AIMTEC AME15-512TCJZ 15 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AME15-CJZ
15 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:




I/O Isolation 3000VAC
Operating Temp: -25 °C to +70 °C
Input: 85-264VAC, 47-63Hz, or 120-370VDC
Over current, Over Voltage Protection




Continuous Short circuit protection
Energy Star compliant
Compact package
Efficiency up to 84%
Models
Single output
Model
AME15-3.3SCJZ
AME15-5SCJZ
AME15-9SCJZ
AME15-12SCJZ
AME15-15SCJZ
AME15-24SCJZ
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
120-370
120-370
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
Output
Voltage
(V)
3.3
5
9
12
15
24
Output
Current max
(A)
3
2.8
1.6
1.25
1
0.625
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
72000
44800
13760
5200
5120
880
73
76
78
80
80
84
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
±12800
±2350
±3120
±400
76
81
83
83
Models
Dual output
Model
AME15-5DCJZ
AME15-12DCJZ
AME15-15DCJZ
AME15-24DCJZ
Output
Voltage
(V)
±5
±12
±15
±24
Output
Current max
(A)
±1.5
±0.65
±0.5
±0.31
Models
Triple output
Model
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Voltage
(V)
Auxiliary
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
AME15-505TCJZ
AME15-512TCJZ
AME15-515TCJZ
AME15-524TCJZ
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
5
5
5
5
±5
±12
±15
±24
2/±0.5
2/±0.2
1.8/±0.2
2/±0.1
10800/±2160
17280/±2160
5920/±370
1600/±130
75
77
78
78
Models
Asymmetric Separated Dual output
Model
AME15-505DCJZ
AME15-512DCJZ
AME15-515DCJZ
AME15-524DCJZ
www.aimtec.com
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
Output
Voltage
(V)
5/5
5/12
5/15
5/24
Tel: +1 514 620 2722
Output
Current max
(A)
2.2/0.8
2/0.4
2/0.3
2/0.2
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
10800/2960
8640/1200
6480/800
12900/800
76
80
80
81
Toll free: + 1 888 9 AIMTEC
(924
6832)
F 052e R8.A
1 of 5
North America only
Series AME15-CJZ
15 Watt | AC-DC / DC-DC Converter
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz
Recommended slow blow type


