FED40W FED40W SERIES DC-DC CONVERTER 4:1 WIDE INPUT RANGE UP TO 40Watts FEATURES APPLICATIONS • NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 2.00 X 1.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • SAFETY MEETS UL60950-1, EN60950-1, IEC60950-1, & EN50155 • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP OCP • RAILWAY SYSTEM • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT SCP OVP OTP LOW STANDBY POWER TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Model Number FED40-24S3P3W FED40-24S05W FED40-24S12W FED40-24S15W FED40-24S24W FED40-24D12W FED40-24D15W FED40-24D24W FED40-48S3P3W FED40-48S05W FED40-48S12W FED40-48S15W FED40-48S24W FED40-48D12W FED40-48D15W FED40-48D24W FED40-110S3P3W FED40-110S05W FED40-110S12W FED40-110S15W FED40-110S24W FED40-110D12W FED40-110D15W FED40-110D24W Input Range Output Voltage Output Current @Full Load Input Current @ No Load Efficiency Maximum Capacitor Load (1) VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 VDC 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 mA 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 mA 15 15 15 15 15 15 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 % 90 91 92 92 91 90 90 91 90 91 92 92 91 90 90 91 88 89 90.5 91 90 89 89 91 µF 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 PART NUMBER STRUCTURE FED40 Series Name 48 Input Voltage (VDC) 24: 9~36 48: 18~75 110: 43~160 S Output Quantity S: Single D: Dual 1 05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 24: 24 12: ±12 15: ±15 24: ±24 W Input Range 4:1 N HS Remote Control Option Heat-sink : Positive logic N: Negative logic www.PDUKE.com : No Heat-sink HS Heat-sink HC Heat-sink with Clamp 2014/10/14 FED40W INPUT SPECIFICATIONS Parameter Conditions 24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) 110Vin(nom) Operating input voltage range Start-up voltage Shutdown voltage Start up time Constant resistive load Input surge voltage 1 second, max. Input filter Remote ON/OFF Referred to –Vin pin OUTPUT SPECIFICATIONS Parameter Positive logic DC-DC ON (Standard) DC-DC OFF DC-DC ON Negative logic (Option) DC-DC OFF Input current of Ctrl pin Remote off input current Conditions Voltage accuracy Line regulation Load regulation Low Line to High Line at Full Load No Load to Full Load Cross regulation Voltage adjustability Asymmetrical load 25%/100% FL Single output Ripple and noise Measured by 20MHz bandwidth With a 0.1µF/50V X7R MLCC Temperature coefficient Transient response recovery time Over voltage protection Over load protection Short circuit protection 3.3Vout 5Vout 12Vout 15Vout 24Vout % of Iout rated; Hiccup mode Isolation voltage 1 minute Isolation resistance Isolation capacitance Switching frequency Safety meets 500VDC 2 Typ. Max. 9 18 43 24 48 110 36 75 160 9 18 43 -0.5 Min. Conditions Input to Output Input (Output) to Case www.PDUKE.com VDC VDC ms 50 100 VDC 170 Pi type Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 12VDC 0.5 mA 3 mA Typ. -1.0 -0.2 -0.5 -1.0 -5.0 -10 -10 75 100 150 Max. Unit +1.0 +0.2 +0.5 +1.0 +5.0 +10 +20 100 125 200 +0.02 % % % % % mVp-p %/℃ 250 µs 3.9 6.2 15 VDC 20 30 150 % Continuous, automatics recovery Min. Typ. 1600 1600 1 225 MIL-HDBK-217F, Full load. Unit VDC 8 16 40 60 60 -0.02 25% load step change Zener diode clamp GENERAL SPECIFICATIONS Parameter Case material Base material Potting material Weight MTBF Single Dual Dual 3.3Vout, 5Vout, 12Vout 15Vout, 24Vout 3.3Vout, 5Vout 12Vout, 15Vout 24Vout Min. Max. Unit VDC 250 GΩ pF kHz UL60950-1 EN60950-1 IEC60950-1 EN50155 Copper FR4 PCB Silicone (UL94 V-0) 32g (1.13oz) 9.073 x 105 hrs 1500 275 2014/10/14 FED40W ENVIRONMENTAL SPECIFICATIONS Parameter Operating ambient temperature Maximum case temperature Over temperature protection Storage temperature range Thermal impedance (1) Conditions Min. Typ. -40 Max. Unit +85 +105 +115 -55 Vertical direction by natural convection (20LFM) Without Heat-sink With Heat-sink Thermal shock Shock Vibration Relative humidity +125 10.8 10.3 /W MIL-STD-810F EN61373, MIL-STD-810F EN61373, MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI (2) ESD Radiated immunity Fast transient (3) Surge (3) Conducted immunity Conditions EN55011,EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Level Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV ± 2kV 10 Vr.m.s Class A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Note: 1. 2. 3. Test by minimum input and constant resistive load. The standard modules meets EMI Class A or Class B with external components. For further information, please contact with P-DUKE. The external input components are required if the module has to meet EN61000-4-4, EN61000-4-5. The FED40-24W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ58A, 58V, 3000Watt peak pulse power) to connect in parallel. The FED40-48W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ120A,120V, 3000Watt peak pulse power) to connect in parallel. The FED40-110W recommended an aluminum electrolytic capacitor (Ruby-con BXF series, 68µF/200V 3pcs in parallel) and a TVS (SMDJ90A, 90V, 3000Watt peak pulse power 2pcs in series connection ) to connect in parallel CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE 3 FED40-48S05W Derating Curve FED40-48S05W Derating Curve with Heat-sink FED40-48S05W Efficiency VS Input Voltage FED40-48S05W Efficiency VS Output Load www.PDUKE.com 2014/10/14 FED40W MECHANICAL DRAWING PIN CONNECTION PIN SINGLE 1 + Vin 2 - Vin 3 Ctrl 4 + Vout 5 - Vout 6 Trim DUAL + Vin - Vin Ctrl + Vout Common - Vout EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. TRIM UP TRIM DOWN 6 6 RU 5 RD 4 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) 4 www.PDUKE.com 2014/10/14