Online data sheet C4P-SA19530A001000, C4PEA19530A001000 deTec4 Prime SAFETY LIGHT CURTAINS C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS A B C D E F Ordering information System part Type Part no. Sender C4P-SA19530A001000 1215775 C4P-EA19530A001000 1215776 Receiver Other models and accessories www.sick.com/deTec4_Prime Detailed technical data Features H I J K L M N O P Q R S T System part Sender/receiver pair with system plug and QuickFix bracket Usage As a standalone system and as last system in a cascade Resolution 30 mm Protective field height 1,950 mm Scanning range Minimum 0.15 m ... 24 m Typical 0.15 m ... 30 m Response time 14 ms 1) No blind zones ✔ Synchronization Optical synchronisation 1) , without beam coding, no cascaded systems. Other response times see operating instructions. Safety-related parameters Type Type 4 (IEC 61496) Safety integrity level SIL3 (IEC 61508) SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) Single device 9.6 x 10-9 (EN ISO 13849) Cascade with one guest 1.9 x 10-8 (EN ISO 13849) Cascade with two guest devices 2.9 x 10-8 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. 2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-21 16:38:06 Subject to change without notice C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS Functions Functions Delivery status Restart interlock ✔ Deactivated External device monitoring (EDM) ✔ Deactivated Beam coding ✔ Uncoded Automatic calibration of the protective field ✔ width Interfaces System connection Connection type Male connector M12, 5-pin Flexi-Loop-ready ✔ Sender/receiver communication (COM1) ✔ 1) Permitted cable length Receiver power supply: 15 m 2) All additional conductors at the system connection: 37.5 m Configuration method Cascade Automatic detection when starting the device External device monitoring (EDM) Automatic detection when starting the device Calibration of the protective field width Automatic detection when starting the device Restart interlock Teach-in procedure when starting the device Beam coding DIP switch Reset to factory default DIP switch Status display LEDs Fieldbus, industrial network Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 3) 1) 2) 3) Optional: To indicate the status on both sides, the COM1 connections from the sender and receiver must be connected to each other in the control cabinet. If no inductive OSSD loads (e.g., contactors) are in use, the power supply cable for the receiver of a single device (no cascade) can be up to 30 m in length. For additional information on Flexi Soft -> www.sick.com/Flexi_Soft. Electrical data Protection class III (EN 50178) 1) Supply voltage VS 24 V DC (19.2 V DC ... 28.8 V DC) Ripple ≤ 10 % 2) Power consumption typical 3.96 W (DC) / 2.05 W (DC) (depending on type) Safety outputs (OSSD) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS) Switching voltage LOW ≤ 2 V DC Switching current ≤ 500 mA 1) 2) 3) SELV/PELV safety/protective extra-low voltage. Within the limits of VS. Applies to the voltage range between –30 V and +30 V. 2017-08-21 16:38:06 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3 C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS A B C D E F H I J K L M N O P Q R S T Mechanical data Housing cross-section (incl. system connection) 34 mm x 41.1 mm Housing material Aluminum extruded profile Front screen material Polycarbonate, scratch-resistant coating Ambient data Enclosure rating IP65 (EN 60529) IP67 (EN 60529) Ambient operating temperature –30 °C ... +55 °C Storage temperature –30 °C ... +70 °C Air humidity 15 % ... 95 %, Non-condensing Vibration resistance 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Shock resistance 10 g, 16 ms (EN 60068-2-29) Other information Wave length 850 nm Integrated laser alignment aid ✔ Light source Laser diode Laser class 1 (IEC 60825-1) Type of light Visible red light Wave length 650 nm Classifications ECl@ss 5.0 27272704 ECl@ss 5.1.4 27272704 ECl@ss 6.0 27272704 ECl@ss 6.2 27272704 ECl@ss 7.0 27272704 ECl@ss 8.0 27272704 ECl@ss 8.1 27272704 ECl@ss 9.0 27272704 ETIM 5.0 EC002549 ETIM 6.0 EC002549 UNSPSC 16.0901 46171620 4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-21 16:38:06 Subject to change without notice C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS Dimensional drawing (Dimensions in mm (inch)) 30.7 21.8 (0.86) 30 (1.18) 13.8 (0.54) 56.8 (2.24) (1.21) 29.5 5 (0.2) 14 (0.55) L (1.16) 34 30.7 (1.21) 41.1 (1.62) 56.8 (2.24) 21.8 (0.86) 56.8 (2.24) 13.8 (0.54) 4 (0.16) (2.24) 56.8 (1.34) L 2017-08-21 16:38:06 | Online data sheet Subject to change without notice 300 313 450 463 600 613 750 763 900 913 1,050 1,063 1,200 1,213 1,350 1,362 1,500 1,512 1,650 1,662 1,800 1,812 1,950 1,962 2,100 2112 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5 C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS A B C D E F Connection diagram deTec4 Prime safety light curtain to UE10-3OS safety relay +24 V r 2 +24 V +24 V 2 3 n.c RES 1 4 n.c. EDM 4 5 In2 OSSD1 5 In1 OSSD2 6 n.c. ADO 3 0V 0V 7 Com1 8 6 1 7 8 Com1 deTec4 Prime H I J K L M N O P Q R S T S1 s B1 B3 2) Y1 13 23 33 41 1) UE10-3OS B2 B4 Y2 14 24 34 42 H2 0V E132908/00/2015-04-07 3) PELV ① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only possible with a single-channel control and taking the risk analysis into account. ② To indicate the status on both sides, the Com1 connections from the sender and receiver must be connected to each other in the control cabinet (optional). ③ SELV/PELV safety/protective extra-low voltage. 