OMRON ZC

Enclosed Switch
ZC-@55
CSM_ZC-_55_DS_E_2_1
Small, High-precision Enclosed Switch
• Small, High-precision Enclosed Switches with Built-in Basic
Switches for High Repeatability and Durability of 10 Million
Operations Minimum.
• Same mounting pitch as Z Basic Switch.
• Requires less operating force than conventional limit switches.
• Lineup includes modes with operation indicators for easy
maintenance and inspection.
• Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for Information on approved
models.)
Be sure to read Safety Precautions on page 7 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
ZC-@55
(1)
(1) Actuator
D:
Q:
Q22:
Q21:
N22:
N21:
W:
W1:
W2:
W21:
W3:
W31:
Plunger
Panel mount plunger
Panel mount roller plunger
Panel mount crossroller plunger
Sealed roller plunger
Sealed crossroller plunger
Short hinge lever
Hinge lever
Short hinge roller lever
Hinge roller lever
One-way action short hinge roller lever
One-way action hinge roller lever
Ordering Information
Actuator
Model
Approved Standards
UL
CSA
EN
Plunger
ZC-D55
●
●
●
Panel mount
plunger
ZC-Q55
●
●
●
Panel mount
roller plunger
ZC-Q2255
●
●
●
Panel mount
crossroller plunger
ZC-Q2155
●
●
●
Sealed roller
plunger
ZC-N2255
●
●
●
Sealed crossroller
plunger
ZC-N2155
●
●
●
Short hinge
lever
ZC-W55
●
●
●
Hinge lever
ZC-W155
●
●
●
Short hinge
roller lever
ZC-W255
●
●
●
Hinge roller
lever
ZC-W2155
●
●
●
One-way action
short hinge roller
lever
ZC-W355
●
●
●
One-way action
hinge roller lever
ZC-W3155
●
●
●
Note: 1. Use molded terminal models when using the
Switch under one of the following conditions:
a) dusty, b) high amount of dripping oil, or c)
high humidity.
2. Models are available with lead outlets in three
positions: right-hand, left-hand, and underside.
1
ZC-@55
Specifications
Approved Standards
Agency
Standard
UL*
UL508
File No.
E76675
TÜV Rheinland
EN60947-1, EN60947-5-1
J50041904
CCC(CQC)
GB14048.5
2003010303077620
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Rated
voltage
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Inrush
current
Approved Standard Ratings
Non-inductive load (A)
Resistive load Lamp load
NC
NO
NC
NO
10
3
1.5
10
2.5
1.25
1.5
3
10
1.5
3
10
1.5
3
6
0.4
0.4
0.5
0.2
0.2
0.25
NC
NO
Inductive load (A)
Inductive load Motor load
NC
NO
NC
NO
10
5
2.5
10
3
1.5
2.5
5
6
2.5
5
6
2.5
5
5
0.05 0.05
0.05
0.03 0.03
0.03
UL/CSA
A300
120 VAC
240 VAC
Volt-amperes
(VA)
Make
Break
Current (A)
Carry
current
Voltage
Make
60
30
10A
Break
6
3
7,200
720
TÜVRheinland (EN60947-1, EN60947-5-1),
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
30 A max.
15 A max.
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions
according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Characteristics
Degree of protections
10,000,000 operations min.
Electrical
500,000 operations min.
10,000
7,000
5,000
0.05 mm/s to 0.5 m/s *1
3,000
Mechanical
120 operations/min
Electrical
20 operations/min
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value for the builtin switch when tested alone)
Dielectric
strength
Between non-continuous terminals
1,000 VAC, 50/60 Hz for 1 min
Between each terminal
and non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui)
1,000 VAC
Pollution degree
(operating environment)
3 (IEC947-5-1)
Short-circuit protective device
10 A-fuse type gG (IEC 60269)
Protection against electric shock
Class II
Proof tracking index (PTI)
175
Switch category
D (IEC335)
Rated operating current (Ie)
10 A
Rated operating voltage (Ue)
250 VAC
Vibration
Malfunction
resistance
10 to 55 Hz, 1.5-mm double amplitude *2
Destruction
Shock
resistance Malfunction
Durability (×104 operations)
Mechanical
Operating speed
Operating
frequency
Electrical Durability
125 VAC cosφ=1
125 VAC cosφ=0.4
250 VAC cosφ=1
1,000
700
500
250 VAC cosφ=0.4
300
100
70
50
Operating temperature: +20±2°C
Operating humidity: 65±5%RH
Operating frequency: 20 operations/min
30
10
0
2
4
6
8
10
12
Switching current (A)
1,000 m/s2 max.
