SYNERGY FBS-140 Band pass filter Datasheet

band pass filter
surface mount MODEL: fBs-140
Fc = 140 MHz
optimized frequency
FEATURES:
► High Rejection
► Small Size
► Optimum Performance
0.0
APPLICATIONS:
► Transceiver IF Filter
► Wireless Communications
► Commercial & Military Systems
Passband Insertion Loss (dB)
0.5
1.0
1.5
2.0
2.5
3.0
136
137
138
139
140
141
142
143
144
Frequency (MHz)
SPECIFICATIONS (Rev. A 10/19/07)
Center Frequency
140 MHz
Insertion Loss
5 dB (Max.)
1 dB Ripple Bandwidth
8 MHz
20 dB Bandwidth
120 - 160 MHz
40 dB Bandwidth
108 - 178 MHz
Input Power
1 Watt (Max.)
Impedance
50 Ohms (Nom.)
Operating Temperature Range
-40 to +85 °C
Package #
124S
PORT CONFIGURATION
Copyright © Synergy Microwave Corporation
201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361
E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com
Input
Output
Gnd.
1
16
All Other
[ 1 of 3 ]
band pass filter
surface mount MODEL: fBs-140
Fc = 140 MHz
optimized frequency
10
Stopband Rejection (dB)
20
30
40
50
60
70
80
90
40
65
90
115
140
165
190
215
240
141
142
143
144
Frequency (MHz)
0
5
Return Loss (dB)
10
15
20
25
30
35
40
136
137
138
139
140
PERFORMANCE PLOTS
0
Frequency (MHz)
S11 (Passband)
S22 (Passband)
Copyright © Synergy Microwave Corporation
201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361
E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com
[ 2 of 3 ]
band pass filter
surface mount MODEL: fBs-140
Fc = 140 MHz
optimized frequency
Passband Insertion Phase (deg.)
-75
-100
-125
-150
-175
-200
-225
-250
136
137
138
139
140
141
142
143
144
142
143
144
Frequency (MHz)
60
Group Delay (nSec)
50
40
30
20
10
0
136
137
138
139
140
141
PERFORMANCE PLOTS
-50
Frequency (MHz)
Copyright © Synergy Microwave Corporation
201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361
E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com
[ 3 of 3 ]
Similar pages