10
20

2
Maximum
370
220
Units
mA
mA
A
A
mA
A
0.3
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Line regulation
Load regulation (single output)
Load Regulation (dual output)
Load Regulation (triple &
asymmetric separated output)
Minimum load
Full load, main output
Full load, auxiliary output
10-100% load
10-100% Balanced load
10-100% Balanced load, main output
10-100% Balanced load, auxiliary output
Single output
Others
Ripple & Noise *
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Hold-up time
±2
±0.5
±1.5
±1
±2
±3
±5
0
10
50
15
80
Maximum
Units
%
%
%
%
%
150
%
%
mV p-p
ms
ms
Rated
Units
3000
500
VAC
VDC
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation voltage between Main and Auxiliary
output
Isolation Resistance
Typical
60 sec
60 sec
>1000
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
65
KHz
Protection class
Class II
Over current protection
≥110
% of Iout
Over voltage protection
Zener diode clamp
Short circuit protection
Continuous, Auto recovery
oC
Operating temperature
See derating curve
-25 to +70
oC
Storage temperature
-25 to +105
oC
Maximum Case temperature
100
Temperature coefficient
±0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
85
g
Dimensions (L x W x H)
2.44 x 1.77 x 0.89 inches 62.0 x 45.0 x 22.50 mm
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
Tel: +1 514 620 2722
Toll free: + 1 888 9 AIMTEC
(924
6832)
F 052e R8.A
2 of 5
North America only
Series AME15-CJZ
15 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE (single output models only)
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
Dimensions
2
1
Bottom
View
7
6
5
4
3
1
Top View
5.00
(0.20)
17.50
(0.69)
45.00
(1.77)
12.50
(0.49)
5.00
(0.20)
62.00
(2.44)
3
4
5
6
7
2
54.00
(2.13)
4.00
(0.16)
4.00
(0.16)
DIV: 10.00 (0.40)
22.50
(0.89)
Ø 1.50 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
6.00
(0.24)
1.00
(0.04)
Pin Out Specifications
Pin
Single
Dual
Triple
Asymmetric Dual
1
2
3
4
5
6
7
AC Input (N)
AC Input (L)
-V Output
No pin
No pin
No pin
+V Output
AC Input (N)
AC Input (L)
-V Output
No pin
Common
No pin
+V Output
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
-V Output 2
Common
+V Output 2
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
No pin
-V Output 2
+V Output 2
www.aimtec.com
Tel: +1 514 620 2722
Toll free: + 1 888 9 AIMTEC
(924
6832)
F 052e R8.A
3 of 5
North America only
Series AME15-CJZ
15 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
100
100
80
Output Power (%)
Output power (%)
Free Air Convection
Safe Operating Area
70
Input 100-240VAC or
120-340VDC
60
40
80
75
Safe Operating Area
60
40
20
20
0
- 25
-20
-10
0
20
40
55
70
60
80
0
85
100
(100) (120)
100
Ambient Temperature º C
240
(320)
264
(350)
Input Voltage VAC (VDC)
Typical application circuits
FUSE
2A/300V
Single Output
NTC
+ Vout
AC L
AC L
MOV
S14K350
AC N
AC
+ Vout
C1
C2
1µF/50V
AC N
Earth/GND
FUSE
2A/300V
‐ Vout
Dual Output
AC L
MOV
S14K350
AC
+ Vout
DC
Com
C1
1µF/50V
C3
1µF/50V
AC N
Earth/GND
www.aimtec.com
‐ Vout
NTC
AC L
AC N
TVS
+
DC
‐ Vout
C2
+ Vout
+
TVS 1
C4
+
Com
TVS 2
‐ Vout
Tel: +1 514 620 2722
Toll free: + 1 888 9 AIMTEC
(924
6832)
F 052e R8.A
4 of 5
North America only
Series AME15-CJZ
15 Watt | AC-DC / DC-DC Converter
FUSE
2A/300V
Asymmetric
Dual Output
NTC
+
AC L
AC L
Vout 1
MOV
S14K350
AC N
C1
1µF/50V
‐
DC +
AC
AC N
Vout 2
Earth/GND
C3
1µF/50V
C2
+ Vout 1
+
TVS 1
C4
‐ Vout 1
+ Vout 2
+
TVS 2
‐
FUSE
2A/300V
‐ Vout 2
Triple Output
NTC
+
AC L
AC L
Vout 1
MOV
S14K350
C1
1µF/50V
C2
+
+
TVS1
‐
‐
AC N
AC N
AC
Earth/GND
+ Vout 2
DC
C5
1µF/50V
Com
C3
1µF/50V
C6
+ Vout 2
+
TVS2
C4
Com
+
TVS3
‐ Vout 2
‐ Vout 2
Model
Single 3.3 & 5 Vout
Single 9 Vout
Single 12 & 15 Vout
Single 24 Vout
Dual ±5 Vout
Dual ±12 Vout
Dual ±15 Vout
Dual ±24 Vout
Triple 5/±5 Vout
Triple 5/±12 Vout
Triple 5/±15 Vout
Triple 5/±24 Vout
Dual 5/5 Vout
Dual 5/12 Vout
Dual 5/15 Vout
Dual 5/24 Vout
C2
680 µF
470 µF
220 µF
68 µF
470 µF
220 µF
120 µF
68 µF
470 µF
470 µF
470 µF
470 µF
470 µF
470 µF
470 µF
470 µF
C4
470 µF
220 µF
120 µF
68 µF
220 µF
120 µF
120 µF
120 µF
470 µF
220 µF
120 µF
47 µF
Vout 1
C6
220 µF
120 µF
120 µF
120 µF
-
TVS1
7V
12V
20V
30V
7V
20V
20V
30V
7V
7V
7V
7V
7V
7V
7V
7V
TVS2
7V
20V
20V
30V
7V
20V
20V
30V
7V
20V
20V
30V
TVS3
7V
20V
20V
30V
-
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
Tel: +1 514 620 2722
Toll free: + 1 888 9 AIMTEC
(924
6832)
F 052e R8.A
5 of 5
North America only
Similar pages