ams AS3935 Embedded man-made disturber rejection algorithm Datasheet

high
performance
needs great
design.
Datasheet: AS3935 Franklin Lightning Sensor IC
Please be patient while we update our brand image as
austriamicrosystems and TAOS are now ams.
www.ams.com
Datashee t
AS3935
Franklin Lightning Sensor IC
1 General Description
Distance estimation to the head of the storm down to 1km in 14
The AS3935 is a programmable fully integrated Lightning Sensor IC
that detects the presence and approach of potentially hazardous
lightning activity in the vicinity and provides an estimation on the
distance to the head of the storm. The embedded lightning algorithm
checks the incoming signal pattern to reject the potential man-made
disturbers.
Detects both cloud-to-ground and intra-cloud (cloud-to-cloud)
The AS3935 can also provide information on the noise level and
inform the external unit (e.g. microcontroller) in case of high noise
conditions, with the noise floor generator and noise floor evaluation
blocks.
SPI and I²C interface is used for control and register reading
steps
flashes
Embedded man-made disturber rejection algorithm
Programmable detection levels enable threshold setting for
optimal controls
Antenna Tuning to compensate variations of the external
components
Supply voltage range 2.4V to 5.5V
The AS3935 can be programmed via a 4-wire standard SPI or an
I²C. Also, in case the latter is chosen, it is possible to choose among
four different addresses. Two clocks are internally generated by two
different RC-Oscillators: TRCO and SRCO. An automatic procedure
can increase the precision of those oscillators. The AS3935 can be
either supplied by an internal voltage regulator or directly by VDD.
Power-down, listening, and active mode
Package: 16LD MLPQ (4x4mm)
3 Applications
AS3935 is ideal for Weather Stations, Clocks, Sports Equipment,
Portables, Pool Safety, Uninterruptible Power Supply (UPS), Global
Positioning System (GPS), Cellular phones, Watches, and Golf
Equipment.
2 Key Features
Lightning sensor warns of lightning storm activity within a radius
of 40km
Figure 1. AS3935 Block Diagram
CS
I2CL/
I2CD/
SCL MISO MOSI
SINT
SPI
I2C
ADD0 ADD1
VDD VREG
I2C_ADD
Voltage
Regulator
EN_VREG
ACG
Register
Noise Floor
Level
Generation
POR
INP
Noise Floor
Evaluation
TEST
AFE
INN
LC-Oscillator
Watchdog
AS3935
Calibration
TRCO
SRCO
Bias
Block
Clock Generators
Signal Validation
IRQ
Energy Calculation
Statistical Distance Estimation
Lightning Algorithm
GND
www.austriamicrosystems.com
Revision 1.2
1 - 27
AS3935
Datasheet - C o n t e n t s
Contents
1 General Description ..................................................................................................................................................................
1
2 Key Features.............................................................................................................................................................................
1
3 Applications...............................................................................................................................................................................
1
4 Pin Assignments .......................................................................................................................................................................
3
4.1 Pin Descriptions....................................................................................................................................................................................
3
5 Absolute Maximum Ratings ......................................................................................................................................................
4
6 Electrical Characteristics...........................................................................................................................................................
5
6.1 Operating Conditions............................................................................................................................................................................
5
6.2 DC/AC Characteristics for Digital Inputs and Outputs ..........................................................................................................................
5
6.3 Detailed System and Block Specification .............................................................................................................................................
5
7 Typical Operating Characteristics .............................................................................................................................................
7
8 Detailed Description..................................................................................................................................................................
8
8.1 Circuit .................................................................................................................................................................................................
11
8.2 Operating Modes ................................................................................................................................................................................
11
8.3 System and Block Specification .........................................................................................................................................................
11
8.3.1 Register Table ........................................................................................................................................................................... 11
8.3.2 Register Table Description and Default Value........................................................................................................................... 12
8.4 Serial Peripheral Interface (SPI).........................................................................................................................................................
8.4.1
8.4.2
8.4.3
8.4.4
SPI Command Structure............................................................................................................................................................
Writing of Register Data.............................................................................................................................................................
Reading of Data from Addressable Registers (READ Mode) ....................................................................................................
Send Direct Command Byte ......................................................................................................................................................
8.5 I²C.......................................................................................................................................................................................................
14
14
15
15
16
16
8.5.1 I²C Byte Write ............................................................................................................................................................................ 17
8.5.2 I²C Register Read ...................................................................................................................................................................... 18
8.5.3 Direct Command........................................................................................................................................................................ 18
8.6 Voltage Regulator ...............................................................................................................................................................................
18
8.7 Analog Front-end (AFE) and Watchdog .............................................................................................................................................
19
8.8 Noise Floor Generator and Evaluation ...............................................................................................................................................
20
8.9 Lightning Algorithm ............................................................................................................................................................................
20
8.9.1
8.9.2
8.9.3
8.9.4
Signal Validation ........................................................................................................................................................................
Energy Calculation.....................................................................................................................................................................
Statistical Distance Estimation...................................................................................................................................................
Interrupt Management ...............................................................................................................................................................
20
21
21
22
8.10 Antenna Tuning ................................................................................................................................................................................
23
8.11 Clock Generation ..............................................................................................................................................................................
23
9 Package Drawings and Markings ...........................................................................................................................................
24
10 Ordering Information.............................................................................................................................................................
26
www.austriamicrosystems.com
Revision 1.2
2 - 27
AS3935
Datasheet - P i n A s s i g n m e n t s
4 Pin Assignments
INP
3
GND
4
ADD0
NC
I2CD / MOSI
13
AS3935
Exposed pad
5
6
7
8
CS
2
14
EN_VREG
INN
15
VREG
1
16
VDD
ACG
ADD1
Figure 2. Pin Assignments (Top View)
12
MISO
11
I2CL / SCL
10
IRQ
9
SI
4.1 Pin Descriptions
Table 1. Pin Descriptions
Pin Number
Pin Name
1
ACG
2
INN
3
INP
Antenna positive input
4
GND
Ground
5
VDD
6
VREG
Positive supply voltage / Regulated voltage
7
EN_VREG
Voltage Regulator Enable
8
CS
9
SI
10
IRQ
Digital output
Interrupt
11
I2CL/SCL
Digital input
I²C clock bus or SPI clock bus
(according to SI setting)
12
MISO
Digital output
SPI data output bus
13
I2CD/MOSI
Digital I/O with pull-up / Digital input
I²C data bus or SPI data input bus
(according to SI setting)
14
NC
15
ADD0
16
ADD1
Exposed pad
www.austriamicrosystems.com
Pin Type
Description
AC-Ground
Analog I/O
Supply pad
Digital input
Antenna ground
Positive supply voltage
Chip Select (active low)
Select Interface (GND → SPI or VDD → I²C)
Not connected
Digital input
Supply pad
Revision 1.2
I²C address selection LSB
I²C address selection MSB
Connect to Ground via the GND plan and pin 4
3 - 27
AS3935
Datasheet - A b s o l u t e M a x i m u m R a t i n g s
5 Absolute Maximum Ratings
Stresses beyond those listed in Table 2 may cause permanent damage to the device. These are stress ratings only, and functional operation of
the device at these or any other conditions beyond those indicated in Electrical Characteristics on page 5 is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Min
Max
Units
Comments
DC supply voltage (VDD)
-0.5
7
V
Input pin voltage (VIN)
-0.5
5
V
Input current (latch up immunity), (Iscr)
-100
100
mA
Norm: Jedec 78
kV
Norm: MIL 883 E method
3015 (Human Body Model)
Electrical Parameters
Electrostatic Discharge
Electrostatic discharge (ESD)
±2
Continuous Power Dissipation
Total power dissipation
(all supplies and outputs), (Pt)
0.1
mW
150
ºC
Temperature Ranges and Storage Conditions
Storage temperature (Tstrg)
-65
Package body temperature (Tbody)
Humidity non-condensing
Moisture Sensitivity Level (MSL)
www.austriamicrosystems.com
5
260
ºC
85
%
3
Norm: IPC/JEDEC J-STD-020
The reflow peak soldering temperature (body
temperature) is specified according IPC/JEDEC JSTD-020 “Moisture/Reflow Sensitivity Classification for
Non-hermetic Solid State Surface Mount Devices”.
Represents a maximum floor life time of 168h
Revision 1.2
4 - 27
AS3935
Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s
6 Electrical Characteristics
6.1 Operating Conditions
In this specification, all the defined tolerances for external components need to be assured over the whole operation conditions range and also
over lifetime.
Table 3. Operating Conditions
Symbol
Parameter
VDD
Positive supply voltage
TAMB
Ambient temperature
Conditions
Min
In case the voltage regulator is ON
In case the voltage regulator is OFF
Typ
Max
Units
2.4
5.5
V
2.4
3.6
V
-40
85
ºC
6.2 DC/AC Characteristics for Digital Inputs and Outputs
Table 4. CMOS Input
Symbol
Parameter
VIH
VIL
Conditions
Min
Typ
Max
Units
High level input voltage
0.6*VDD
0.7*VDD
0.9*VDD
V
Low level input voltage
0.125*VDD
0.2*VDD
0.3*VDD
V
Note: On ALL outputs, use the cells with the smallest drive capability which will do the job, in order to prevent current/spikes problems.
Table 5. CMOS Output
Symbol
Parameter
VOH
High level output voltage
VOL
Low level output voltage
CL
Capacitive load
Conditions
Min
Typ
Max
VDD-0.4
With a load current of 1mA
Units
V
For a clock frequency of 1MHz
VSS+0.4
V
400
pF
Max
Units
Table 6. Tristate CMOS Output
Symbol
Parameter
VOH
High level output voltage
VOL
Low level output voltage
IOZ
Tristate leakage current
Conditions
Min
Typ
VDD-0.4
With a load current of 1mA
To VDD and VSS
V
VSS+0.4
V
400
nA
6.3 Detailed System and Block Specification
Table 7. Electrical System Specifications
Symbol
Parameter
Min
Typ
Max
Units
Note
Input Characteristic
Input AC impedance
200
IPWDROFF
Power-down current when VREG is OFF
1
2
µA
IPWDRON
Power-down current when VREG is ON
8
15
µA
ILSMROFF
Current consumption in listening mode
when VREG is OFF
60
80
µA
ILSMRON
Current consumption in listening mode
when VREG is ON
70
µA
ISVM
Current Consumption in signal
verification mode
350
µA
RIN
kΩ
Current Consumption
www.austriamicrosystems.com
Revision 1.2
5 - 27
AS3935
Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s
Table 7. Electrical System Specifications
Symbol
Parameter
LCOSUT
LCO Start-up Time
TSRCO
SRCO frequency after calibration
1.065
TTRCO
TRCO frequency after calibration
30.5
TRCOCAL
Calibration time for the RC oscillators
VROUT
Voltage regulator output voltage
www.austriamicrosystems.com
Min
2.7
Typ
Max
Units
Note
2
ms
Time needed by the LCO to startup
1.125
1.19
MHz
32.26
34.0
kHz
2
ms
3.3
V
3.0
Revision 1.2
Assuming FLCO = 500 kHz
The calibration of the RC
oscillators starts after the LCO
settles
6 - 27
AS3935
Datasheet - Ty p i c a l O p e r a t i n g C h a r a c t e r i s t i c s
7 Typical Operating Characteristics
Figure 3. Power-down current if Voltage Regulator is OFF over
Supply Voltage (VREG)
Figure 4. Power-down Current if Voltage Regulator is OFF @3V
over Temperature
Figure 5. Current Consumption in Listening Mode if Voltage
Regulator is OFF over Supply Voltage (VREG)
Figure 6. Current Consumption in Listening Mode if Voltage
Regulator is OFF over Temperature (@ VREG=3V)
Figure 7. Output Regulated Voltage (VREG) @VDD=5V over
Temperature
Figure 8. Output Regulated Voltage (VREG) @ Room
Temperature over Supply Voltage
www.austriamicrosystems.com
Revision 1.2
7 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8 Detailed Description
The AS3935 can detect the presence of an approaching storm with lightning activities and provide an estimation of the distance to the leading
edge of the storm, where the leading edge of the storm is defined as the minimum distance from the sensor to the closest edge of the storm. The
embedded hardwired distance estimation algorithm of the AS3935 issues an interrupt on the IRQ pin (see Interrupt Management on page 22)
every time a lightning is detected. The estimated distance which is displayed in the distance estimation register does not represent the distance
to the single lightning but the estimated distance to the leading edge of the storm. A graphical representation is shown in the Figure 9.
