ETC2 DHS50A12 Dc-dc converters power module type Datasheet

Ordering information
DC-DC Converters Power Module type
DHS50A
DH
1
S
50
2
3
A
05
4
*Providing heat sink
as option
5
-O
6
1Series name
2Single output
3Output wattage
4A : DC60-160V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
MODEL
DHS50A05
DHS50A12
DHS50A15
MAX OUTPUT WATTAGE[W]
50.0
50.4
51.0
DHS50A24
50.4
DC OUTPUT
5V 10A
12V 4.2A
15V 3.4A
24V 2.1A
MODEL
DHS50A05
DHS50A12
DHS50A15
DHS50A24
VOLTAGE[V]
DC60 - 160
SPECIFICATIONS
INPUT
DHS
CURRENT[A]
*1
0.55A
0.55A
0.55A
0.55A
EFFICIENCY[%]
*1
84.0typ
86.0typ
86.0typ
86.0typ
VOLTAGE[V]
5
12
15
24
CURRENT[A]
10
4.2
3.4
2.1
LINE REGULATION[mV]
10max
24max
30max
48max
LOAD REGULATION[mV]
10max
24max
30max
48max
0 to +100C*2 80max
120max
120max
120max
-40 to 0C *2 120max
150max
150max
150max
0 to 15% Load*2 160max
240max
240max
240max
0 to +100C*2 120max
150max
150max
150max
-40 to 0C *2 200max
200max
200max
250max
0 to 15% Load*2 240max
300max
300max
300max
0 to +65C 50max
120max
150max
240max
-40 to +100C 100max
240max
300max
480max
40max
60max
90max
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
20max
200max (DCIN 110V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
Fixed (TRM pin open), adjustable by external VR or external voltage
4.50 - 6.00
10.80 - 13.20
13.50 - 16.50
21.60 - 26.40
4.97 - 5.13
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
17.25 - 21.75
27.60 - 34.80
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 6.30 - 7.60
13.90 - 17.55
CIRCUIT AND
REMOTE
SENSING
nothing
OTHERS
REMOTE ON/OFF
Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
AGENCY APPROVALS
UL60950-1, C-UL (CSA60950-1), EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC110V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-2
DHS50A
External view
Recomending size for processing PCB
(TOP VIEW)
Base Plate(Aluminum)
Lot No.
2-f3.5
[0.14]
12.7 ±0.5
[0.5]
4-f1.5
[0.06]
[1.47]
7.62 7.62 5.08 7.62
[0.3] [0.3] [0.2] [0.3]
[0.3]
[1.1]
37.3 max
RC
+VOUT
27.9 ±0.5
TRM
-VIN
[0.19]
-VOUT
[0.3]
2-f2 ±0.2
[0.08]
(4.7)
7.62 5.08 1.27
[0.3] [0.2] [0.05]
4-f1±0.1
[0.04]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
7.62 7.62
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
2-f2.5
[0.1]
48.3
[1.9]
+VIN
Name Plate
2-M3
Mounting Hole
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 60g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
DHS-3
DHS
Ordering information
DC-DC Converters Power Module type
DHS100A
DH
1
S
100
2
3
A
05
4
*Providing heat sink
as option
5
-O
6
1Series name
2Single output
3Output wattage
4A : DC60-160V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
MODEL
DHS100A05
DHS100A12
DHS100A15
MAX OUTPUT WATTAGE[W]
100.0
100.8
100.5
DHS100A24
100.8
DC OUTPUT
5V 20A
12V 8.4A
15V 6.7A
24V 4.2A
MODEL
DHS100A05
DHS100A12
DHS100A15
DHS100A24
VOLTAGE[V]
DC60 - 160
SPECIFICATIONS
INPUT
DHS
CURRENT[A]
*1
1.1A
1.1A
1.1A
1.1A
EFFICIENCY[%]
*1
85.0typ
88.0typ
88.0typ
88.0typ
VOLTAGE[V]
5
12
15
24
CURRENT[A]
20
8.4
6.7
4.2
LINE REGULATION[mV]
10max
24max
30max
48max
LOAD REGULATION[mV]
10max
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
24max
30max
48max
0 to +100C*2 80max
120max
120max
120max
-40 to 0C *2 120max
150max
150max
150max
0 to 15% Load*2 160max
240max
240max
240max
0 to +100C*2 120max
150max
150max
150max
-40 to 0C *2 200max
200max
200max
250max
0 to 15% Load*2 240max
300max
300max
300max
0 to +65C 50max
120max
150max
240max
-40 to +100C 100max
240max
300max
480max
40max
60max
90max
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
20max
200max (DCIN 110V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
Fixed (TRM pin open), adjustable by external VR or external voltage
4.50 - 6.00
10.80 - 13.20
13.50 - 16.50
21.60 - 26.40
4.97 - 5.13
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
17.25 - 21.75
27.60 - 34.80
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 6.30 - 7.60
13.90 - 17.55
CIRCUIT AND
REMOTE
SENSING
nothing
OTHERS
REMOTE ON/OFF
Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
AGENCY APPROVALS
UL60950-1, C-UL (CSA60950-1), EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC110V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-4
DHS100A
External view
Recomending size for processing PCB
(TOP VIEW)
Base Plate(Aluminum)
Lot No.