300 m/s2 max.
(in case of plunger model) *1 *2
Ambient operating temperature
−10°C to +80°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight
Approx. 92 g (in case of ZCQ22(21)55)
*1. Only for models with plungers. (Contact your OMRON representative for
information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
Mechanical Durability (for ZC-Q55)
10,000
7,000
5,000
3,000
Durability (×104 operations)
Durability
Engineering Data
IP67
1,000
700
500
300
100
70
50
Operating temperature: +20±2˚C
Operating humidity: 65±5%RH
No load
Operating frequency: 120 operations/min
30
0
0.1
0.3
0.5 0.7 1
3
5 7 10
OT (mm)
2
ZC-@55
Structure and Nomenclature
Structure
Contact Form
Changing the Terminal Protective Cover around allows the cable to
be pulled out from either the right or the left.
(COM)1
2(NC)
Roller
4(NO)
Plunger
Case
NC fixed contact
Moving contact
Switch
NO fixed contact
Seal rubber
Packing
Terminal Protective
Cover
Common Normally
Normally
terminal open
closed terminal (NC)
(COM)
terminal (NO)
Note: M4 binding head screws (with toothed washers) are used as the terminal screws.
Dimensions and Operating Characteristics
Plunger
ZC-D55
(Unit: mm)
Panel Mount Plunger
ZC-Q55
53.4
A
PT
14 dia.
7.8 dia.*1
53.4
23.3
A
PT
Two M14 × 1
hexagon nuts *3
14
23.3
7.8 dia. *
12.5 *2
8
14
OP
OP
21
21
19
5
(10)
22 max.18.3
25.4±0.15
(10)
22 max.18.3
25.4±0.15
(21 ×
15
55
Terminal Protective Cover
19
5
Two, 4.3±0.1 dia.
mounting holes
21.7
(21 × 21)
15
55
Terminal protective cover
Two, 4.3±0.1 dia.
mounting holes
(NBR)
21.7
Seal rubber
(NBR)
*1. Stainless steel plunger
*2. The length of the imperfect threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
*Stainless steel plunger
Note: Do not use the M14 mounting
screw and the case mounting
hole at the same time.
Panel Mount Roller Plunger
53.4
ZC-Q2255
A
PT
23.3
12.5
(3.6)
Two M14 × 1
hexagon nuts *3
14
OP
21
19
5
12.5
(2.25)
*2
21
19
5
(10)
22 max.18.3
11 dia. × 4.7 *1
14
Two M14 × 1
hexagon nuts *3
(2.25)
*2
23.3
Set position indication line
(3.6)
OP
Panel Mount Crossroller Plunger
position
53.4
ZC-Q2155 PT Set
indication line
A
11 dia. × 4.7 *1
(10)
22 max.18.3
25.4±0.15
(21 × 21)
15
55
Terminal protective cover
Two, 4.3±0.1 dia.
mounting holes
21.7
25.4±0.15
Seal rubber
(NBR)
*1. Stainless sintered alloy roller
*2. The length of the imperfect threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
23.3
A
PT
14
OP
23.3
14
Rubber boot
(chloroprene rubber)
22 max.18.3
55
9.5 dia. × 4.7 *
19
19
5
(10)
25.4±0.15
Seal rubber
(NBR)
OP
5
Terminal protective cover
* Stainless sintered alloy roller
(21 × 21)
21.7
not use the M14 mounting
screw and the case mounting
hole at the same time.
Sealed Crossroller Plunger
ZC-N2155
53.4
9.5 dia. × 4.7 *
Rubber boot
(chloroprene rubber)
53.4
A
PT
Two, 4.3±0.1 dia.
mounting holes
*1. Stainless sintered alloy roller
*2. The length of the imperfect threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
Note: Do
Note: Do not use the M14 mounting
screw and the case mounting
hole at the same time.