Estimated Distance [km]
Figure 9. Storm
Time
Single lightning events
Distance estimation of the AS3935
As shown in Figure 10, Figure 11, Figure 12, and Figure 13, the system integration consists mainly of the AS3935 and an external control unit
(e.g. MCU) for the IC initialization and interrupt management (IRQ).
The choice of interface type (SPI vs. I²C) is accomplished using pin 9, SI (Select Interface). When the SI is connected to GND, the SPI is
selected. When the SI is connected to VDD, the I²C is selected. Pins ADD0 and ADD1 are used to select among 4 different I²C address.
The internal voltage regulator can be enabled by connecting EN_VREG to VDD. If the internal regulator is not used, capacitor C3 is not needed
and VREG must be connected to VDD. In this case, the AS3935 can be directly supplied by VREG and VDD (EN_VREG to GND).
AS3935 needs the following external components:
Power supply capacitor – CBAT – 1µF
Load capacitor on the ACG and VREG pins; the latter is needed only in case the voltage regulator is enabled
One, RLC resonators for the antenna
One resistor on the I2CL pin to VDD, if I²C is active
www.austriamicrosystems.com
(R2 > 10kΩ)
Revision 1.2
8 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
Figure 10. AS3935 Application Diagram (Voltage Regulator OFF, SPI Active)
EN_VREG
VREG
I2CL/SCL
ACG
I2CD/MOSI
ADD1
ADD0
INP
L1
C1
R1
CS
AS3935
C2
10µF
VDD
Control Unit
(MCU)
CBAT
2.4V - 3.6V
MISO
SI
IRQ
INN
GND
TEST
Figure 11. AS3935 Application Diagram (Voltage Regulator OFF, I²C Active)
CBAT
2.4V - 3.6V
EN_VREG
VREG
I2CL/SCL
ACG
I2CD/MOSI
ADD1
ADD0
INP
L1
C1
R1
MISO
SI
To VDD
IRQ
INN
GND
www.austriamicrosystems.com
CS
Control Unit
(MCU)
VDD
AS3935
C2
10µF
VDD or GND,
according to
I2C address
R2
TEST
Revision 1.2
9 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
Figure 12. AS3935 Application Diagram (Voltage Regulator ON, SPI Active)
C2
10µF
EN_VREG
VREG
I2CL/SCL
ACG
I2CD/MOSI
ADD1
ADD0
INP
L1
C1
R1
CS
AS3935
C3
1µF
VDD
Control Unit
(MCU)
CBAT
2.4V – 5.5V
MISO
SI
IRQ
INN
GND
TEST
Figure 13. AS3935 Application Diagram (Voltage Regulator ON, I²C Active)
CBAT
2.4V – 5.5V
EN_VREG
VREG
I2CL/SCL
ACG
I2CD/MOSI
ADD1
ADD0
INP
L1
C1
R1
MISO
SI
To VDD
IRQ
INN
GND
www.austriamicrosystems.com
CS
Control Unit
(MCU)
C2
10µF
VDD
AS3935
C3
1µF
VDD or GND,
according to
I2C address
R2
TEST
Revision 1.2
10 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.1 Circuit
Figure 1 shows a block diagram of the AS3935. The external antenna is directly connected to the Analog Front-end (AFE), which amplifies and
demodulates the received signal. The watchdog continuously monitors the output of the AFE and alerts the integrated lightning algorithm block in
the event of an incoming signal. The lightning algorithm block validates the signal by checking the incoming signal pattern, calculates the energy
and then the AS3935 provides the MCU with an estimate of the distance to the head of the storm. The lightning algorithm block, processing the
demodulated signal, can distinguish between lightning signal and man-made disturbers. If the received signal is classified as a man-made
disturber, then the event is rejected and the system automatically goes back into listening mode to minimize current consumption. If the incoming
signal identifies a lightning event, then the statistical distance estimation block performs an estimation of the distance to the head of the storm
(Typical time needed 2ms).
The LC oscillator together with the calibration block can calibrate both the TRCO and the SRCO clock generator to compensate process
variations.
8.2 Operating Modes
Power-down Mode.
In Power-down Mode, the entire AS3935 is switched off to reduce the current consumption to minimum (typ 1µA).
Listening Mode.
In listening mode the AFE, the watchdog, the noise floor level generation, the bias block, the TRCO, and the voltage regulator (in case it is
enabled) are running. In this mode the system can push down the power consumption to a minimum (typ 60µA). In case the maximum voltage
supply does not exceed 3.6V, it is possible to switch off the voltage regulator to save power.
Signal Verification.
The AS3935 enters in this mode every time the watchdog detects dynamic activity picked up by the antenna. Threshold can be set in WDTH
REG0x01[3:0]. The IC will leave this mode either if the incoming signal is classified as disturber or if the analysis of the single event (lightning) is
finished. If the received signal is classified as a disturber, then the AS3935 will automatically go back to listening mode without any needed
action from outside and an interrupt will be generated (with option bit this interrupt can be masked). If the received pattern matches all
requirements, the energy calculation is performed and the AS3935 provides distance estimation.
