DIODES ZMT32

ZMT32
Magnetic Field Angle Sensor
Description
The ZMT32 is a thin film permalloy magnetic
field sensor, which contains two galvanic
isolated Wheatstone Bridges for high
precision angle measurement applications
under low field conditions. This angle sensor
is based on the anisotropic magnetoresistive
effect (AMR). The two internal (VCC1, VCC2)
bridges enclose a relative sensitive angle of
45 degrees. The input field is a rotating
magnetic field in the chip plane (parallel to
the surface of package). This rotating field will
make available two independent sinusoidal
output signals with the following relationship
The precise ZMT32 works with low field
applications (Hrot= 8 to 25kA/m), much lower
than similar devices. The ultimate output signal
quality depends on the external magnetic
material and on the mechanical realization.
The ZMT32 is a passive part and the ArcTangent interpolation needs external signal
processing. Typical areas of application are
angle and speed measurement.
VO 2 Sin(2α )
=
= Tan(2α )
VO1 Cos (2α )
where α = angle between sensor axis and field
direction
Features
Applications
•
contactless angle measurement up to 180°
•
angle and angular velocity measuring systems
•
flexible measuring solutions for moved
systems
•
absolute angle and angle change
•
•
stable operation over long time
automotive electronic (steering,
control, pedal positioning, etc
•
high temperature range up to +160°C
•
contactless rotary switches and potentiometer
•
automatic adjustment
-VO1(cos)
1
8
GND (bridge 1)
-VO2 (sin)
2
7
GND2 (bridge 2)
VCC2(bridge 2)
3
6
+VO2 (sin)
VCC1 (bridge 1)
4
5
+VO1 (cos)
throttle
Ordering Information
Device
Reel size
(Inches)
Tape width
(mm)
Quantity
per reel
Device
marking
ZMT32TA
7
12
1,000
ZETEX
ZMT32
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
1
www.zetex.com
ZMT32
Absolute maximum ratings
Parameter
Symbol
Limit
Unit
Supply Voltages
Vcc1 and Vcc2
10
V
Single Bridge Current
Icc1 or Icc2
4
mA
Operating Temperature
Range
TA
-40 to +160
°C
Storage Temperature
Range
Tstg
-55 to +175
°C
Recommended operating conditions
Symbol
Parameter
Vcc1, Vcc2
Supply Voltages
Hrot
Applied Magnetic Field Strength
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
Min
8
2
Typ
Max
Unit
5
8.5
V
25
kA/m
www.zetex.com
ZMT32
Electrical characteristics
General test conditions (unless otherwise noted)
TA= +23±5oC, VCC1=VCC2 = +5V, HROT=25kA/m(†), k=100•(VPO1/VPO2) with VCC1=VCC2
SYMBOL
Sα1 or Sα2
PARAMETER
Sensitivities (zero crossing)
Peak Output Voltages
VPO1 or VPO2
(sinusoidal signals)
k
Amplitude bridge matching
Temperature coefficient of
TCk
amplitude bridge matching
RB1
or
RB2
MAX
UNIT
mV/V/deg
40
50
60
mV
99.77
100
100.23
%
-0.008
+0.008
%/K
TA = -40°C
2017
3040
TA = 23°C
2500
TA = -40 to +160°C
no HROT
TA = +160°C
TC of Bridge Resistances
or
Peak to peak output swing
∆VO2/VCC2A
HROT = 8 kA/m(†)
VOFF1/VCC1A
or
Output offset voltage
HROT = 8 kA/m (†)
A
no HROT
Angular Inaccuracy
∆αHA
Angular hysteresis
Iiso1-2
Isolation Bridge Current
+0.32
+0.36
19.2
16
TA = +160°C
6.7
TA = 23°C
16
20
24
-0.35
-0.32
-0.28
24
13.4
-1.25
+1.25
TA = +160°C
-1.55
+1.55
TA = 23°C
HROT = 8 kA/m(†)
no HROT
0
%/K
30.4
20
TA = -40°C
-1
-2
-4
Ω
5114
TA = 23°C
TC of output offset voltage
∆αA
3600
TA = -40°C
TC of peak to peak output
swing
TCVOB
3000
3345
