Click on Series name for product info on aimtec.com Series AMLD-RZ Up to 1000mA | LED Driver FEATURES: • Step Down DC/DC LED driver • Constant current output • Ultra Wide (7:1) input voltage range • High efficiency up to 97% • Operating Temperature range -40ºC to +85ºC • Open and Short LED Protection • PWM / Digital Voltage dimming • Output power up to 56 Watts Models Single output Input Voltage (V) Model Output Voltage (V) Maximum Rated Current (mA) Max Capacitive Load (uF) Efficiency (%) Ripple & Noise (mV p-p) AMLD-6030-RZ 9-60 2-56 300 2.2 97 250 AMLD-6035-RZ 9-60 2-56 350 2.2 97 300 AMLD-6050-RZ 9-60 2-56 500 2.2 97 350 AMLD-6060-RZ 9-60 2-56 600 2.2 97 400 AMLD-6070-RZ 9-60 2-56 700 2.2 97 400 AMLD-60100-RZ 9-60 2-56 1000 2.2 97 450 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Absolute Maximum Rating Peak Input Voltage time DC/DC ON (Leave open if not used) DC/DC OFF (or short pins 2,3,4) Maximum Remote pin drive current Quiescent Current in Shutdown mode On/Off Control (Digital Control) Output current adjustment Output Specifications Parameters Current accuracy Output Voltage range Output current Short Circuit protection Temperature coefficient General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Thermal Impedance Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum Soldering Temperature NOTES: Nominal Typical 48 9-60 Capacitor ON –Open or 2.5V< Vadj <5V OFF(shutdown) – Vadj <0.8 Vadj = 0 - 5V Vin = 60V Max PWM Frequency 1KHz 1 to 100 Conditions Typical ±5 2-56 Maximum Units 65 500 VDC ms <1 3 mA mA % Maximum V input = 60V Vin – Vout > 4V Regulated at the rated current for each model ±0.03 Conditions 100% load Typical 40-1000 See derating chart -40 to +85 -40 to +125 Free air convection +30 Free air convection VDC Maximum 105 95 Non-Conductive Black Plastic (UL94V-0 rated) 17.7 1.25 x 0.80 x 0.49 inches 31.75 x 20.32 x 12.45 mm > 2 000 000hrs (MIL-HDBK-217 F at +25 oC) 1.5 mm from case for 10sec. 260 Units % VDC o %/ C Units KHz o C o C o C o C/W % RH g o C 1. Reversed polarity at the input power will damage the driver. The input ground must not be connected to the negative output. 2. Maximum output open voltage is equal to input voltage. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMLD-RZ Up to 1000mA | LED Driver Safety Specifications Parameters Standards CE EN 55015 : 2006+A1 : 2007+A2 : 2009 EN 61547 : 2009 (Designed to meet EN 60950-1) Pin Out Specifications Pin 2 3 4 9 11 14 16 22 23 Single - V Input - V Input Vadj - V Output - V Output + V Output + V Output + V Input + V Input - DC Supply - DC Supply PWM/ON/OFF or not used LED Cathode connection LED Cathode connection LED Anode connection LED Anode connection + DC Supply + DC Supply Dimensions 31.75 (1.25) 22.86 (0.90) 2 3 20.32 (0.80) 4 9 11 15.24 (0.60) Bottom View 23 22 16 2.54 (0.1) 12.45 (0.49) 14 5.08 (0.2) Mechanical Tolerances 3.00 (0.12 Case tolerance ± 0.25mm or ± 0.01 inches Pin tolerance ± 0.05 or ± 0.002 0.50 (0.02) www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMLD-RZ Up to 1000mA | LED Driver Derating Free Air Convection Output Power (%) 100 AMLD-6030-RZ AMLD-6035-RZ 80 60 AMLD-6050-RZ AMLD-6060-RZ AMLD-6070-RZ AMLD-60100-RZ Safe Operating Area 40 20 0 - 40 - 20 0 20 40 60 71 80 85 100 Ambient Temperature º C Typical Application Circuits Vout+ + Vin- (or GND) PWM 22 23 2 3 14 16 AIMTEC AMLD-60xx-RZ 4 LED Strings Vin+ 9 11 Vout- 5V 0V Vadj (PWM / Dim / On / Off) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only