8.3 System and Block Specification
8.3.1
Register Table
Table 8. Register Table
Register #
7
6
0x00
4
Reserved
0x01
Reserved
0x02
Reserved
0x03
5
CL_STAT
LCO_FDIV
MIN_NUM_LIGH
MASK_DIST
SREJ
Reserved
S_LIG_M
INT
Reserved
S_LIG_MM
Reserved
DISP_LCO
DISP_SRCO
0
WDTH
0x05
0x06
1
PWD
NF_LEV
S_LIG_L
0x08
2
AFE_GB
0x04
0x07
3
DISTANCE
DISP_TRCO
Reserved
TUN_CAP
0x09
...
...
...
Lightning Detection Look-up Table
...
0x32
www.austriamicrosystems.com
Revision 1.2
11 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.3.2
Register Table Description and Default Value
Table 9. Detailed Register Map
Default
Value
Description
0
reserved
10010
AFE Gain Boost
0
Power-down
010
Noise Floor Level
0001
Watchdog threshold
1
reserved
1
Clear statistics
00
Minimum number of lightning
[3:0]
0010
Spike rejection
LCO_FDIV
[7:6]
00
Frequency division ration for antenna tuning
MASK_DIST
[5]
0
Mask Disturber
Reserved
[4]
0
reserved
INT
[3:0]
R
0000
Interrupt (see Table 18)
0x04
S_LIG_L
[7:0]
R
00000000
Energy of the Single Lightning LSBYTE
0x05
S_LIG_M
[7:0]
R
00000000
Energy of the Single Lightning MSBYTE
Reserved
[7:5]
S_LIG_MM
[4:0]
Reserved
[7:6]
DISTANCE
[5:0]
DISP_LCO
[7]
DISP_SRCO
[6]
DISP_TRCO
[5]
TUN_CAP
[3:0]
0x09
LDLUT1
[7:0]
R/W
10101101
0x0A
LDLUT2
[7:0]
R/W
00000000
0x0B
LDLUT3
[7:0]
R/W
00100101
0x0C
LDLUT4
[7:0]
R/W
00000011
0x0D
LDLUT5
[7:0]
R/W
00000001
0x0E
LDLUT6
[7:0]
R/W
00100010
0x0F
LDLUT7
[7:0]
R/W
10000011
0x10
LDLUT8
[7:0]
R/W
00000001
0x11
LDLUT9
[7:0]
R/W
00011111
0x12
LDLUT10
[7:0]
R/W
01000011
0x13
LDLUT11
[7:0]
R/W
00000010
0x14
LDLUT12
[7:0]
R/W
00011011
0x15
LDLUT13
[7:0]
R/W
01100011
Address
0x00
0x01
0x02
0x03
0x06
0x07
0x08
Register Name
Bit
Reserved
[7:6]
AFE_GB
[5:1]
PWD
[0]
NF_LEV
[6:4]
WDTH
[3:0]
Reserved
[7]
CL_STAT
[6]
MIN_NUM_LIGH
[5:4]
SREJ
www.austriamicrosystems.com
Type
R/W
R/W
R/W
R/W
reserved
R
00000
Energy of the Single Lightning MMSBYTE
reserved
R
R/W
000000
Distance estimation
0
Display LCO on IRQ pin
0
Display SRCO on IRQ pin
0
Display TRCO on IRQ pin
0000
Internal Tuning Capacitors (from 0 to 120pF in steps of 8pf)
Revision 1.2
Lightning Detection Look-up table
12 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
Table 9. Detailed Register Map
Address
Register Name
Bit
Type
Default
Value
0x16
LDLUT14
[7:0]
R/W
00000011
0x17
LDLUT15
[7:0]
R/W
00011000
0x18
LDLUT16
[7:0]
R/W
00010100
0x19
LDLUT17
[7:0]
R/W
00000101
0x1A
LDLUT18
[7:0]
R/W
00010100
0x1B
LDLUT19
[7:0]
R/W
10011101
0x1C
LDLUT20
[7:0]
R/W
00000111
0x1D
LDLUT21
[7:0]
R/W
00010001
0x1E
LDLUT22
[7:0]
R/W
01101010
0x1F
LDLUT23
[7:0]
R/W
00001011
0x20
LDLUT24
[7:0]
R/W
00001110
0x21
LDLUT25
[7:0]
R/W
00011101
0x22
LDLUT26
[7:0]
R/W
00010001
0x23
LDLUT27
[7:0]
R/W
00001100
0x24
LDLUT28
[7:0]
R/W
10101011
0x25
LDLUT29
[7:0]
R/W
00011001
0x26
LDLUT30
[7:0]
R/W
00001010
0x27
LDLUT31
[7:0]
R/W
01111111
0x28
LDLUT32
[7:0]
R/W
00100110
0x29
LDLUT33
[7:0]
R/W
00001000
0x2A
LDLUT34
[7:0]
R/W
10111101
0x2B
LDLUT35
[7:0]
R/W
00111001
0x2C
LDLUT36
[7:0]
R/W
00000110
0x2D
LDLUT37
[7:0]
R/W
10011011
0x2E
LDLUT38
[7:0]
R/W
01010110
0x2F
LDLUT39
[7:0]
R/W
00000101
0x30
LDLUT40
[7:0]
R/W
11100111
0x31
LDLUT41
[7:0]
R/W
10000001
0x32
LDLUT42
[7:0]
R/W
00000001
www.austriamicrosystems.com
Revision 1.2
Description
Lightning Detection Look-up table
13 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.4 Serial Peripheral Interface (SPI)
This 4-wire standard SPI interface (Mode 1) can be used by the Microcontroller (µC) to program the AS3935. To enable the SPI as data
interface, the Select Interface (SI) has to be set to low (GND).
The maximum clock operation frequency of the SPI is 2MHz.
Note: The clock operation frequency of the SPI should NOT be identical to the resonance frequency of the antenna (500kHz), in order to
minimize the on board 500kHz noise.
