TDK CXA-0474 Dimming/connector type Datasheet

1
Dimming/Connector Type
CXA-0474
■ Features
■ Applications
●2-output
●Applicable panel size*: 10 to 12 inches
●With brightness control function (Pulse Wide Modulation mode).
●With shut down function.
●With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator(a terminal and a pattern),
an anti-dust measure by silicone application is taken.
(Notice) Applicable panel size becomes a standard.
CXA-0474 Specifications(Please refer to each specification before use)
Electrical Characteristics
Item
Unit
Output Current mArms
Symbol
Iout
(Maximum dimmer)
Iout
(Minimum dimmer)
A
mA
kHz
Frequency
Hz
Open Circuit Voltage Vrms
Iin1
Iin2
Freq1
Freq2 (Duty frequency)
Vopen
Alarm Signal
Vst
Input Current
V
min
4.5
4.5
1.5
1.5
63.5
241
1750
4.5
-
Specification
typ
5.0
5.0
2.5
2.5
0.6
67.5
255
1850
5
0
max
5.5
5.5
3.5
3.5
1.0
1
72.0
268
1950
5.5
0.5
Vin(V) Vrmt(V)
12 0.6
5
12 0.6
5
12 0.6
5
12 0.6
5
12 0.6
5
12 0.6
0
12 0.6
5
12 0.6
5
11.4min.
5
12 0.6
5
12 0.6
5
Condition
Vbr(V) Rbr(kΩ )
2.5
10
0
0
2.5
10
2.5
10
2.5
10
0
2.5
10
2.5
10
2.5
10
Ta(℃ ) RL(kΩ )
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
110
-10 to +70
∞
-10 to +70
∞
-10 to +70
110
Remark
Voltage dimmer (*1)
Volume dimmer (*1)
Voltage dimmer (*1)
Volume dimmer (*1)
Remote ON
Remote OFF
Open load
In case of lamp anomaly (*2)
On a normal operation (*2)
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
Other Specifications
Dimming Function
Operating Temperature
Storage Temperature
Operating Humidity Ratio
Safety Standard
Weight
Dimensions(WxDxH)
Fused Input
Remote ON / OFF
Alarm Signal Function
Shutdown Function
℃
℃
RH%
g
mm
Yes
-10 to +70
-30 to +85
95Max
ー
22
114x25x8.5 (*3)
Yes
Yes
Yes
Yes
Silicone Coating on
High Voltage Area
■ Conformity to RoHs Directive
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
Yes
(*3) These dimensions are indicated the maximum only H. Others are typical values.
・All specifications are subject to change without notice.
001-01/20080228/etl_cxa_0474
2
CXA-0474
Outline Drawing
Example of label marking
Product name, Lot No., Country of origin, TDK-Lambda logotype
Silicone
High-voltage generator ※
(The entire surface within a range of 62mm away from the end of the basein)
※From high-voltage generator, please secure space distance more than 3mm in top and bottom right and left.
unit:mm
Connector
Connector
number
Part number
Model/Material
Quantity
Remarks
①
Printed circuit board PCB
Composite(CEM-3)
1
UL94V-0 t=1.0
ー
②
Input connector CN1
53261-0871
1
Molex Inc.
51021-0800
③
Output connector CN2
JST Mfg. Co., Ltd.
BHR-04VS-1
SM03(7-D1)B-BHS-1-TB(LF)
(SN) 1
Recommended applicable connector
Terminal Numbers And Functions
Output side CN2
Input side CN1
Terminal
number
CN1-1
CN1-2
CN1-3
CN1-4
CN1-5
CN1-6
CN1-7
Symbol
Vin
GND
Rated voltagex
Remarks
12 0.6V
Power input
0V
Ground
0V/2.5V to Vin
Remote terminal
0 to 0.4V:OFF
2.5 to Vin :ON
Open:ON
Rbr1/Vbr 0 to 2.5V/0 to 10kΩ
Dimmer terminal 1
Vrmt
Rbr2
Vst
CN1-8
(Output)
0 to 10kΩ
Dimmer terminal 2
0V/5V
Alarm output Lump open:5V
All specifications are subject to change without notice.
Terminal
number
Symbol
Rated voltage
Remarks
CN2-1
VHIGH1
550Vrms
Output 1
CN2-2
VHIGH2
550Vrms
Output 2
CN2-3
N.C.
ー
N.C.
CN2-4
VLOW
(2V)
Output 1,2 return
3
CXA-0474
Connections
RL:Load resistance(7W minimum)
Operate as follows by switching SW1.
SW1
Unit operation
a
Operation
b
Does not operate
Open
Operate as follows by switching SW2.
SW2
Unit operation
a
Voltage dimmer
Vbr=0 to 2.5V
Vbr=2.5V: Maximum brightness
b
Volume dimmer
VR=0 to 10kΩ
VR=10kΩ: Maximum brightness
Operation
Protection circuit operation
Load condition
Alarm output
※1
(CN1-8 )
Shut-down function ※ 2
Normal condition
0.5V max.
Does not shut down
When 1 load
(lamp) is run-out
5 0.5V
Does not shut down
When 2 loads
(lamps) are run-out
5 0.5V
Shut down
※1: In the case of low mode, and more than one of SW3-SW5 in
the connection diagram was open, output alarm signal of 5V.
※2: When all lamps were opened, this inverter has included
protective function to stop operation in about 3 seconds.
・All specifications are subject to change without notice.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK:
CXA-0474
Similar pages