For more information, please visit the product page | For information on related products, view Dc Power Jacks date 11/18/2014 page 1 of 8 SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY 60 W power universal input (90~264 Vac) single regulated output from 12~48V over voltage and short circuit protections UL/cUL and TUV safety approvals level V efficiency custom designs available output voltage output current (Vdc) max (A) ETSA120500UD 12 ETSA190342UD 19 ETSA240270UD 24 ETSA480125UD 48 ripple and noise1 max (W) max (mVp-p) 5.0 60 150 V 3.42 60 190 V 2.70 60 240 V efficiency level 1.25 60 190 V 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors. N Notes: output power TI MODEL N U • • • • • • • ED FEATURES O PART NUMBER KEY D IS C ETSA120500UD X - XX - SZ - CXX Base Number Factory Reserved for Custom Configurations Designation example of 12 Vdc, 5 A AC Input Plug: D = IEC 320 C8 plug DC Plug type: see output plug options on page 7 Input Cable: “Blank” = No Cable C = North American input cable 2 = European input cable 3 = United Kingdom input cable 4 = Australian input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 2 of 8 INPUT parameter conditions/description min voltage typ 90 47 12 V model all other models inrush current leakage current no load power consumption 12 V model all other models OUTPUT conditions/description min line regulation PROTECTIONS conditions/description over voltage protection 24 V model 19, 48 V models short circuit protection output shut down and auto restart parameter min TI parameter N load regulation SAFETY & COMPLIANCE typ U parameter conditions/description min units 264 Vac 63 Hz ED frequency max 1.4 1.5 A A 0.25 mA 0.5 0.3 W W max units ±1 % ±5 % typ typ max units 36 32 Vdc Vdc max units 3,000 4,242 Vac Vdc input to output at 10 mA for 1 minute isolation resistance input to output at 500 V dc safety approvals UL/cUL (UL 60950-1), CE, EN 60950-1/IEC 60950-1 EMI/EMC FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; VCCI; EN 61204-3; EN 55022; EN 55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11) RoHS 2011/65/EU O N isolation voltage 100 MΩ ENVIRONMENTAL parameter min typ max units 0 40 °C storage temperature -10 70 °C operating humidity 20 80 % storage humidity 10 90 % D IS C operating temperature conditions/description cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 3 of 8 MECHANICAL conditions/description 4.567 x 1.969 x 1.220 (116 x 50 x 31 mm) min input plug IEC320 / C8 typ max units inch ED parameter dimensions MECHANICAL DRAWING N U units: mm tolerance: ±1mm 31±1 O N TI 50±1 D IS C 116±1 cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 4 of 8 DC CORD cord length U ED 50±10 MODEL NO. CABLE GAUGE CORD LENGTH ETSA120500UD 16 AWG 1,000 ±100 18 AWG 1,830 +150/-0 18 AWG 1,530 ±100 ETSA480125UD 18 AWG 1,830 +150/-0 N ETSA190342UD ETSA240270UD NORTH AMERICAN INPUT CABLE IS C O N units: mm TI AC CORD EUROPEAN INPUT CABLE D units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 5 of 8 AC CORD (CONTINUED) UNITED KINGDOM INPUT CABLE U ED units: mm AUSTRALIAN INPUT CABLE IS C units: mm O CHINA INPUT CABLE N TI N units: mm SOUTH KOREA INPUT CABLE D units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 6 of 8 AC CORD (CONTINUED) BRAZIL INPUT CABLE U ED units: mm SOUTH AFRICA INPUT CABLE D IS C units: mm O JAPAN INPUT CABLE N TI N units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 7 of 8 OUTPUT PLUG OPTIONS 14±0.5 ED ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 *Tip positive P1 P1R C Right Angle PXR Standard PXX B A O IS C B N B A C C A B C Unit 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm TI Locking DC Plug EIAJ Plugs P5/P5R N Standard PX B A B A C A U Standard DC Plug A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm EIAJ A B C P12/P12R EIAJ-1 2.35 0.7 P13/P13R EIAJ-2 4.0 1.7 P14/P14R EIAJ-3 4.75 1.7 C Right Angle PXXR D Stripped and Tinned 25±5 9±2 D DC PLUG TYPE PXX X X Plug Type: PXX = See above plug options ST = Stripped and Tinned Plug Angle: “blank” = Straight R = Right Angle *Contact CUI for additional plug options cui.com Plug Polarity: P = Center Positive N = Center Negative D Unit 9.5 NA mm 9.5 5.0 mm 9.5 5.0 mm For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/18/2014 │ page 8 of 8 REVISION HISTORY rev. description date 01/24/2010 initial release new template applied 1.02 P7/P7R B dimension updated, V-Infinity branding removed, safety and EMI/EMC data updated 08/21/2012 1.03 updated series/model numbers 11/20/2012 1.04 corrected dc cord lengths 1.05 added ac cord options ED 1.0 1.01 12/22/2011 01/16/2013 11/18/2014 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.