Table 10. Serial Data Interface (SDI) Pins
Name
Signal
Signal Level
Description
CS
Digital Input
CMOS
Chip Select (Active Low)
MOSI
Digital Input
CMOS
Serial data input from the external unit to the AS3935
MISO
Digital Output
CMOS
Serial data output from the AS3935 to the external unit
SCLK
Digital Input
CMOS
Clock for serial data read and write
Note: MISO is set to tristate if CS is high. In this way more than one device can communicate on the same MISO bus.
8.4.1
SPI Command Structure
To activate this SPI, the CS has to be set to low. A SPI command consists of two bytes serial command and the data are sampled on the falling
edge of SCLK (CPHA=1). The next table shows command structure, from the MSB (B15) to LSB (B0). The command stream has to be sent to
the SPI from the MSB (B15) to the LSB (B0).
MODE
B15
Register Address / Direct Command
B14
B13
B12
B11
B10
B9
Register Data
B8
B7
B6
B5
B4
B3
B2
B1
B0
The first two bits (B15 and B14) define the operating mode. There are two modes available – Read and Write/Direct command.
Table 11. Bits B15, B14
B15
B14
Mode
0
0
WRITE / DIRECT COMMAND
0
1
READ
In case a write or read command happens, then the next 5 bits (B13 to B9) define the register address, which has to be written respectively read,
as shown in the table below. The direct command is performed with a write operation (see Send Direct Command Byte on page 16).
Table 12. Bits B13 to B9
B13
B12
B11
B10
B9
B8
Read / Write Register
0
0
0
0
0
0
0x00
0
0
0
0
0
1
0x01
0
0
0
0
1
0
0x02
0
0
0
0
1
1
0x03
0
0
0
1
0
0
0x04
0
0
0
1
0
1
0x05
0
0
0
1
1
0
0x06
0
0
0
1
1
1
0x07
…
…
…
…
…
…
…
…
…
…
…
…
…
…
1
1
0
0
0
1
0x31
1
1
0
0
1
0
0x32
www.austriamicrosystems.com
Revision 1.2
14 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.4.2
Writing of Register Data
Figure 14. SPI Page Write
CS
SCLK
MOSI
X 0 0
A A A A A A D D D D D D D D D D D D D D D D D D
5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6
Two leading
Zeros indicate
WRITE Mode
8.4.3
X
CS falling
edge signals
end of
WRITE Mode
Data is moved
to Address
<A5-A0 > + n
Data is moved
to Address
<A5-A0 > + (n-1)
Data is moved
to Address
<A5-A0 > + 1
Data is moved
to Address
<A5-A0 >
D D D D D D D D D D
1 0 7 6 5 4 3 2 1 0
Reading of Data from Addressable Registers (READ Mode)
Once the address has been sent via SPI, the data can be fed through the MISO pin out to the microcontroller.
A CS high toggling high-low-high has to be performed after finishing the read mode session, in order to indicate the end of the READ command
and prepare the Interface to the next command control Byte.
To transfer bytes from consecutive addresses, SPI master has to keep the CS signal low and the SCLK clock has to be active as long as data
need to be read.
Figure 15. SPI Read Byte
CS
SCLK
MOSI
X
0
1
MISO
A5
A4
A3
A2
A1
X
01 pattern
indicates
READ Mode
www.austriamicrosystems.com
SCLK rising
edge Data is
transferred from
µC
X
A0
D7
SCLK
falling edge
Data is
sampled
D6
SCLK rising
edge Data is
moved from
Address
<A5-A0>
Revision 1.2
D5
D4
SCLK falling
edge Data is
transferred to
µC
D3
D2
D1
D0
X
CS falling
edge signals
end of READ
Mode
15 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.4.4
Send Direct Command Byte
It is possible to send direct commands by writing 0x96 in the registers REG0x3C and REG0x3D, as shown in the table below:
Table 13. Registers 0x3C, 0x3D
Direct Command
Register
Description
PRESET_DEFAULT
0x3C
Sets all registers in default mode
CALIB_RCO
0x3D
Calibrates automatically the internal RC Oscillators
8.5 I²C
An I²C slave interface is implemented for read/write access to the internal registers and to send direct commands. To enable the I²C as interface,
the Select Interface pin has to be set to the positive voltage supply (SI=VDD). The I2CL is the clock bus, while the I2CD is the data bus. An
external pull-up resistor on the I2CL pin is needed.
The device addresses for the AS3935 in read or write mode are defined by:
0-0-0-0-0-a1-a0-0: write mode device address (DW)
0-0-0-0-0-a1-a0-1: read mode device address (DR)
Where a0 and a1 are defined by the pins 5 (ADD0) and 6 (ADD1).
Figure 16. I²C Timing Diagram
start
stop
sr
I2CD
TF
TLO
I2CL
TR
THD;STA
THI
TSU;DAT
TSU;STA
TSU;STO
TSP
Table 14. I²C Parameters
Symbol
Parameter
TSP
Spike intensity
THI
High Clock Time
TLO
Low Clock Time
Conditions
400 kHz Clock speed
Min
Typ
50
100
Max
Units
ns
330
ns
660
ns
TSU
I2CD has to change Tsetup before rising
edge I2CL
30
ns
THD
No hold time needed for I2CD relative to
rising edge of I2CL
-40
ns
THD;STA
Within start condition, after low going I2CD, I2CL has to stay constant for
specified hold time
300
ns
TSU;STO
After high going edge of I2CL, I2CD has to stay constant for the specified setup
time before STOP or repeated start condition is applied
100
ns
100
ns
TSU;STA
www.austriamicrosystems.com
Revision 1.2
16 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.5.1
I²C Byte Write
The transmission begins with a START condition (S), which consists of a high-to-low transition of the I2CD bus when I2CL is high. The START
condition is followed by the Device Write mode (DW), word address (WA: register address to write into) and the register data (reg_dat). Until the
stop condition (P) the word address is automatically incremented at any register data.
Figure 17. I²C Byte Write
S
DW
A
WA
A
reg_data
A P
Slave (AS3935) as receiver
Slave (AS3935) as transmitter
Figure 18. I²C Page Write
S
DW
A
WA
A
Slave (AS3935) as receiver
reg_data 1
A
reg_data
reg_data2
WA++
A
WA++
….
