CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 PROGRAMMABLE 3-PLL CLOCK SYNTHESIZER / MULTIPLIER / DIVIDER FEATURES • • • • • • • • • • • • • • • • • • High Performance 2:6 PLL Based Clock Synthesizer / Multiplier / Divider User Programmable PLL Frequencies Easy In-Circuit Programming via SMBus Data Interface Wide PLL Divider Ratio Allows 0-PPM Output Clock Error Clock Inputs Accept a Crystal or a Single-Ended LVCMOS or a Differential Input Signal Accepts Crystal Frequencies from 8 MHz up to 54 MHz Accepts LVCMOS or Differential Input Frequencies up to 200 MHz Two Programmable Control Inputs [S0/S1] for User Defined Control Signals Six LVCMOS Outputs with Output Frequencies up to 300 MHz LVCMOS Outputs can be Programmed for Complementary Signals Free Selectable Output Frequency via Programmable Output Switching Matrix [6x6] Including 7-Bit Post-Divider for Each Output PLL Loop Filter Components Integrated Low Period Jitter (Typical 60 ps) Features Spread Spectrum Clocking (SSC) for Lowering System EMI Programmable Output Slew-Rate Control (SRC) for Lowering System EMI 3.3-V Device Power Supply Industrial Temperature Range –40°C to 85°C Development and Programming Kit for Easy PLL Design and Programming (TI Pro-Clock™) • • Packaged in 20-Pin TSSOP Factory Programmable for Customized Default Settings are Available. Contact TI Sales for More Details. APPLICATIONS • • • Wireless Base Stations Network Line Cards Datacom / Telecom TERMINAL ASSIGNMENT PW PACKAGE (TOP VIEW) S0/CLK_SEL S1 VCC GND CLK_IN0 CLK_IN1 VCC GND SDATA SCLOCK 1 2 3 4 TSSOP 20 5 Pitch 0,65 mm 6 6.6 x 6.6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 Y5 Y4 VCCOUT2 GND Y3 Y2 VCCOUT1 GND Y1 Y0 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Pro-Clock is a trademark of Texas Instruments. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2006–2007, Texas Instruments Incorporated CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. DESCRIPTION The CDC706 is one of the smallest and powerful PLL synthesizer / multiplier / divider available today. Despite its small physical outlines, the CDC706 is very flexible. It has the capability to produce an almost independent output frequency from a given input frequency. The input frequency can be derived from a LVCMOS, differential input clock, or a single crystal. The appropriate input waveform can be selected via the SMBus data interface controller. To achieve an independent output frequency the reference divider M and the feedback divider N for each PLL can be set to values from 1 up to 511 for the M-Divider and from 1 up to 4095 for the N-Divider. The PLL-VCO (voltage controlled oscillator) frequency than is routed to the free programmable output switching matrix to any of the six outputs. The switching matrix includes an additional 7-bit post-divider (1-to-127) and an inverting logic for each output. The deep M/N divider ratio allows the generation of zero ppm clocks from any reference input frequency (e.g., a 27-MHz). The CDC706 includes three PLLs of those one supports SSC (spread-spectrum clocking). PLL1, PLL2, and PLL3 are designed for frequencies up to 300 MHz and optimized for zero-ppm applications with wide divider factors. PLL2 also supports center-spread and down-spread spectrum clocking (SSC). This is a common technique to reduce electro-magnetic interference. Also, the slew-rate controllable (SRC) output edges minimize EMI noise. Based on the PLL frequency and the divider settings, the internal loop filter components will be automatically adjusted to achieve high stability and optimized jitter transfer characteristic of the PLL. The device provides customized applications. It is preprogrammed with a factory default configuration (see Figure 13) and can be reprogrammed to a different application configuration via the serial SMBus Interface. Two free programmable inputs, S0 and S1, can be used to control for each application the most demanding logic control settings (outputs disable to low, outputs 3-state, power down, PLL bypass, etc). The CDC706 has three power supply pins, VCC, VCCOUT1, and VCCOUT2. VCC is the power supply for the device. It operates from a single 3.3-V supply voltage. VCCOUT1 and VCCOUT2 are the power supply pins for the outputs. VCCOUT1 supplies the outputs Y0 and Y1 and VCCOUT2 supplies the outputs Y2, Y3, Y4, and Y5. Both outputs supplies can be 2.3 V to 3.6 V. At output voltages lower than 3.3 V, the output current drive is limited. The CDC706 is characterized for operation from –40°C to 85°C. 2 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 FUNCTIONAL BLOCK DIAGRAM VCC GND VCCOUT1 PLL Bypass PFD Filter prg. 12 Bit Divider N Crystal or Clock Input CLK_IN0 XO or 2 LVCMOS or Differential Input CLK_IN1 VCO VCO2 Bypass prg. 9 Bit Divider M prg. 12 Bit Divider N MUX PFD Filter VCO SSC On/Off 5 x 6 Programmable Switch A prg. 9 Bit Divider M PLL2 w/ SSC MUX SO/CLK_SEL VCO3 Bypass PROGRAMMING S1 LOGIC SDATA SMBUS LOGIC SCLOCK PLL3 prg. 9 Bit Divider M PFD Filter Factory Prg. prg. 12 Bit Divider N MUX VCO 6 x 6 Programmable Switch B PLL1 6 x Programmable 7-Bit Divider P0, P1, P2, P3, P4, P5, and Inversion Logic Output Switch Matrix VCO1 Bypass GND LV CMOS Y0 LV CMOS Y1 LV CMOS Y2 LV CMOS Y3 LV CMOS Y4 LV CMOS Y5 VCCOUT2 OUTPUT SWITCH MATRIX 5x6 − Switch A 7-Bit Divider 6x6 − Switch B P0 Y0 P1 Y1 P2 Y2 PLL 2 non SSC P3 Y3 PLL 2 w/ SSC P4 Y4 P5 Y5 Input CLK (PLL Bypass) PLL 1 PLL 3 Programming Submit Documentation Feedback 3 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 TERMINAL FUNCTIONS TERMINAL I/O DESCRIPTION NAME TSSOP20 NO. Y0 to Y5 11, 12, 15, 16, 19, 20 O LVCMOS outputs CLK_IN0 5 I Dependent on SMBus settings, CLK_IN0 is the crystal oscillator input and can also be used as LVCMOS input or as positive differential signal inputs. CLK_IN1 6 I/O Dependent on SMBus settings, CLK_IN1 is serving as the crystal oscillator output or can be the second LVCMOS input or the negative differential signal input. VCC 3, 7 Power 3.3-V power supply for the device. VCCOUT1 14 Power Power supply for outputs Y0, Y1. VCCOUT2 18 Power Power supply for outputs Y2, Y3, Y4, Y5. 4, 8, 13, 17 Ground Ground S0, CLK_SEL 1 I User programmable control input S0 (PLL bypass or power-down mode) , or CLK_SEL (selects one of two LVCMOS clock inputs), dependent on the SMBus settings; LVCMOS inputs; internal pullup 150 kΩ. S1 2 I User programmable control input S1 (output enable/disable or all output low), dependent on the SMBus settings; LVCMOS inputs; internal pullup 150 kΩ SDATA 9 I/O SCLOCK 10 I GND Serial control data input/output for SMBus controller; LVCMOS input Serial control clock input for SMBus controller; LVCMOS input ABSOLUTE MAXIMUM RATINGS over operating free-air temperature range (unless otherwise noted) (1) VALUE UNIT VCC Supply voltage range –0.5 to 4.6 V VI Input voltage range (2) –0.5 to VCC + 0.5 V VO Output voltage range (2) – 0.5 to VCC + 0.5 V II Input current (VI < 0, V I > VCC) ±20 mA IO Continuous output current ±50 mA Tstg Storage temperature range –65 to 150 °C TJ Maximum junction temperature 125 °C (1) (2) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute maximum rated conditions for extended periods may affect device reliability. The input and output negative voltage ratings may be exceeded if the input and output clamp-current ratings are observed. PACKAGE THERMAL RESISTANCE for TSSOP20 (PW) Package (1) (2) PARAMETER θJA Thermal resistance junction-to-ambient θJC Thermal resistance junction-to-case (1) (2) 4 AIRFLOW (LFM) °C/W 0 66.3 150 59.3 250 56.3 500 51.9 19.7 The package thermal impedance is calculated in accordance with JESD 51 and JEDEC2S2P (high-k board). For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI Web site at www.ti.com. Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 RECOMMENDED OPERATING CONDITIONS over operating free-air temperature range (unless otherwise noted) MIN NOM MAX 3 3.3 3.6 V 3.6 V 3.6 V 0.3 VCC V VCC Device supply voltage VCCOUT1 Output Y0, Y1 supply voltage 2.3 VCCOUT2 Output Y2, Y3, Y4, Y5 supply voltage 2.3 VIL Low level input voltage LVCMOS VIH High level input voltage LVCMOS VIthresh Input voltage threshold LVCMOS VI Input voltage range LVCMOS |VID| Differential input voltage 0.1 VIC Common-mode for differential input voltage 0.2 IOH/IOL Output current (3.3 V) IOH/IOL CL TA Operating free-air temperature UNIT 0.7 VCC V 0.5 VCC V 0 3.6 V V Vcc - 0.6 V ±6 mA Output current (2.5 V) ±4 mA Output load LVCMOS 25 pF 85 °C –40 RECOMMENDED CRYSTAL SPECIFICATIONS fXtal Crystal input frequency range (fundamental mode) ESR Effective series resistance (1) (2) CIN Input capacitance CLK_IN0 and CLK_IN1 (1) (2) MIN NOM MAX UNIT 8 27 54 MHz 15 Ω 60 3 pF For crystal frequencies above 50 MHz the effective series resistor should not exceed 50 Ω to assure stable start-up condition. Maximum Power Handling (Drive Level) see Figure 15. TIMING REQUIREMENTS over recommended ranges of supply voltage, load, and operating-free air temperature MIN NOM MAX PLL mode 1 200 PLL bypass mode 0 200 40% 60% UNIT CLK_IN REQUIREMENTS fCLK_IN CLK_IN clock input frequency (LVCMOS or Differential) tr / tf Rise and fall time CLK_IN signal (20% to 80%) dutyREF Duty cycle CLK_IN at VCC / 2 4 MHz ns SMBus TIMING REQUIREMENTS (see Figure 11) fSCLK SCLK frequency th(START) START hold time 100 tw(SCLL) SCLK low-pulse duration tw(SCLH) SCLK high-pulse duration tsu(START) START setup time 0.6 µs th(SDATA) SDATA hold time 0.3 µs tsu(SDATA) SDATA setup time 0.25 µs tr SCLK / SDATA input rise time 1000 tf SCLK / SDATA input fall time 300 tsu(STOP) STOP setup time tBUS Bus free time tPOR Time in which the device must be operational after power-on reset µs 4.7 µs 4 50 µs ns ns µs 4 µs 4.7 Submit Documentation Feedback kHz 4 500 ms 5 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 DEVICE CHARACTERISTICS over recommended operating free-air temperature range and test load (unless otherwise noted), see Figure 1 MIN TYP (1) MAX UNIT All PLLs on, all outputs on, fOUT = 80 MHz, fCLK_IN = 27 MHz, f(VCO) = 160 MHz 90 115 mA fIN = 0 MHz, VCC = 3.6 V 50 µA 2.1 V PARAMETER TEST CONDITIONS OVERALL PARAMETER (2) ICC Supply current ICCPD Power down current. Every circuit powered down except SMBus V(PUC) Supply voltage VCC threshold for power up control circuit f(VCO) VCO frequency of internal PLL (any of three PLLs) Normal speed-mode (3) All PLLs PLL2 with SSC High-speed mode (3) LVCMOS output frequency range (4), See Figure 4 fOUT 80 200 80 167 180 300 MHz VCC = 2.5 V 250 VCC = 3.3 V 300 VCC = 3 V, II = –18 mA –1.2 V ±5 µA 5 µA -10 µA MHz LVCMOS PARAMETER V(IK) LVCMOS input voltage II LVCMOS input current (CLK_IN0 and VI = 0 V or VCC, VCC = 3.6 V CLK_IN1) IIH LVCMOS input current (S1/S0) VI = VCC, VCC = 3.6 V IIL LVCMOS input current (S1/S0) VI = 0 V, VCC = 3.6 V CI Input capacitance at CLK_IN0 and CLK_IN1 VI = 0 V or VCC -35 3 pF LVCMOS PARAMETER FOR VCCOUT = 3.3-V Mode VOH LVCMOS high-level output voltage VCCOUT = 3 V, IOH = –0.1 mA 2.9 VCCOUT = 3 V, IOH = –4 mA 2.4 VCCOUT = 3 V, IOH = –6 mA 2.1 V VCCOUT = 3 V, IOL = 0.1 mA VOL LVCMOS low-level output voltage VCCOUT = 3 V, IOL = 4 mA 0.5 VCCOUT = 3 V, IOL = 6 mA 0.85 All PLL bypass 9 V tPLH, tPHL Propagation delay tr0/tf0 Rise and fall time for output slew rate 0 VCCOUT = 3.3 V (20%–80%) 1.7 3.3 4.8 ns tr1/tf1 Rise and fall time for output slew rate 1 VCCOUT = 3.3 V (20%–80%) 1.5 2.5 3.2 ns tr2/tf2 Rise and fall time for output slew rate 2 VCCOUT = 3.3 V (20%–80%) 1.2 1.6 2.1 ns tr3/tf3 Rise and fall time for output slew rate 3 (default configuration) VCCOUT = 3.3 V (20%–80%) 0.4 0.6 1 ns fOUT = 50 MHz 55 90 fOUT = 245.76 MHz 45 80 125 155 60 95 VCO bypass 1 PLL, 1 Output tjit(cc) Cycle-to-cycle jitter (5) (6) 3 PLLs, 3 Outputs (1) (2) (3) (4) (5) (6) 6 0.1 ns 11 fOUT = 50 MHz fOUT = 245.76 MHz ps All typical values are at respective nominal VCC. For calculating total supply current, add the current from Figure 2, Figure 3, and Figure 4. Using high-speed mode of the VCO reduces the current consumption. See Figure 3. Normal-speed mode or high-speed mode must be selected by the VCO frequency selection bit in Byte 6, Bit [7:5]. The min f(VCO) can be lower but impacts jitter-performance. Do not exceed the maximum power dissipation of the 20-pin TSSOP package (600 mW at no air flow). See Figure 5 50000 cycles. Jitter depends on configuration. Jitter data is normal tr/tf, input frequency = 3.84 MHz, f(VCO) = 245.76 MHz. Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 DEVICE CHARACTERISTICS (continued) over recommended operating free-air temperature range and test load (unless otherwise noted), see Figure 1 PARAMETER 1 PLL, 1 Output tjit(per) Peak-to-peak period jitter (5) (6) 3 PLLs, 3 Outputs tsk(o) Output skew (see (7) and Table 5) Output duty cycle (8) odc MIN TYP (1) MAX fOUT = 50 MHz 60 90 fOUT = 245.76 MHz 55 80 145 180 70 105 TEST CONDITIONS fOUT = 50 MHz fOUT = 245.76 MHz 1.6-ns rise/fall time at f(VCO) = 150 MHz, Pdiv = 3 200 f(VCO) = 100 MHz, Pdiv = 1 45% UNIT ps ps 55% LVCMOS PARAMETER FOR VCCOUT = 2.5-V Mode (9) VOH LVCMOS high-level output voltage VOL LVCMOS low-level output voltage VCCOUT = 2.3 V, IOH = 0.1 mA 2.2 VCCOUT = 2.3 V, IOH = –3 mA 1.7 VCCOUT = 2.3 V, IOH = –4 mA 1.5 V VCCOUT = 2.3 V, IOL = 0.1 mA 0.1 VCCOUT = 2.3 V, IOL = 3 mA 0.5 VCCOUT = 2.3 V, IOL = 4 mA V 0.85 All PLL bypass 9 tPLH, tPHL Propagation delay tr0/tf0 Rise and fall time for output slew rate 0 VCCOUT = 2.5 V (20%–80%) 2 3.9 5.6 ns tr1/tf1 Rise and fall time for output slew rate 1 VCCOUT = 2.5 V (20%–80%) 1.8 2.9 4.4 ns tr2/tf2 Rise and fall time for output slew rate 2 VCCOUT = 2.5 V (20%–80%) 1.3 2 3.2 ns tr3/tf3 Rise and fall time for output slew rate 3 (default configuration) VCCOUT = 2.5 V (20%–80%) 0.4 0.8 1.1 ns fOUT = 50 MHz 60 105 fOUT = 245.76 MHz 50 85 130 160 VCO Bypass 1 PLL, 1 Output tjit(cc) Cycle-to-cycle jitter (10) (11) 3 PLLs, 3 Outputs 1 PLL, 1 Output tjit(per) Peak-to-peak period jitter (10) (11) 3 PLLs, 3 Outputs tsk(o) odc Output skew (see (12) and Table 5) Output duty cycle (13) ns 11 fOUT = 50 MHz fOUT = 245.76 MHz 60 95 fOUT = 50 MHz 65 110 fOUT = 245.76 MHz 60 90 145 180 70 105 fOUT = 50 MHz fOUT = 245.76 MHz 2-ns rise/fall time at f(VCO) = 150 MHz, Pdiv = 3 f(VCO) = 100 MHz, Pdiv = 1 250 45% ps ps ps 55% SMBus PARAMETER VIK SCLK and SDATA input clamp voltage VCC = 3 V, II = –18 mA II SCLK and SDATA input current VI = 0 V or VCC, VCC = 3.6 V VIH SCLK input high voltage VIL SCLK input low voltage VOL SDATA low-level output voltage (7) (8) (9) (10) (11) (12) (13) –1.2 V ±5 µA 2.1 IOL = 4 mA, VCC = 3 V V 0.8 V 0.4 V The tsk(o) specification is only valid for equal loading of all outputs. odc depends on output rise and fall time (tr/tf). The data is for normal tr/tf and is valid for both SSC on and off. T here is a limited drive capability at output supply voltage of 2.5 V. For proper termination, see application report SCAA080. 