+0.28
∆VO1/VCC1A
TCVOFFB
TYP (*)
0.35
α1=135°, α2=0°
Bridge resistances
TCRBB
VOFF2/VCC2
MIN
CONDITIONS
mV/V
%/K
mV/V
0
0
0
+1
+2
+4
µV/V/K
0.05
0.2
deg
0.1
deg
0.5 (‡)
deg
0.1
µA
NOTES:
(*) Typical values apply to an ambient temperature of 23oC
(†) See point “Magnetic Field Tests” below
(‡) The accurate control of this parameter (Limmax=0.1deg, HROT=25kA/m) takes place by means of sample tests
A:
Output characteristic definitions
∆VO1/VCC1 = (VOMAX1 – VOMIN1)/VCC1 or/ ∆VO2/VCC2 = (VOMAX2 – VOMIN2)/VCC2
VOFF1/VCC1 = ½(VOMAX1 + VOMIN1)/VCC1 or/ VOFF2/VCC2 = ½(VOMAX2 + VOMIN2)/VCC2
∆αH = MAX | αLEFT TURN – αRIGHT TURN |
∆α = MAX | αo – α |
(max. angular difference between left and right turn)
(max. angular difference between actual value αoand measured angle,
without offset error)
B: Temperature coefficient (TC) equations
T1 = -25°C,
T0 = +25°C,
ΔVO
ΔVO
(T2 ) −
(T1)
VCC
VCC
1
×
TCVO =
× 100%
ΔVO
T2 − T1
(T0 )
VCC
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
T2 = +125°C
where
ΔVO
(Tn )
VCC
3
is the peak-peak output voltage at temperature Tn
www.zetex.com
ZMT32
TCR B =
R (T ) − R B (T1)
1
× B 2
× 100%
T2 − T1
R B (T0 )
TCVOFF =
where
RB(Tn) is the bridge resistance at temperature Tn
VOFF( T 2) − VOFF( T1)
(T2 − T1 )
where VOFF(Tn) is the output offset voltage at temperature Tn
Magnetic field tests
For these tests a rotating magnetic field is generated and the output signals of both bridges are measured at
four different field angles for right rotation as well as for left rotation. Using these measured output signals
the diameter and the center coordinates of the best circle are calculated. They correspond to the output
voltage range and the offset voltage. Furthermore the field angles for both rotation directions and angular
hysteresis are calculated
⎛V ⎞
[measured angle] = α = arctan⎜⎜ O2 ⎟⎟
⎝ VO1 ⎠
Method
The data pairs are transformed onto a unit circle starting from their position in the data collection
for determining direction information or angle information.
It must be evaluated with four pair values (cos, sin) on a right rotation (magnetic field rotation)
and four pair values (cos, sin) on a left rotation (magnetic field rotation).
The field rotation steps are:
Æ start in 180° position
§ right rotation to 22.5° with measurement of sensor outputs
§ right rotation to 67.5° with measurement of sensor outputs
§ right rotation to 112.5° with measurement of sensor outputs
§ right rotation to 157.5° with measurement of sensor outputs
§ right rotation to 0° (360°) , stop , reversal
§ left rotation to 157.5° with measurement of sensor outputs
§ left rotation to 112.5° with measurement of sensor outputs
§ left rotation to 67.5° with measurement of sensor outputs
§ left rotation to 22.5° with measurement of sensor outputs , end position
General description of tests with external magnetic field.
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
4
www.zetex.com
ZMT32
Operating principle
0
GND1
8
Hrot
O
+VO2
6
+VO1
5
Bridge
2
Bridge
1
α = 0°
1
GND2
7
␣
2
-VO2
1
-VO1
3
VCC2
4
VCC1
When a common-magnetic field is applied through the
ZMT32 the 2 internal magneto-resistive bridges are
affected slightly differently due to their 45° rotation to
one another. This 45° rotation enables the ZMT32 to
determine angular position, of a rotating magnetic
field.
