OMRON ZE-N-2S

Enclosed Switches
ZE/ZV/ZV2/XE/XV/XV2
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
General-purpose Enclosed
Switches with High Breaking
Capacity and High Durability
• Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
• X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
• Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
• Terminals face the front when the cover is removed for
easy connection.
• Switches with ground terminals have CE marking.
• Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read Safety Precautions on page 8 to 9 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(4) Conduit/Ground Terminal *
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
Approved
standards
Model
AC
ZE-Q-2
Model
UL
CSA
●
●
ZV-Q-2
●
●
ZV-Q22-2
Approved
standards
Model
UL
CSA
●
●
ZV2-Q-2
●
●
ZV2-Q22-2
Approved
standards
UL
CSA
●
●
●
●
●
●
●
●
●
●
●
●
Plunger
DC
XE-Q-2
AC
ZE-Q22-2
XV-Q-2
XV2-Q-2
DC
XE-Q22-2
AC
ZE-Q21-2
DC
XE-Q21-2
AC
ZE-QA2-2
DC
XE-QA2-2
AC
ZE-QA277-2
DC
XE-QA277-2
AC
ZE-N-2
DC
XE-N-2
Sealed roller plunger
AC
ZE-N22-2
●
●
ZV-N22-2
●
●
ZV2-N22-2
●
●
Sealed crossroller
plunger
AC
ZE-N21-2
●
●
ZV-N21-2
●
●
ZV2-N21-2
●
●
AC
ZE-NA2-2
●
●
ZV-NA2-2
●
●
ZV2-NA2-2
●
●
DC
XE-NA2-2
AC
ZE-NA277-2
●
●
DC
XE-NA277-2
Roller plunger
General
purpose
XV-Q22-2
●
●
ZV-Q21-2
XV2-Q22-2
●
●
ZV2-Q21-2
Crossroller plunger
XV-Q21-2
●
●
ZV-QA2-2
--●
●
ZV2-QA2-2
Roller arm lever
One-way action roller
arm lever
XV-QA2-2
●
●
XV2-QA2-2
---
ZV2-QA277-2
--●
●
ZV-N-2
--●
●
ZV2-N-2
Sealed plunger
Sealed
(Booted)
XV-N-2
XV2-N-2
Sealed roller arm lever
One-way action
sealed roller arm lever
XV-NA2-2
●
●
ZV-NA277-2
XV2-NA2-2
●
●
---
ZV2-NA277-2
XV2-NA277-2
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
Standard
UL
CSA
File No.
UL508
E76675
CSA C22.2 No.14
LR45746
GB14048.5
2003010303077623
CCC (CQC)
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
Resistive load
NC
ZE-@
ZV-@
ZV2-@
XE-@
XV-@
XV2-@
NO
125 VAC
250 VAC
480 VAC
15
15
10
125 VDC
250 VDC
0.5
0.25
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
Inductive load (A)
Lamp load
NC
NO
3
2.5
1.5
1.5
1.25
0.75
0.5
0.25
3
3
3
3
1.5
Inductive load
NC
NO
15
15
6
Motor load
NC
NO
5
3
1.5
2.5
1.5
0.75
0.05
0.03
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
Inrush
current
NC
30 A max.
NO
15 A max.
0.05
0.03
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
Characteristics
UL/CSA
Degree of protection
Model
Rated voltage
Current
Horsepower
ZE
125 VAC
250 VAC
480 VAC
15 A
15 A
15 A
1/8HP
1/4HP
125 VDC
250 VDC
0.5 A
0.25 A
Mechanical
Durability
*2
Electrical
--Operating speed
CCC (GB14048.5)
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between currentcarrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-carrying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Applicable category and ratings
AC-12 10 A/250 VAC
Ambient operating temperature
Ambient operating humidity
Weight
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s2 min.
100 m/s2 min.*4
50 m/s2 min.*5
−10°C to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
Note: The above figures are initial values.
*1. IP65 for @-N models and IP60 for @-Q models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
XE (L/R = 0)
Durability (x 104 operations)
Durability (x 104 operations)
ZE (cosφ = 1)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
125 VAC
500
250 VAC
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
250 VAC
50
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
1
2
3
5
10
Switching current (A)
XE (L/R = 7 ms)
Durability (x 104 operations)
Durability (x 104 operations)
ZE (cosφ = 0.4)
0
Operating frequency:
20 operations/min
OT: Full stroke
1,000
125 VAC
500
250 VAC
480 VAC
Operating frequency:
20 operations/min
OT: Full stroke
100
70
125 VAC
50
30
250 VAC
20
100
50
0
2
4
6
8
10
12
14
16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
Contact Form
ZE-NA2-2
COM
NC
NO
Pin plunger
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Tightening band
Rubber cap (CR)
Case
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
(Unit: mm)
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
12R *
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
OP
19
OP
25.5
23
2.1±0.1
25.4±0.3
86
2.1±0.1
25.4±0.3
24
25.4±0.12
86
* Stainless steel plunger
25.4±0.12
24
* Stainless steel roller
12.7 dia. × 4.8 *
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
PT
19
25.5
23
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
12.7 dia. × 4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19.1 dia. × 7.9 *1
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
Two, M4
(length: 45)
OP
*2
39.7
44±0.8
19.3
19
19
2.1±0.1
25.4±0.3
86
25.4±0.12
25.5
23
25.5
23
2.1±0.1
25.4±0.3
24
86
25.4±0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
* Stainless steel roller
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Model
Operating force
Release force
Pretravel
Over Travel
Movement Differential
OF
RF min.