Sealed Roller Plunger
ZC-N2255
15
55
Terminal protective cover
15
Two, 4.3±0.1 dia.
mounting holes
(10)
22 max.18.3
25.4±0.15
(21 × 21)
21.7
Seal rubber
(NBR)
Terminal protective cover
* Stainless sintered alloy roller
55
15
Two, 4.3±0.1 dia.
mounting holes
(21 × 21)
21.7
Seal rubber
(NBR)
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
3
ZC-@55
Short Hinge Roller Lever
ZC-W55
53.4
34.6
Hinge Lever
ZC-W155
53.4
34.6
14
t=1 *
A
50R
OP
22.5
5
70R
A
OP
22.5
(10)
22 max.18.3
25.4±0.15
Short Hinge Roller Lever
ZC-W255
53.4
34.6
t=1 *1
(21 × 21)
21.7
15
55
Two, 4.3±0.1 dia.
mounting holes
14
A
25.4±0.15
Seal rubber
(NBR)
12.7 dia. × 7.5 *2
OP
22.5
5
25.4±0.15
OP
(21 × 21)
21.7
Two, 4.3±0.1 dia.
mounting holes
Angle of roller
swing: 90°
t=1 *1
14
53.4
34.6
12.7 dia. × 7.5 *2
A
73R
t=1 *1
25.4±0.15
55
Seal rubber
(NBR)
15
Two, 4.3±0.1 dia.
mounting holes
12.7 dia. × 7.5 *2
Angle of roller
swing: 90°
OP
22.5
(10)
22 max.18.3
(21 × 21)
21.7
25.4±0.15
Seal rubber
(NBR)
FP
20
5
(10)
22 max.18.3
14
FP
20
5
Two, 4.3±0.1 dia.
mounting holes
A
54R
22.5
(21 × 21)
21.7
15
55
Terminal protective cover
*1. Stainless steel lever
*2. Stainless steel roller
One-way Action Hinge Roller Lever
Operating direction
ZC-W3155
OP
Terminal protective cover
*1. Stainless steel lever
*2. Stainless steel roller
(10)
25.4±0.15
Seal rubber
(NBR)
FP
20
5
One-way Action Short Hinge Roller Lever
ZC-W355
Operating direction
53.4
34.6
70R
22 max.18.3
15
55
Seal rubber
(NBR)
12.7 dia. × 7.5 *2
A
22.5
(10)
Terminal protective cover
*1. Stainless steel lever
*2. Stainless steel roller
14
FP
20
22 max.18.3
Two, 4.3±0.1 dia.
mounting holes
53.4
34.6
t=1 *1
50R
(21 × 21)
21.7
15
55
Terminal protective cover
* Stainless steel lever
Hinge Roller Lever
ZC-W2155
FP
20
5
(10)
Terminal protective cover
* Stainless steel lever
8
FP
20
22 max.18.3
14
t=1 *
8
Terminal protective cover
*1. Stainless steel lever
*2. Stainless steel roller
55
15
Two, 4.3±0.1 dia.
mounting holes
(21 × 21)
21.7
Seal rubber
(NBR)
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
Operating Characteristics
Operating force
OF
Release force
RF
Pretravel
PT
Overtravel
OT
Movement Differential MD
Free Position
FP
Operating Position
OP
Model
max.
min.
max.
min.
max.
max.
ZC-D55
11.8 N
4.9 N
1.5 mm
2.4 mm
0.2 mm
--32.4±0.8 mm
ZC-Q55
11.8 N
4.9 N
1.5 mm
3 mm
0.2 mm
--38.2±0.8 mm
ZC-Q2255
11.8 N
4.9 N
1.5 mm
3 mm
0.2 mm
--47.4±0.8 mm
ZC-Q2155
11.8 N
4.9 N
1.5 mm
3 mm
0.2 mm
--47.4±0.8 mm
ZC-N2255 *
6.86 N
1.67 N
1.5 mm
2.5 mm
0.2 mm
--47.4±0.8 mm
ZC-N2155 *
6.86 N
1.67 N
1.5 mm
2.5 mm
0.2 mm
--47.4±0.8 mm
ZC-W155
2.75 N
0.59 N
--8.4 mm
1.4 mm
36.7 mm
28.5±1.2 mm
ZC-W255
3.92 N
0.78 N
--6 mm
1 mm
49.2 mm
43±1.2 mm
ZC-W2155
2.75 N
0.59 N
--8.4 mm
1.4 mm
51.3 mm
43±1.2 mm
ZC-W355
3.92 N
0.78 N
--6 mm
1 mm
59.2 mm
53±1.2 mm
ZC-W3155
2.75 N
0.59 N
--8.4 mm
1.4 mm
61.2 mm
53±1.2 mm
* Make sure that the permissible OT position is not exceeded.