50000 cycles. Jitter depends on configuration. Jitter data is normal tr/tf, input frequency = 3.84 MHz, f(VCO) = 245.76 MHz. The tsk(o) specification is only valid for equal loading of all outputs. odc depends on output rise and fall time (tr/tf). The data is for normal tr/tf and is valid for both SSC on and off. Submit Documentation Feedback 7 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 DEVICE CHARACTERISTICS (continued) over recommended operating free-air temperature range and test load (unless otherwise noted), see Figure 1 PARAMETER CI TEST CONDITIONS MIN TYP (1) MAX UNIT Input capacitance at SCLK VI = 0 V or VCC 3 10 pF Input capacitance at SDATA VI = 0 V or VCC 3 10 pF PARAMETER MEASUREMENT INFORMATION CDC706 1k Yn LVCMOS 1k 10 pF Figure 1. Test Load TYPICAL CHARACTERISTICS 120 110 VCC = 3.3 V, M div = 1, N div = 2, P div = 1, VCO normal-speed mode 100 90 ICC - [mA] 80 PLL 1 + PLL 2 + PLL3 70 PLL 1 + PLL 2 SSC + PLL3 60 PLL 1 + PLL 2 50 40 PLL 1 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 fVCO - [MHz] Figure 2. ICC vs Number of PLLs and VCO Frequency (VCO at Normal-Speed Mode, Byte 6 Bit [7:5]) 8 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 TYPICAL CHARACTERISTICS (continued) 120 VCC = 3.3 V, M div = 1, N div = 2, P div = 1, VCO high-speed mode 110 100 90 PLL 1 + PLL 2 + PLL3 ICC - [mA] 80 70 PLL 1 + PLL 2 SSC + PLL3 60 PLL 1 + PLL 2 50 40 PLL 1 30 20 10 0 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 fVCO - [MHz] Figure 3. ICC vs Number of PLLs and VCO Frequency (VCO at High-Speed Mode, Byte 6 Bit [7:5]) 90 85 80 VCC = 3.3 V, M div = 1, N div = 2, P div = 1 75 70 6 Outputs 65 60 5 Outputs ICC - [mA] 55 50 45 4 Outputs 40 35 3 Outputs 30 25 20 2 Outputs 15 10 5 1 Outputs 0 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 fVCO - [MHz] Figure 4. ICCOUT vs Number of Outputs and VCO Frequency Submit Documentation Feedback 9 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 TYPICAL CHARACTERISTICS (continued) 3.6 3.4 3.2 VCC = 3.3 V, M div = 4, N div = 15, P div = 1 3.0 2.8 2.6 VOH at VCCOUT = 3.6 V 2.4 VOUT - [V] 2.2 2.0 1.8 1.6 VOH at VCCOUT = 2.3 V 1.4 1.2 1.0 0.8 0.6 VOL at VCCOUT = 3.6 V VOL at VCCOUT = 2.3 V 0.4 0.2 0.0 80 100 120 140 160 180 200 220 240 260 280 300 320 fOUT - [MHz] Figure 5. Output Swing vs Output Frequency 10 Submit Documentation Feedback 340 360 380 400 420 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 APPLICATION INFORMATION SMBus Data Interface To enhance the flexibility and function of the clock synthesizer, a two-signal serial interface is provided. It follows the SMBus specification Version 2.0, which is based upon the principals of operation of I2C. More details of the SMBus specification can be found at http://www.smbus.org. Through the SMBus, various device functions, such as individual clock output buffers, can be individually enabled or disabled. The registers associated with the SMBus data interface initialize to their default setting upon power-up; therefore, using this interface is optional. The clock device register changes are normally made upon system initialization, if any are required. Data Protocol The clock driver serial protocol accepts Byte Write, Byte Read, Block Write, and Block Read operations from the controller. For Block Write/Read operations, the bytes must be accessed in sequential order from lowest to highest byte (most significant bit first) with the ability to stop after any complete byte has been transferred. For Byte Write and Byte Read operations, the system controller can access individually addressed bytes. Once a byte has been sent, it is written into the internal register and effective immediately with the rising edge of the ACK bit. This applies to each transferred byte, independent of whether this is a Byte Write or a Block Write sequence. The offset of the indexed byte is encoded in the command code, as described in Table 1. The Block Write and Block Read protocol is outlined in Figure 9 and Figure 10, while Figure 7 and Figure 8 outlines the corresponding Byte Write and Byte Read protocol. Slave Receiver Address (7 bits) A6 A5 A4 A3 A2 A1 A0 R/W 1 1 0 1 0 0 1 0 Table 1. Command Code Definition Bit 7 (6:0) Description 0 = Block Read or Block Write operation 1 = Byte Read or Byte Write operation Byte Offset for Byte Read and Byte Write operation. For Block Read and Block Write operation, these bits have to be 000 0000. Submit Documentation Feedback 11 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 1 S 7 Slave Address 1 1 Wr A S Start Condition Sr Reapeated Start Condition 8 Data Byte 1 1 A P Rd Read (Bit Value = 1) Wr Write (Bit Value = 0) A Acknowledge (ACK = 0 and NACK = 1) P Stop Condition PE Packet Error Master to Slave Transmission Slave to Master Transmission Figure 6. Generic Programming Sequence Byte Write Programming Sequence 1 7 1 S Slave Address Wr 1 8 A CommandCode 1 8 1 1 A Data Byte A P 7 1 1 Slave Address Rd A Figure 7. Byte Write Protocol Byte Read Programming Sequence 1 7 1 1 S Slave Address Wr A 8 Data Byte 8 1 CommandCode 1 1 A P 1 A S Figure 8. Byte Read Protocol Block Write Programming Sequence(1) 1 7 1 1 S Slave Address Wr A 8 Data Byte 0 1 8 CommandCode 8 A Data Byte 1 1 8 A Byte Count N 1 8 A ----- (1)Data Data Byte N–1 1 A 1 1 A P Byte 0 is reserved for revision code and vendor identification. However, this byte is used for internal test. Do not write into it other than 0000 0000. Figure 9. Block Write Protocol 12 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Block Read Programming Sequence 1 7 1 1 S Slave Address Wr A 8 1 CommandCode 8 1 8 Byte Count N A Data Byte 0 1 A Sr 7 1 1 Slave Address Rd A 1 A ----- 8 1 1 Data Byte N–1 A P Figure 10. Block Read Protocol P Bit 7 (MSB) S tW(SCLL) Bit 6 tW(SCLH) tr(SM) Bit 0 (LSB) A P tf(SM) VIH(SM) SCLK VIL(SM) th(START) tsu(SDATA) tsu(START) tsu(STOP) th(SDATA) t(BUS) tf(SM) tr(SM) VIH(SM) SDATA VIL(SM) Figure 11. Timing Diagram Serial Control Interface SMBus Hardware Interface The following diagram shows how the CDC706 clock synthesizer is connected to the SMBus. Note that the current through the pullup resistors (Rp) must meet the SMBus specifications (min 100 µA, max 350 µA). If the CDC706 is not connected to SMBus, the SDATA and SCLK inputs have to be connected with 10 kΩ resistors to VCC to avoid floating input conditions. RP RP SMB Host CDC706 9 SDATA 10 SCLK CBUS CBUS Figure 12. SMBus Hardware Interface Submit Documentation Feedback 13 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Table 2. Register Configuration Command Bitmap Adr Bit 7 Byte 0 Bit 5 Bit 4 Bit 3 Bit 2 Revision Code PLL1 Reference Divider M 9-Bit [7:0] Byte 2 PLL1 Feedback Divider N 12-Bit [7:0] PLL1 Mux PLL2 Mux PLL3 Mux PLL2 Reference Divider M 9-Bit [7:0] Byte 5 PLL2 Feedback Divider N 12-Bit [7:0] PLL1 fvco Selection PLL2 fvco Selection PLL3 fvco Selection PLL3 Reference Divider 9-Bit M [7:0] Byte 8 PLL3 Feedback Divider N [12-Bit 7:0] Byte 9 PLL Selection for P0 (Switch A) Byte 10 PLL Selection for P1 (Switch A) Input Signal Source Power Down PLL2 Ref Dev M [8] PLL2 Feedback Divider N 12-Bit [11:8] Byte 7 Byte 11 Bit 0 PLL1 Ref Dev M [8] PLL1 Feedback Divider N 12-Bit [11:8] Byte 4 Byte 6 Bit 1 Vendor Identification Byte 1 Byte 3 14 Bit 6 PLL3 Ref Dev M [8] PLL3 Feedback Divider N 12-Bit [11:8] Inp. Clock Selection Configuration Inputs S1 Configuration Inputs S0 PLL Selection for P3 (Switch A) PLL Selection for P2 (Switch A) PLL Selection for P5 (Switch A) PLL Selection for P4 (Switch A) Byte 12 Reserved Byte 13 Reserved 7-Bit Divider P0 [6:0] Byte 14 Reserved 7-Bit Divider P1 [6:0] Byte 15 Reserved 7-Bit Divider P2 [6:0] Byte 16 Reserved 7-Bit Divider P3 [6:0] Byte 17 Reserved 7-Bit Divider P4 [6:0] Byte 18 Reserved 7-Bit Divider P5 [6:0] Byte 19 Reserved Y0 Inv. or Non-Inv Y0 Slew-Rate Control Y0 Enable or Low Y0 Divider Selection (Switch B) Byte 20 Reserved Y1 Inv. or Non-Inv Y1 Slew-Rate Control Y1 Enable or Low Y1 Divider Selection (Switch B) Byte 21 Reserved Y2 Inv. or Non-Inv Y2 Slew-Rate Control Y2 Enable or Low Y2 Divider Selection (Switch B) Byte 22 Reserved Y3 Inv. or Non-Inv Y3 Slew-Rate Control Y3 Enable or Low Y3 Divider Selection (Switch B) Byte 23 Reserved Y4 Inv. or Non-Inv Y4 Slew-Rate Control Y4 Enable or Low Y4 Divider Selection (Switch B) Byte 24 Reserved Y5 Inv or Non-Inv Y5 Slew-Rate Control Y5 Enable or Low Y5 Divider Selection (Switch B) Byte 25 Reserved Byte 26 Reserved Spread Spectrum (SSC) Modulation Selection Frequency Selection for SSC 7-Bit Byte Count Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Default Device Setting The CDC706 is pre-programmed with a factory default configuration as shown below. This puts the device in an operating mode without the