PT max.
OT min.
MD max.
Operating Position
OP
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
---
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia. × 9 *1
XE-QA277-2
Operate in this
direction only
39.7
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
Sealed Plunger
ZE-N-2
XE-N-2
*2
12R *
PT
2.1±0.1
86
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
Two, M4
(length: 45)
2.1±0.1
25.4±0.3
24
25.4±0.12
25.5
23
25.5
25.4±0.3
OP
19
19
23
Sealed Roller Plunger
ZE-N22-2
17
Two, M4
(length: 45)
44±0.8
19.3
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
25.4±0.12
24
* Stainless steel plunger
Sealed Crossroller Plunger
ZE-N21-2
12.7 dia. × 4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
12.7 dia. × 4.8 *
PT
OP
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
OP
19
19
25.5
23
2.1±0.1
25.4±0.3
86
86
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
2.1±0.1
25.4±0.3
24
25.4±0.12
25.5
23
24
* Stainless steel roller
19.1 dia. × 7.9 *1
39.7
One-way Action Sealed Roller Arm Lever
18.7 dia. × 9 *1
ZE-NA277-2
XE-NA277-2
*2
(40)
17.4R
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
25.4±0.12
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
53.4±0.8
19.3
Two, M4
(length: 45)
86
25.4±0.12
53.4±0.8
19.3
19
2.1±0.1
25.4±0.3
24
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
19
25.5
23
2.1±0.1
25.4±0.3
PT
17
25.5
23
Operate in this
direction only
39.7
*2
25.4±0.12
24
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
OF max.
RF min.
PT max.
OT min.
MD max.
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
OP
OF max.
RF min.
PT max.
OT min.
MD max.
OP
---
45.8±0.8 mm
49.7±0.8 mm
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
49.7±0.8 mm
---
---
5
ZE/ZV/ZV2/XE/XV/XV2
Base Mounting/Diagonal Side Mounting Models
The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom.
The flange on base-mounted models is shown with dotted lines.
Plunger
ZV(2)-Q-2
XV(2)-Q-2
Roller Plunger
ZV(2)-Q22-2
XV(2)-Q22-2
t = 3 (ZV-Q-2/XV-Q-2 flange)
53R
t = 3 (ZV-Q22-2/XV-Q22-2 flange)
53R
41.3±0.2
54
41.3±0.2
10.5±0.3
Two, 4.3±0.2 dia.
12R *1
JIS B0202 G1/2
Effective
thread: 4
threads min.
10.5±0.3
Two, 4.3±0.2 dia.
36.6
17
36.6
12.7 dia. × 4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
PT
26.1
PT
26.1
(see note 2)
17
(see note 1)
5
54
5
OP
31±0.2
OP
31±0.2
23
23
3
3
*2
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless steel plunger
*2. Only the ZV2-Q-2 and XV2-Q-2 incorporate
mounting holes.
25.4±0.3
*2
Two, 5.4 +0.2
0 dia.
holes
75±0.2
5.5
86
*1. Stainless steel roller
*2. Only the ZV2-Q22-2 and XV2-Q22-2
incorporate mounting holes.
Crossroller Plunger
ZV(2)-Q21-2
XV(2)-Q21-2
Roller Arm Lever
ZV(2)-QA2-2
XV(2)-QA2-2
t = 3 (ZV-QA2-2/XV-QA2-2 flange)
t = 3 (ZV-Q21-2/XV-Q21-2 flange)
53R
53R
41.3±0.2
54
41.3±0.2 54
10.5±0.3
Two, 4.3±0.2 dia.
Two, 4.3±0.2 dia.
36.6
12.7 dia. × 4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
19.1 dia. × 7.9 *1
JIS B0202
G1/2
Effective
23.1 max.
thread: 4
threads min.
