Teledyne CS-37SXC-TS Failsafe transfer coaxial switch Datasheet

Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
PART NUMBER
DESCRIPTION
CCS-37S
Commercial Failsafe TRANSFER, DC-18GHz
CS-37S
Elite Failsafe TRANSFER, DC-18GHz
The CCS-37S/CS-37S is a long-life high performance transfer switch designed for use in 50 Ohms
coaxial transmission lines operating over frequencies ranging from DC to 18 GHz. The switch is designed
for minimum size compatible with SMA connector spacing.
The failsafe switches on this page are provided with a spring operated actuator which is particularly
desirable in applications where the switch is connected to one position (normally closed) most of the
time and only periodically switched to the alternate position. In this type of application, holding power is
required only when operating in the alternate position. Also, switching circuitry is simplified, since only
one DC circuit is required.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCS-37S
Elite Model, CS-37S
Form Factor
–40°C to 65°C
–55°C to 85°C
TRANSFER,
break before make
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Frequency Range
CCS-37S
CS-37S
DC–18 GHz
DC–18 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
50 Ohms
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
2.5 oz. (70.87g) (max.)
Operate Time
10 ms (max.)
Release Time
10 ms (max.)
Actuation Voltage Available
12
Actuation Current, max. @ ambient
380 300 250 200 mA
15
24
28 V
PERFORMANCE CHARACTERISTICS
Frequency
DC–5 GHz
5–10 GHz
10–13 GHz
13–15 GHz
15-18 GHz
0.1
0.2
0.4
0.6
0.6
Insertion Loss, dB,
max.
Isolation, dB, min.
VSWR , max.
90
80
80
80
80
1.1:1
1.3:1
1.3:1
1.6:1
1.6:1
PART NUMBERING SYSTEM
CCS-37 S 1 C -
T **
Options
Series
Connectors
Actuator Type
Actuator Voltage
Connector
S: SMA Female
Actuator Voltage
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
Actuator Type
0: Standard Contacts
C: Indicator Contacts
**SEE PARTS LIST ON PAGE 8
Options
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
M: Moisture Seal
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCS-37S/CS-37S Page 1
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
SCHEMATICS AND MECHANICAL OUTLINE
Analog
TTL
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
Indicators
H = 1.50 Max. STD Model
H = 1.75 Max. Indicator & Diode Model
H = 2.00 Max. 9-Pin D-Sub & TTL Model
1
6
“-S OPTION” 9-PIN D-SUB CONNECTOR (EXAMPLE:
9 PIN D-SUB PINOUT FOR FAILSAFE TRANSFER
TRUTH TABLE (with TTL option)
OPTIONS
Pin
No.
1
2
3
4
5
6
7
8
9
Basic
Indicators
+
-
+
-
CCS-37S/CS-37S Page 2
A
B
C
TTL
CCS-37S10-S)
Indicators &
TTL
Common
1
Common
1
Vsw
Vsw
A
B
C
Logic
Input
RF Path
Indicator
(if applicable)
1
0
J1-J2 & J4-J3
B&C
1
J1-J3 & J4-J2
A&C
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( 5-10 GHz )
0
0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( DC-5 GHz )
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.9
-1
5
-1
0
1
2
3
4
5
7
8
9
10
Frequency (GHz)
Frequency (GHz)
Insertion Loss ( 10-13 GHz )
Insertion Loss ( 13-15 GHz )
0
0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
6
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
-1
10
11
12
13
13
Frequency (GHz)
14
15
Frequency (GHz)
Insertion Loss ( 15-18 GHz )
0
Insertion Loss (dB)
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
15
16
17
18
Frequency (GHz)
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCS-37S/CS-37S Page 3
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( 5-10 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
Isolation ( DC-5 GHz )
-60
-80
-100
-120
-60
-80
-100
-120
-140
-140
0
1
2
3
4
5
5
6
7
Frequency (GHz)
Isolation ( 10-13 GHz )
9
10
Isolation ( 13-15 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
8
Frequency (GHz)
-60
-80
-100
-120
-60
-80
-100
-120
-140
10
11
12
13
-140
13
14
Frequency (GHz)
15
Frequency (GHz)
Isolation ( 15-18 GHz )
0
Isolation (dB)
-20
-40
-60
-80
-100
-120
-140
15
16
17
18
Frequency (GHz)
RF NOTES
CCS-37S/CS-37S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( 5-10 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
VSWR ( DC-5 GHz )
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
0
1
2
3
4
5
5
Frequency (GHz)
7
8
9
10
Frequency (GHz)
VSWR ( 10-13 GHz )
VSWR ( 13-15 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
6
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
10
11
12
13
13
Frequency (GHz)
14
15
Frequency (GHz)
VSWR ( 15-18 GHz )
2
1.9
1.8
VSWR
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1
15
16
17
18
Frequency (GHz)
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCS-37S/CS-37S Page 5
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
Power (W)
1000
800
600
400 STAN
DAR
DS
300
MA
200
SW
ITC
HES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCS-37S/CS-37S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode
limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to
the positive side of the coil and the anode is connected to
the negative side.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Date Code
All switches are marked with either a unique serial number
or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits.