GND1
When a rotating magnetic field is applied to the ZMT32
it will output 2 sinusoidal voltages that are:
-VO2
GND2
•
proportional to the field strength applied
Vcc2
+VO2
•
proportional to the supply voltage applied,
Vcc1
+VO1
•
rotating at twice the angular position
•
90° apart (as seen below).
1
-VO1
By taking the arcTan of the ratio of VO2 to VO1 the
angular position of the magnetic field can be
determined.
Characteristic output curves VO1, VO2
10
Cos 2α
Output voltage (mV/V)
5
Sin 2α
0
-5
-10
Sensor bridge 2
Sensor bridge 1
-15
0
45
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
90
135
180
225
5
270
315
360
www.zetex.com
ZMT32
Typical characteristics
Accuracy variance with field strength
Angle accuracy
1.4%
VCC1=VCC2=+5V
1.2%
TA=23oC
1.0%
k=100
0.8%
0.6%
0.4%
0.2%
0.0%
0
10
20
30
40
50
HROT - Field strength (kA/m)
Output voltage (mV/V)
Output variance with magnetic field strength
25
20
VCC1=VCC2=+5V
TA=23oC
15
k=100
10
5
0
0
10
20
30
40
50
HROT - Field strength (kA/m)
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
6
www.zetex.com
ZMT32
Typical characteristics
Output voltage versus temperature
Output voltage (mV/V)
35
MAX
30
MIN
25
20
15
VCC1=VCC2=+5V
10
TA=23oC
k=100
5
0
-50
-25
0
25
50
75
100
125
150
175
Temperature (oC)
Bridge resistance (Ω)
Bridge resistance versus temperature
6000
VCC1=VCC2=+5V
5000
TA=23oC
4000
k=100
3000
2000
MAX
1000
MIN
0
-50
-25
0
25
50
75
100
125
150
175
Temperature (oC)
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
7
www.zetex.com
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
8
1
R4
R3
8
SIN
R2
R1
R3
R4
COS
R1
4
top view
ZMT32T8
5
R2
+
-
+
VOUT2
A
A
fixed 45 degree phase
difference between
outputs 1 and 2
VOUT1
D
D
␮p
tan
GND
result of angle
measurement
+VCC
ZMT32
Typical application
www.zetex.com
ZMT32
Package outline - SM-8
Soldering footprint
2.8
0.110
4.6
0.181
6.8
0.268
mm
inches
0.95
0.037
DIM
Millimeters
Inches
DIM
1.52
0.060
Millimeters
Inches
Min.
Max.
Typ.
Min.
Max.
Typ.
Min.
Max.
Typ.
Min.
Max.
Typ.
A
-
1.7
-
-
0.067
-
e1
-
-
4.59
-
-
0.1807
A1
0.02
0.1
-
0.0008
0.004
-
e2
-
-
1.53
-
-
0.0602
b
-
-
0.7
-
-
0.0275
He
6.7
7.3
-
0.264
0.287
-
c
0.24
0.32
-
0.009
0.013
-
Lp
0.9
-
-
0.035
-
-
D
6.3
6.7
-
0.248
0.264
-
␣
-
15°
-
-
15°
-
E
3.3
3.7
-
0.130
0.145
-
␤
-
-
10°
-
-
10°
Note: Controlling dimensions are in millimeters. Approximate dimensions are provided in inches
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
9
www.zetex.com
ZMT32
Definitions
Product change
Zetex Semiconductors reserves the right to alter, without notice, specifications, design, price or conditions of supply of any product or
service. Customers are solely responsible for obtaining the latest relevant information before placing orders.
Applications disclaimer
The circuits in this design/application note are offered as design ideas. It is the responsibility of the user to ensure that the circuit is fit for
the user’s application and meets with the user’s requirements. No representation or warranty is given and no liability whatsoever is
assumed by Zetex with respect to the accuracy or use of such information, or infringement of patents or other intellectual property rights
arising from such use or otherwise. Zetex does not assume any legal responsibility or will not be held legally liable (whether in contract,
tort (including negligence), breach of statutory duty, restriction or otherwise) for any damages, loss of profit, business, contract,
opportunity or consequential loss in the use of these circuit applications, under any circumstances.
