AIMTEC AMEPR15D-5030AZ-110W Up to 1a | ac-dc led driver Datasheet

Click on Series name for product info on aimtec.com
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
FEATURES:
Models
Single Output
Model
AMEPR15D-5030AZ+Suffix②
AMEPR15D-4835AZ+Suffix②
AMEPR15D-3650AZ+Suffix②
AMEPR15D-2470AZ+Suffix②
AMEPR15D-15100AZ+Suffix②










AC-DC Constant Current LED Driver
Input range 90-264VAC/47-440Hz
High Efficiency up to 82%
Operating temperature -20 to 80°C
Total Harmonic Distortion < 20%
5 Year Limited Warranty
Max
Output
Power
(W)①
Output
Voltage
Range
(V)
15
15.8
18
16.8
15
36-50
30-48
24-36
12-24
8-15
No Load
Output
Voltage
(V max.)
Leading or Trailing Edge Triac
IP20 or IP67 Case
Active PFC with TRIAC Dimmable②
SCP, Over Load Protection
Output
Current (A)
Input Voltage
(VAC/Hz)
0.3
0.35
0.5
0.7
1
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
62
62
52
34
23
Efficiency
(%)
115
VAC
230
VAC
82
82
81
81
80
82
82
82
82
79
Exceeding the maximum output power will permanently damage the converter.
①
②
Model Nomenclature for Ordering:
Add Suffix “-UD”
Add Suffix “-UW”
Add Suffix “-110D”
Add Suffix “-110W”
Add Suffix “-220D”
Add Suffix “-220W”
Universal AC input 90-264VAC, (no TRIAC dimming option), IP20
Universal AC input 90-264VAC, (no TRIAC dimming option), IP67
AC input 90-135VAC, IP20, 115VAC typical value
AC input 90-135VAC, IP67, 115VAC typical value
AC input 180-264VAC, IP20, 230VAC typical value
AC input 180-264VAC, IP67, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/termssale
AMEPR15D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Conditions
Typical
115VAC
230VAC
15
25
25
400
250
0.9
0.9
Leakage current
AC current
Power Factor
External fuse
115VAC
230VAC
115VAC
230VAC
Recommend Slow
Blown Type
Start up time
www.aimtec.com
F 052.1e R3.R
Maximum
A
mA
mA
1
A
200
ms
Tel: +1 514 620 2722
1 of 5
Units
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±7
Line regulation
LL-HL
±10
Load regulation
0-100% load
±7
3
Ripple & Noise ③
Hold-up time
1
Minimum load voltage
See the models table
③ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
%
%
%
V p-p
ms
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation resistance
Typical
3sec
Maximum
Units
3000
VAC
MΩ
>1000
General Specifications
Parameters
Conditions
Typical
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum
65
110
110
Auto recovery
Units
KHz
%
%
>105°C
With derating over 55°C
(for IP67 case)
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Wires
Weight
Dimensions (L X H X W)
MTBF
oC
-20 to +80
100
oC
oC
% / oC
-40 to +95
±0.02
Free air convection
95
Plastic
UL1015 Input 18AWG*10CM / Output 20 AWG*10CM
IP20 160
IP67 200
133 x 33 x 30mm (5.24 x 1.30 x 1.18 inch)
>400,000 hrs (MIL-HDBK-217F at t=+25°C)
% RH
g
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
www.aimtec.com
F 052.1e R3.R
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, FCC
EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024, FCC Part 15 Subpart B, Class
B, ANSI C63.4 :2003
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 1
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 2
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Dimensions
Free Air Convection
Temperature graph
55 º C
Output Power %
100
80
Safe Operating Area
60
40
20
0
- 25
- 20
0
20
40
60
80
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
Triac Dimming Feature
Triac Device
LED Lighting
Application
LED Driver
AC
Line (Brown)
Aimtec
Neutral (Blue)
Red (+)
Black (‐)
Earth
Ground
Triac Dimming Notes:
A‐ The triac device can be installed on either Line or Neutral
B‐ Aimtec LED drivers have been designed to function with a wide
range of available Triac devices, however the following list of Triac
devices have been tested.
1) Company: LUTRON
Series: SKYLARK
Model: SF‐10P‐WH (input voltage: 120Vac)
Model: SF‐12P‐277‐WH (input voltage 277Vac)
2) Company LUTRON
Series: DIVA
Model: DVF‐103P‐WH (input voltage: 120Vac)
Model: DVF‐103P‐277‐WH (input voltage: 277Vac)
3) Company BERKER
Model: 2867 10 (input voltage:230Vac)
If the power voltage range is 90~135Vac, triac suggested use model
SF‐10P‐WH or DVF‐103P‐WH.
If the power voltage range is 180~260Vac, triac suggested use
model SF‐12P‐277‐WH or DVF‐103P‐277‐WH.
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
Triac Dimming Performance
AMEPR15D-2470AZ
(mA)
Dimming Performance(Input 110Vac)
800
700
621
600
675
NS‐1223B
LUTRON DVCL‐
15SP‐WH
558
500
387
400
300
307
200
100
60
100
80
0
20
40
60
(mA)
80
100
120
140
160
Angle
Dimming Performance(Input 230 Vac)
800
701
700
626 607
600
572
NS‐1223C
664
Berker 286710
500
LUTRON LLSI‐
502B‐FAW‐M
386
400
311
300
267
200
98
100
49
0
20
102 116
2
70
120
170
220
Angle
Triac dimming performance is typical as with other models, for specific details on other model
performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages