AN4165 Application note STEVAL-ISA111V1: 12 V/12 W, 115 kHz non-isolated flyback based on the VIPER26 By Mirko Sciortino Introduction This document describes a 12 V - 1 A power supply set in non-isolated flyback topology based on the VIPER26, an offline high-voltage converter offered by STMicroelectronics. The features of the device include: ■ 800 V avalanche rugged power section ■ PWM operation at 115 kHz with frequency jittering for lower EMI ■ Limiting current with adjustable set point ■ On-board soft-start ■ Safe behavior during a fault condition (overload, short-circuit, open loop) ■ Low standby consumption (< 30 mW at VIN = 230 VAC) The available protections are: ■ Thermal shutdown with hysteresis ■ Delayed overload (or short-circuit) protection ■ Open loop failure protection All protections employ the auto-restart mode. Figure 1. February 2013 STEVAL-ISA111V1 demonstration board Doc ID 023661 Rev 1 1/37 www.st.com Contents AN4165 Contents 1 Adapter features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Circuit description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3 Bill of material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4 Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5 Testing the board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5.1 Typical waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 6 Line/load regulation and output voltage ripple . . . . . . . . . . . . . . . . . . 13 7 Burst mode and output voltage ripple . . . . . . . . . . . . . . . . . . . . . . . . . . 15 8 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 9 Light-load performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 10 Functional check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 11 10.1 Soft-start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 10.2 Overload protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 10.3 Feedback loop failure protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Feedback loop calculation guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 24 11.1 Transfer function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 11.2 Compensation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 12 Thermal measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 13 EMI measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 14 Board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 15 Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2/37 Doc ID 023661 Rev 1 AN4165 Contents Appendix A Test equipment and measurement of efficiency and light load performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 A.1 Measuring input power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 16 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 17 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Doc ID 023661 Rev 1 3/37 List of figures AN4165 List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. Figure 30. Figure 31. Figure 32. Figure 33. Figure 34. Figure 35. Figure 36. Figure 37. Figure 38. Figure 39. Figure 40. Figure 41. Figure 42. Figure 43. Figure 44. Figure 45. Figure 46. Figure 47. 4/37 STEVAL-ISA111V1 demonstration board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Application schematic - complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Application schematic - simplified for VOUT ≥ 12 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Transformer size and pin diagram, bottom view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Transformer size, side view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Transformer, pin distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Transformer, electrical diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Drain current and voltage at VIN = 115 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Drain current and voltage at VIN = 230 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Drain current and voltage at VIN = 90 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Drain current and voltage at VIN = 265 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Line regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Load regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Output voltage ripple at VIN = 115 VAC, full load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Output voltage ripple at VIN = 230 VAC, full load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Output voltage ripple at VIN = 115 VAC, no load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Output voltage ripple at VIN = 230 VAC, no load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Output voltage ripple at VIN = 115 VAC, IOUT = 25 mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Output voltage ripple at VIN = 230 VAC, IOUT = 25 mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Active mode efficiency of the demonstration board in comparison to energy efficiency standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 PIN vs. VIN at no load and light load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Efficiency vs. VIN at PIN = 1 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 PIN at POUT = 0.25 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Soft-start at startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Soft-start at startup (zoom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Output short-circuit applied: OLP tripping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Output short-circuit maintained: OLP steady-state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Output short-circuit maintained: OLP steady-state, zoom . . . . . . . . . . . . . . . . . . . . . . . . . 