PT
17
19.3
PT
26.1
(see note 3)
17
5
10.5±0.3
36.6
39.7
*2
30±0.8
5
OP
31±0.2
31±0.2
23
69.5±0.8
23
3
3
*2
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
75±0.2
86
5.5
25.4±0.3
*1. Stainless steel roller
*2. Only the ZV2-Q21-2 and XV2-Q21-2 incorporate
mounting holes.
*3
Two, 5.4 +0.2
0 dia.
holes
75±0.2
5.5
86
*1. Stainless sintered roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-QA2-2 and XV2-QA2-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
ZV-Q-2
ZV2-Q-2
OF
RF min.
PT max.
OT min.
MD max.
OP
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XV-Q-2
XV2-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
63.7±0.8 mm (see note 1)
(ZV-Q-2, XV-Q-2)
ZV-Q22-2
ZV2-Q22-2
XV-Q22-2
XV2-Q22-2
ZV-Q21-2
ZV2-Q21-2
XV-Q21-2
XV2-Q21-2
ZV-QA2-2
ZV2-QA2-2
XV-QA2-2
XV2-QA2-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
75.2±0.8 mm (see note 2)
(ZV-Q22-2, XV-Q21-2)
75.2±0.8 mm (see note 3)
(ZV-Q22-2, XV-Q21-2)
---
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 ±0.8 mm.
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 ±1 mm.
3. OP for ZV2-Q21-2 and XV2-Q21-2 is 35.7 ±0.8 mm.
6
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZV2-QA277-2
XV(2)-QA277-2
Sealed Plunger
ZV(2)-N-2
XV(2)-N-2
t=3 (ZV-NA277-2/XV-NA277-2 flanges)
t = 3 (ZV-N-2/XV-N-2 flange)
53R
18.7 dia. × 9 *1
41.3±0.2
54
Two, 4.3±0.2 dia. holes
10.6±0.3
10.6±0.3
PT
17
41.3±0.2
54
36.6
Two, 4.3±0.2 dia. holes
Operates in this
direction only
*2
39.7
(40)
R17.4
JIS B0202 G1/2
Effective
thread: 4
threads min.
53R
19.3
5
PT
26.1
12CR *1 JIS B0202 G1/2
Effective
thread: 4 threads min.
30±0.8
36.6
(see note 1)
17
69.5±0.8
5
31±0.2
OP
31±0.2
23
3
*3
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
23
75±0.2
3
5.5
86
*2
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA277-2 and XV2-NA277-2
incorporate mounting holes.
Sealed Roller Plunger
ZV(2)-N22-2
Sealed Crossroller Plunger
ZV(2)-N21-2
t = 3 (ZV-N21-2 flange)
53R
41.3±0.2
54
Two, 4.3±0.2 dia. holes
10.6±0.3
36.6
12.7 dia. × 4.8 *1
JIS B0202
G1/2 Effective
thread: 4 threads min.
12.7 dia. × 4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
17
PT
(see note 2)
17
41.3±0.2
54
Two, 4.3±0.2 dia. holes
26.1
5
5.5
86
*1. Stainless steel plunger
*2. Only the ZV2-N-2 and XV2-N-2 incorporate mounting holes.
t = 3 (ZV-N22-2 flange)
53R
75±0.2
10.6±0.3
36.6
PT
26.1
(see note 3)
5
OP
31±0.2
OP
31±0.2
23
23
3
3
*2
25.4±0.3 Two, 5.4 +0.2 dia.
0
holes
75±0.2
86
*2
25.4±0.3 Two, 5.4 +0.2
0 dia.
holes
5.5
*1. Stainless steel roller
*2. Only the ZV2-N22-2 incorporate mounting holes.
75±0.2
86
5.5
*1. Stainless steel roller
*2. Only the ZV2-N21-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
XV-QA277-2
XV2-QA277-2
ZV2-QA277-2
OF max.
RF min.
PT max.
OT min.
MD max.
OP
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
---
ZV-N-2
ZV2-N-2
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
XV-N-2
XV2-N-2
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
71.4±0.8 mm (see note 1)
(ZV-N-2, XV-N-2)
ZV-N22-2
ZV2-N22-2
ZV-N21-2
ZV2-N21-2
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
75.2±0.8 mm
(see note 2)
(ZV-N22-2)
75.2±0.8 mm
(see note 3)
(ZV-N21-2)
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm.
2. OP for ZV2-N22-2 is 35.7 ±0.8 mm.
3. OP for ZV2-N21-2 is 35.7 ±0.8 mm.
7
ZE/ZV/ZV2/XE/XV/XV2
Sealed Roller Arm Lever
ZV(2)-NA2-2
XV(2)-NA2-2
One-way Action Sealed Roller Arm Lever
ZV(2)-NA277-2
XV(2)-NA277-2
t=3 (ZV-NA277-2/XV-NA277-2 flanges)
t=3 (ZV-NA2-2/XV-NA2-2 flanges)
53R
53R
19.1 dia. × 9 *1
Two, 4.3±0.2 dia.