2-f3.5
[0.14]
12.7 ±0.5
[0.5]
4-f1.5
[0.06]
[1.47]
7.62 7.62 5.08 7.62
[0.3] [0.3] [0.2] [0.3]
[0.3]
[1.1]
37.3 max
RC
+VOUT
27.9 ±0.5
TRM
-VIN
[0.19]
-VOUT
[0.3]
2-f2 ±0.2
[0.08]
(4.7)
7.62 5.08 1.27
[0.3] [0.2] [0.05]
4-f1±0.1
[0.04]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
7.62 7.62
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
2-f2.5
[0.1]
48.3
[1.9]
+VIN
Name Plate
2-M3
Mounting Hole
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 60g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
DHS-5
DHS
Ordering information
DC-DC Converters Power Module type
DHS200A
DH
1
S
200
2
3
A
05
4
*Providing heat sink
as option
5
-O
6
1Series name
2Single output
3Output wattage
4A : DC60-160V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
MODEL
DHS200A05
DHS200A12
DHS200A15
MAX OUTPUT WATTAGE[W]
200.0
200.4
201.0
DHS200A24
201.6
DC OUTPUT
5V 40A
12V 16.7A
15V 13.4A
24V 8.4A
MODEL
DHS200A05
DHS200A12
DHS200A15
DHS200A24
VOLTAGE[V]
DC60 - 160
SPECIFICATIONS
INPUT
DHS
CURRENT[A]
*1
2.1A
2.1A
2.1A
2.1A
EFFICIENCY[%]
*1
87.0typ
88.0typ
88.0typ
88.0typ
VOLTAGE[V]
5
12
15
24
CURRENT[A]
40
16.7
13.4
8.4
LINE REGULATION[mV]
10max
24max
30max
48max
LOAD REGULATION[mV]
10max
24max
30max
48max
0 to +100C*2 80max
120max
120max
120max
-40 to 0C *2 120max
150max
150max
150max
0 to 15% Load*2 160max
240max
240max
240max
0 to +100C*2 120max
150max
150max
150max
-40 to 0C *2 200max
200max
200max
250max
0 to 15% Load*2 240max
300max
300max
300max
0 to +65C 50max
120max
150max
240max
-40 to +100C 100max
240max
300max
480max
40max
60max
90max
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
200max (DCIN 110V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND
REMOTE SENSING
OTHERS
REMOTE ON/OFF
ISOLATION
20max
Fixed (TRM pin open), adjustable by external VR or external voltage
3.00 - 6.00
7.20 - 13.20
9.00 - 16.50
14.40 - 26.40
4.97 - 5.13
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
17.25 - 20.25
27.60 - 32.40
Works over 105% of rating and recovers automatically
6.30 - 7.30
13.90 - 16.35
Provided
Provided (Neqative Logic L : ON, H :OFF)
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
AGENCY APPROVALS
UL60950-1, C-UL (CSA60950-1), EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X61mm [2.3X0.5X2.4 inches] (WXHXD) / 100g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC110V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-6
DHS200A
External view
Recomending size for processing PCB
(TOP VIEW)
12.7 ±0.5
[0.5]
Lot No.