22 Output short-circuit removal and converter restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Feedback loop failure protection: tripping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Feedback loop failure protection: steady-state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Feedback loop failure protection: steady-state, zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Feedback loop failure removal: converter restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Control loop block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Thermal map at TAMB = 25 °C, VIN = 85 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Thermal map at TAMB = 25 °C, VIN = 115 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Thermal map at TAMB = 25 °C, VIN = 230 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Thermal map at TAMB = 25 °C, VIN = 265 VAC, full load . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Background noise measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Peak measurement at 115 VAC/full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Peak measurement at 230 VAC/full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Average measurement at 115 VAC/full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Average measurement at 230 VAC/full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Bottom layer & top overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Connections of the UUT to the wattmeter for power measurements . . . . . . . . . . . . . . . . . 32 Switch in position 1 - setting for standby measurements . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Switch in position 2 - setting for efficiency measurements . . . . . . . . . . . . . . . . . . . . . . . . . 33 Doc ID 023661 Rev 1 AN4165 List of tables List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Electrical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Bill of material (simplified schematic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Transformer characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Output voltage line-load regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Output voltage ripple at half and full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Output voltage ripple at no (or light) load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 No load input power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Energy consumption criteria for no load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Light load performance at POUT = 25 mW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Light load performance at POUT = 50 mW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 POUT @ PIN = 1 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Temperature of key components at VIN = 85 VAC /230 VAC, full load (TAMB = 25 ×C) . . . 27 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Doc ID 023661 Rev 1 5/37 Adapter features 1 AN4165 Adapter features The electrical specifications of the demonstration board are listed in Table 1. Table 1. Electrical specifications Symbol VIN Parameter Value [ 90 VAC - 265 VAC] Input voltage range VOUT Output voltage 12 V IOUT Max. output current 1A Δ VOUT_LF Precision of output regulation ± 5% Δ VOUT_HF High-frequency output voltage ripple 50 mV TAMB Max. ambient operating temperature 60 oC 6/37 Doc ID 023661 Rev 1 AN4165 2 Circuit description Circuit description The power supply is set in flyback topology. The complete schematic is given in Figure 2. A simplified schematic for VOUT ≥12 V and the relevant BOM are given in Figure 3 and in Table 2 respectively. The input section includes a resistor R1 and an NTC for inrush current limiting, a diode bridge (D0) and a Pi filter for EMC suppression (C1, L2, C2). The transformer core is a standard E20. A Transil™ clamp network (D1, D4) is used for leakage inductance demagnetization. The output voltage value is set simply through the R3-R4 voltage divider between the output terminal and the FB pin, according to the following formula: Equation 1 R3 ⎞ ⎛ VOUT = 3.3V ⋅ ⎜ 1 + ⎟ ⎝ R4 ⎠ In fact, the FB pin is the input of an error amplifier and is an accurate 3.3 V voltage reference. In the schematic the resistor R4 has been split into R4a and R4b in order to allow