Enclosed Switch ZC-@55 CSM_ZC-_55_DS_E_2_1 Small, High-precision Enclosed Switch • Small, High-precision Enclosed Switches with Built-in Basic Switches for High Repeatability and Durability of 10 Million Operations Minimum. • Same mounting pitch as Z Basic Switch. • Requires less operating force than conventional limit switches. • Lineup includes modes with operation indicators for easy maintenance and inspection. • Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.) Be sure to read Safety Precautions on page 7 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend ZC-@55 (1) (1) Actuator D: Q: Q22: Q21: N22: N21: W: W1: W2: W21: W3: W31: Plunger Panel mount plunger Panel mount roller plunger Panel mount crossroller plunger Sealed roller plunger Sealed crossroller plunger Short hinge lever Hinge lever Short hinge roller lever Hinge roller lever One-way action short hinge roller lever One-way action hinge roller lever Ordering Information Actuator Model Approved Standards UL CSA EN Plunger ZC-D55 ● ● ● Panel mount plunger ZC-Q55 ● ● ● Panel mount roller plunger ZC-Q2255 ● ● ● Panel mount crossroller plunger ZC-Q2155 ● ● ● Sealed roller plunger ZC-N2255 ● ● ● Sealed crossroller plunger ZC-N2155 ● ● ● Short hinge lever ZC-W55 ● ● ● Hinge lever ZC-W155 ● ● ● Short hinge roller lever ZC-W255 ● ● ● Hinge roller lever ZC-W2155 ● ● ● One-way action short hinge roller lever ZC-W355 ● ● ● One-way action hinge roller lever ZC-W3155 ● ● ● Note: 1. Use molded terminal models when using the Switch under one of the following conditions: a) dusty, b) high amount of dripping oil, or c) high humidity. 2. Models are available with lead outlets in three positions: right-hand, left-hand, and underside. 1 ZC-@55 Specifications Approved Standards Agency Standard UL* UL508 File No. E76675 TÜV Rheinland EN60947-1, EN60947-5-1 J50041904 CCC(CQC) GB14048.5 2003010303077620 Note: Ask your OMRON representative for information on approved models. * UL certified for CSA C22.2 No. 14. Ratings Rated voltage 125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Inrush current Approved Standard Ratings Non-inductive load (A) Resistive load Lamp load NC NO NC NO 10 3 1.5 10 2.5 1.25 1.5 3 10 1.5 3 10 1.5 3 6 0.4 0.4 0.5 0.2 0.2 0.25 NC NO Inductive load (A) Inductive load Motor load NC NO NC NO 10 5 2.5 10 3 1.5 2.5 5 6 2.5 5 6 2.5 5 5 0.05 0.05 0.05 0.03 0.03 0.03 UL/CSA A300 120 VAC 240 VAC Volt-amperes (VA) Make Break Current (A) Carry current Voltage Make 60 30 10A Break 6 3 7,200 720 TÜVRheinland (EN60947-1, EN60947-5-1), CCC (GB14048.5) Applicable category and ratings AC-12 10 A/250 VAC 30 A max. 15 A max. Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The above ratings were tested under the following conditions according. (1) Ambient temperature:+20±2°C (2) Ambient humidity: 65±5%RH (3) Operating frequency:20 operations/min. Characteristics Degree of protections 10,000,000 operations min. Electrical 500,000 operations min. 10,000 7,000 5,000 0.05 mm/s to 0.5 m/s *1 3,000 Mechanical 120 operations/min Electrical 20 operations/min Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 15 mΩ max. (initial value for the builtin switch when tested alone) Dielectric strength Between non-continuous terminals 1,000 VAC, 50/60 Hz for 1 min Between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min Rated insulation voltage (Ui) 1,000 VAC Pollution degree (operating environment) 3 (IEC947-5-1) Short-circuit protective device 10 A-fuse type gG (IEC 60269) Protection against electric