Operating Characteristics
Operating force
OF
Release force
RF
Pretravel
PT
Overtravel
OT
Movement Differential MD
Free Position
FP
Operating Position
OP
Model
max.
min.
max.
min.
max.
max.
ZC-W55
3.92 N
0.78 N
--6 mm
1 mm
34.7 mm
28.5±1.2 mm
4
ZC-@55
Molded Terminal Models
(Not Approved by UL, CSA, or EN)
Terminal Protective Cover, Seal Rubber, and
Rubber Packing
Use of the molded terminal model is recommended in locations
subject to excessive dust, oil drips, or moisture.
All types of ZC Switches can be fabricated into a molded terminal
version. In this case, the molded terminal model will have the same
dimensions and operating characteristics as the basic model from
which the molded terminal model is fabricated.
(The Switch is equipped with these 3 items as a
standard.)
• ZC Terminal Cover
(Product code: ZC55-0002H)
• ZC Seal Rubber
(Product code: SC-1404C)
• ZC Rubber Packing
(Product code: ZC55-0003F)
Suffix by Location of Lead Outlet
Location of
lead output
Right-hand
Left-hand
Underside
Model (Suffix)
COM, NC, NO
-MR
-ML
-MD
Note: The suffixes on the
left can be added to
the model numbers
given on page 1 to
specify molded
terminals.
Lead Supplies
SpeciLeads fication
Nominal
cross-sectional
area
(mm2)
External
diameter
(mm)
Terminal
connections
Length
(m)
V.C.T.
(vinyl
cabtire
cable)
1.25
3 conductor:
10.5 dia.
Black:
COM
White: NO
Red: NC
1, 3
Note: When placing your order for the Switch, specify the required length of
V.C.T. cable in addition to the model number of the Switch.
Consult with your OMRON representative for other types of lead wires
and for lead wires longer than 3 m.
How to Order
Example:
Standard type:
ZC-Q2255
Location of lead output:Right side
Length of lead:
1 m (V.C.T. lead)
When placing your order for the above Switch, specify the model
number as ZC-Q2255-MR VCT 1M.
5
ZC-@55
Operation Indicator-equipped Models (Not Approved by UL, CSA, or EN)
• All the models can be equipped upon request with a operation indicator to facilitate maintenance and inspection.
• Because the indicator is incorporated in the Terminal Protective Cover, the dimensions of the Limit Switch are not affected. In this model, the
lead wire is to be connected to the screw terminal. (A connecting washer is provided on the tip of the lead wire).
The lead wire can be connected to either the NC or NO terminal.
• Operating characteristics are the same as the standard model from which the operation indicator equipped model is fabricated.
(For AC)
• The operating voltage range is from 90 to 250 VAC.
• The dimensions are the same as the standard type. The top of the
Terminal Protective Cover is transparent to allow checking the
operation easily.
• When placing your order for the indicator equipped, AC-operated
model, add suffix "L" to the end of the model number.
Example:
Standard type:
ZC-Q2255
Indicator equipped type: ZC-Q2255-L
(For DC)
• The DC-operated is provided with an LED indicator.
• There is no protective structure.
• Since a rectifier stack is incorporated into the unit to permit reversing
the polarity, this type can also operate on AC power source.
• The LED projects from the housing for easy visibility.
• When placing your order, add suffix "L2" or "L4" to the model number of the standard type.
