F3000TERU Series Compact, 4:1 Input 30W, Triple Output DC/DC Converters Electrical Specifications Key Features: • 30W Output Power • 4:1 Input Voltage Range • 1,500 VDC Isolation • Triple Outputs • Compact 1.6 x 2 In. Case • -40ºC to +85ºC Operation • >1.0 MHour MTBF • Remote ON/OFF • Industry Standard Pin-Out Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Under Voltage Shutdown Input Filter, See Note 1 Input Reflected Ripple Current Start Up Time Typ. 24.0 48.0 Max. 36.0 75.0 9.0 17.8 30 10 Units VDC VDC mA mS Output Parameter Conditions Output Voltage Accuracy Single & Dual Output Models Available F3000ERU Series Conditions Min. 24 VDC Input 9.0 48 VDC Input 18.0 24 VDC Input 8.0 48 VDC Input 16.0 (Pi) Filter Line Regulation, For VIN Min to Max Load Regulation, IOUT = 10% to 100% Ripple & Noise, See Note 2 Output Power Protection Transient Recovery Time, See Note 3 Transient Response Deviation Temperature Coefficient Output Short Circuit Min. Main Output Auxiliary Outputs Main Output Auxiliary Outputs Main Output Auxiliary Outputs Typ. ±1.0 ±3.0 85 130 300 25% Load Step Change ±3.0 ±0.03 Continuous (Autorecovery) Max. ±3.0 ±5.0 ±1.0 ±5.0 ±2.0 ±5.0 120 110 500 ±5.0 Units % % % mV P - P % µSec % %/°C General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Remote On/Off (Note 4) Parameter Supply On Supply Off Standby Input Current Control Common Conditions 60 Seconds 500 VDC 100 kHz, 0.1V Conditions Min. 1,500 1,000 Typ. Max. 2,000 400 Min. 3.5 -0.0 Typ. Min. -40 Typ. Units VDC M⍀ pF kHz Max. Units 12.0 VDC 1.2 VDC 1 mA Referenced to Negative Input (pin 2) Environmental Parameter Conditions Operating Temperature Range MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Ambient Case -55 Free Air Convection RH, Non-condensing Max. +85 +105 +125 Units °C °C °C 95 % 2.0 x 1.6 x 0.42 Inches (50.8 x 40.6 x 11.8 mm) Metal with Non-Conductive Base 1.76 Oz (50g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1,000 Typ. Max. Units kHours Min. -0.7 -0.7 Typ. Max. 40.0 80.0 300 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Model Number F3001TERU F3002TERU F3003TERU F3004TERU F3011TERU F3012TERU F3013TERU F3014TERU Voltage (VDC) Nom. Range 24 9 - 36 24 9 - 36 24 9 - 36 24 9 - 36 48 18 - 75 48 18 - 75 48 18 - 75 48 18 - 75 Input Output 1 Current (mA) Voltage Current Current Full-Load No-Load (VDC) (A, Max) (A, Min) 1,450 30 3.3 3.500 0.175 1,450 30 3.3 3.500 0.175 1,420 30 5.0 3.000 0.150 1,420 30 5.0 3.000 0.150 720 30 3.3 3.500 0.175 720 30 3.3 3.500 0.175 712 30 5.0 3.000 0.150 712 30 5.0 3.000 0.150 Outputs 2/3 OVP (VDC) 3.90 3.90 6.20 6.20 3.90 3.90 6.20 6.20 Voltage Current Current OVP (VDC) (A, Max) (A, Min) (VDC) ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 ±0.625 ±0.500 ±0.625 ±0.500 ±0.625 ±0.500 ±0.625 ±0.500 ±0.031 ±0.025 ±0.031 ±0.025 ±0.031 ±0.025 ±0.031 ±0.025 ±15.0 ±18.0 ±15.0 ±18.0 ±15.0 ±18.0 ±15.0 ±18.0 Efficiency (Typ %) Fuse Rating Slow-Blow (mA) 85 86 88 88 85 85 88 87 2,500 2,500 2,500 2,500 2,000 2,000 2,000 2,000 Derating Curves For Heatsink Option, add suffix “H” to model number (i.e. F3003ERU-H) Notes: 1. With the addition of a simple external circuit, the units will pass VOUT Output Cap. EN 55022 and EN 61000 EMI specifications. Contact the factory 3.3 VDC 10 µF for recommendations. 5 VDC 10 µF 2. When measuring output ripple, it is recommended that an ±4.7 µF external ceramic capacitor (see table at right) be placed from ±12 VDC ±4.7 µF the +Vout pin to the -Vout pin for single output units and from ±15 VDC each output to common for dual output units. 3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 4. The Remote On/Off Control input (Pin 4) is referenced to -Vin (Pin 2). This input may be tied directly to ground, but it is recommended that connection to the pin should be made through a 1k⍀ resistor and diode (1N4148). If it is not used, the control pin should be left open. 5. Operation at no-load will not damage these units. However, they may not meet all specifications. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Mechanical Dimensions Heatsink Dimensions (Optional) Pin Connections MicroPower Direct Pin Function 1 +VIN 2 -VIN 4 ON/OFF 5 +VOUT2 6 +VOUT1 7 -VOUT1 8 -VOUT2 Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]