shock Class II Proof tracking index (PTI) 175 Switch category D (IEC335) Rated operating current (Ie) 10 A Rated operating voltage (Ue) 250 VAC Vibration Malfunction resistance 10 to 55 Hz, 1.5-mm double amplitude *2 Destruction Shock resistance Malfunction Durability (×104 operations) Mechanical Operating speed Operating frequency Electrical Durability 125 VAC cosφ=1 125 VAC cosφ=0.4 250 VAC cosφ=1 1,000 700 500 250 VAC cosφ=0.4 300 100 70 50 Operating temperature: +20±2°C Operating humidity: 65±5%RH Operating frequency: 20 operations/min 30 10 0 2 4 6 8 10 12 Switching current (A) 1,000 m/s2 max. 300 m/s2 max. (in case of plunger model) *1 *2 Ambient operating temperature −10°C to +80°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 92 g (in case of ZCQ22(21)55) *1. Only for models with plungers. (Contact your OMRON representative for information on other models.) *2. Less than 1 ms under a free state at the operating limits. Mechanical Durability (for ZC-Q55) 10,000 7,000 5,000 3,000 Durability (×104 operations) Durability Engineering Data IP67 1,000 700 500 300 100 70 50 Operating temperature: +20±2˚C Operating humidity: 65±5%RH No load Operating frequency: 120 operations/min 30 0 0.1 0.3 0.5 0.7 1 3 5 7 10 OT (mm) 2 ZC-@55 Structure and Nomenclature Structure Contact Form Changing the Terminal Protective Cover around allows the cable to be pulled out from either the right or the left. (COM)1 2(NC) Roller 4(NO) Plunger Case NC fixed contact Moving contact Switch NO fixed contact Seal rubber Packing Terminal Protective Cover Common Normally Normally terminal open closed terminal (NC) (COM) terminal (NO) Note: M4 binding head screws (with toothed washers) are used as the terminal screws. Dimensions and Operating Characteristics Plunger ZC-D55 (Unit: mm) Panel Mount Plunger ZC-Q55 53.4 A PT 14 dia. 7.8 dia.*1 53.4 23.3 A PT Two M14 × 1 hexagon nuts *3 14 23.3 7.8 dia. * 12.5 *2 8 14 OP OP 21 21 19 5 (10) 22 max.18.3 25.4±0.15 (10) 22 max.18.3 25.4±0.15 (21 × 15 55 Terminal Protective Cover 19 5 Two, 4.3±0.1 dia. mounting holes 21.7 (21 × 21) 15 55 Terminal protective cover Two, 4.3±0.1 dia. mounting holes (NBR) 21.7 Seal rubber (NBR) *1. Stainless steel plunger *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 *Stainless steel plunger Note: Do not use the M14 mounting screw and the case mounting hole at the same time. Panel Mount Roller Plunger 53.4 ZC-Q2255 A PT 23.3 12.5 (3.6) Two M14 × 1 hexagon nuts *3 14 OP 21 19 5 12.5 (2.25) *2 21 19 5 (10) 22 max.18.3 11 dia. × 4.7 *1 14 Two M14 × 1 hexagon nuts *3 (2.25) *2 23.3 Set position indication line (3.6) OP Panel Mount Crossroller Plunger position 53.4 ZC-Q2155 PT Set indication line A 11 dia. × 4.7 *1 (10) 22 max.18.3 25.4±0.15 (21 × 21) 15 55 Terminal protective cover Two, 4.3±0.1 dia. mounting holes 21.7 25.4±0.15 Seal rubber (NBR) *1. Stainless sintered alloy roller *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 23.3 A PT 14 OP 23.3 14 Rubber boot (chloroprene rubber) 22 max.18.3 55 9.5 dia. × 4.7 * 19 19 5 (10) 25.4±0.15 Seal rubber (NBR) OP 5 Terminal protective cover * Stainless sintered alloy roller (21 × 21) 21.7 not use the M14 mounting screw and the case mounting hole at the same time. Sealed Crossroller Plunger ZC-N2155 53.4 9.5 dia. × 4.7 * Rubber boot (chloroprene rubber) 53.4 A PT Two, 4.3±0.1 dia. mounting holes *1. Stainless sintered alloy roller *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 Note: Do Note: Do not use the M14 mounting screw and the case mounting hole at the same time. Sealed Roller Plunger ZC-N2255 15 55 Terminal protective cover 15 Two, 4.3±0.1 dia. mounting holes (10) 22 max.18.3 25.4±0.15 (21 × 21) 21.7 Seal rubber (NBR) Terminal protective cover * Stainless sintered alloy roller 55 15 Two, 4.3±0.1 dia. mounting holes (21 × 21) 21.7 Seal rubber (NBR) Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. Operating characteristics are for when the Switch is operated from direction A. 3 ZC-@55 Short Hinge Roller Lever ZC-W55 53.4 34.6 Hinge Lever ZC-W155 53.4 34.6 14 t=1 * A 50R OP 22.5 5 70R A OP 22.5 (10) 22 max.18.3 25.4±0.15 Short Hinge Roller Lever ZC-W255 53.4 34.6 t=1 *1 (21 × 21) 21.7 15 55 Two, 4.3±0.1 dia. mounting holes 14 A 25.4±0.15 Seal rubber (NBR) 12.7 dia. × 7.5 *2 OP 22.5 5 25.4±0.15 OP (21 × 21) 21.7 Two, 4.3±0.1 dia. mounting holes Angle of roller swing: 90° t=1 *1 14 53.4 34.6 12.7 dia. × 7.5 *2 A 73R t=1 *1 25.4±0.15 55 Seal rubber (NBR) 15 Two, 4.3±0.1 dia. mounting holes 12.7 dia. × 7.5 *2 Angle of roller swing: 90° OP 22.5 (10) 22 max.18.3 (21 × 21) 21.7 25.4±0.15 Seal rubber (NBR) FP 20 5 (10) 22 max.18.3 14 FP 20 5 Two, 4.3±0.1 dia. mounting holes A 54R 22.5 (21 × 21) 21.7 15 55 Terminal protective cover *1. Stainless steel lever *2. Stainless steel roller One-way Action Hinge Roller Lever Operating direction ZC-W3155 OP Terminal protective cover *1. Stainless steel lever *2. Stainless steel roller (10) 25.4±0.15 Seal rubber (NBR) FP 20 5 One-way Action Short Hinge Roller Lever ZC-W355 Operating direction 53.4 34.6 70R 22 max.18.3 15 55 Seal rubber (NBR) 12.7 dia. × 7.5 *2 A 22.5 (10) Terminal protective cover *1. Stainless steel lever *2. Stainless steel roller 14 FP 20 22 max.18.3 Two, 4.3±0.1 dia. mounting holes 53.4 34.6 t=1 *1 50R (21 × 21) 21.7 15 55 Terminal protective cover * Stainless steel lever Hinge Roller Lever ZC-W2155 FP 20 5 (10) Terminal protective cover * Stainless steel lever 8 FP 20 22 max.18.3 14 t=1 * 8 Terminal protective cover *1. Stainless steel lever *2. Stainless steel roller 55 15 Two, 4.3±0.1 dia. mounting holes (21 × 21) 21.7 Seal rubber (NBR) Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. Operating characteristics are for when the Switch is operated from direction A. Operating Characteristics Operating force OF Release force RF Pretravel PT Overtravel OT Movement Differential MD Free Position FP Operating Position OP Model max. min. max. min. max. max. ZC-D55 11.8 N 4.9 N 1.5 mm 2.4 mm 0.2 mm --32.4±0.8 mm ZC-Q55 11.8 N 4.9 N 1.5 mm 3 mm 0.2 mm --38.2±0.8 mm ZC-Q2255 11.8 N 4.9 N 1.5 mm 3 mm 0.2 mm --47.4±0.8 mm ZC-Q2155 11.8 N 4.9 N 1.5 mm 3 mm 0.2 mm --47.4±0.8 mm ZC-N2255 * 6.86 N 1.67 N 1.5 mm 2.5 mm 0.2 mm --47.4±0.8 mm ZC-N2155 * 6.86 N 1.67 N 1.5 mm 2.5 mm 0.2 mm --47.4±0.8 mm ZC-W155 2.75 N 0.59 N --8.4 mm 1.4 mm 36.7 mm 28.5±1.2 mm ZC-W255 3.92 N 0.78 N --6 mm 1 mm 49.2 mm 43±1.2 mm ZC-W2155 2.75 N 0.59 N --8.4 mm 1.4 mm 51.3 mm 43±1.2 mm ZC-W355 3.92 N 0.78 N --6 mm 1 mm 59.2 mm 53±1.2 mm ZC-W3155 2.75 N 0.59 N --8.4 mm 1.4 mm 61.2 mm 53±1.2 mm * Make sure that the permissible OT position is not exceeded. Operating Characteristics Operating force OF Release force RF Pretravel PT Overtravel OT Movement Differential MD Free Position FP Operating Position OP Model max. min. max. min. max. max. ZC-W55 3.92 N 0.78 N --6 mm 1 mm 34.7 mm 28.5±1.2 mm 4 ZC-@55 Molded Terminal Models (Not Approved by UL, CSA, or EN) Terminal Protective Cover, Seal Rubber, and Rubber Packing Use of the molded terminal model is recommended in locations subject