Life support
Zetex products are specifically not authorized for use as critical components in life support devices or systems without the express written
approval of the Chief Executive Officer of Zetex Semiconductors plc. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body
or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labelling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to
cause the failure of the life support device or to affect its safety or effectiveness.
Reproduction
The product specifications contained in this publication are issued to provide outline information only which (unless agreed by the
company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a
representation relating to the products or services concerned.
Terms and Conditions
All products are sold subjects to Zetex’ terms and conditions of sale, and this disclaimer (save in the event of a conflict between the two
when the terms of the contract shall prevail) according to region, supplied at the time of order acknowledgement.
For the latest information on technology, delivery terms and conditions and prices, please contact your nearest Zetex sales office.
Quality of product
Zetex is an ISO 9001 and TS16949 certified semiconductor manufacturer.
To ensure quality of service and products we strongly advise the purchase of parts directly from Zetex Semiconductors or one of our
regionally authorized distributors. For a complete listing of authorized distributors please visit: www.zetex.com/salesnetwork
Zetex Semiconductors does not warrant or accept any liability whatsoever in respect of any parts purchased through unauthorized sales channels.
ESD (Electrostatic discharge)
Semiconductor devices are susceptible to damage by ESD. Suitable precautions should be taken when handling and transporting devices.
The possible damage to devices depends on the circumstances of the handling and transporting, and the nature of the device. The extent
of damage can vary from immediate functional or parametric malfunction to degradation of function or performance in use over time.
Devices suspected of being affected should be replaced.
Green compliance
Zetex Semiconductors is committed to environmental excellence in all aspects of its operations which includes meeting or exceeding
regulatory requirements with respect to the use of hazardous substances. Numerous successful programs have been implemented to
reduce the use of hazardous substances and/or emissions.
All Zetex components are compliant with the RoHS directive, and through this it is supporting its customers in their compliance with
WEEE and ELV directives.
Product status key:
“Preview”
Future device intended for production at some point. Samples may be available
“Active”
Product status recommended for new designs
“Last time buy (LTB)”
Device will be discontinued and last time buy period and delivery is in effect
“Not recommended for new designs” Device is still in production to support existing designs and production
“Obsolete”
Production has been discontinued
Datasheet status key:
“Draft version”
This term denotes a very early datasheet version and contains highly provisional information, which
may change in any manner without notice.
“Provisional version”
This term denotes a pre-release datasheet. It provides a clear indication of anticipated performance.
However, changes to the test conditions and specifications may occur, at any time and without notice.
“Issue”
This term denotes an issued datasheet containing finalized specifications. However, changes to
specifications may occur, at any time and without notice.
Zetex sales offices
Europe
Americas
Asia Pacific
Corporate Headquarters
Zetex GmbH
Kustermann-Park
Balanstraße 59
D-81541 München
Germany
Telefon: (49) 89 45 49 49 0
Fax: (49) 89 45 49 49 49
[email protected]
Zetex Inc
700 Veterans Memorial Highway
Hauppauge, NY 11788
USA
Zetex (Asia Ltd)
3701-04 Metroplaza Tower 1
Hing Fong Road, Kwai Fong
Hong Kong
Zetex Semiconductors plc
Zetex Technology Park, Chadderton
Oldham, OL9 9LL
United Kingdom
Telephone: (1) 631 360 2222
Fax: (1) 631 360 8222
[email protected]
Telephone: (852) 26100 611
Fax: (852) 24250 494
[email protected]
Telephone: (44) 161 622 4444
Fax: (44) 161 622 4446
[email protected]
© 2008 Published by Zetex Semiconductors plc
Issue 1 - June 2008
© Zetex Semiconductors plc 2008
10
www.zetex.com