Example:
Standard type:
ZC-Q2255
Indicator equipped type: ZC-Q2255-L2
Contact Circuit
Power supply
Neon lamp
R = 240 kΩ
Model
Voltage rating (V)
L2
L4
12
24
Leakage current
(mA)
Approx.2.4
Approx.1.2
Internal
resistance (kΩ)
4.3
18
Contact Circuit
NC terminal
Power supply
Load
LED
Built-in switch
Resistor
NC terminal
Power supply
Built-in switch
Load
NO terminal
Load
Built-in switch
Power supply
Neon lamp
Built-in switch
R = 240 kΩ
Note: If the wiring is as shown above, the operation of the respective parts will
be as shown in the following table. The neon lamp is not wired when the
Switch is delivered. Connect it as required.
Contact
NC
NO
Neon lamp
ON
OFF
ON
OFF
Load
Does not operate
Operates
Does not operate
Operates
Actuator
Operates
Does not operate
Does not operate
Operates
NO terminal
Load
Resistor
LED
Note: If the wiring is as shown above, the operation of the respective parts will
be as shown in the following table. The LED terminals are not wired when
the Switch is delivered. Connect it as required.
Contact
NC
NO
LED
ON
OFF
ON
OFF
Load
Does not operate
Operates
Does not operate
Operates
Actuator
Operates
Does not operate
Does not operate
Operates
6
ZC-@55
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Precautions for Correct Use
Operating Environment
Micro Load Models
Not Suitable
Suitable
Contact failure may occur is a General-purpose Switch is used to
switch a microload circuit. Use Switches within the areas shown in the
following chart. Even when using Microload Switches within the area
shown below, contact wear will become more extreme with loads that
generate surge current when switching and durability will be
adversely affected. If necessary, insert a contact protective circuit.
Microloads are indicated by N standard reference values. This value
represents the failure rate at a 60% (λ60) reliability level. (JIS C5003)
The equation λ60 = 0.5 × 10−6/operations indicates that a failure rate
of 1/2,000,000 operations can be expected at a reliability level of 60%.
DC voltage (V)
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Dog Angle
When operating the roller type, be sure to set the dog angle to less than
30° (even when operating at a low speed). Operating the model at a dog
angle exceeding 30° will soon cause abrasion or damage. Do not apply a
twisting force to the plunger. Set the OT to 70% to 100% of the specified
value so that the actuator will not exceed the OT.
Handling
• When detaching the Terminal
Protective Cover, insert a
screwdriver and apply a force
in the opening direction. Do
not use excess force to
remove the cover. Doing so
may cause deformation in the
fitting section and reduce the
holding force.
0.8 W
26 mA 100 mA
30
24
Applicable area
for Microload
Models
(ZC-@55-01)
12
Not
applicable
5
1 mA
100 mA 160 mA
0
1
0.1
10
100
1,000
Current (mA)
Model
Minimum applicable
load
ZC-@55-01
ZC-@55
5 VDC 1mA
5 VDC 160mA
Mounting
• When mounting the Switch with
screws on a side surface, fasten the
Switch with M4 screws and use
washers, spring washers, etc., to
ensure secure mounting.
• When mounting the Panel Mounttype Enclosed Switch (ZC-Q55, ZCQ2255, or ZC-Q2155) with screws
on a side surface, remove the
hexagonal nuts from the actuator.
• When mounting the Terminal
Protective Cover to the case,
align the cover on the case and then press the cover down to mount
it firmly. If the cover is pressed down in an inclined position, rubber
packing will deform and thus affect the sealing capability.
Applicable
area for
Generalpurpose
Models
(ZC-@55)
Mounting Holes
Two, 4.3-dia. or M4 screw holes
25.4±0.15
Mounting Holes
14.5+0.2
0 dia.
Appropriate Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No.
(1)
(2)
(3)
Type
Terminal screw
Panel mounting screw
Side mounting screw
Appropriate Tightening
Torque
0.78 to 1.18 N·m
4.90 to 7.84 N·m
1.18 to 1.47 N·m
Operation
Rubber packing
Rubber packing
• A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.)
• Use weather-proof rubber (chloroprene rubber) as seal rubber for
the ZC-N22(21)55.
With the ZC-Q22(21)55, an
appropriate OT line is marked on
the plunger. Set the OT so that it is
between the two X-surface lines.
7
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.