to excessive dust, oil drips, or moisture. All types of ZC Switches can be fabricated into a molded terminal version. In this case, the molded terminal model will have the same dimensions and operating characteristics as the basic model from which the molded terminal model is fabricated. (The Switch is equipped with these 3 items as a standard.) • ZC Terminal Cover (Product code: ZC55-0002H) • ZC Seal Rubber (Product code: SC-1404C) • ZC Rubber Packing (Product code: ZC55-0003F) Suffix by Location of Lead Outlet Location of lead output Right-hand Left-hand Underside Model (Suffix) COM, NC, NO -MR -ML -MD Note: The suffixes on the left can be added to the model numbers given on page 1 to specify molded terminals. Lead Supplies SpeciLeads fication Nominal cross-sectional area (mm2) External diameter (mm) Terminal connections Length (m) V.C.T. (vinyl cabtire cable) 1.25 3 conductor: 10.5 dia. Black: COM White: NO Red: NC 1, 3 Note: When placing your order for the Switch, specify the required length of V.C.T. cable in addition to the model number of the Switch. Consult with your OMRON representative for other types of lead wires and for lead wires longer than 3 m. How to Order Example: Standard type: ZC-Q2255 Location of lead output:Right side Length of lead: 1 m (V.C.T. lead) When placing your order for the above Switch, specify the model number as ZC-Q2255-MR VCT 1M. 5 ZC-@55 Operation Indicator-equipped Models (Not Approved by UL, CSA, or EN) • All the models can be equipped upon request with a operation indicator to facilitate maintenance and inspection. • Because the indicator is incorporated in the Terminal Protective Cover, the dimensions of the Limit Switch are not affected. In this model, the lead wire is to be connected to the screw terminal. (A connecting washer is provided on the tip of the lead wire). The lead wire can be connected to either the NC or NO terminal. • Operating characteristics are the same as the standard model from which the operation indicator equipped model is fabricated. (For AC) • The operating voltage range is from 90 to 250 VAC. • The dimensions are the same as the standard type. The top of the Terminal Protective Cover is transparent to allow checking the operation easily. • When placing your order for the indicator equipped, AC-operated model, add suffix "L" to the end of the model number. Example: Standard type: ZC-Q2255 Indicator equipped type: ZC-Q2255-L (For DC) • The DC-operated is provided with an LED indicator. • There is no protective structure. • Since a rectifier stack is incorporated into the unit to permit reversing the polarity, this type can also operate on AC power source. • The LED projects from the housing for easy visibility. • When placing your order, add suffix "L2" or "L4" to the model number of the standard type. Example: Standard type: ZC-Q2255 Indicator equipped type: ZC-Q2255-L2 Contact Circuit Power supply Neon lamp R = 240 kΩ Model Voltage rating (V) L2 L4 12 24 Leakage current (mA) Approx.2.4 Approx.1.2 Internal resistance (kΩ) 4.3 18 Contact Circuit NC terminal Power supply Load LED Built-in switch Resistor NC terminal Power supply Built-in switch Load NO terminal Load Built-in switch Power supply Neon lamp Built-in switch R = 240 kΩ Note: If the wiring is as shown above, the operation of the respective parts will be as shown in the following table. The neon lamp is not wired when the Switch is delivered. Connect it as required. Contact NC NO Neon lamp ON OFF ON OFF Load Does not operate Operates