Philips Semiconductors Preliminary specification Three quadrant triacs high commutation GENERAL DESCRIPTION Glass passivated high commutation triacs in a plastic envelope suitable for surface mounting intended for use in circuits where high static and dynamic dV/dt and high dI/dt can occur. These devices will commutate the full rated rms current at the maximum rated junction temperature, without the aid of a snubber. PINNING - SOT404 PIN BTA212B series C QUICK REFERENCE DATA SYMBOL PARAMETER MAX. MAX. MAX. UNIT BTA212B- 500C Repetitive peak off-state 500 voltages RMS on-state current 12 Non-repetitive peak on-state 95 current VDRM IT(RMS) ITSM PIN CONFIGURATION 600C 600 800C 800 V 12 95 12 95 A A SYMBOL DESCRIPTION mb 1 main terminal 1 2 main terminal 2 3 gate mb T2 T1 2 main terminal 2 1 G 3 LIMITING VALUES Limiting values in accordance with the Absolute Maximum System (IEC 134). SYMBOL PARAMETER VDRM Repetitive peak off-state voltages IT(RMS) RMS on-state current ITSM Non-repetitive peak on-state current I2t dIT/dt IGM VGM PGM PG(AV) Tstg Tj I2t for fusing Repetitive rate of rise of on-state current after triggering Peak gate current Peak gate voltage Peak gate power Average gate power CONDITIONS MIN. - full sine wave; Tmb ≤ 99 ˚C full sine wave; Tj = 25 ˚C prior to surge t = 20 ms t = 16.7 ms t = 10 ms ITM = 20 A; IG = 0.2 A; dIG/dt = 0.2 A/µs over any 20 ms period Storage temperature Operating junction temperature MAX. -500 5001 -600 6001 UNIT -800 800 V - 12 A - 95 105 45 100 A A A2s A/µs - 2 5 5 0.5 A V W W -40 - 150 125 ˚C ˚C 1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 15 A/µs. October 1997 1 Rev 1.000 Philips Semiconductors Preliminary specification Three quadrant triacs high commutation BTA212B series C THERMAL RESISTANCES SYMBOL PARAMETER Rth j-mb Thermal resistance full cycle junction to mounting base half cycle Thermal resistance in free air junction to ambient Rth j-a CONDITIONS MIN. TYP. MAX. UNIT - 60 1.5 2.0 - K/W K/W K/W MIN. TYP. MAX. UNIT T2+ G+ T2+ GT2- G- 2 2 2 - 35 35 35 mA mA mA T2+ G+ T2+ GT2- G- 0.25 - 1.3 0.7 0.4 0.1 20 30 20 15 1.6 1.5 0.5 mA mA mA mA V V V mA STATIC CHARACTERISTICS Tj = 25 ˚C unless otherwise stated SYMBOL PARAMETER CONDITIONS 2 IGT Gate trigger current IL Latching current IH VT VGT Holding current On-state voltage Gate trigger voltage ID Off-state leakage current VD = 12 V; IT = 0.1 A VD = 12 V; IGT = 0.1 A VD = 12 V; IGT = 0.1 A IT = 17 A VD = 12 V; IT = 0.1 A VD = 400 V; IT = 0.1 A; Tj = 125 ˚C VD = VDRM(max); Tj = 125 ˚C DYNAMIC CHARACTERISTICS Tj = 25 ˚C unless otherwise stated SYMBOL PARAMETER CONDITIONS MIN. TYP. UNIT dVD/dt Critical rate of rise of off-state voltage Critical rate of change of commutating current Gate controlled turn-on time VDM = 67% VDRM(max); Tj = 125 ˚C; exponential waveform; gate open circuit VDM = 400 V; Tj = 125 ˚C; IT(RMS) = 12 A; without snubber; gate open circuit ITM = 12 A; VD = VDRM(max); IG = 0.1 A; dIG/dt = 5 A/µs 1000 - V/µs 3 14 A/ms - 2 µs dIcom/dt tgt 2 Device does not trigger in the T2-, G+ quadrant. October 1997 2 Rev 1.000 Philips Semiconductors Preliminary specification Three quadrant triacs high commutation BTA212B series C MECHANICAL DATA Dimensions in mm 4.5 max 1.4 max 10.3 max Net Mass: 1.4 g 11 max 15.4 2.5 0.85 max (x2) 0.5 2.54 (x2) Fig.1. SOT404 : centre pin connected to mounting base. Notes 1. Epoxy meets UL94 V0 at 1/8". MOUNTING INSTRUCTIONS Dimensions in mm 11.5 9.0 17.5 2.0 3.8 5.08 Fig.2. SOT404 : minimum pad sizes for surface mounting. Notes 1. Plastic meets UL94 V0 at 1/8". October 1997 3 Rev 1.000 Philips Semiconductors Preliminary specification Three quadrant triacs high commutation BTA212B series C DEFINITIONS Data sheet status Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications. Limiting values Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of this specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. Philips Electronics N.V. 1997 All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. October 1997 4 Rev 1.000