18.7 dia. × 9 *1
10.6±0.3
(40)
17.4R
*2
JIS B0202
G1/2
Effective
thread: 4
threads min.
PT
39.7
Operates in this
direction only
*2
PT
17
39.5±0.8
19.3
19.3
39.5±0.8
5
5
79±0.8
79±0.8
31±0.2
31±0.2
23
54
10.6±0.3
36.6
(23.1)
17
Two, 4.3±0.2 dia. holes
36.6
39.7
JIS B0202
G1/2
Effective
thread: 4
threads min.
41.3±0.2
41.3±0.2 54
23
3
3
*3
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA277-2 and XV2-NA277-2 incorporate
mounting holes.
*3
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless sintered alloy roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
OF max.
RF min.
PT max.
OT min.
MD max.
ZV-NA2-2
ZV2-NA2-2
XV-NA2-2
XV2-NA2-2
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
ZV-NA277-2
ZV2-NA277-2
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
XV-NA277-2
XV2-NA277-2
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Precautions for Correct Use
Operating Environment
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Be sure to protect part A with grease in order to maintain the
mechanical durability and performance of the Limit Switch. The use
of molybdenum disulfide grease is recommended.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
8
ZE/ZV/ZV2/XE/XV/XV2
Mounting
Mounting
• With the Roller Lever-type Enclosed Switches, the roller arm has
been temporarily tightened prior to shipment, so that its position
may be adjusted later. When mounting the Switch, be sure to retighten the roller arm so as to prevent it from becoming loose during
operation.
• To adequately maintain the seals at the mounting screw section on
the side of the Enclosed Switch, insert each O-ring correctly and
secure it with the lock nut.
• To provide the Switch with improved sealing property, use of the SC
Connector is recommended. Refer to Limit Switch Connectors for
details on SC Connectors.
• When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch.
Mounting Holes
Side Mounting
Bottom Mounting
Two, 4.3 dia.
mounting holes or
M4 screw holes
Two, 4.3 dia.
mounting holes or
M4 screw holes
25.4±0.1
41.3±0.15
Side Diagonal Mounting
Two, 5.4 dia.
mounting holes or
M5 screw holes
31±0.1
Appropriate Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No.
Type
Appropriate tightening torque
1
Cover mounting screw
1.18 to 1.37 N·m
2
Switch mounting screw*1
1.18 to 1.37 N·m
3
Switch mounting screw*2
4.90 to 5.88 N·m
4
Switch terminal screw
(M4 screws)
0.78 to 1.18 N·m
5
Roller arm mounting nut
4.90 to 5.88 N·m
*1. This torque range applies to side mounting or bottom mounting. (M4 screws)
*2. This torque range applies to diagonal side mounting. (M5 Allen-head bolt)
75±0.1
Operation
• Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
precision of the Limit Switch. Make sure that the shape of the cam
is smooth enough.
• Check that OT has a sufficient margin. The actual OT should be
rated OT x 0.7 to 1.
Dedicated Wrench
1. The roller arm can be set freely within a range of 225° after
loosening the nut.
2. The roller arm mounting bracket can be set in any direction after
loosening the nut.
▲
• Make sure that the nut is free of foreign substances when the nut is
loosened.
• A dedicated wrench is provided separately.
Model
SUPANA FOR ZE
9
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
ZV-N-2S ZE-NJ-2S ZE-QCL-2S ZE-N22-2S ZE-N-2S ZE-Q22-2S ZE-NA2-2S XE-NA277-2 ZE-N-2 ZE-N21-2S
ZE-N22-2 ZE-N-2G ZE-NA2-2 ZE-NA2-2G ZE-NA2-2S-NL ZE-NA277-2G ZE-NA277-2S ZE-NCL-2S ZE-Q-2 ZEQ21-2 ZE-Q21-2G ZE-Q21-2S ZE-Q22-2 ZE-Q22-2G ZE-Q-2G ZE-Q-2S ZE-QA2-2 ZE-QA2-2S ZE-QA277-2
ZE-QA277-2S ZE-YN-2 ZE-YQ-22-2 ZV2-N-2 ZV2-N21-2 ZV2-N21-2S ZV2-N22-2 ZV2-N22-2S ZV2-N-2S ZV2NA2-2S ZV2-NA277-2S ZV2-NJ-2S ZV2-Q-2S ZV2-QA2-2S ZV-N22-2S ZV-NA2-2 ZV-NA2-2S ZV-NA277-2S ZVNCL-2S ZV-NJ-2S ZV-Q21-2S ZV-Q22-2S ZV-QA2-2S ZV-N21-2