The first two digits define the year and the last two digits
define the week of the year (YYWW). Thus, 1032 identifies
switches that passed through final inspection during the
32nd week of 2010.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive
current. For switches operating at 28 VDC, the approximate
actuator drive current at temperature, T, can be calculated
using the equation:
Failsafe
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
requires the continuous application of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
contacts linked to the actuator. They can be wired to digital
input lines, status lights, or interlocks. Unless otherwise
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
IT =
IA
[1 + .00385 (T-20)]
Where:
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
TRANSFER Switch
A four-port switch consisting of two independent pairs of
RF paths. These pairs are actuated simultaneously. This
actuation is similar to that of a double-pole double-throw
switch.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
© 2013 TELEDYNE RELAYS
SPECIAL FEATURE
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th
Order Frequency
870 MHz
893 MHz
847 MHz
824 MHz
Transfer
(800) 284-7007 • www.teledynecoax.com
3rd Order
Intermodulation
5th Order
Intermodulation
–103 dBm
–123 dBm
–146 dBc
–165 dBc
CCS-37S/CS-37S Page 7
CCS-37S\CS-37S\082013\Q3
Series CCS-37S/CS-37S
Miniature DC–18 GHz
Failsafe TRANSFER Coaxial Switch
COAX SWITCHES
FAILSAFE CCS-37S/CS-37S PART NUMBER LIST
PART NO.
*
PART NO.
1
CCS-37SXC
44
CS-37SX0-S
2
CCS-37SXC-D
45
CS-37SX0-T
3
CCS-37SXC-DM
46
CS-37SX0-TM
4
CCS-37SXC-DMS
47
CS-37SX0-TMS
5
CCS-37SXC-DS
48
CS-37SX0-TS
6
CCS-37SXC-M
7
CCS-37SXC-MS
8
CCS-37SXC-S
9
CCS-37SXC-T
10
CCS-37SXC-TM
11
CCS-37SXC-TMS
12
CCS-37SXC-TS
13
CCS-37SX0
14
CCS-37SX0-D
15
CCS-37SX0-DM
16
CCS-37SX0-DMS
17
CCS-37SX0-DS
18
CCS-37SX0-M
19
CCS-37SX0-MS
20
CCS-37SX0-S
21
CCS-37SX0-T
22
CCS-37SX0-TM
23
CCS-37SX0-TMS
24
CCS-37SX0-TS
25
CS-37SXC
26
CS-37SXC-D
27
CS-37SXC-DM
28
CS-37SXC-DMS
29
CS-37SXC-DS
30
CS-37SXC-M
31
CS-37SXC-MS
32
CS-37SXC-S
33
CS-37SXC-T
34
CS-37SXC-TM
35
CS-37SXC-TMS
36
CS-37SXC-TS
37
CS-37SX0
38
CS-37SX0-D
39
CS-37SX0-DM
40
CS-37SX0-DMS
41
CS-37SX0-DS
42
CS-37SX0-M
43
CS-37SX0-MS
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCS-37S/CS-37S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCS-37S\CS-37S\082013\Q3
Similar pages