Battery BC28-12 Absorbent glass mat technology for efficient gas recombinatino Datasheet

VRLA Rechargeable Battery
BC28-12
Measures
Technology
Values
Innovation
(BC28-12FR)
FEATURES
Maintenance free(no water topping-up required)
No free acid(Non-spillable battery)
Can be used in any orientation(excluding used inverted)
Absorbent Glass Mat technology for efficient gas recombination
Its design life is up to 5 years in floating application
APPLICATION
UPS
Wheelchairs
Lawn Mowers
Electronic Medical Equipment
Golf-Carts
SPECIFICATIONS
Nominal Voltage
BC28-12:
ABS: UL 94-HB (Dark gray color)
BC28-12FR:
ABS: UL 94-V0 (Light gray color)
7900g(17.42lbs.)
B1 (Fitting M5 bolt & nut) , T2 and I1 are optional
Max. Discharge Current
420 A (5 sec.)
8.4 A
0oC~40oC(32oF~104oF)
-20oC~50oC(-4oF~122oF)
-20oC~40oC(-4oF~104oF)
OUTER DIMENSIONS mm(inch)
14m
CE
JIS C 8702
GB/T 19639
(Fully Charged )
Length (L)
175±1.5(6.89±0.06)
UL
IEC61056
Width (W)
166±1.5(6.54±0.06)
Container Height (H)
123±1.5(4.84±0.06)
Total Height (TH)
125±1.5(4.92±0.06)
TERMI NAL TYPE
Terminal B1
12.0(0.47)
3.4(0.13)
2.0(0.08)
[M5 BOLT & NUT]
Terminal I1
Terminal T2
5.5(0.22)
Internal Resistance
< 3% per month (25 C)
11.0(0.43)
Self Discharge
o
M5x0.8
7.95(0.31)
2.0(0.08)
Discharge
Storage
ISO14001
6.35(0.25)
Charge
ISO 9001
0.8(0.03)
Max. Charge Current
Operating Temperature
Range
28.0 Ah
26.6 Ah
23.8 Ah
16.8 Ah
20 Hour Rate (1400mA, 10.5V)
10 Hour Rate (2660mA, 10.5V)
5 Hour Rate (4760mA, 10.5V)
1 Hour Rate (16800mA,9.3V)
Approx. Weight
Terminals
CONTAINER MATERIAL
5.0(0.20)
Nominal Capacity
12V
[M5 BOLT & NUT]
Terminal Hardware Initial Torque:
B1(2.5Nm±5%),I1(4.0Nm±5%)
o
o
BC28-12 (BC28-12FR) discharge characteristics (25 C/77 F)
Battery Charging Characteristics
(Typical examp le of t he charge characteristics for the standby us e)
13.0
0.21
15.0
0.18
14.0
140
10.0
0.6CA
9.0
0.15
0.12
0.09
0.06
120
Charge voltage
13.0
100
olume
Charge v
1 Discharge
100%(0.05CA x 20h)
50%(0.05CA x 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
3 Temperature:25℃(77℉)
12.0
11.0
10.0
80
60
40
Charge volume(%)
0.17CA 0.095CA 0.05CA
0.25CA
Charge voltage(V)
11.0
Charge current(CA)
Terminal Voltage(V)
12.0
8.0
2.5CA 2CA
7.0
1CA
0.03
20
Charge current
1
2
3
5
10
20 30
60
2
3
5
10
20 30
0
0
Hr
Min
0
5
10
15
20
0
25
Charge time (hr)
Discharge time
Effect Of Temperature On Long Term Float Life
Application
Charging
method
Charging time
O
0.1CA, 25 C
(h)
Charging Temperature Max. charging
compensation
current
Voltage
coefficient of
(CA)
at 25OC
voltage
100%
50%
(V/cell) charging
(mV/ OC/cell)
discharge discharge
Constant
voltage & 2.25~2.30
Constant
current
charging
For
(with current
cycle service restriction) 2.40~2.50
For standby
power Source
-3
0.3
24
Temp
( OC)
20
Life expectancy(year)
Charging Procedure
0~40
(32~ 104 OF)
-4
0.3
16
10
8
6
5
4
3
2
1
0.5
20
68
10
30
86
50°C
122°F
40
104
Battery temperature
Constant power discharge characteristics at 25 oC/77 oF
Discharge
Time
Charging voltage :
2.275V/cell
5 Min
10 Min
1.80V
703.7
1.75V
790.5
1.70V
Unit: W
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
573.8
468.5
317.3
199.7
81.60
56.27
31.47
16.53
621.5
489.9
329.6
205.7
83.27
57.13
31.93
16.80
865.3
642.9
504.7
337.1
209.4
84.00
57.40
32.07
16.87
1.65V
904.3
659.3
516.6
341.8
211.9
84.53
57.60
32.20
16.93
1.60V
934.2
672.6
526.7
345.3
214.1
85.13
57.80
32.20
16.93
F.V.
(V/cell)
Constant current discharge characteristics at 25 oC/77 oF
F.V.
(V/cell)
Discharge
Time
5 Min
Unit: A
10 Min
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
64.1
51.7
41.9
27.1
16.8
6.80
4.67
2.60
1.33
1.75V
73.3
56.1
43.8
28.2
17.3
6.93
4.73
2.67
1.40
1.70V
80.2
58.1
45.1
28.9
17.6
7.00
4.80
2.67
1.40
1.65V
85.4
60.6
46.2
29.3
17.8
7.07
4.80
2.67
1.40
1.60V
89.9
62.9
47.1
29.5
18.0
7.07
4.80
2.67
1.40
All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/1
USA:
B&B BATTERY(USA) INC.
6415 RANDOLPH ST.COMMERCE,CA,90040 U.S.A.
TEL:1-323-278-1900.1-800-278-8599
FAX:1-323-278-1268
E-Mail:[email protected]
CHINA FACTORY:
B.B. BATTERY CO., LTD.
CHENG DONG TRIAL AREA,HUANG GANG,
RAOPING, GUANG DONG,CHINA,515700
TEL:86-768-7601001-2
FAX:86-768-7601469
E-Mail:[email protected]
Web Site: http://www.bb-battery.com
REV. Dec. 2010
EUROPE:
B&B BATTERY(EUROPE) B.V.
SUITE 8, HAAKSBERGWEG 33, 1101
BP AMSTERDAM,THE NETHERLANDS
TEL: 31-30-3200190
MOBILE: 886-933896989
E-Mail: [email protected]
JAPAN:
B&B BATTERY(JAPAN) CO., LTD.
1375-11 NARAHARA-MACHI,HACHIOJI,
TOKYO 193-0803,JAPAN.
TEL:81-426-25-6375
FAX:81-426-25-6375
E-Mail:[email protected]
HONG KONG:
B&B BATTERY(Hong Kong) Co.
TEL:852-2311-4918
FAX:852-2739-1182
E-Mail:[email protected]
TAIWAN:
B.B. BATTERY(TAIWAN) CO., LTD.
TEL:886-6-502-5150
FAX:886-6-589-8087
E-Mail:[email protected]
Powered by
B.B. Battery Co., Ltd.
Similar pages