6-f1.5
[0.06]
2-f2.5
[0.1]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
2-f2 ±0.2
[0.08]
7.62 5.08 5.08 7.62 7.62 5.08 5.08
[0.3] [0.2] [0.2] [0.3] [0.3] [0.2] [0.2]
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
6-f1 ±0.1
[0.04]
12.7
[0.5]
-S
12.7
[0.5]
RC
TRM
+S
+VIN
50.8 ±0.5
[2]
61 max
[2.4]
10.16 7.62 7.62 10.16
[0.4] [0.3] [0.3] [0.4]
-VOUT
-VIN
Name Plate
(5.1)
[0.2]
+VOUT
4-M3
Mounting Hole
50.8
[2.0]
Base Plate(Aluminum)
4-f3.5
[0.14]
48.3
[1.9]
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 100g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
DHS-7
DHS
Ordering information
DC-DC Converters Power Module type
DHS50B
DH
1
S
50
2
3
B
05
4
*Providing heat sink
as option
5
-O
6
1Series name
2Single output
3Output wattage
4B : DC200-400V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
MODEL
DHS50B03
DHS50B05
DHS50B12
DHS50B15
DHS50B24
MAX OUTPUT WATTAGE[W]
33.0
50.0
50.4
51.0
50.4
DHS50B28
50.4
DC OUTPUT
3.3V 10A
5V 10A
12V 4.2A
15V 3.4A
24V 2.1A
28V 1.8A
MODEL
DHS50B03
DHS50B05
DHS50B12
DHS50B15
DHS50B24
DHS50B28
VOLTAGE[V]
DC200 - 400
0.22A
SPECIFICATIONS
INPUT
DHS
CURRENT[A]
*1
0.15A
0.22A
0.22A
0.22A
0.22A
EFFICIENCY[%]
*1
77.0typ
80.0typ
83.0typ
83.0typ
83.0typ
82.0typ
VOLTAGE[V]
3.3
5
12
15
24
28
CURRENT[A]
10
10
4.2
3.4
2.1
1.8
LINE REGULATION[mV]
10max
10max
24max
30max
48max
56max
LOAD REGULATION[mV]
10max
10max
24max
30max
48max
56max
0 to +100C*2 80max
80max
120max
120max
120max
120max
-40 to 0C *2 120max
120max
150max
150max
150max
150max
0 to 15% Load*2 160max
160max
240max
240max
240max
240max
0 to +100C*2 120max
120max
150max
150max
150max
150max
-40 to 0C *2 200max
200max
200max
200max
250max
250max
0 to 15% Load*2 240max
240max
300max
300max
300max
300max
0 to +65C 35max
50max
120max
150max
240max
280max
100max
240max
300max
480max
560max
20max
40max
60max
90max
90max
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-40 to +100C 66max
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
200max (DCIN 280V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND
REMOTE SENSING
OTHERS
REMOTE ON/OFF
ISOLATION
16max
Fixed (TRM pin open), adjustable by external VR or external voltage
2.97 - 3.96
4.50 - 6.00
10.80 - 13.20
13.50 - 16.50
21.60 - 26.40
25.20 - 30.80
3.30 - 3.40
4.97 - 5.13
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
27.56 - 28.44
17.25 - 21.75
27.60 - 34.80
32.20 - 40.60
Works over 105% of rating and recovers automatically
4.20 - 5.70
6.30 - 7.60
13.90 - 17.55
None
Provided (Neqative Logic L : ON, H :OFF)
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC280V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-8
DHS50B
External view
Recomending size for processing PCB
(TOP VIEW)
Base Plate(Aluminum)
Lot No.