6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-21 16:38:06 Subject to change without notice C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS deTec4 Prime safety light curtain cascade to UE10-3OS safety relay +24 V s 1 2 3 4 5 6 7 8 r RES n.c. +24 V +24 V n.c. ADO n.c. OSSD1 In2 OSSD2 In1 EDM 0V 0V Com1 Com1 1 2 3 5 6 4 7 8 3) B1 B3 Y1 13 23 33 41 Y2 14 24 34 42 1) 2) UE10-3OS B2 B4 deTec4 Prime 0V 4) PELV E132954/00/2015-04-07 ① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only possible with a single-channel control and taking the risk analysis into account. ② Connection of the 5-pin extension connection of the host device to the 5-pin system connection of the guest device. ③ To indicate the status on both sides, the Com1 connections from the sender and receiver must be connected to each other in the control cabinet (optional). ④ SELV/PELV safety/protective extra-low voltage. 2017-08-21 16:38:06 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7 C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS deTec4 Prime safety light curtain with T-connector to UE48-2OS safety relay +24 V 1 2 4 3 5 4 3 3 5 5 r +24 V +24 V In2 OSSD1 In1 OSSD2 0V 0V Com1 Com1 1) x y k1 k2 x y z k1 5 4 3 2 4 1 2 2 s 1 1 A B C D E F k2 1 z 2 4 3 S1 S33 S11 S12 S31 A1 13 23 31 5 k1 UE48-2OS2D2 deTec4 Prime S34 S35 S21 S22 A2 14 24 32 k2 H I J K L M N O P Q R S T 2) K1 K2 0V 3) PELV E132906/00/2015-04-07 ① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only possible with a single-channel control and taking the risk analysis into account. ② External device monitoring is only static. ③ SELV/PELV safety/protective extra-low voltage. Task Connection of a deTec4 Prime safety light curtain to a UE48-2OS safety relay. Operating mode: with restart interlock and external device monitoring (EDM). The T-piece establishes a connection between the sender and the receiver. Mode of operation When the protective field is clear, the OSSD1 and OSSD2 outputs carry voltage. The system can be switched on when K1 and K2 are in a fault-free de-energized position. The UE48-2OS is switched on by pressing S1 (pushbutton is pressed and released). The outputs (contacts 13-14 and 23-24) switch the K1 and K2 contactors on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch the UE48-2OS off. Contactors K1 and K2 are switched off. Fault analysis Cross-circuits and short-circuits of the OSSD1 and OSSD2 outputs are recognized and lead to the locking state (lock-out). A malfunction with one of the K1 or K2 contactors is detected. The shut-down function is retained. In the event of manipulation (e.g., jamming) of the S1 pushbutton, the UE48-2OS will not re-enable the output current circuits. Task Connection of two deTec4 Prime safety light curtains to a UE10-3OS safety relay. Operating mode: without restart interlock, with external device monitoring (EDM). If required, the restart interlock is implemented via the machine controller. Mode of operation If the protective field is clear and the UE10-3OS is in a fault-free de-energized position, the system is enabled. Outputs OSSD1 and OSSD2 carry voltage, the UE10-3OS is switched on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch the UE10-3OS off. Fault analysis Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). The malfunction of the UE10-3OS is detected. The shut-down function is retained. Task Connection of a deTec4 Prime safety light curtain to a UE10-3OS safety relay. Operating mode: with restart interlock, external device monitoring (EDM), and application diagnostic output. Mode of operation 8 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-21 16:38:06 Subject to change without notice C4P-SA19530A001000, C4P-EA19530A001000 | deTec4 Prime SAFETY LIGHT CURTAINS If the protective field is clear and the UE10-3OS is in a fault-free de-energized position, the field indicator and the H2 lamp flash. The system can be switched on. The system is enabled by pressing S1 (pushbutton is pressed and released). Outputs OSSD1 and OSSD2 carry voltage, the UE10-3OS is switched on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch the UE10-3OS off. Fault analysis Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). The malfunction of the UE10-3OS is detected. The shut-down function is retained. Manipulation (e.g., jamming) of the S1 pushbutton prevents the output circuits from being enabled. 2017-08-21 16:38:06 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 9 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com