need to program it first. The default setting appears after power is switched on or after a power-down/up sequence until it is re-programmed by the user to a different application configuration. A new register setting is programmed via the serial SMBUS Interface. A different default setting can be programmed upon customer request. Contact a Texas Instruments sales or marketing representative for more information. fVCO1 = 216 MHz Output Switch Matrix PLL1 Divider M 1 PFD Filter Divider N 8 14 pF XO or 2LVCMOS or Differential Input P1-Div 20 LV CMOS P2-Div 8 LV CMOS P3-Div 9 LV CMOS P4-Div 32 LV CMOS P5-Div 4 LV CMOS VCO Y0 27 MHz Y1 PLL2 w/ SSC Divider M 27 Divider N 250 14 pF CLK_IN1 LV CMOS 27 MHz fVCO2 = 250 MHz CLK_IN0 27 MHz Crystal MUX P0-Div 10 PFD Filter VCO MUX Y2 27 MHz Y3 27 MHz SSC-OFF SO/CLK_SEL PROGRAMMING LOGIC fVCO3 = 225.792 MHz S1 SDATA Y4 PLL3 SMBUS LOGIC Divider M 375 27 MHz PFD Y5 SCLOCK Filter Divider N 3136 MUX 27 MHz VCO NOTE: All outputs are enabled and in non-inverting mode. S0, S1, and SSC comply according the default setting described in Byte 10 and Byte 25 respectively. Figure 13. Default Device Setting The output frequency can be calculated: fin x N , i.e. fout = 27 MHz x 8 fout = = 27 MHz M x P (1 x 8) Submit Documentation Feedback (1) 15 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Functional Description of the Logic All Bytes are read-/write-able, unless otherwise expressly mentioned. Byte 0 (read only): Vendor Identification Bits [3:0]; Revision Code Bit [7:4] (1) Revision Code X (1) X Vendor Identification X X 0 0 0 1 Byte 0 is readable by "Byte Read sequency" only. Byte 1 to 9: Reference Divider M of PLL1, PLL2, PLL3 (1) Default (2) (3) M8 M7 M6 M5 M4 M3 M2 M1 M0 Div by 0 0 0 0 0 0 0 0 0 Not allowed 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 1 0 2 0 0 0 0 0 0 0 1 1 3 • • • 1 1 1 1 1 1 1 0 1 509 1 1 1 1 1 1 1 1 0 510 1 1 1 1 1 1 1 1 1 511 By selecting the PLL divider factors, M ≤ N and 80 MHz ≤ fvco ≤ 300 MHz. Unless customer specific setting. Default setting of divider M for PLL1 = 1, for PLL2 = 27 and for PLL3 = 375. (1) (2) (3) Byte 1 to 9: Feedback Divider N of PLL1, PLL2, PLL3 (1) N11 N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 N0 Div by 0 0 0 0 0 0 0 0 0 0 0 0 Not allowed 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 1 0 2 0 0 0 0 0 0 0 0 0 0 1 1 3 Default (2) (3) • • • (1) (2) (3) 1 1 1 1 1 1 1 1 1 1 0 1 4093 1 1 1 1 1 1 1 1 1 1 1 0 4094 1 1 1 1 1 1 1 1 1 1 1 1 4095 By selecting the PLL divider factors, M ≤ N and 80 MHz ≤ fvco ≤ 300 MHz. Unless customer specific setting. Default setting of divider N for PLL1 = 8, for PLL2 = 250 and for PLL3 = 3136. Byte 3 Bit [7:5]: PLL (VCO) Bypass Multiplexer (1) PLLxMUX PLL (VCO) MUX Output Default (1) 0 PLLx Yes 1 VCO bypass Unless customer specific setting. Byte 6 Bit [7:5]: VCO Frequency Selection Mode for each PLL (1) (1) (2) 16 PLLxFVCO VCO Frequency Range 0 80-200 MHz 1 180-300 MHz Default (2) Yes This bit selects the normal-speed mode or the high-speed mode for the dedicated VCO in PLL1, PLL2 or PLL3. At power-up, the high-speed mode is selected, fVCO is 180-300 MHz. In case of higher fVCO, this bit has to be set to [1]. Unless customer specific setting. Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Byte 9 to 12: Outputs Switch Matrix (5x6 Switch A) PLL Selection for P-Divider P0-P5 (1) (2) Default (1) SWAPx2 SWAPx1 SWAPx0 Any Output Px 0 0 0 PLL bypass (input clock) 0 0 1 PLL1 P2, P3, P4, P5 0 1 0 PLL2 non-SSC P0 SSC (2) 0 1 1 1 0 0 PLL2 w/ PLL3 1 0 1 Reserved 1 1 0 Reserved 1 1 1 Reserved P1 Unless customer specific setting. PLL2 has a SSC output and non-SSC output. If SSC bypass is selected (see Byte 25, Bit [6:4]), the SSC circuitry of PLL2 is powered-down and the SSC output is reset to logic low. The non-SSC output of PLL2 is not affected by this mode and can still be used. Byte 10, Bit [1:0]: Configuration Settings of Input S0/CLK_SEL (1) (2) (3) Default (1) S01 S00 Function 0 0 If S0 is low, the PLLs and the clock-input stage are going into power-down mode, outputs are in 3-state, all actual register settings will be maintained, SMBus stays active (2) 0 1 If S0 is low, the PLL and all dividers (M-Div and P-Div) are bypassed and PLL is in power-down, all outputs are active (inv. or non-inv.), actual register settings will be maintained, SMBus stays active; this mode is useful for production test; 1 0 CLK_SEL (input clock selection — overwrites the CLK_SEL setting in Byte 10, Bit [4]) (3) — CLK_SEL is set low selects CLK_IN_IN0 — CLK_SEL is set high selects CLK_IN_IN1 1 1 Reserved Yes Unless customer specific setting. Power-down mode overwrites 3-state or low-state of S1 setting in Byte 10, Bit [3:2]. If the clock input (CLK_IN0/CLK_IN1) is selected as crystal input or differential clock input (Byte 11, Bit [7:6]) then this setting is not relevant. Byte 10, Bit [3:2]: Configuration Settings of Input S1 (1) S11 S10 0 0 If S1 is set low, all outputs are switched to a low-state (non-inv.) or high-state (inv.); 0 1 If S1 is set low, all outputs are switched to a 3-state 1 0 Reserved 1 1 Reserved Default (1) Function Yes Unless customer specific setting. Byte 10, Bit [4]: Input Clock Selection (1) (1) (2) CLKSEL Input Clock Default (2) 0 CLK_IN0 Yes 1 CLK_IN1 This bit is not relevant, if crystal input or differential clock input is selected, Byte 11, Bit [7:6]. Unless customer specific setting. Byte 11, Bit [7:6]: Input Signal Source (1) (1) (2) IS1 IS0 Function 0 0 CLK_IN0 is Crystal Oscillator Input and CLK_IN1 is serving as Crystal Oscillator Output. 0 1 CLK_IN0 and CLK_IN1 are two LVCMOS Inputs. CLK_IN0 or CLK_IN1 are selectable via CLK_SEL control pin. 1 0 CLK_IN0 and CLK_IN1 serve as differential signal inputs. 1 1 Reserved Default (2) Yes In case the crystal input or differential clock input is selected, the input clock selection, Byte 10, Bit [4], is not relevant. Unless customer specific setting. Submit Documentation Feedback 17 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Byte 12, Bit [6]: Power-Down Mode (except SMBus) (1) (2) PD Power-Down Mode Default (1) 0 Normal Device Operation Yes 1 Power Down (2) Unless customer specific setting. In power down, all PLLs and the Clock-Input-Stage are going into power-down mode, all outputs are in 3-State, all actual register settings will be maintained and SMBus stays active. Power-Down Mode overwrites 3-State or Low-State of S0 and S1 setting in Byte 10. Byte 13 to 18, Bit [6:0]: Outputs Switch Matrix - 6x7-Bit Divider P0-P5 DIVYx6 DIVYx5 DIVYx4 DIVYx3 DIVYx2 DIVYx1 DIVYx0 Div by 0 0 0 0 0 0 0 Not allowed 0 0 0 0 0 0 1 1 0 0 0 0 0 1 0 2 Default (1) (2) • • • (1) (2) 1 1 1 1 1 0 1 125 1 1 1 1 1 1 0 126 1 1 1 1 1 1 1 127 Unless customer specific setting. Default setting of divider P0 = 10, P1 = 20, P2 = 8, P3 = 9, P4 = 32, and P5 = 4 Byte 19 to 24, Bit [5:4]: LVCMOS Output Rise/Fall Time Setting at Y0-Y5 (1) SRCYx1 SRCYx0 Yx 0 0 Nominal +3 ns (tr0/tf0) 0 1 Nominal +2 ns (tr1/tf1) 1 0 Nominal +1 ns (tr2/tf2) 1 1 Nominal (tr3/tf3) Default (1) Yes Unless customer specific setting. Byte 19 to 24, Bit [2:0]: Outputs Switch Matrix (6 x 6 Switch B) Divider (P0-P5) Selection for Outputs Y0-Y5 (1) SWBYx2 SWBYx1 SWBYx0 Any Output Yx 0 0 0 Divider P0 0 0 1 Divider P1 0 1 0 Divider P2 0 1 1 Divider P3 1 0 0 Divider P4 1 0 1 Divider P5 1 1 0 Reserved 1 1 1 Reserved Default (1) Y0, Y1, Y2, Y3, Y4, Y5 Unless customer specific setting. Byte 19 to 24, Bit [3]: Output Y0-Y5 Enable or Low-State (1) Default (1) ENDISYx Output Yx 0 Disable to low 1 Enable Yes INVYx Output Yx Status Default (1) 0 Non-inverting Yes 1 Inverting Unless customer specific setting. Byte 19 to 24, Bit [6]: Output Y0-Y5 Non-Inverting/Inverting (1) 18 Unless customer specific setting. Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Byte 25, Bit [3:0]: SSC Modulation Frequency Selection in the Range of 30 kHz 60 kHz (1) fvco (MHz) FSSC3 FSSC2 FSSC1 FSSC0 Modulation Factor 100 110 120 130 140 150 160 167 0 0 0 0 5680 17.6 19.4 21.1 22.9 24.6 26.4 28.2 29.4 0 0 0 1 5412 18.5 20.3 22.2 24.0 25.9 27.7 29.6 30.9 0 0 1 0 5144 19.4 21.4 23.3 25.3 27.2 29.2 31.1 32.5 0 0 1 1 4876 20.5 22.6 24.6 26.7 28.7 30.8 32.8 34.2 0 1 0 0 4608 21.7 23.9 26.0 28.2 30.4 32.6 34.7 36.2 0 1 0 1 4340 23.0 25.3 27.6 30.0 32.3 34.6 36.9 38.5 0 1 1 0 4072 24.6 27.0 29.5 31.9 34.4 36.8 39.3 41.0 0 1 1 1 3804 26.3 28.9 31.5 34.2 36.8 39.4 42.1 43.9 1 0 0 0 3536 28.3 31.1 33.9 36.8 39.6 42.4 45.2 47.2 1 0 0 1 3286 30.4 33.5 36.5 39.6 42.6 45.6 48.7 50.8 1 0 1 0 3000 33.3 36.7 40.0 43.3 46.7 50.0 53.3 55.7 1 0 1 1 2732 36.6 40.3 43.9 47.6 51.2 54.9 58.6 61.1 1 1 0 0 2464 40.6 44.6 48.7 52.8 56.8 60.9 64.9 67.8 1 1 0 1 2196 45.5 50.1 54.6 59.2 63.8 68.3 72.9 76.0 1 1 1 0 1928 51.9 57.1 62.2 67.4 72.6 77.8 83.0 86.6 1 1 1 1 1660 60.2 66.3 72.3 78.3 84.3 90.4 96.4 100.6 (1) (2) fmod [kHz] Default (2) Yes The PLL has to be bypassed (turned off) when changing SSC Modulation Frequency Factor on-the-fly. This can be done by following programming sequence: bypass PLL2 (Byte 3, Bit 6 = 1); write new Modulation Factor (Byte 25); re-activate PLL2 (Byte 3, Bit 6 = 0). Unless customer specific setting. Submit Documentation Feedback 19 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 (1) Byte 25, Bit [6:4]: SSC Modulation Amount SSC2 (1) (2) (3) SSC1 SSC0 Default (2) Function PLL (3) 0 0 0 SSC Modulation Amount 0% = SSC bypass for 0 0 1 SSC Modulation Amount ±0.1% (center spread) 0 1 0 SSC Modulation Amount ±0.25% (center spread) 0 1 1 SSC Modulation Amount ±0.4% (center spread) 1 0 0 SSC Modulation Amount 1% (down spread) 1 0 1 SSC Modulation Amount 1.5% (down spread) 1 1 0 SSC Modulation Amount 2% (down spread) 1 1 1 SSC Modulation Amount 3% (down spread) Yes The PLL has to be bypassed (turned off) when changing SSC Modulation Amount on-the-fly. This can be done by following programming sequence: bypass PLL2 (Byte 3, Bit 6 = 1); write new Modulation Amount (Byte 25); re-activate PLL2 (Byte 3, Bit 6 = 0). Unless customer specific setting. If SSC bypass is selected, SSC circuitry of PLL2 is powered-down and the SSC output is reset to logic low. The non-SSC output of PLL2 is not affected by this mode and can still be used. Byte 26, Bit [6:0]: Byte Count (1) BC6 BC5 BC4 BC3 BC2 BC1 BC0 No. of Bytes 0 0 0 0 0 0 0 Not allowed 0 0 0 0 0 0 1 1 0 0 0 0 0 1 0 2 0 0 0 0 0 1 1 3 0 1 1 27 Default (2) • • • 0 0 1 1 • • • (1) (2) 20 1 1 1 1 1 0 1 125 1 1 1 1 1 1 0 126 1 1 1 1 1 1 1 127 Defines the number of Bytes, which will be sent from this device at the next Block Read protocol. Unless customer specific setting. Submit Documentation Feedback Yes CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 FUNCTIONAL DESCRIPTION Clock Inputs (CLK_IN0 and CLK_IN1) The CDC706 features two clock inputs which can be used as: • Crystal oscillator input (default setting) • Two independent single-ended LVCMOS inputs • Differential signal input The dedicated clock input can be selected by the input signal source Bit [7:6] of Byte 11. Crystal Oscillator Inputs The input frequency range in crystal mode is 8 MHz to 54 MHz. The CDC706 uses a Pierce-type oscillator circuitry with included feedback resistance for the inverting amplifier. The user, however, has to add external capacitors CX0, CX1) to match the input load capacitor from the crystal (see Figure 14). The required values can be calculated: CX0 = CX1 = 2 x CL– CICB, where CL is the crystal load capacitor as specified for the crystal unit and CICB is the input capacitance of the device including the board capacitance (stray capacitance of PCB). For example, for a fundamental 27-MHz crystal with CL of 9 pF and CICB of 4 pF, CX0 = CX1 = (2 x 9 pF) – 3 pF = 15 pF. It is important to use a short PCB trace from the device to the crystal unit to keep the stray capacitance of the oscillator loop to a minimum. CLK_IN0 CX0 crystal unit CLK_IN1 Input source select (from SMBUS Register) CICB CICB XO or 2LVCMOS or Differential Input CX1 Figure 14. Crystal Input Circuitry In order to ensure a stable oscillating, a certain drive power must be applied. The CDC706 features an input oscillator with adaptive gain control which relieves the user to manually program the gain. The drive level is the amount of power dissipated by the oscillating crystal unit and is usually specified in terms of power dissipated by the resonator (equivalent series resistance (ESR)). Figure 15 gives the resulting drive level vs crystal frequency and ESR. Submit Documentation Feedback 21 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 100 C = 18 pF Upk = 300 mV 90 ERS ERS ERS ERS ERS ERS 80 Pdrive − mW 70 = = = = = = 60 50 40 30 25 15 W W W W W W 60 50 40 30 ~21 mW 20 10 0 5 10 15 20 25 30 35 40 45 50 55 Frequency − MHz Figure 15. Crystal Drive Power For example, if a 27-MHz crystal with ESR of 50 Ω is used and 2 x CL is 18 pF, the drive power is 21 µW. Drive level should be held to a minimum to avoid over driving the crystal. The maximum power dissipation is specified for each type of crystal in the oscillator specifications, i.e., 100 µW for the example above. Single-Ended LVCMOS Clock Inputs When selecting the LVCMOS clock mode, CLK_IN0 and CLK_IN1 act as regular clock inputs pins and can be driven up to 200 MHz. Both clock inputs circuitry are equal in design and can be used independently to each other (see Figure 16). The internal clock select bit, Byte 10, Bit [4], selects one of the two input clocks. CLK_IN0 is the default selection. There is also the option to program the external control pin S0/CLK_SEL as clock select pin, Byte 10, Bit [1:0]. The two clock inputs can be used for redundancy switching, i.e. to switch between a primary clock and secondary clock. Note a phase difference between the clock inputs may require PLL correction. Also in case of different frequencies between the primary and secondary clock, the PLL has to re-lock to the new frequency. Input Source Select (From SMBUS Register) CLK_IN0 CLK_IN1 XO or 2LVCMOS or Differential input CLK_SEL (A) A. CLK_SEL is optional and can be configured by SMBUS setting. Figure 16. LVCMOS Clock Input Circuitry 22 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Differential Clock Inputs The CDC706 supports differential signaling as well. In this mode, CLK_IN0 and CLK_IN1 pin serve as differential signal inputs and can be driven up to 200 MHz. The minimum magnitude of the differential input voltage is 100 mV over a differential common-mode input voltage range of 200 mV to VCC– 0.6. If LVDS or LVPECL signal levels are applied, ac-coupling and a biasing structure is recommended to adjust the different physical layers (see Figure 17). The capacitor removes the dc component of the signal (common-mode voltage), while the ac component (voltage swing) is passed on. A resistor pull-up and/or pull-down network represents the biasing structure used to set the common-mode voltage on the receiver side of the ac-coupling capacitor. DC coupling is also possible. Input source select (from SMBUS) CLK_IN0 XO or 2LVCMOS or Differential input CLK_IN1 Figure 17. Differential Clock Input Circuitry PLL Configuration and Setting The CDC706 includes three PLLs which are equal in function and performance. Except PLL2 which in addition supports spread spectrum clocking (SSC) generation. Figure 18 shows the block diagram of the PLL. VCO Bypass PLLx Input Clock 9−Bit Divider M 1 .. 511 12−Bit Divider N 1 .. 