanged by the load. Note: This instruction format is valid only for MCUs which can address external program memory. Instruction Description UM001602-0904 Z8 CPU User Manual 271 Load Constant Autoincrement LDCI dst, src Instruction Format Cycles OPC (Hex) Address Mode dst src OPC dst src 18 C3 Ir Irr OPC dst src 18 D3 Irr Ir Operation dst ← src r ← r + 1 rr ← rr + 1 This instruction is used for block transfers of data between program memory and the Register File. The address of the program memory location is specified by a Working Register Pair, and the address of the Register File location is specified by Working Register. The contents of the source location are loaded into the destination location. Both addresses in the Working Registers are then incremented automatically. The contents of the source operand are not affected. Flag C Z S V D H UM001602-0904 Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Instruction Description Z8 Family of Microcontrollers User Manual 272 Example If Working Register Pair R6–R7 contains 30A2h, program memory location 30A2h and 30A3h contain 22h and BCh respectively, and Working Register R2 contains 20h, the statement: LDCI @R2, @RR6 Op Code: C3 26 loads the value 22h into Register 20h. Working Register Pair RR6 is incremented to 30A3h and Working Register R2 is incremented to 21h. A second LDCI @R2, @RR6 Op Code: C3 26 loads the value BCh into Register 21h. Working Register Pair RR6 is incremented to 30A4h and Working Register R2 is incremented to 22h. Example If Working Register R2 contains 20h, Register 20h contains 22h, Register 21h contains BCh, and Working Register Pair R6–R7 contains 30A2h, the statement: LDCI @RR6, @R2 Op Code: D3 26 loads the value 22h into program memory location 30A2h. Working Register R2 is incremented to 21h and Working Register Pair R6–R7 is incremented to 30A3h. A second LDCI @RR6, @R2 Op Code: D3 26 loads the value BCh into program memory location 30A3h. Working Register R2 is incremented to 22h and Working Register Pair R6–R7 is incremented to 30A4h. Instruction Description UM001602-0904 Z8 CPU User Manual 273 Load External Data LDE dst, src Instruction Format Cycles OPC (Hex) Address Mode dst src OPC dst src 12 82 r Irr OPC src dst 12 92 Irr r Operation dst ← src This instruction is used to load a byte from external data memory into a Working Register or vice versa. The address of the external data memory location is specified by a Working Register Pair. The contents of the source operand are not affected. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Example If Working Register Pair R6 and R7 contain the value 40A2h and external data memory location 40A2h contains the value 22h, the statement: LDE R2, @RR6 Op Code: 82 26 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 274 loads the value 22h into Working Register R2. The value of external data memory location 40A2h is unchanged by the load. Example If Working Register Pair R6 and R7 contain the value 404Ah and Working Register R2 contains the value 22h, the statement: LDE @RR6, R2 Op Code: 92 26 loads the value 22h into external data memory location 404Ah Note: This instruction format is valid only for MCUs which can address external data memory. Instruction Description UM001602-0904 Z8 CPU User Manual 275 Load External Data Autoincrement LDEI dst, src Instruction Format Cycles OPC (Hex) Address Mode dst src OPC dst src 18 83 Ir Irr OPC src dst 18 93 Irr Ir Operation dst ← src r ← r + 1 rr ← rr + 1 This instruction is used for block transfers of data between external data memory and the Register File. The address of the external data memory location is specified by a Working Register Pair, and the address of the Register File location is specified by a Working Register. The contents of the source location are loaded into the destination location. Both addresses in the Working Registers are then incremented automatically. The contents of the source are not affected. Flag C Z S V D H UM001602-0904 Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Instruction Description Z8 Family of Microcontrollers User Manual 276 Example If Working Register Pair R6 and R7 contains 404Ah, external data memory location 404Ah and 404Bh contain ABh and C3h respectively, and Working Register R2 contains 22h, the statement: LDEI @R2, @RR6 Op Code: 83 26 loads the value ABh into Register 22h. Working Register Pair RR6 is incremented to 404Bh and Working Register R2 is incremented to 23h. A second LDEI @R2, @RR6 Op Code: 83 26 loads the value C3h into Register 23h. Working Register Pair RR6 is incremented to 404Ch and Working Register R2 is incremented to 24h. Example If Working Register R2 contains 22h, Register 22h contains ABh, Register 23h contains C3h, and Working Register Pair R6 and R7 contains 404Ah, the statement: LDEI @RR6, @R2 Op Code: 93 26 loads the value ABh into external data memory location 404Ah. Working Register R2 is incremented to 23h and Working Register Pair RR6 is incremented to 404Bh. A second LDEI @RR6, @R2 Op Code: 93 26 loads the value C3h into external data memory location 404Bh. Working Register R2 is incremented to 24h and Working Register Pair RR6 is incremented to 404Ch. Note: This instruction format is valid only for MCUs which can address external data memory. Instruction Description UM001602-0904 Z8 CPU User Manual 277 No Operation