Does not operate Operates Actuator Operates Does not operate Does not operate Operates NO terminal Load Resistor LED Note: If the wiring is as shown above, the operation of the respective parts will be as shown in the following table. The LED terminals are not wired when the Switch is delivered. Connect it as required. Contact NC NO LED ON OFF ON OFF Load Does not operate Operates Does not operate Operates Actuator Operates Does not operate Does not operate Operates 6 ZC-@55 Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment Micro Load Models Not Suitable Suitable Contact failure may occur is a General-purpose Switch is used to switch a microload circuit. Use Switches within the areas shown in the following chart. Even when using Microload Switches within the area shown below, contact wear will become more extreme with loads that generate surge current when switching and durability will be adversely affected. If necessary, insert a contact protective circuit. Microloads are indicated by N standard reference values. This value represents the failure rate at a 60% (λ60) reliability level. (JIS C5003) The equation λ60 = 0.5 × 10−6/operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability level of 60%. DC voltage (V) • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Dog Angle When operating the roller type, be sure to set the dog angle to less than 30° (even when operating at a low speed). Operating the model at a dog angle exceeding 30° will soon cause abrasion or damage. Do not apply a twisting force to the plunger. Set the OT to 70% to 100% of the specified value so that the actuator will not exceed the OT. Handling • When detaching the Terminal Protective Cover, insert a screwdriver and apply a force in the opening direction. Do not use excess force to remove the cover. Doing so may cause deformation in the fitting section and reduce the holding force. 0.8 W 26 mA 100 mA 30 24 Applicable area for Microload Models (ZC-@55-01) 12 Not applicable 5 1 mA 100 mA 160 mA 0 1 0.1 10 100 1,000 Current (mA) Model Minimum applicable load ZC-@55-01 ZC-@55 5 VDC 1mA 5 VDC 160mA Mounting • When mounting the Switch with screws on a side surface, fasten the Switch with M4 screws and use washers, spring washers, etc., to ensure secure mounting. • When mounting the Panel Mounttype Enclosed Switch (ZC-Q55, ZCQ2255, or ZC-Q2155) with screws on a side surface, remove the hexagonal nuts from the actuator. • When mounting the Terminal Protective Cover to the case, align the cover on the case and then press the cover down to mount it firmly. If the cover is pressed down in an inclined position, rubber packing will deform and thus affect the sealing capability. Applicable area for Generalpurpose Models (ZC-@55) Mounting Holes Two, 4.3-dia. or M4 screw holes 25.4±0.15 Mounting Holes 14.5+0.2 0 dia. Appropriate Tightening Torque A loose screw may result in a malfunction. Be sure to tighten each screw to the proper tightening torque as shown below. No. (1) (2) (3) Type Terminal screw Panel mounting screw Side mounting screw Appropriate Tightening Torque 0.78 to 1.18 N·m 4.90 to 7.84 N·m 1.18 to 1.47 N·m Operation Rubber packing Rubber packing • A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.) • Use weather-proof rubber (chloroprene rubber) as seal rubber for the ZC-N22(21)55. With the ZC-Q22(21)55, an appropriate OT line is marked on the plunger. Set the OT so that it is between the two X-surface lines. 7 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.