better tuning of the output voltage value. The compensation network is connected between the COMP pin (which is the output of the error amplifier) and the GND pin and consists of C7, C8 and R7. The output rectifier D3 has been selected according to the calculated maximum reverse voltage, forward voltage drop and power dissipation and is a power Schottky. A resistor has been connected between the LIM and GND pins in order to reduce the IDLIM to the value needed to supply the required output power, limiting the stress on the power components. At power-up the DRAIN pin supplies the internal HV startup current generator which charges the VDD capacitor, C4, up to VDDon. At this point, the Power MOSFET starts switching, the generator is turned off and the IC is powered by the energy stored in C4. If the nominal value of VOUT exceeds the VDDcson threshold of the VIPER26 by a small signal diode forward voltage drop, the IC can be supplied directly from the output, selecting jumper J2 which is shown as open in Figure 2 (ie. no selection of either jumper J1 or J2 is indicated). In this case jumper J1 is open because the auxiliary winding of the transformer is not needed and the schematic can be simplified, as shown in Figure 3. Since VDDcsonmax = 11.5 V, the minimum value of VOUT allowing this connection is 12 V. If VOUT < 12 V, the VIPER26 must be supplied through the auxiliary winding of the transformer (J1 selected, J2 open in Figure 2), delivering to the VDD pin a voltage higher than VDDcson. The voltage generated by the auxiliary winding increases with the load on the regulated output. An external clamp (D5, R1) can be added in this case, in order to avoid exceeding the VDD operating range. The figures and measurements in this document refer to a case in which VDD is supplied from the output, i.e. to the simplified schematic shown in Figure 3. Doc ID 023661 Rev 1 7/37 Application schematic - complete NTC T1 L2 t AC IN Circuit description 8/37 Figure 2. 5 D0 - + C1 C2 + D4 + C9 D3 F VOUT L1 6,7 AC IN D1 C10 + 3 C11 + C12 + GROUND 1 8,9 Doc ID 023661 Rev 1 R2 D2 J1 2 J2 VDD R3 D6 DRAIN R1 FB VIPER26 CONTROL R4a IC1 C4 COMP + C6 C5 R4b D5 LIM GND C7 C8 R5 R7 AN4165 AM11547v1 Application schematic - simplified for VOUT ≥ 12 V AN4165 Figure 3. T2 NTC L2 t AC IN 5 D0 D4 - + C1 C2 + + VOUT D3 F 6,7 AC IN D1 C10 + 3 C11 + GROUND 1 8,9 Doc ID 023661 Rev 1 3 D6 C4 + C5 VDD R3 FB DRAIN VIPER26 CONTROL R4a COMP C6 LIM GND R4b C8 R5 R7 9/37 AM11548v1 Circuit description C7 Bill of material AN4165 3 Bill of material Table 2. Bill of material (simplified schematic) Reference Part NTC 2.2 Ω NTC Thermistor, S236 series F T2A 250 V 2 A, 250 VAC fuse, TR5 series Wickmann C1 10 µF, 400 V NHG series electrolytic capacitor Panasonic C2 22 µF, 35 V SMG series electrolytic capacitor Panasonic C4 2.2 µF, 63 V electrolytic capacitor C5 100 nF, 50 V ceramic capacitor C6 2.2 nF, 50 V ceramic capacitor C7 100 nF, 50 V ceramic capacitor C8 2.2 nF, 50 V ceramic capacitor C9 10/37 Description Manufacturer EPCOS Not mounted C10 1000 µF, 16 V ultra low ESR electrolytic capacitor ZL series Rubycon C11 680 µF, 16 V ultra low ESR electrolytic capacitor ZL series Rubycon C12 Not mounted D0 DF06M D1 STTH1L06 D2 Not mounted D3 1 A - 600 V diode bridge Vishay 1 A - 600 V ultrafast diode ST STPS3150 3 A-150 V power Schottky (output diode) ST D4 1.5KE300A Transil ST D5 Not mounted D6 1N4148 R1 Not mounted R2 Not mounted Small signal diode R3 47 k Ω 1% 1/4 W resistor R4a 15 k Ω 1% 1/4 W resistor R4b 2.7 k Ω 1% 1/4 W resistor R5 27 k Ω 1/4 W resistor R7 33 k Ω 1/4 W resistor L1 Short-circuit L2 RFB0807-102 T1 1335.0089 IC1 VIPER26HN High-voltage 115 kHz PWM J1 Not mounted Jumper J2 Short-circuit Jumper Input filter inductor (L = 1 mH, ISAT = 0.3 A; DCRmax = 3.4 Ω) 115 kHz switch mode transformer Doc ID 023661 Rev 1 Fairchild Coilcraft Magnetica ST AN4165 4 Transformer Transformer The characteristics of the transformer are listed in the table below. Table 3. Transformer characteristics Parameter Value Test conditions Manufacturer Magnetica Part number 1335.0089 Primary inductance 1.8 mH ±15% Measured at 1 kHz, TAMB = 20 oC Leakage inductance 3.12% Measured at 10 kHz, TAMB = 20 oC Primary to secondary turn ratio (3 - 5)/(6,7- 8,9) 5.8 ± 5% Measured at 10 kHz, TAMB = 20 oC Primary to auxiliary turn ratio (3 - 5)/(1 - 2) 5.8 ± 5% Measured at 10 kHz, TAMB = 20 oC The figures below show the size, pinout, and pin distances (in mm) as well as the electrical diagram of the transformer. Figure 4. Transformer size and pin diagram, bottom view Figure 5. AM13359v1 Figure 6. Transformer, pin distances Transformer size, side view AM13360v1 Figure 7. AM13361v1 Doc ID 023661 Rev 1 Transformer, electrical diagram AM11552v1 11/37 Testing the board AN4165 5 Testing the board 5.1 Typical waveforms Drain voltage and current waveforms in full load condition are shown for the two nominal input voltages in Figure 8 and 9, and for minimum and maximum input voltage in Figure 