NOP Instruction Format OPC Cycles OPC (Hex) 6 FF Operation No action is performed by this instruction. It is typically used for timing delays or clearing the pipeline. Flag C Z S V D H UM001602-0904 Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Instruction Description Z8 Family of Microcontrollers User Manual 278 Logical AND AND dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 42 43 Address Mode dst src r r r lr OPC src dst 10 10 44 45 R R R IR OPC dst src 10 10 46 47 R IR IM IM Operation dst ← dst AND src The source operand is logically ANDed with the destination operand. The AND operation results in a 1 being stored whenever the corresponding bits in the two operands are both 1, otherwise a 0 is stored. The result is stored in the destination operand. The contents of the source bit are not affected. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise Set if the result of bit 7 is set; cleared otherwise Always reset to 0 Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is speci- Instruction Description UM001602-0904 Z8 CPU User Manual 279 fied by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R1 contains 34h (00111000b) and Working Register R14 contains 4Dh (10001101), the statement: AND R1, R14 Op Code: 52 1E Example If Working Register R4 contains F9h (11111001b), Working Register R13 contains 7Bh, and Register 7Bh contains 6Ah (01101010b), the statement: AND R4, @R13 Op Code: 53 4D leaves the value 68h (01101000b) in Working Register R4. The Z, V, and S flags are cleared. Example If Register 3Ah contains the value F5h (11110101b) and Register 42h contains the value 0Ah (00001010), the statement: AND 3Ah, 42h Op Code: 54 42 3A leaves the value 00h (00000000b) in Register 3Ah. The Z Flag is set, and the V and S flags are cleared. Example If Working Register R5 contains F0h (11110000b), Register 45h contains 3Ah, and Register 3Ah contains 7Fh (01111111b), the statement: UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 280 AND R5, @45h Op Code: 55 45 E5 leaves the value 70h (01110000b) in Working Register R5. The Z, V, and S flags are cleared. Example If Register 7Ah contains the value F7h (11110111b), the statement: AND 7Ah, #F0h Op Code: 56 7A F0 leaves the value F0h (11110000b) in Register 7Ah. The S Flag is set, and the Z and V flags are cleared. Example If Working Register R3 contains the value 3Eh and Register 3Eh contains the value ECh (11101100b), the statement: AND @R3, #05h Op Code: 57 E3 05 leaves the value 04h (00000100b) in Register 3Eh. The Z, V, and S flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 281 Logical OR OR dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 02 03 Address Mode dst src r r r lr OPC src dst 10 10 04 05 R R R IR OPC dst src 10 10 06 07 R IR IM IM Operation dst ← dst OR src The source operand is logically ORed with the destination operand and the result is stored in the destination operand. The contents of the source operand are not affected. The OR operation results in a one bit being stored whenever either of the corresponding bits in the two operands is a one. Otherwise, a zero bit is stored. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise Set if the result of bit 7 is set; cleared otherwise Always reset to 0 Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is speci- UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 282 fied by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (Ch) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R1 contains 34h (00111000b) and Working Register R14 contains 4Dh (10001101), the statement: OR R1, R14 Op Code: 42 1E leaves the value BDh (10111101b) in Working Register R1. The S Flag is set, and the Z and V flags are cleared. Example If Working Register R4 contains F9h (11111001b), Working Register R13 contains 7Bh, and Register 7B contains 6Ah (01101010b), the statement: OR R4, @R13 Op Code: 43 4D leaves the value FBh (11111011b) in Working Register R4. The S Flag is set, and the Z and V flags are cleared. Example If Register 3Ah contains the value F5h (11110101b) and Register 42h contains the value 0Ah (00001010), the statement: OR 3Ah, 42h Op Code: 44 42 3A leaves the value FFh (11111111b) in Register 3Ah. The S Flag is set, and the Z and V flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 283 Example If Working Register R5 contains 70h (01110000b), Register 45h contains 3Ah, and Register 3Ah contains 7Fh (01111111b), the statement: OR R5, @45h Op Code: 45 45 E5 leaves the value 7Fh (01111111b) in Working Register R5. The Z, V, and S flags are cleared. Example If Register 7Ah contains the value F3h (11110111b), the statement: OR 7Ah, #F0h Op Code: 46 7A F0 leaves the value F3h (11110111b) in Register 7Ah. The S Flag is set, and the Z and V flags are cleared. Example If Working Register R3 contains the value 3Eh and Register 3Eh contains the value 0Ch (00001100b), the statement: OR @R3, #05h Op Code: 57 E3 05 leaves the value 0Dh (00001101b) in Register 3Eh. The Z, V, and S flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 284 Logical Exclusive OR XOR dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 82 83 Address Mode dst src r r r lr OPC src dst 10 10 84 85 R R R IR OPC dst src 10 10 86 87 R IR IM IM Operation dst ← dst XOR src The source operand is logically EXCLUSIVE ORed with the destination operand. The XOR operation