4095 PFD Filter VCO MUX SSC (PLL2 only) PLL output SSC output (PLL2 Only) Programming Figure 18. PLL Architecture All three PLLs are designed for easiest configuration. The user just has to define the input and output frequencies or the divider (M, N, P) setting respectively. All other parameters, such as charge-pump current, filter components, phase margin, or loop bandwidth are controlled and set by the device itself. This assures optimized jitter attenuation and loop stability. The PLL support normal-speed mode (80 MHz ≤ fVCO ≤ 200 MHz) and high-speed mode (180 MHz ≤ fVCO ≤ 300 MHz) which can be selected by PLLxFVCO (Bit [7:5] of Byte 6). The respective speed option assures stable operation and lowest jitter. The divider M and divider N operates internally as fractional divider for fVCO up to 250 MHz. This allows fractional divider ratio for zero ppm output clock error. In case of fVCO > 250 MHz, it is recommended that integer factors of N/M are used only. For optimized jitter performance, keep divider M as small as possible. Also, the fractional divider concept requires a PLL divider configuration, M ≤ N (or N/M ≥ 1). Submit Documentation Feedback 23 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Additionally, each PLL supports two bypass options: • PLL Bypass and • VCO Bypass In PLL bypass mode, the PLL completely is bypassed, so that the input clock is switched directly to the Output-Switch-A (SWAPxx of Byte 9 to 12). In the VCO bypass mode, only the VCO of the respective PLL is bypassed by setting PLLxMUX to 1 (Bit [7:5] of Byte 3). But the divider M still is useable and expands the output divider by additional 9-bits. This gives a total divider range of M x P = 511 x 127 = 64897. In VCO bypass mode the respective PLL block is powered down and minimizes current consumption. Table 3. Example for Divide, Multiplication, and Bypass Operation Equation (1) fIN [MHz] fOUT-desired [MHz] fOUT-actual [MHz] Fractional (2) fOUT = fIN x (N/M)/P 30.72 155.52 Integer Factor (3) fOUT = fIN x (N/M)/P 27 270 fOUT = fIN/(M x P) 30.72 0.06 Function VCO bypass (1) (2) (3) Divider fVCO [MHz] M N P N/M 155.52 16 81 1 5.0625 155.52 270 1 10 1 10 270 0.06 8 — 64 — — P-divider of Output-Switch-Matrix is included in the calculation. Fractional operation for fVCO≤ 250 MHz. Integer operation for fVCO > 250 MHz. Spread Spectrum Clocking and EMI Reduction In addition to the basic PLL function, PLL2 supports spread spectrum clocking (SSC) as well. Thus, PLL 2 features two outputs, a SSC output and a non-SSC output. Both outputs can be used in parallel. The mean phase of the Center Spread SSC modulated signal is equal to the phase of the non-modulated input frequency. SSC is selected by Output-Switch-A (SWAPxx of Byte 9 to 12). SSC also is bypass-able (Byte 25, Bit [6:4]), which powers-down the SSC output and set it to logic low state. The non-SSC output of PLL2 is not affected by this mode and can still be used. SSC is an effective method to reduce electro-magnetic interference (EMI) noise in high-speed applications. It reduces the RF energy peak of the clock signal by modulating the frequency and spread the energy of the signal to a broader frequency range. Because the energy of the clock signal remains constant, a varying frequency that broadens the overtones necessarily lowers their amplitudes. Figure 19 shows the effect of SSC on a 54-MHz clock signal for DSP Down Spread 3% 9th Harmonic, fm = 60 kHz 11.3dB 11.3 dB Center Spread + 0.4% 9th Harmonic, fm = 60 kHz 7 dB 7dB Figure 19. Spread Spectrum Clocking With Center Spread and Down Spread The peak amplitude of the modulated clock is 11.3 dB lower than the non-modulated carrier frequency for down spread and radiated less electro-magnetic energy. 24 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 In SSC mode, the user can select the SSC modulation amount and SSC modulation frequency. The modulation amount is the frequency deviation based to the carrier (min/max frequency), whereas the modulation frequency determines the speed of the frequency variation. In SSC mode, the maximum VCO frequency is limited to 167 MHz. SSC Modulation Amount The CDC706 supports center spread modulation and down spread modulation. In center spread, the clock is symmetrically shifted around the carrier frequency and can be ±0.1%, ±0.25%, and ±0.4%. At down spread, the clock frequency is always lower than the carrier frequency and can be 1%, 1.5%, 2%, and 3%. The down spread is preferred if a system can not tolerate an operating frequency higher than the nominal frequency (over-clocking problem). Example: Modulation Type Minimum Frequency Center Frequency Maximum Frequency 54 MHz 54.135 MHz A ±0.25% center spread 53.865 MHz B 1% down spread 53.46 MHz — 54 MHz C 0.5% down spread (1) 53.73 MHz 53.865 MHz 54 MHz (1) A down spread of 0.5% of a 54-MHz carrier is equivalent to 59.865 MHz at a center spread of ±0.25%. SSC Modulation Frequency The modulation frequency (sweep rate) can be selected between 30 kHz and 60 kHz. It is also based on the VCO frequency as shown in the SSC Modulation Frequency Selection. As shown in Figure 20, the damping increases with higher modulation frequencies. It may be limited by the tracking skew of a downstream PLL. The CDC706 uses a triangle modulation profile which is one of the common profiles for SSC. 12 3% Down Spread EMI Reduction− dB 11 2% Down Spread 10 9 8 +0.4 Center Spread 7 6 +0.25 Center Spread 5 4 3 30 40 50 60 fmodulation − kHz Figure 20. EMI Reduction vs fModulation and fAmount Further EMI Reduction The optimum damping is a combination of modulation amount, modulation frequency and the harmonics which are considered. Note that higher order harmonic frequencies results in stronger EMI reduction because of respective higher frequency deviation. As seen in Figure 21 and Figure 22, a slower output slew rate and/or smaller output signal amplitude helps to reduce EMI emission even more. Both measures reduce the RF energy of clock harmonics. The CDC706 allows slew rate control in four steps between 0.6 ns and 3.3 ns (Byte 19-24, Bit [5:4]). The output amplitude is set by the two independent output supply voltage pins, VCCOUT1 and VCCOUT2, and can vary from 2.3 V to 3.6 V. Even a lower output supply voltage down to 1.8 V works, but the maximum frequency has to be considered. Submit Documentation Feedback 25 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Slew-Rate for VCCOUT = 2.5 V Slew-Rate for VCCOUT = 3.3 V −2.5dB −3dB 6.4dB 5.6dB 7dB 11.3dB nom−1 nom−1 nom nom nom+2 nom+2 Figure 21. EMI Reduction vs Slew-Rate and Vccout 5 EMI Reduction − dB (Relative to Nom) 4 3 2 1 0 −1 2.5 V 3V 3.6 V VCCOUT Figure 22. EMI Reduction vs Vccout Multi-Function Control Inputs S0 and S1 The CDC706 features two user definable inputs pins which can be used as external control pins or address pins. When programmed as control pins, they can function as clock select pin, enable/disable pin or device power-down pin. If both pins used as address-bits, up to four devices can be connected to the same SMBus. The respective function is set in Byte 10; Bit [3:0]. Table 4 shows the possible setting for the different output conditions, clock select and device addresses. 