A
reg_data n
A P
WA++
Slave (AS3935) as transmitter
Symbol
Description
S
START condition after STOP
Sr
Repeated START
DW
Device Address for write
DR
Device Address for read
WA
Word address
A
Acknowledge
N
No acknowledge
P
STOP condition
WA++
Internal address increment
www.austriamicrosystems.com
Revision 1.2
17 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.5.2
I²C Register Read
To read data from the slave device, the master has to change the transfer direction. This can be done either with a repeated START condition
followed by the device-read address, or simply with a new transmission START followed by the device-read address, when the bus is in IDLE
state. The device-read address is always followed by the 1st register byte transmitted from the slave. In Read Mode, any number of subsequent
register bytes can be read from the slave. The word address is incremented internally.
Figure 19. I²C Page Read
S
DW
A
WA
Slave (AS3935) as receiver
Slave (AS3935) as transmitter
A Sr
DR
A
Data 1
WA++
A
WA++
Data 2
A
…...
A
Data n
N P
WA++
Random Read and Sequential Read are combined formats. The repeated START condition is used to change the direction after the data transfer
from the master.
The word address transfer is initiated with a START condition issued by the master while the bus is idle. The START condition is followed by the
device-write address and the word address.
In order to change the data direction, a repeated START condition is issued on the 1st CLK pulse after the ACKNOWLEDGE bit of the word
address transfer. After the reception of the device-read address, the slave becomes the transmitter. In this state, the slave transmits register data
located by the previous received word address vector. The master responds to the data byte with a NOT ACKNOWLEDGE, and issues a STOP
condition on the bus.
In contrast to the Random Read, in a sequential read the transferred register-data bytes are responded by an acknowledge from the master. The
number of data bytes transferred in one sequence is unlimited (consider the behavior of the word-address counter). To terminate the
transmission, the master has to send a NOT ACKNOWLEDGE following the last data byte and subsequently generate the STOP condition.
8.5.3
Direct Command
It is possible to send direct commands writing 0x96 in the registers REG0x3C and REG0x3D, as shown in the table below:
Direct Command
Register
PRESET_DEFAULT
0x3C
CALIB_RCO
0x3D
8.6 Voltage Regulator
The AS3935 can be either supplied by a voltage regulator or directly.
If the voltage regulator is used, an additional current consumption (around 5µA) will have to be considered. In this case the pin EN_VREG must
be connected to VDD and the AS3935 is supplied by the pin VDD, while the regulated voltage is at the pin VREG (output of the voltage
regulator). In order to fulfil the stability requirements of the voltage regulator a capacitance greater than 1µF on the pin VREG to ground is
needed. The nominal output regulated voltage is 3V.
If the voltage regulator is not used, the pin EN_VREG must be connected to ground and the pins VDD and VREG must be connected together to
the supply voltage (e.g. battery).
www.austriamicrosystems.com
Revision 1.2
18 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.7 Analog Front-end (AFE) and Watchdog
The AFE amplifies and demodulates the AC-signal picked up by the antenna. Since the AS3935 is a lightning sensor based on narrowband
receiving technique (center frequency of 500kHz and a bandwidth of about 33kHz), the AFE bandwidth is meant to be greater than the antenna
bandwidth. In this way, it is possible to consider that the gain within the antenna bandwidth as constant.
The gain of the AFE by default is optimized to operate indoor (e.g. inside a building). If the AS3935 operates outdoor, then the AFE gain setting
has to be set to a lower value, as shown in the Table 15. Indoor and Outdoor setting must be selected according to the type of the application.
Table 15. AFE Setting, Outdoor vs. Indoor
AFE Setting
REG0x00[5:1]
Indoor
10010
Outdoor
01110
The output signal of the AFE is monitored by the watchdog, which enables the signal validation (see Signal Verification on page 11) in case the
input signal crosses a certain threshold. The AS3935 is automatically set back to Listening Mode once the Signal Validation block has made an
assessment on the nature of the received signal (lighting or disturber). With register REG0x01[3:0] it is possible to change the level of this
threshold to increase the robustness to disturbers. If higher thresholds are used, the AS3935 would loose sensitivity for very far lightning events,
with an improvement of the man-made disturber rejection as benefit.
Figure 20 shows the degradation of the detection efficiency (sensitivity of lightning detection) over the distance for different threshold settings.
Figure 20. Detection Efficiencies vs. Distance for Different Settings for WDTH, if SREJ=0000
60%
Detection Efficiency [%]
WDTH
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
40%
20%
0.0
0
10
20
30
40
Radius [km]
www.austriamicrosystems.com
Revision 1.2
19 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.8 Noise Floor Generator and Evaluation
The output signal of the AFE is also used to generate the noise floor level. The noise floor is continuously compared to a reference voltage (noise
threshold). Whenever the noise floor level crosses the noise threshold, the AS3935 issues an interrupt (INT_NH) to inform the external unit (e.g.
MCU) that the AS3935 cannot operate properly due to the high input noise received by the antenna (e.g. blocker). It is possible to set the
threshold for the noise floor limit with the bits REG0x01[6:4], as defined in the table below.
Table 16. Settings for the Noise Floor Threshold
Continuous Input Noise Level
[µVrms] (outdoor)
Continuous Input Noise Level
[µVrms] (indoor)
REG0x01[6]
REG0x01[5]
REG0x01[4]
390
28
0
0
0
630
45
0
0
1
860
62
0
1
0
1100
78
0
1
1
1140
95
1
0
0
1570
112
1
0
1
1800
130
1
1
0
2000
146
1
1
1
INT_NH is displayed as long as the input noise level (blocker) is higher than the noise floor threshold. By default the setting REG0x01[6:4] =010
is used.
8.9 Lightning Algorithm
The lightning algorithm consists of hardwired logic. False events (man-made disturbers) which might trigger the AS3935 are rejected, while
lightning events initiate calculations to estimate the distance to the head of the storm.