results in a 1 being stored in the destination operand whenever the corresponding bits in the two operands are different, otherwise a 0 is stored. The contents of the source operand are not affected. C Z S V D H Unaffected Set if the result is zero; cleared otherwise. Set if the result of bit 7 is set; cleared otherwise. Always reset to 0 Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, Instruction Description UM001602-0904 Z8 CPU User Manual 285 if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R1 contains 34h (00111000b) and Working Register R14 contains 4Dh (10001101b), the statement: XOR R1, R14 Op Code: B2 1E leaves the value BDh (10111101b) in Working Register R1. The Z, and V flags are cleared, and the S Flag is set. Example If Working Register R4 contains F9h (11111001b), Working Register R13 contains 7Bh, and Register 7Bh contains 6Ah (01101010b), the statement: XOR R4, @R13 Op Code: B3 4D leaves the value 93h (10010011b) in Working Register R4. The S Flag is set, and the Z, and V flags are cleared. Example If Register 3Ah contains the value F5h (11110101b) and Register 42h contains the value 0Ah (00001010b), the statement: XOR 3Ah, 42h Op Code: B4 42 3A leaves the value FFh (11111111b) in Register 3Ah. The S Flag is set, and the C and V flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 286 Example If Working Register R5 contains F0h (11110000b), Register 45h contains 3Ah, and Register 3Ah contains 7Fh (01111111b), the statement: XOR R5, @45h Op Code: B5 45 E5 leaves the value 8Fh (10001111b) in Working Register R5. The S Flag is set, and the C and V flags are cleared. Example If Register 7Ah contains the value F7h (11110111b), the statement: XOR 7Ah, #F0h Op Code: B6 7A F0 leaves the value 07h (00000111b) in Register 7Ah. The Z, V and S flags are cleared. Example If Working Register R3 contains the value 3Eh and Register 3Eh contains the value 6Ch (01101100b), the statement: XOR @R3, #05h Op Code: B7 E3 05 leaves the value 69h (01101001b) in Register 3Eh. The Z, V, and S flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 287 Pop POP dst Instruction Format OPC dst Cycles 10 10 OPC (Hex) 50 51 Address Mode dst R IR Operation dst ← @SP SP ← SP + 1 The contents of the location specified by the SP (Stack Pointer) are loaded into the destination operand. The SP is then incremented automatically. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E UM001602-0904 dst Instruction Description Z8 Family of Microcontrollers User Manual 288 Example If the SP (Control Registers FEh and FFh) contains the value 70h and Register 70h contains 44h, the statement: POP 34h Op Code: 50 34 loads the value 44h into Register 34h. After the POP operation, the SP contains 71h. The contents of Register 70 are not affected. Example If the SP (Control Registers FEh and FFh) contains the value 1000h, external data memory location 1000h contains 55h, and Working Register R6 contains 22h, the statement: POP @R6 Op Code: 51 E6 loads the value 55h into Register 22h. After the POP operation, the SP contains 1001h. The contents of Working Register R6 are not affected. Instruction Description UM001602-0904 Z8 CPU User Manual 289 Push PUSH src Instruction Format OPC src Cycles 10 Internal Stack 12 External Stack 10 Internal Stack 10 External Stack OPC (Hex) 70 Address Mode dst R IR 71 Operation SP ← SP–1 @SP ← src The contents of the SP (stack pointer) are decremented by one, then the contents of the source operand are loaded into the location addressed by the decremented SP, thus adding a new element to the stack. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E UM001602-0904 dst Instruction Description Z8 Family of Microcontrollers User Manual 290 Example If the SP contains 1001h, the statement: PUSH FCh Op Code: 70 FC stores the contents of Register FCh (the Flag Register) in location 1000h. After the PUSH operation, the SP contains 1000h. Example If the SP contains 61h and Working Register R4 contains FCh, the statement: PUSH @R4 Op Code: 71 E4 stores the contents of Register FCh (the Flag Register) in location 60h. After the PUSH operation, the SP contains 60h. Instruction Description UM001602-0904 Z8 CPU User Manual 291 Reset Carry Flag RCF Instruction Format OPC Cycles OPC (Hex) 6 CF Operation C ← 0 The C Flag is reset to 0, regardless of its previous value. Flag C Z S V D H Description Reset to 0 Unaffected Unaffected Unaffected Unaffected Unaffected Example If the C Flag is currently set, the statement: RCF Op Code: CF resets the Carry Flag to 0. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 292 Return RET Instruction Format Cycles OPC (Hex) 14 AF OPC Operation PC ← @SP SP ← SP + 2 This instruction is normally used to return from a procedure entered by a CALL instruction. The contents of the location addressed by the SP are popped into the PC. The next statement executed is the one addressed by the new contents of the PC. The stack pointer is also incremented by two. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: Each PUSH instruction executed within the subroutine should be countered with a POP instruction in order to guarantee the SP is at the correct location when the RET instruction is executed. Otherwise the wrong address will be loaded into the PC and the program will not operate as appropriate . Instruction Description UM001602-0904 Z8 CPU User Manual 293 Example If SP contains 2000h, external data memory location 2000h contains 18h, and location 2001h contains B5h, the statement: RET Op Code: AF leaves the value 2002h in the SP, and the PC contains 18B5h, the address of the next instruction to be executed. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 294 Rotate Left RL dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) 90 91 Address Mode dst R IR Operation C ← dst(7) dst(0) ← dst(7) dst(1) ← dst(0) dst(2) ← dst(1) dst(3) ← dst(2) dst(4) ← dst(3) dst(5) ← dst(4) dst(6) ← dst(5) dst(7) ← dst(6) The contents of the destination operand are rotated left by one bit position. The initial value of bit 7 is moved to the bit 0 position and also into the Carry Flag, as shown below. C Instruction Description D7 D6 D5 D4 D3 D2 D1 D0 UM001602-0904 Z8 CPU User Manual 295 Flag C Z S V D H Description Set if the bit rotated from the most significant bit position was 1 ( i.e., bit 7 was 1). Set if the result is zero; cleared otherwise. Set if the result in bit 7 is set; cleared otherwise. Set if arithmetic overflow occurred (if the sign of the destination operand changed during rotation); cleared otherwise. Unaffected. Unaffected. Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the contents of Register C6h are 88h (10001000b), the statement: RL C6h Op Code: 80 C6 leaves the value 11h (00010001b) in Register C6h. The C and V Flags are set, and the S and Z flags are cleared. Example If the contents of Register C6h are 88h, and the contents of Register 88h are 44h (01000100b), the statement: RL @C6h Op Code: 81 C6 leaves the value 88h in Register 88h (10001000b). The S and V Flags are set, and the C and Z flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 296 Rotate Left Through Carry RLC dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) 10 11 Address Mode dst R IR Operation C← dst(7) dst(0) ← C dst(1) ← dst(0) dst(2) ← dst(1) dst(3) ← dst(2) dst(4) ← dst(3) dst(5) ← dst(4) dst(6) ← dst(5) dst(7) ← dst(6) The contents of the destination operand along with the C Flag are rotated left by one bit position. The initial value of bit 7 replaces the C Flag and the initial value of the C Flag replaces bit 0, as shown below. C Instruction Description D7 D6 D5 D4 D3 D2 D1 D0 UM001602-0904 Z8 CPU User Manual 297 Flag C Z S V D H Description Set if the bit rotated from the most significant bit position was 1 (i.e., bit 7 was 1). Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Set if arithmetic overflow occurred (if the sign of the destination operand changed during rotation); cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the C Flag is reset and Register C6 contains 8Fh (10001111b), the statement: RLC C6 Op Code: 10 C6 leaves Register C6 with the value 1Eh (00011110b). The C and V Flags are set, and S and Z flags are cleared. Example If the C Flag is reset, Working Register R4 contains C6h, and Register C6 contains 8Fh (10001111b), the statement: RLC @R4 Op Code: 11 E4 leaves Register C6 with the value 1Eh (00011110b). The C and V Flags are set, and S and Z flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 298 Rotate Right RR dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) E0 E1 Address Mode dst R IR Operation C ← dst(0) dst(0) ← dst(1) dst(1) ← dst(2) dst(2) ← dst(3) dst(3) ← dst(4) dst(4) ← dst(5) dst(5) ← dst(6) dst(6) ← dst(7) dst(7) ← dst(0) The contents of the destination operand are rotated to the right by one bit position. The initial value of bit 0 is moved to bit 7 and also into the C Flag, as shown below. D7 D6 D5 D4 D3 D2 D1 D0 Instruction Description C UM001602-0904 Z8 CPU User Manual 299 Flag C Z S V D H Description Set if the bit rotated from the least significant bit position was 1 ( i.e., bit 0 was 1). Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Set if arithmetic overflow occurred (if the sign of the destination operand changed during rotation); cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the contents of Working Register R6 are 31h (00110001B), the statement: RR R6 Op Code: E0 E6 leaves the value 98h (10011000) in Working Register R6. The C, V, and S Flags are set, and the Z Flag is cleared. Example If the contents of Register C6 are 31h and the contents of Register 31h are 7Eh (01111110b), the statement: RR @C6 Op Code: E1 C6 leaves the value 4Fh (00111111) in Register 31h. The C, Z, V, and S flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 300 Rotate Right Through Carry RRC dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) C0 C1 Address Mode dst R IR Operation C ← dst(0) dst(0) ← dst(1) dst(1) ← dst(2) dst(2) ← dst(3) dst(3) ← dst(4) dst(4) ← dst(5) dst(5) ← dst(6) dst(6) ← dst(7) dst(7) ← C The contents of the destination operand with the C Flag are rotated right by one bit position. The initial value of bit 0 replaces the C Flag and the initial value of the C Flag replaces bit 7, as shown below. D7 D6 D5 D4 D3 D2 D1 D0 Instruction Description C UM001602-0904 Z8 CPU User Manual 301 Flag C Z S V D H Description Set if the bit rotated from the least significant bit position was 1 (i.e., bit 0 was 1). Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Set if arithmetic overflow occurred (if the sign of the destination operand changed during rotation); cleared otherwise. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the contents of Register C6h are DDh (11011101b) and the C Flag is reset, the statement: RRC C6h Op Code: C0 C6 leaves the value 6Eh (01101110b) in register C6h. The C and V Flags are set, and the Z and S flags are cleared. Example If the contents of Register 2Ch are EDh, the contents of Register EDh is ← (00000000b), and the C Flag is reset, the statement: RRC @2Ch Op Code: C1 2C leaves the value 02h (00000010b) in Register EDh. The C, Z, S, and V Flags are reset. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 302 Set Carry Flag SRC Instruction Format OPC Cycles OPC (Hex) 6 DF Operation C ← 1 The C Flag is set to 1, regardless of its previous value. Flag C Z S V D H Description Set to 1 Unaffected Unaffected Unaffected Unaffected Unaffected Example If the C Flag is currently reset, the statement: SCF Op Code: DF sets the Carry Flag to 1. Instruction Description UM001602-0904 Z8 CPU User Manual 303 Set Register Pointer SRP src Instruction Format OPC Cycles OPC (Hex) Address Mode dst 6 31 IM src Operation RP ← src The specified value is loaded into the Register Pointer (RP) (Control Register FDh). Bits 7-4 determine the Working Register Group. Bits 3-0 selects the Expanded Register Bank. Addressing of un-implemented Working Register Group, while using Expanded Register Banks, will point to Bank 0. Example SRP TD addresses Working Register Group 7 of Bank 0. Register Pointer (FDh) Contents (Bin) 1111 0000 1110 0000 1101 0000 1100 0000 1011 0000 1010 0000 1001 0000 UM001602-0904 Working Register Group (Hex) F E D C B A 9 Actual Registers (Hex) F0–FF E0–EF D0–DF C0–CF B0–BF A0–AF 90–9F Instruction Description Z8 Family of Microcontrollers User Manual 304 Register Pointer (FDh) Contents (Bin) 1000 0000 0111 0000 0110 0000 0101 0000 0100 0000 0011 0000 0010 0000 0001 0000 0000 0000 Working Register Group (Hex) 8 7 6 5 4 3 2 1 0 Register Pointer (FDh) Contents (Hex) xxxx 1111 xxxx 1110 xxxx 1101 xxxx 1100 xxxx 1011 xxxx 1010 xxxx 1001 xxxx 1000 xxxx 0111 xxxx 0110 xxxx 0101 xxxx 0100 xxxx 0011 xxxx 0010 Instruction Description Actual Registers (Hex) 80–8F 70–7F 60–6F 50–5F 40–4F 30–3F 20–2F 10–1F 00–0F Expanded Register Bank (Hex) F E D C B A 9 8 7 6 5 4 3 2 UM001602-0904 Z8 CPU User Manual 305 Register Pointer (FDh) Contents (Hex) xxxx 0001 xxxx 0000 Flag C Z S V D H Expanded Register Bank (Hex) 1 0 Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: When an Expanded Register Bank , other than Bank 0 is selected, access to the Z8® Standard Register File is possible except for the Port Register and general purpose registers 04h to 0Fh. fpr Register Addresses 0h to Fh Example The statement: SRP F0h Op Code: 31 F0 sets the Register Pointer to access expanded Register Bank 0 and Working Register Group F in the Z8® Standard Register File. All references to Working Registers now affect this group of 16 registers. Registers F0h to FFh can be accessed as Working Registers R0 to R15. Example The statement: SRP 0Fh Op Code: 31 0F UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 306 sets the Register Pointer to access Expanded Register Bank F, Reg ← to Reg 0Fh, as the current Working Registers. All references to Working Registers now affect this group of 16 registers. These registers are now accessed as Working Registers R0 to R15. Port Registers are now not accessable. Example Assume the RP currently addresses the Control and Peripheral Working Register Group and the program has just entered an interrupt service routine. The statement: SRP 70h Op Code: 31 70 retains the contents of the Control and Peripheral Registers by setting the RP to 70h (01110000b). Any reference to Working Registers in the interrupt routine will point to registers 70h to 7Fh. Instruction Description UM001602-0904 Z8 CPU User Manual 307 Shift Right Arithmetic SRA dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) D0 D1 Address Mode dst R IR Operation C ← dst(0) dst(0) ← dst(1) dst(1) ← dst(2) dst(2) ← dst(3) dst(3) ← dst(4) dst(4) ← dst(5) dst(5) ← dst(6) dst(6) ← dst(7) dst(7) ← dst(7) An arithmetic shift right by one bit position is performed on the destination operand. Bit 0 replaces the C Flag. Bit 7 (the Sign bit) is unchanged and its value is shifted into bit 6, as shown below. D7 D6 D5 D4 D3 D2 D1 D0 UM001602-0904 C Instruction Description Z8 Family of Microcontrollers User Manual 308 Flag C Z S V D H Description Set if the bit rotated from the least significant bit position was 1 (i.e., bit 0 was 1). Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Always reset to 0. Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If the contents of Working Register R6 are 31h (00110001B), the statement: SRA R6 Op Code: D0 E6 leaves the value 98h (00011000) in Working Register R6. The C Flag is set, and the Z, V, and S flags are cleared. Example If Register C6 contains the value DFh, and Register DFh contains the value B8h (10111000B), the statement: SRA @C6 Op Code: D1 C6 leaves the value DCh (11011100B) in Register DFh. The C, Z, and V Flags are reset, and the S Flag is set. Instruction Description UM001602-0904 Z8 CPU User Manual 309 Stop STOP Instruction Format Cycles OPC (Hex) 6 6F OPC Operation This instruction turns off the internal system clock (SCLK) and external crystal (XTAL) oscillation, and reduces the standby current. STOP mode is terminated by a RESET which causes the processor to restart the application program at address 000Ch. Flag C Z S V D H Description Unaffected Unaffected Unaffected Unaffected Unaffected Unaffected Note: In order to enter STOP mode, it is necessary to first flush the instruction pipeline to avoid suspending execution in mid-instruction. The user must execute a NOP immediately before the execution of the STOP instruction. Example The statements: NOP STOP Op Codes: FF 6F place the Z8® CPU into STOP mode. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 310 Subtract SUB dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 22 23 Address Mode dst src r r r lr OPC src dst 10 10 24 25 R R R IR OPC dst src 10 10 26 27 R IR IM IM Operation dst ← dst–src The source operand is subtracted from the destination operand and the result is stored in the destination operand. The contents of the source operand are not affected. Subtraction is performed by adding the two’s complement of the source operand to the destination operand. Flag C Z V S H D Instruction Description Description Cleared if there is a carry from the most significant bit of the result; set otherwise, indicating a borrow. Set if the result is 0; cleared otherwise. Set if arithmetic overflow occurred (if the operands were of opposite sign and the sign of the result is the same as the sign of the source); reset otherwise. Set if the result is negative; cleared otherwise. Cleared if there is a carry from the most significant bit of the low order four bits of the result; set otherwise indicating a borrow. Always set to 1. UM001602-0904 Z8 CPU User Manual 311 Address modes R or IR can be used to specify a 4-bit Working Register. In Note: this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example ]If Working Register R3 contains 16h, and Working Register R11 contains 20h, the statement: SUB R3, R11 Op Code: 22 3B leaves the value F6h in Working Register R3. The C, S, and D Flags are set, and the Z, V, and H flags are cleared. Example If Working Register R15 contains 16h, Working Register R10 contains 20h, and Register 20h contains 11h, the statement: SUB R16, @R10 Op Code: 23 FA leaves the value 05h in Working Register R15. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register 34h contains 2Eh, and Register 12h contains 1Bh, the statement: SUB 34h, 12h Op Code: 24 12 34 leaves the value 13h in Register 34h. The D Flag is set, and the C, Z, S, V, and H flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 312 Example If Register 4Bh contains 82h, Working Register R3 contains 10h, and Register 10h contains 01h, the statement: SUB 4Bh, @R3 Op Code: 25 E3 4B leaves the value 81h in Register 4Bh. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register 6Ch contains 2Ah, the statement: SUB 6Ch, #03h Op Code: 26 6C 03 leaves the value 27h in Register 6Ch. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register D4h contains 5Fh, Register 5Fh contains 4Ch, the statement: SUB @D4h, #02h Op Code: 17 D4 02 leaves the value 4Ah in Register 5Fh. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 313 Subtract With Carry SBC dst, src Instruction Format OPC dst src Cycles 6 6 OPC (Hex) 32 33 Address Mode dst src r r r lr OPC src dst 10 10 34 35 R R R IR OPC dst src 10 10 36 37 R IR IM IM Operation dst ← dst–src–C The source operand, along with the setting of the C Flag, is subtracted from the destination operand and the result is stored in the destination operand. The contents of the source operand are not affected. Subtraction is performed by adding the two’s complement of the source operand to the destination operand. In multiple precision arithmetic, this instruction permits the carry (borrow) from the subtraction of low order operands to be subtracted from the subtraction of high order operands. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 314 Flag C Z V S H D Description Cleared if there is a carry from the most significant bit of the result; set otherwise, indicating a borrow. Set if the result is 0; cleared otherwise. Set if arithmetic overflow occurred (if the operands were of opposite sign and the sign of the result is the same as the sign of the source); reset otherwise. Set if the result is negative; cleared otherwise. Cleared if there is a carry from the most significant bit of the low order four bits of the result; set otherwise indicating a borrow. Always set to 1. Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example Working Register R3 contains 16h, the C Flag is set to 1, and Working Register R11 contains 20h, the statement: SBC R3, R11 Op Code: 32 3B leaves the value F5h in Working Register R3. The C, S, and D Flags are set, and the Z, V, and H Flags are all cleared. Example If Working Register R15 contains 16h, the C Flag is not set, Working Register R10 contains 20h, and Register 20h contains 11h, the statement: SBC R16, @R10 Op Code: 33 FA Instruction Description UM001602-0904 Z8 CPU User Manual 315 leaves the value 05h in Working Register R15. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example :If Register 34h contains 2Eh, the C Flag is set, and Register 12h contains 1Bh, the statement: SBC 34h, 12h Op Code: 34 12 34 leaves the value 13h in Register 34h. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register 4Bh contains 82h, the C Flag is set, Working Register R3 contains 10h, and Register 10h contains 01h, the statement: SBC 4Bh, @R3 Op Code: 35 E3 4B leaves the value 80h in Register 4Bh. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register 6Ch contains 2Ah, and the C Flag is not set, the statement: SBC 6Ch, #03h Op Code: 36 6C 03 leaves the value 27h in Register 6Ch. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Example If Register D4h contains 5Fh, Register 5Fh contains 4Ch, and the C Flag is set, the statement: SBC @D4h, #02h Op Code: 37 D4 02 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 316 leaves the value 4Ah in Register 5Fh. The D Flag is set, and the C, Z, S, V, and H flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 317 Swap Nibbles SWAP dst Instruction Format OPC dst Cycles 6 6 OPC (Hex) F0 F1 Address Mode dst R IR Operation dst(7-4) ↔ dst(3-0) The contents of the lower four bits and upper four bits of the destination operand are swapped. Flag C Z S V D H Description Unaffected Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Undefined Unaffected Unaffected Note: Address modes R or IR can be used to specify a 4-bit Working Register. In this format, destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E dst Example If Register BCh contains B3h (10110011B), the statement: UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 318 SWAP B3h Op Code: F0 B3 will leave the value 3Bh (00111011B) in Register BCh. The Z and S flags are cleared. Example If Working Register R5 contains BCh and Register BCh contains B3h (10110011B), the statement: SWAP @R5h Op Code: F1 E5 will leave the value 3Bh (00111011B) in Register BCh. The Z and S flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 319 Test Complement Under Mask TCM dst, src Instruction Format Cycles 6 6 OPC (Hex) 62 63 Address Mode dst src r r r lr OPC dst src OPC src dst 10 10 64 65 R R R IR OPC dst src 10 10 66 67 R IR IM IM Operation (NOT dst) AND src This instruction tests selected bits in the destination operand for a logical 1 value. The bits to be tested are specified by setting a 1 bit in the corresponding bit position in the source operand (the mask). The TCM instruction complements the destination operand, and then ANDs it with the source mask (operand). The Zero (Z) Flag can then be checked to determine the result. If the Z Flag is set, then the tested bits were 1. When the TCM operation is complete, the destination and source operands still contain their original values. Flag Z S V D H UM001602-0904 Description Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Always reset to 0. Unaffected Unaffected Instruction Description Z8 Family of Microcontrollers User Manual 320 Address modes R or IR can be used to specify a 4-bit Working Register. In Note: this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R3 contains 45h (01000101b) and Working Register R7 contains the value 01h (00000001b) (bit 0 is being tested if it is 1), the statement: TCM R3, R7 Op Code: 62 37 will set the Z Flag indicating bit 0 in the destination operand is 1. The V and S flags are cleared. Example If Working Register R14 contains the value F3h (11110011b), Working Register R5 contains CBh, and Register CBh contains 88h (10001000b) (bit 7 and bit 3 are being tested if they are 1), the statement: TCM R14, @R5 Op Code: 63 E5 will reset the Z Flag, because bit 3 in the destination operand is not a 1. The V and S Flags are also cleared. Example If Register D4h contains the value 04h (000001000b), and Working Register R0 contains the value 80h (10000000b) (bit 7 is being tested if it is 1), the statement: TCM D4h, R0 Op Code: 64 E0 D4 Instruction Description UM001602-0904 Z8 CPU User Manual 321 will reset the Z Flag, because bit 7 in the destination operand is not a 1. The S flag will be set, and the V flag will be cleared. Example If Register DFh contains the value FFh (11111111b), Register 07h contains the value 1Fh, and Register 1Fh contains the value BDh (10111101b) (bit 7, bit 5, bit 4, bit 3, bit 2, and bit 0 are being tested if they are 1), the statement: TCM DFh, @07h Op Code: 65 07 DF will set the Z Flag indicating the tested bits in the destination operand are 1. The S and V flags are cleared. Example If Working Register R13 contains the value F2h (11110010b), the statement: TCM R13, #02h Op Code: 66 ED, 02 tests bit 1 of the destination operand for 1. The Z flag will be set indicating bit 1 in the destination operand was 1. The S and V flags are cleared. Example If Register 5Dh contains A0h, and Register A0h contains 0Fh (00001111b), the statement: TCM @5D, #10h Op Code: 67 5D 10 tests bit 4 of the Register A0h for 1. The Z flag will be reset indicating bit 1 in the destination operand was not 1. The S and V flags are cleared. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 322 Test Under Mask TM dst, src Instruction Format Cycles 6 6 OPC (Hex) 72 73 Address Mode dst src r r r lr OPC dst src OPC src dst 10 10 74 75 R R R IR OPC dst src 10 10 76 77 R IR IM IM Operation dst AND src This instruction tests selected bits in the destination operand for a 0 logical value. The bits to be tested are specified by setting a 1 bit in the corresponding bit position in the source operand (the mask). The TM instruction ANDs the destination operand with the source operand (the mask). The Zero (Z) Flag can then be checked to determine the result. If the Z Flag is set, then the tested bits were 0. When the TM operation is complete, the destination and source operands still contain their original values. Flag Z S V D H Instruction Description Description Set if the result is zero; cleared otherwise. Set if the result bit 7 is set; cleared otherwise. Always reset to 0. Unaffected Unaffected UM001602-0904 Z8 CPU User Manual 323 Address modes R or IR can be used to specify a 4-bit Working Register. In Note: this format, the source or destination Working Register operand is specified by adding 1110b (Eh) to the high nibble of the operand. For example, if Working Register R12 (CH) is the destination operand, then ECh will be used as the destination operand in the Op Code. E src or E dst Example If Working Register R3 contains 45h (01000101b) and Working Register R7 contains the value 02h (00000010b) (bit 1 is being tested if it is 0), the statement: TM R3, R7 Op Code: 72 37 will set the Z Flag indicating bit 1 in the destination operand is 0. The V and S flags are cleared. Example Working Register R14 contains the value F3h (11110011b), Working Register R5 contains CBh, and Register CBh contains 88h (10001000b) (bit 7 a bit 3 are being tested if they are 0), the statement: TM R14, @R5 Op Code: 73 E5 will reset the Z Flag, because bit 7 iin the destination operand is not a 0. The S flag will be set, and the V Flag is cleared. Example If Register D4h contains the value 08h (00001000b), and Working Register R0 contains the value 04h (00000100b) (bit 2 is being tested if it is 0), the statement: TM D4h, R0 Op Code: 74 E0 D4 UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 324 will set the Z Flag, because bit 2 in the destination operand is a 0. The S and V Flags will be cleared. Example If Register DFh contains the value ← (00000000b), Register 07h contains the value 1Fh, and Register 1Fh contains the value BDh (10111101b) (bit 7, bit 5, bit 4, bit 3, bit 2, and bit 0 are being tested if they are 0), the statement: TM DFh, @07h Op Code: 75 07 DF will set the Z Flag indicating the tested bits in the destination operand are 0. The S is set, and the V Flag is cleared. Example If Working Register R13 contains the value F1h (11110001b), the statement: TM R13, #02h Op Code: 76 ED, 02 tests bit 1 of the destination operand for 0. The Z flag will be set indicating bit 1 in the destination operand was 0. The S and V flags are cleared. Example If Register 5Dh contains A0h, and Register A0h contains 0Fh (00001111b), the statement: TM @5D, #10h Op Code: 77 5D 10 tests bit 4 of the Register A0h for 0. The Z flag will be set indicating bit 4 in the destination operand was 0. The S and V flags are cleared. Instruction Description UM001602-0904 Z8 CPU User Manual 325 Watch-Dog Timer WDT Instruction Format OPC Cycles OPC (Hex) 6 5F Operation The WDT (Watch–Dog Timer) is a retriggerable one shot timer that will reset the Z8® CPU if it reaches its terminal count. The WDT is initially enabled by executing the WDT instruction. Each subsequent execution of the WDT instruction refreshes the timer and prevents the WDT from timing out. Flag Z S V D H Description Undefined Undefined Undefined Unaffected Unaffected Note: The WDT instruction should not be used following any instruction in which the condition of the flags is important. Example If the WDT is enabled, the statement: WDT Op Code: .BYTE 5Fh refreshes the Watch–Dog Timer. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 326 Example The first execution of the statement: WDT Op Code: .BYTE 5Fh enables the Watch–Dog Timer. Instruction Description UM001602-0904 Z8 CPU User Manual 327 Watch-Dog Timer Enable During Halt Mode WDh Instruction Format OPC Cycles OPC (Hex) 6 4F Operation When this instruction is executed it will enable the WDT (Watch–Dog Timer) during HALT mode. If this instruction is not executed the WDT will stop when entering HALT mode. This instruction does not clear the counter, it just makes it possible to have the WDT function running during HALT mode. A WDh instruction executed without executing WDT (5Fh) has no effect. Flag Z S V D H Description Undefined Undefined Undefined Unaffected Unaffected Note: The WDh instruction should not be used following any instruction in which the condition of the flags is important. Example If the WDT is enabled, the statement: WDh Op Code: .BYTE 4Fh will enable the WDT in HALT mode. UM001602-0904 Instruction Description Z8 Family of Microcontrollers User Manual 328 Note: This instruction format is valid only for the Z86C04, Z86C08, Z86E04, Z86E07, and Z86E08 MCUs. Instruction Description UM001602-0904 Z8 CPU User Manual 329 Customer Feedback If you note any inaccuracies while reading this Reference Manual, please copy and complete this form, then mail or fax it to ZiLOG (see Return Information, below). We also welcome your suggestions! Product Information Z8 CPU Serial # or Board Fab #/Rev. # Software Version 1.1.0 Document Number UM001602-0904 Host Computer Description/Type Customer Information Name Country Company Phone Address Fax City/State/Zip E-Mail Return Information 532 Race Street San Jose, CA 95126-3432 Telephone: 408.558.8500 Fax: 408.558.8300 ZiLOG Customer Support Problem Description or Suggestion Provide a complete description of the problem or your suggestion. If you are reporting a specific problem, include all steps leading up to the occurrence of the problem. Attach additional pages as necessary. UM001602-0904 Customer Feedback