26 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Table 4. Configuration Setting of Control Inputs Configuration Bits Byte 10, Bit [3:2] External Control Pins S11 S10 S01 S00 S1 (Pin 2) S0 (Pin 1) 0 X 0 X 1 0 0 0 X 0 0 1 0 X 0 X 0 0 X 0 X (1) (2) Device Function Byte 10, Bit [1:0] Yx Outputs Power Down Pin 2 Pin 1 1 Active No Output ctrl Output ctrl 1 Low/High (1) No Output ctrl Output ctrl 0 1 3-State Outputs only Output ctrl Output ctrl 0 X 0 3-State PLL, inputs and outputs Output ctrl Output ctrl and pd 0 1 0 0 S10=0: low/high (1) S10=1: 3-State PLL only Output ctrl PLL and Div bypass 0 1 1 0 Active PLL only Output ctrl PLL and Div bypass No Output ctrl CLK_SEL No Output ctrl CLK_SEL 0 X 1 0 0 0/1 (2) S10=0: Low/High (1) S10=1: 3-State 0 X 1 0 1 0/1 (2) Active A non-inverting output will be set to low and an inverting output will be set to high. If S0 is 0, CLK_IN0 is selected; if S0 is 1, CLK_IN1 is selected. As shown in Table 4, there is a specific order of the different output condition: Power-down mode overwrites 3-state, 3-state overwrites low-state, and low-state overwrites active-state. Output Switching Matrix The flexible architecture of the output switch matrix allows the user to switch any of the internal clock signal sources via a free-selectable post-divider to any of the six outputs. As shown in Figure 23, the CDC706 is based on two banks of switches and six post-dividers. Switch A comprises six 5-Input-Muxes which selects one of the four PLL clock outputs or directly selects the input clock and feed it to one of the 7-bit post-divider (P-Divider). Switch B is made up of six 6-Input-Muxes which takes any post-divider and feeds it to one of the six outputs, Yx. Switch B was added to the output switch matrix to ensure that outputs frequencies derive from one P-divider are 100% phase aligned. Also, the P-divider is built in a way that every divide factor is automatically duty-cycle corrected. Changing the divider value on the fly may cause a glitch on the output. Submit Documentation Feedback 27 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Internal Clock Sources Output Switch Matrix 5x6 − Switch A 7-Bit Divider Outputs 6x6 − Switch B P0 Y0 (1..127) Input CLK P1 (PLL Bypass) Y1 (1..127) PLL 1 P2 Y2 (1..127) PLL 2 non SSC P3 Y3 (1..127) P4 PLL 2 w/ SSC Y4 (1..127) P5 Y5 (1..127) PLL 3 Programming PLL/Input_Clk Selection P-Divider Setting P-Divider Selection Output Selection: Active/Low/3-State/ Inverting/Non-Inverting Slew Rate/VCCOUT Figure 23. CDC706 Output Switch Matrix In addition, the outputs can be switched active, low or 3-state and/or 180 degree phase shifted. Also the outputs slew-rate and the output-voltage is user selectable. LVCMOS Output Configuration The output stage of the CDC706 supports all common output setting, such as enable, disable, low-state and signal inversion (180 degree phase shift). It further features slew-rate control (0.6 ns to 3.3 ns) and variable output supply voltage (2.3 V to 3.6 V). Clock VCCOUT1/VCCOUT2 P−div(0) P−div(1) P−div(2) P−div(3) P−div(4) P−div(5) output output output output output output P−Divider Select Inversion Select Slew-Rate Control Low Select Enable/Disable div by 3 M U X Sel Buffer Yx Inverting Slew Rate S1 (Optional all outputs low or 3−State) Low Select Enable/Disable Figure 24. Block Diagram of Output Architecture All • • • • • 28 Figure 25. Example for Output Waveforms output settings are programmable via SMBus: enable, disable, low-state via external control pins S0 and S1 → Byte 10, Bit[3:0] enable or disable-to-low → Byte 19 to 24, Bit[3] inverting/non-inverting → Byte 19 to 24, Bit[6] slew-rate control → Byte 19 to 24, Bit[5:4] output swing → external pins VCCOUT1 (Pin 14) and VCCOUT2 (Pin 18) Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Performance Data: Output Skew, Jitter, Cross Coupling, Noise Rejection (Spur-Suppression), and Phase Noise Output Skew Skew is an important parameter for clock distribution circuits. It is defined as the time difference between outputs that are driven by the same input clock. Table 5 shows the output skew (tsk(o)) of the CDC706 for high-to-low and low-to-high transitions over the entire range of supply voltages, operating temperature and output voltage swing. Table 5. Output Skew PARAMETER tsk(o) Vccout TYP MAX UNIT 2.5 V 130 250 ps 3.3 V 130 200 ps Jitter Performance Jitter is a major parameter for PLL-based clock driver circuits. This becomes important as speed increases and timing budget decreases. The PLL and internal circuits of CDC706 are designed for lowest jitter. The peak-to-peak period jitter is only 60 ps (typical). Table 6 gives the peak-to-peak and rms deviation of cycle-to-cycle jitter, period jitter and phase jitter as taken during characterization. Table 6. Jitter Performance of CDC706 PARAMETER tjit(cc) tjit(per) tjit(phase) (1) TYP (1) fout MAX (1) UNIT Peak-Peak rms (one sigma) Peak-Peak rms (one sigma) 50 MHz 55 – 75 – 133 MHz 50 – 85 – 245.76 MHz 45 – 60 – 50 MHz 60 4 76 7 133 MHz 55 5 84 11 245.76 MHz 55 5 72 8 50 MHz 730 90 840 115 133 MHz 930 130 1310 175 245.76 MHz 720 90 930 125 ps ps ps All typical and maximum values are at VCC = 3.3 V, temperature = 25°C, Vccout = 3.3 V; one output is switching, data taken over several 10000 cycles. Figure 26, Figure 27, and Figure 28 show the relationship between cycle-to-cycle jitter, period jitter, and phase jitter over 10000 samples. The jitter varies with a smaller or wider sample window. The cycle-to-cycle jitter and period jitter show the measured value whereas the phase jitter is the accumulated period jitter. Cycle-to-Cycle jitter (tjit(cc)) is the variation in cycle time of a clock signal between adjacent cycles, over a random sample of adjacent cycle pairs. Cycle-to-cycle jitter will never be greater than the period jitter. It is also known as adjacent cycle jitter. Submit Documentation Feedback 29 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 40 30 20 tjit(cc) [ps] 10 0 −10 −20 −30 −40 1 1001 2001 3001 4001 5001 Cycle 6001 7001 8001 9001 10001 Figure 26. Snapshot of Cycle-to-Cycle Jitter Period jitter (tjit(per)) is the deviation in cycle time of a clock signal with respect to the ideal period (1/fo) over a random sample of cycles. In reference to a PLL, period jitter is the worst-case period deviation from the ideal that would ever occur on the PLLs outputs. This is also referred to as short-term jitter. 25 20 15 tjit(per) [ps] 10 5 0 −5 −10 −15 −20 −25 1 1001 2001 3001 4001 5001 6001 7001 Cycle Figure 27. Snapshot of Period Jitter 30 Submit Documentation Feedback 8001 9001 10001 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Phase jitter (tjit(phase)) is the long-term variation of the clock signal. It is the cumulative deviation in t(Θ) for a controlled edge with respect to a t(Θ) mean in a random sample of cycles. Phase jitter, Time Interval Error (TIE), or Wander are used in literature to describe long-term variation in frequency. As of ITU-T: G.810, wander is defined as phase variation at rates less than 10 Hz while jitter is defined as phase variation greater than 10 Hz. The measurement interval must be long enough to gain a meaningful result. Wander can be caused by temperature drift, aging, supply voltage drift, etc. 300 250 200 150 tjit(phase) [ps] 100 50 0 −50 −100 −150 −200 −250 −300 1 1001 2001 3001 4001 5001 Cycle 6001 7001 8001 9001 10001 Figure 28. Snapshot of Phase Jitter Jitter depends on the VCO frequency (fVCO) of the PLL. A higher fVCO results in better jitter performance compared to a lower fVCO. The VCO frequency can be defined via the M- and N-divider of the PLL As the CDC706 supports a pretty wide frequency range, the device offers a VCO Frequency Selection Bit, Bit [7:5] of Byte 6. This bit defines the jitter-optimized frequency range of each PLL. The user can select between the normal-speed mode (80 MHz to 200 MHz) and the high-speed mode (180 MHz to 300 MHz). Figure 29 shows the jitter performance over fVCO for the two frequency ranges. Submit Documentation Feedback 31 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 300 280 o TA = 25 C, VCC = 3.3 V, M div = 4, N div = 15, P div = 3 260 240 220 tjit(per)p-p − ps 200 180 fVCO Frequency Range for Normal-Speed Mode 160 fVCO Frequency Range for High-Speed Mode 140 120 High-Speed Mode >180 MHz 100 80 60 40 Normal-Speed Mode < 200 MHz 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 fVCO − MHz Set Point Figure 29. Period Jitter vs fVCO for Normal-Speed Mode and High-Speed Mode The TI Pro Clock software automatically calculates the PLL parameter for jitter-optimized performance. Cross Coupling, Spur Suppression and Noise Rejection Cross-Coupling in ICs occurs through interactions between several parts of the chip such as between output stages, metal lines, bond wires, substrate, etc. The coupling can be capacitive, inductive and resistive (ohmic) induced by output switching, leakage current, ground bouncing, power supply transients, etc. The CDC706 is designed in BiCMOS process technology incorporating silicon-germanium (SiGe) technology. This process gives excellent performance in linearity, low power consumption, best-in-class noise performance and very good isolation characteristic between the on-chip components. The good isolation was a major criteria to use BiCMOS process as it minimizes the coupling effect. Even if all three PLLs are active and all outputs are on, the noise suppression is clearly above 50 dB. Figure 30 and Figure 31 show an example of noise coupling, spur-suppression, and power supply noise rejection of CDC706. Die respective measurement conditions are shown in Figure 30 and Figure 31. 