The Lightning algorithm is broken up into three sub blocks:
1. Signal validation: Verification that the incoming signal can be classified as lightning.
2. Energy calculation: Calculation of the energy of the single event.
3. Statistical distance estimation: According to the number of stored events (lightning), a distance estimate is calculated.
If the signal validation fails (the incoming signal does not have the characteristics of lightning), the energy calculation and statistical distance
estimation do not happen and the event is classified as disturber.
8.9.1
Signal Validation
The watchdog enables the lightning algorithm block in the event any activities are detected at the antenna. As this happens the output signal of
the AFE is evaluated by the Signal Validation block, which checks the pattern of the received signal. The signal validation checks the shape of
the received signal. In particular, the AS3935 can reject the impulse signals, like spikes, picked up by the antenna. The AS3935 has the ability to
improve the spike rejection with the register REG0x02[3:0]. By default, register REG0x02[3:0] =0010. Larger values in REG0x02[3:0]
correspond to more robust disturber rejection, with a decrease of the detection efficiency, as shown in the Figure 21.
www.austriamicrosystems.com
Revision 1.2
20 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
Figure 21. Detection Efficiencies vs. Distance for Different Setting of SREJ, if WDTH=0001
60%
Detection Efficiency [%]
SREJ
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
40%
20%
0.0
0
10
20
30
40
Radius [km]
At the end of the signal verification, the AS3935 automatically returns to listening mode.
8.9.2
Energy Calculation
If the received signal is classified as lightning, the energy is calculated. The result of the energy calculation is then stored in the registers
REG0x06[4:0], REG0x05[7:0] and REG0x04[7:0]. This value is just a pure number and has no physical meaning.
8.9.3
Statistical Distance Estimation
The AS3935 generates an assessment of the estimated distance to the head of an approaching storm. This assessment is done based on
statistical calculation. The energy of the single event (lightning) provided by the Energy Calculation block is stored in an internal memory,
together with timing information, in the AS3935. The events stored in the memory are then correlated with a look-up table by the statistical
distance estimation block, which provides a final estimation of the distance to the head of the storm. The algorithm automatically deletes events,
which are older than a certain time. R7=0x01 means that the storm is right overhead, while R7=0x3F is displayed when the storm is out of range.
This algorithm is hardwired and not accessible from outside.
The estimated distance is directly represented in km in the register REG0x07[5:0] (binary encoded). The distance estimation can change also if
no new event triggers the AS3935, as older events can be purged.
Table 17. Distance Estimation
REG0x07[5:0]
Distance [km]
111111
Out of range
101000
40
100101
37
100010
34
www.austriamicrosystems.com
Revision 1.2
21 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
Table 17. Distance Estimation
REG0x07[5:0]
Distance [km]
011111
31
011011
27
011000
24
010100
20
010001
17
001110
14
001100
12
001010
10
001000
8
000110
6
000101
5
000001
Storm is Overhead
The calculated energy is stored in registers REG0x04[7:0], REG0x05[7:0] and REG0x06[4:0].
8.9.4
Interrupt Management
Whenever events happen, the AS3935 pulls the IRQ high and displays the interrupt in the REG0x03[3:0]. Table 18 shows the interrupt register.
Table 18. Interrupts
Interrupt Name
REG0x03[3:0]
Description
INT_NH
0001
Noise level too high
INT_D
0100
Disturber detected
INT_L
1000
Lightning interrupt
The INT_NH is issued if the received noise exceeds the maximum acceptable noise. INT_NH persists until the noise is again back to low.
In case the signal validation block assesses the received signal as disturber, the INT_D is displayed. It is possible to mask the disturber
interrupts INT_D with MASK_DIST (REG0x03[5] =1).
If the MASK_DIST option is enabled, the signal on the pin IRQ never goes high if a disturber is detected.
The interrupt bus IRQ is set back to low whenever the interrupt register is read out.
The AS3935 issues a lightning interrupt (INT_L) if a new event is detected. All new events are stored in the internal memory and build up a
lightning statistic used by the distance estimation algorithm. If the AS3935 issues an interrupt and the Interrupt register is REG0x03[3:0] =000
the distance estimation has changed due to purging of old events in the statistics, based on the lightning distance estimation algorithm.
Whenever an interrupt is issued, the external unit should wait 2ms before reading the Interrupt register.
In addition, it is possible to allow the AS3935 to issue lightning interrupts only if a minimum number of events (lightning) have been detected in
the last 15 minutes. The minimum number of lightning events can be set with register REG0x02[5:4].
Table 19. Minimum Number of Lightning Detection
Minimum Number of Lightning
REG0x02[5]
REG0x02[4]
1
0
0
5
0
1
9
1
0
16
1
1
When this feature is utilized, a minimum number of events must occur to trigger a valid lightning event. This eliminates false triggers by manmade disturbers that may pass the validation algorithm. It is possible to clear the statistics built up by the lightning distance estimation algorithm
block by just toggling the bit REG0x02[6] (high-low-high).
www.austriamicrosystems.com
Revision 1.2
22 - 27
AS3935
Datasheet - D e t a i l e d D e s c r i p t i o n
8.10 Antenna Tuning
The AS3935 uses a loop antenna based on a parallel LC resonator. The antenna has to be designed to have its resonance frequency at 500kHz
and a quality factor of around 15. With a register setting it is possible to display on the IRQ pin the resonance frequency of the antenna as a
digital signal with the register REG0x08[7] =1. The external unit can measure this frequency and tune the antenna adding or removing the
internal capacitors with the register REG0x08[3:0]. It is necessary to tune the antenna with an accuracy of ±3.5% to optimize the performance of
the signal validation and distance estimation. The resonance frequency is internally divided by a factor, which is programmable with the register
REG0x03[7:6]. Table 20 shows the division ratio.
