Click on Series name for product info on aimtec.com Series AMEPR15D-AZ up to 1A | AC-DC LED Driver FEATURES: Models Single Output Model AMEPR15D-5030AZ+Suffix② AMEPR15D-4835AZ+Suffix② AMEPR15D-3650AZ+Suffix② AMEPR15D-2470AZ+Suffix② AMEPR15D-15100AZ+Suffix② AC-DC Constant Current LED Driver Input range 90-264VAC/47-440Hz High Efficiency up to 82% Operating temperature -20 to 80°C Total Harmonic Distortion < 20% 5 Year Limited Warranty Max Output Power (W)① Output Voltage Range (V) 15 15.8 18 16.8 15 36-50 30-48 24-36 12-24 8-15 No Load Output Voltage (V max.) Leading or Trailing Edge Triac IP20 or IP67 Case Active PFC with TRIAC Dimmable② SCP, Over Load Protection Output Current (A) Input Voltage (VAC/Hz) 0.3 0.35 0.5 0.7 1 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 62 62 52 34 23 Efficiency (%) 115 VAC 230 VAC 82 82 81 81 80 82 82 82 82 79 Exceeding the maximum output power will permanently damage the converter. ① ② Model Nomenclature for Ordering: Add Suffix “-UD” Add Suffix “-UW” Add Suffix “-110D” Add Suffix “-110W” Add Suffix “-220D” Add Suffix “-220W” Universal AC input 90-264VAC, (no TRIAC dimming option), IP20 Universal AC input 90-264VAC, (no TRIAC dimming option), IP67 AC input 90-135VAC, IP20, 115VAC typical value AC input 90-135VAC, IP67, 115VAC typical value AC input 180-264VAC, IP20, 230VAC typical value AC input 180-264VAC, IP67, 230VAC typical value NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/termssale AMEPR15D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Inrush current <2ms (cold start) Conditions Typical 115VAC 230VAC 15 25 25 400 250 0.9 0.9 Leakage current AC current Power Factor External fuse 115VAC 230VAC 115VAC 230VAC Recommend Slow Blown Type Start up time www.aimtec.com F 052.1e R3.R Maximum A mA mA 1 A 200 ms Tel: +1 514 620 2722 1 of 5 Units Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC LED Driver Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±7 Line regulation LL-HL ±10 Load regulation 0-100% load ±7 3 Ripple & Noise ③ Hold-up time 1 Minimum load voltage See the models table ③ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. % % % V p-p ms Isolation Specifications Parameters Conditions Tested I/O voltage Isolation resistance Typical 3sec Maximum Units 3000 VAC MΩ >1000 General Specifications Parameters Conditions Typical Switching frequency Over load protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum 65 110 110 Auto recovery Units KHz % % >105°C With derating over 55°C (for IP67 case) Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Wires Weight Dimensions (L X H X W) MTBF oC -20 to +80 100 oC oC % / oC -40 to +95 ±0.02 Free air convection 95 Plastic UL1015 Input 18AWG*10CM / Output 20 AWG*10CM IP20 160 IP67 200 133 x 33 x 30mm (5.24 x 1.30 x 1.18 inch) >400,000 hrs (MIL-HDBK-217F at t=+25°C) % RH g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation www.aimtec.com F 052.1e R3.R Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC LED Driver Safety Specifications Parameters Agency approvals Standards cULus, CE, FCC EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024, FCC Part 15 Subpart B, Class B, ANSI C63.4 :2003 Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 1 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Dimensions Free Air Convection Temperature graph 55 º C Output Power % 100 80 Safe Operating Area 60 40 20 0 - 25 - 20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC LED Driver Triac Dimming Feature Triac Device LED Lighting Application LED Driver AC Line (Brown) Aimtec Neutral (Blue) Red (+) Black (‐) Earth Ground Triac Dimming Notes: A‐ The triac device can be installed on either Line or Neutral B‐ Aimtec LED drivers have been designed to function with a wide range of available Triac devices, however the following list of Triac devices have been tested. 1) Company: LUTRON Series: SKYLARK Model: SF‐10P‐WH (input voltage: 120Vac) Model: SF‐12P‐277‐WH (input voltage 277Vac) 2) Company LUTRON Series: DIVA Model: DVF‐103P‐WH (input voltage: 120Vac) Model: DVF‐103P‐277‐WH (input voltage: 277Vac) 3) Company BERKER Model: 2867 10 (input voltage:230Vac) If the power voltage range is 90~135Vac, triac suggested use model SF‐10P‐WH or DVF‐103P‐WH. If the power voltage range is 180~260Vac, triac suggested use model SF‐12P‐277‐WH or DVF‐103P‐277‐WH. www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC LED Driver Triac Dimming Performance AMEPR15D-2470AZ (mA) Dimming Performance(Input 110Vac) 800 700 621 600 675 NS‐1223B LUTRON DVCL‐ 15SP‐WH 558 500 387 400 300 307 200 100 60 100 80 0 20 40 60 (mA) 80 100 120 140 160 Angle Dimming Performance(Input 230 Vac) 800 701 700 626 607 600 572 NS‐1223C 664 Berker 286710 500 LUTRON LLSI‐ 502B‐FAW‐M 386 400 311 300 267 200 98 100 49 0 20 102 116 2 70 120 170 220 Angle Triac dimming performance is typical as with other models, for specific details on other model performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only