32 Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 Figure 30. Noise Coupling and Spur Suppression 56 dB w Measured Y0: 48 MHz w Y1, Y2, Y3, Y4 & Y5 tri−stated w Inserted 30mV 1MHz @ Vcc = 3.3V carrier 48MHz carrier 48MHz spurs at 47MHz&49MHz spur 47MHz and fundamental at 1MHz Figure 31. Power Supply Noise Rejection Phase Noise Characteristic In high-speed communication systems, the phase noise characteristic of the PLL frequency synthesizer is of high interest. Phase noise describes the stability of the clock signal in the frequency domain, similar to the jitter specification in the time domain. Phase noise is a result of random and discrete noise causing a broad slope and spurious peaks. The discrete spurious components could be caused by known clock frequencies in the signal source, power line interference, and mixer products. The broadening caused by random noise fluctuation is due to phase noise. It can be the result of thermal noise, shot noise and/or flicker noise in active and passive devices. Important factor for PLL synthesizer is the loop bandwidth (–3 dB cut-off frequency) — large loop bandwidth (LBW) results in fast transient response but have less reference spur attenuation. The LBW of the CDC706 is about 100 kHz to 250 kHz, dependent on selected PLL parameter. For the CDC706, two phase noise characteristics are of interest: The phase noise of the crystal-input stage and the phase noise of the internal PLL (VCO). Figure 32 shows the respective phase noise characteristic. Submit Documentation Feedback 33 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 −50 Phase Noise Comparison −60 fOUT 135 MHz fVCO 135 MHz vs 270 MHz −70 CDC706 fOUT 135 MHz fVCO 135 MHz dBc/Hz −80 CDC706 fOUT 135 MHz fVCO 270 MHz −90 −100 −110 −120 −130 −140 −150 1.0E+01 CDC706 Cyrstal 27 MHz Input 27 MHz Buffered Output 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07 foffset - [Hz] Figure 32. Phase Noise Characteristic - foffset - Hz PLL Lock-Time Some applications use frequency switching, i.e. to change frequency in TV application (switching between channels) or change the PCI-X frequency in computers. The time spent by the PLL in achieving the new frequency is of main interest. The lock time is the time it takes to jump from one specified frequency to another specified frequency within a given frequency tolerance (see Figure 33). It should be low, because a long lock time impacts the data rate of the system. The PLL-Lock-Time depends on the device configuration and can be changed by the VCO frequency, i.e. by changing the M/N divider values. Table 7 gives the typical lock times of the CDC706 and Figure 33 shows a snapshot of a frequency switch. Table 7. CDC706 PLL Lock-Times Description Lock Time Unit Frequency change via reprogramming of N/M counter 100 µs Frequency change via CLK_SEL pin (switching between CLK_IN0 and CLK_IN1) 100 µs Power-up lock time with system clock 50 µs 300 (1) µs Power-up lock time with 27 MHz Crystal at CLK_IN0 and CLK_IN1 (1) 34 Is the result of Crystal lock time (200 µs) and PLL lock time (100 µs). Submit Documentation Feedback CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 fVCO (MHz) Start Condition: Acknowledge of N-Divider Byte Frequency Response Curve of Y0 297 EVM Board Configuration: • Y0 (PLL1), Y1 3 state • CLK_IN: Crystal 27 MHz • measured Channel: Y0 Measurement: • Start Condition: ƒ(M = 10, N = 30) = 81 MHz • Byte 2 write: N = 30 (81 MHz) ³ N = 110 (297 MHz) Result: • 60 ms to PLL Pull In • 90 ms to PLL Phase Lock 81 60 0 t [ms] 20 ms/div Figure 33. Snapshot of the PLL Lock-Time Power Supply Sequencing The CDC706 includes three power supply pins, VCC, VCCOUT1, and VCCOUT2. There are no power supply sequencing requirements, as the three power nodes are separated from each other. So, power can be supplied in any order to the three nodes. Also, the part has a power-up circuitry which switches the device on if VCC exceeds 2.1 V (typical) and switches the device off at VCC < 1.7 V (typical). In power-down mode, all outputs and clock inputs are switched off. Device Behavior During Supply Voltage Drops The CDC706 has a Power-Up-Circuit, which activates the device function at VPUC_ON (typical 2.1 V). At the same time, the ROM information is loaded into the register. This mechanism ensures that there is a pre-defined default after Power-Up and no need to reprogram the CDC706 in the application. In the event of a supply-voltage-drop, the Power-Up-Circuit assures that there is always a defined setup within the register. Figure 34 shows possible voltage drops with different amplitudes. V VCC Typ 3.3 V A VPUC_ON Typ 2.1 V VPUC_OFF Typ 1.7 V B C D GND t Figure 34. Different Voltage Drops on VCC During Operation Submit Documentation Feedback 35 CDC706 www.ti.com SCAS829A – SEPTEMBER 2006 – REVISED MARCH 2007 The CDC706 Power-Up-Circuit has an inbuilt hysteresis. If the voltage stays above VPUC_OFF, which is typically at 1.7 V, the register content stays unchanged. If the voltage drops below VPUC_OFF, the internal register is reloaded by the ROM after VPUC_ON is crossed again. VPUC_ON is typically 2.1 V. Table 8 show the content of the ROM and the Register after above voltage drops scenarios. Table 8. ROM and Register Content After VCC Drop Power Drop ROM Content Register Content A Unchanged Unchanged B Unchanged Unchanged C Unchanged Reloaded from ROM D Unchanged Reloaded from ROM EVM and Programming SW The CDC706 EVM is a development kit consisting of a performance evaluation module, the TI Pro Clock software, and the User's Guide. Contact Texas Instruments sales or marketing representative for more information. 36 Submit Documentation Feedback PACKAGE OPTION ADDENDUM www.ti.com 16-Mar-2007 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty CDC706PW ACTIVE TSSOP PW 20 70 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CDC706PWG4 ACTIVE TSSOP PW 20 70 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CDC706PWR ACTIVE TSSOP PW 20 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CDC706PWRG4 ACTIVE TSSOP PW 20 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 17-May-2007 TAPE AND REEL INFORMATION Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com Device CDC706PWR 17-May-2007 Package Pins PW 20 Site Reel Diameter (mm) Reel Width (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) MLA 330 16 6.95 7.1 1.6 8 TAPE AND REEL BOX INFORMATION Device Package Pins Site Length (mm) Width (mm) Height (mm) CDC706PWR PW 20 MLA 342.9 336.6 28.58 Pack Materials-Page 2 W Pin1 (mm) Quadrant 16 PKGORN T1TR-MS P MECHANICAL DATA MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999 PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PINS SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°– 8° A 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064/F 01/97 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-153 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Telephony www.ti.com/telephony Low Power Wireless www.ti.com/lpw Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2007, Texas Instruments Incorporated