2-f3.5
[0.14]
12.7 ±0.5
[0.5]
4-f1.5
[0.06]
[1.47]
7.62 7.62 5.08 7.62
[0.3] [0.3] [0.2] [0.3]
[0.3]
[1.1]
37.3 max
RC
+VOUT
27.9 ±0.5
TRM
-VIN
[0.19]
-VOUT
[0.3]
2-f2 ±0.2
[0.08]
(4.7)
7.62 5.08 1.27
[0.3] [0.2] [0.05]
4-f1±0.1
[0.04]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
7.62 7.62
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
2-f2.5
[0.1]
48.3
[1.9]
+VIN
Name Plate
2-M3
Mounting Hole
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 60g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
DHS-9
DHS
Ordering information
DC-DC Converters Power Module type
DHS100B
DH
1
S
100
2
3
B
05
4
*Providing heat sink
as option
5
-O
6
1Series name
2Single output
3Output wattage
4B : DC200-400V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
MODEL
DHS100B03
DHS100B05
DHS100B12
DHS100B15
DHS100B24
MAX OUTPUT WATTAGE[W]
66.0
100.0
100.8
100.5
100.8
DHS100B28
100.8
DC OUTPUT
3.3V 20A
5V 20A
12V 8.4A
15V 6.7A
24V 4.2A
28V 3.6A
MODEL
DHS100B03
DHS100B05
DHS100B12
DHS100B15
DHS100B24
DHS100B28
VOLTAGE[V]
DC200 - 400
0.42A
SPECIFICATIONS
INPUT
DHS
CURRENT[A]
*1
0.30A
0.44A
0.42A
0.42A
0.42A
EFFICIENCY[%]
*1
79.0typ
82.0typ
85.0typ
86.0typ
86.0typ
86.0typ
VOLTAGE[V]
3.3
5
12
15
24
28
CURRENT[A]
20
20
8.4
6.7
4.2
3.6
LINE REGULATION[mV]
10max
10max
24max
30max
48max
56max
LOAD REGULATION[mV]
10max
10max
24max
30max
48max
56max
0 to +100C*2 80max
80max
120max
120max
120max
120max
-40 to 0C *2 120max
120max
150max
150max
150max
150max
0 to 15% Load*2 160max
160max
240max
240max
240max
240max
0 to +100C*2 120max
120max
150max
150max
150max
150max
-40 to 0C *2 200max
200max
200max
200max
250max
250max
0 to 15% Load*2 240max
240max
300max
300max
300max
300max
0 to +65C 35max
50max
120max
150max
240max
280max
100max
240max
300max
480max
560max
20max
40max
60max
90max
90max
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-40 to +100C 66max
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
200max (DCIN 280V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND
REMOTE SENSING
OTHERS
REMOTE ON/OFF
ISOLATION
16max
Fixed (TRM pin open), adjustable by external VR or external voltage
2.97 - 3.96
4.50 - 6.00
10.80 - 13.20
13.50 - 16.50
21.60 - 26.40
25.20 - 30.80
3.30 - 3.40
4.97 - 5.13
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
27.56 - 28.44
17.25 - 21.75
27.60 - 34.80
32.20 - 40.60
Works over 105% of rating and recovers automatically
4.20 - 5.70
6.30 - 7.60
13.90 - 17.55
None
Provided (Neqative Logic L : ON, H :OFF)
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC280V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-10
DHS100B
External view
Recomending size for processing PCB
(TOP VIEW)
Base Plate(Aluminum)
Lot No.
2-f3.5
[0.14]
12.7 ±0.5
[0.5]
4-f1.5
[0.06]
[1.47]
7.62 7.62 5.08 7.62
[0.3] [0.3] [0.2] [0.3]
[0.3]
[1.1]
37.3 max
RC
+VOUT
27.9 ±0.5
TRM
-VIN
[0.19]
-VOUT
[0.3]
2-f2 ±0.2
[0.08]
(4.7)
7.62 5.08 1.27
[0.3] [0.2] [0.05]
4-f1±0.1
[0.04]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
7.62 7.62
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
2-f2.5
[0.1]
48.3
[1.9]
+VIN
Name Plate
2-M3
Mounting Hole
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 60g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
DHS-11
DHS
Ordering information
DC-DC Converters Power Module type
DHS250B
DH
1
S
250
2
3
B
*Providing heat sink
as option
MODEL
05
4
5
-O
6
1Series name
2Single output
3Output wattage
4B : DC200-400V
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
DHS250B03 DHS250B05 DHS250B07 DHS250B12 DHS250B15 DHS250B24 DHS250B28 DHS250B48
MAX OUTPUT WATTAGE[W]
165.0
250.0
247.5
252.0
247.5
252.0
252.0
249.6
DC OUTPUT
3.3V 50A
5V 50A
7.5V 33A
12V 21A
15V 16.5A
24V 10.5A
28V 9.0A
48V 5.2A
SPECIFICATIONS
MODEL
DHS250B03 DHS250B05 DHS250B07 DHS250B12 DHS250B15 DHS250B24 DHS250B28 DHS250B48
VOLTAGE[V]
INPUT
DHS
*1
0.67A
1.0A
1.0A
1.0A
1.0A
1.0A
1.0A
1.0A
EFFICIENCY[%]
*1
88.0typ
90.0typ
88.0typ
88.0typ
88.0typ
88.0typ
88.0typ
89.0typ
VOLTAGE[V]
3.3
5
7.5
12
15
24
28
48
CURRENT[A]
50
50
33
21
16.5
10.5
9.0
5.2
LINE REGULATION[mV]
10max
10max
20max
24max
30max
48max
56max
96max
LOAD REGULATION[mV]
10max
10max
20max
24max
30max
48max
56max
96max
0 to +100C*2 80max
80max
100max
120max
120max
120max
120max
200max
-40 to 0C *2 120max
120max
130max
150max
150max
150max
150max
250max
0 to 15% Load*2 160max
160max
200max
240max
240max
240max
240max
400max
0 to +100C*2 120max
120max
130max
150max
150max
150max
150max
250max
-40 to 0C *2 200max
200max
200max
200max
200max
250max
250max
400max
0 to 15% Load*2 240max
240max
260max
300max
300max
300max
300max
500max
0 to +65C 35max
50max
70max
120max
150max
240max
280max
480max
100max
140max
240max
300max
480max
560max
960max
20max
30max
40max
60max
90max
90max
180max
RIPPLE[mVp-p]
OUTPUT
DC200 - 400
CURRENT[A]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-40 to +100C 66max
DRIFT[mV]
*3
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
16max
200max (DCIN 280V, Io=100%)
*4
OUTPUT VOLTAGE SETTING[V]
Fixed (TRM pin open), adjustable by external VR or external voltage
1.98 - 3.96
3.00 - 6.00
4.50 - 8.25
7.20 - 13.20
9.00 - 16.50
14.40 - 26.40
16.80 - 30.80
28.80 - 52.80
3.30 - 3.40
4.97 - 5.13
7.43 - 7.67
11.91 - 12.29
14.76 - 15.24
23.62 - 24.38
27.56 - 28.44
47.24 - 48.76
17.25 - 20.25
27.60 - 32.40
32.20 - 37.80
55.20 - 64.80
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 4.20 - 4.85
6.30 - 7.30
8.70 - 10.20
13.90 - 16.35
CIRCUIT AND
REMOTE
SENSING
Provided
OTHERS
REMOTE ON/OFF
Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
CASE SIZE/WEIGHT
58.4X12.7X61mm [2.3X0.5X2.4 inches](WXHXD) / 100g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
At rated input(DC280V) and rated load.
Ripple and ripple noise is measured by using measuring board. Refer to the manual.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the manual for input range.
DHS-12
DHS250B
External view
Recomending size for processing PCB
(TOP VIEW)
12.7 ±0.5
[0.5]
Lot No.
6-f1.5
[0.06]
2-f2.5
[0.1]
58.4 max
[2.3]
48.3 ±0.5
[1.9]
2-f2 ±0.2
[0.08]
7.62 5.08 5.08 7.62 7.62 5.08 5.08
[0.3] [0.2] [0.2] [0.3] [0.3] [0.2] [0.2]
(5.0)
[0.2]
5.0 ±0.5
[0.2]
Case(PBT)
6-f1 ±0.1
[0.04]
12.7
[0.5]
-S
12.7
[0.5]
RC
TRM
+S
+VIN
50.8 ±0.5
[2]
61 max
[2.4]
10.16 7.62 7.62 10.16
[0.4] [0.3] [0.3] [0.4]
-VOUT
-VIN
Name Plate
(5.1)
[0.2]
+VOUT
4-M3
Mounting Hole
50.8
[2.0]
Base Plate(Aluminum)
4-f3.5
[0.14]
48.3
[1.9]
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.2inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 100g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max