Table 20. Frequency Division Ratio for the Antenna Tuning
Division Ratio
REG0x03[7]
REG0x03[6]
16
0
0
32
0
1
64
1
0
128
1
1
8.11 Clock Generation
The clock generation is based on two different RC oscillators: a system RCO (SRCO) and a timer RCO (TRCO). The SRCO will run at about
1.1MHz and provides the main clock for the whole digital part. The TRCO is a low power low frequency oscillator and runs at 32.768 kHz.
Frequency variations in these two oscillators, due to temperature change, are automatically compensated.
The output frequency of those oscillators can be displayed on the IRQ pin with register setting (REG0x08[5] =1 TRCO, while REG0x08[6] =1
SRCO). Due to process variations, the frequency of both oscillators can be different from the nominal frequency. Therefore, it is possible to
calibrate both with a direct command. The precision of the calibration will depend on the accuracy of the resonance frequency of the antenna. It
is recommended to first trim the receiver antenna before the calibration of both oscillators is done.
The result of calibration of the 3 oscillators is stored in a volatile memory and needs to be done every time after POR (e.g. battery change) but all
oscillators are internally compensated in temperature and voltage supply variations.
If the AS3935 is set in power-down mode, the TRCO needs to be recalibrated using the following procedure:
1.
2.
3.
4.
Send Direct command CALIB_RCO
Modify REG0x08[5] = 1
Wait 2ms
Modify REG0x08[5] = 0
www.austriamicrosystems.com
Revision 1.2
23 - 27
AS3935
Datasheet - P a c k a g e D r a w i n g s a n d M a r k i n g s
9 Package Drawings and Markings
The device is available in a 16LD MLPQ (4x4mm) package.
Figure 22. Drawings and Dimensions
AS3935 @
YYWWQZZ
Notes:
1.
2.
3.
4.
5.
Dimensions & tolerancing conform to ASME Y14.5M-1994.
All dimensions are in millimeters. Angles are in degrees.
Coplanarity applies to the exposed heat slug as well as the terminal.
Radius on terminal is optional.
N is the total number of terminals.
Symbol
A
A1
A3
L
b
D
E
e
D2
E2
aaa
bbb
ccc
ddd
eee
fff
N
Min
0.70
0
0.30
0.25
2.55
2.55
-
Nom
0.75
0.02
0.20 REF
0.40
0.30
4.00 BSC
4.00 BSC
0.65 BSC
2.70
2.70
0.15
0.10
0.10
0.05
0.08
0.10
16
Max
0.80
0.05
0.50
0.35
2.80
2.80
-
Marking: YYWWQZZ.
YY
WW
Q
ZZ
@
Year
Manufacturing Week
Plant identification letter
Traceability code
Sublot identifier
www.austriamicrosystems.com
Revision 1.2
24 - 27
AS3935
Datasheet - R e v i s i o n H i s t o r y
Revision History
Revision
Date
1.0
30 Apr, 2012
1.1
14 May, 2012
1.2
10 Jul, 2012
Owner
rlc
jpe / msc
Description
Initial release
Corrected error in marking code
Updated info for exposed pad in Table 1, current consumption in Table 7,
Section 8.1, Section 8.2, Figure 19, Section 8.7, dimensions info in Section 9.
Note: Typos may not be explicitly mentioned under revision history.
www.austriamicrosystems.com
Revision 1.2
25 - 27
AS3935
Datasheet - O r d e r i n g I n f o r m a t i o n
10 Ordering Information
Table 21. Ordering Information
Ordering Code
Package Type
Marking
Delivery Form
Quantity
AS3935-BQFT
MLPQ 4x4 16LD
AS3935
7 inches Tape & Reel
1000 pcs
Note: All products are RoHS compliant and austriamicrosystems green.
Buy our products or get free samples online at ICdirect: http://www.austriamicrosystems.com/ICdirect
Technical Support is available at http://www.austriamicrosystems.com/Technical-Support
For further information and requests, please contact us mailto: [email protected]
or find your local distributor at http://www.austriamicrosystems.com/distributor
www.austriamicrosystems.com
Revision 1.2
26 - 27
AS3935
Datasheet - C o p y r i g h t s
Copyrights
Copyright © 1997-2012, austriamicrosystems AG, Tobelbaderstrasse 30, 8141 Unterpremstaetten, Austria-Europe. Trademarks Registered ®.
All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of
the copyright owner.
All products and companies mentioned are trademarks or registered trademarks of their respective companies.
Disclaimer
Devices sold by austriamicrosystems AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale.
austriamicrosystems AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding
the freedom of the described devices from patent infringement. austriamicrosystems AG reserves the right to change specifications and prices at
any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with austriamicrosystems AG for
current information. This product is intended for use in normal commercial applications. Applications requiring extended temperature range,
unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are
specifically not recommended without additional processing by austriamicrosystems AG for each application. For shipments of less than 100
parts the manufacturing flow might show deviations from the standard production flow, such as test flow or test location.
The information furnished here by austriamicrosystems AG is believed to be correct and accurate. However, austriamicrosystems AG shall not
be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use,
interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing,
performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of
austriamicrosystems AG rendering of technical or other services.
This product is intended to be used as an early warning indicator for lightning related storms. It does not guarantee accuracy or predict exact
strike locations. By using the part, the user shall be aware that s/he cannot just rely on the indication in order to prevent accidents caused by
lightning strikes. austriamicrosystems explicitly states that the user must follow the generally known and recommended instructions on how to
behave in the event of lightning strikes. In no event shall austriamicrosystems or its suppliers be liable for any direct, indirect, incidental, special,
exemplary or consequential damages (including, but not limited to procurement of substitute goods or services, loss of use, data or profits, or
business interruption) arising out of user’s disregard to such warnings and instructions.
Contact Information
Headquarters
austriamicrosystems AG
Tobelbaderstrasse 30
A-8141 Unterpremstaetten, Austria
Tel: +43 (0) 3136 500 0
Fax: +43 (0) 3136 525 01
For Sales Offices, Distributors and Representatives, please visit:
http://www.austriamicrosystems.com/contact
www.austriamicrosystems.com
Revision 1.2
27 - 27
Similar pages