10 and 11 respectively. Figure 8. Figure 9. Drain current and voltage at VIN = 115 VAC, full load Drain current and voltage at VIN = 230 VAC, full load AM13362v1 Figure 10. Drain current and voltage at VIN = 90 VAC, full load AM13363v1 Figure 11. Drain current and voltage at VIN = 265 VAC, full load AM13364v1 12/37 Doc ID 023661 Rev 1 AM13365v1 AN4165 Line/load regulation and output voltage ripple 6 Line/load regulation and output voltage ripple The output voltage of the board has been measured in different line and load conditions. The results are shown in Table 4. The output voltage is practically unaffected by the line condition. Table 4. Output voltage line-load regulation VOUT[V] VIN [VAC] No load 50% load 75% load 100% load 90 11.94 11.91 11.92 11.92 115 11.94 11.91 11.92 11.92 150 11.94 11.92 11.91 11.91 180 11.94 11.92 11.91 11.91 230 11.94 11.92 11.91 11.91 265 11.94 11.92 11.91 11.91 Figure 13. Load regulation 12.1 12.1 12 12 VOUT[V] VOUT[V] Figure 12. Line regulation 11.9 0 11.9 90 25% 11.8 50% 115 11.8 75% 230 100% 11.7 80 105 130 155 180 VIN[V AC ] 205 230 255 265 11.7 0 AM13366v1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Iout[A] 1 1.1 AM13367v1 The ripple at the switching frequency superimposed at the output voltage has also been measured and the results are given in Table 5. Table 5. Output voltage ripple at half and full load VOUT [mV] VIN [VAC] Half load Full load 90 17 23 115 16 21 230 18 25 265 17 24 Doc ID 023661 Rev 1 13/37 Line/load regulation and output voltage ripple Figure 14. Output voltage ripple at VIN = 115 VAC, full load AN4165 Figure 15. Output voltage ripple at VIN = 230 VAC, full load AM13368v1 14/37 Doc ID 023661 Rev 1 AM13369v1 AN4165 7 Burst mode and output voltage ripple Burst mode and output voltage ripple When the converter is lightly loaded, the COMP pin voltage decreases. As it reaches the shutdown threshold, VCOMPL (1.1 V, typical), the switching is disabled and energy is no longer transferred to the secondary side. So, the output voltage decreases and the regulation loop makes the COMP pin voltage increase again. As it rises 40 mV above the VCOMPL threshold, the normal switching operation is resumed. This results in a controlled on/off operation (referred to as “burst mode”) as long as the output power is low enough to require a turn-on time lower than the minimum turn-on time of the VIPER26. This mode of operation keeps the frequency-related losses low when the load is very light or disconnected, making it easier to comply with energy-saving regulations. The figures below show the output voltage ripple when the converter is not (or lightly) loaded and supplied with 115 VAC and with 230 VAC respectively. Figure 16. Output voltage ripple at VIN = 115 VAC, no load Figure 17. Output voltage ripple at VIN = 230 VAC, no load AM13370v1 Figure 18. Output voltage ripple at VIN = 115 VAC, IOUT = 25 mA AM13371v1 Figure 19. Output voltage ripple at VIN = 230 VAC, IOUT = 25 mA AM13372v1 Doc ID 023661 Rev 1 AM13373v1 15/37 Burst mode and output voltage ripple AN4165 Table 6 shows the measured value of the burst mode frequency ripple measured under different operating conditions. The ripple in burst mode operation is very low. Table 6. Output voltage ripple at no (or light) load VOUT [mV] VIN [VAC] 16/37 No load 25 mA load 90 2 3 115 2 5 230 2 6 265 3 6 Doc ID 023661 Rev 1 AN4165 Efficiency Active mode efficiency is defined as the average of the efficiencies measured at 25%, 50%, 75% and 100% of maximum load, at nominal input voltage (VIN = 115 VAC and VIN = 230 VAC). External power supplies (the power supplies which are housed separately from the end-use devices they are powering) need to comply with the Code of Conduct (version 4.0) "Active mode efficiency" criterion, which requires an active mode efficiency higher than 77.7% for a power throughput of 12 W. Another standard to be applied to external power supplies in the coming years is the DOE (Department of Energy) recommendation, whose active mode efficiency requirement for the same power throughput is 82.96%. The average efficiencies of the board at 115 VAC (83.33%) and at 230 VAC (81.34%) are represented by dotted lines, and, along with the above limits, show that the STEVALISA111V1 demonstration board is compliant with both standards at 115 VAC and with the Code of Conduct only at 230 VAC (refer to Figure 20 below). In the same figure the efficiency at 25%, 50%, 75% and 100% of maximum load for both input voltages is also shown. Figure 20. Active mode efficiency of the demonstration board in comparison to energy efficiency standards 85 83 DOE limit 81 eff [%] 8 Efficiency 79 CoC4 limit 77 115 230 av @ 115Vac av @ 230Vac 75 73 0.2 0.4 0.6 0.8 Iout [% I OUT ] Doc ID 023661 Rev 1 1 AM13375v1 17/37 Light-load performance 9 AN4165 Light-load performance The input power of the converter has been measured in no load condition for different input voltages and the results are given in Table 7. Table 7. No load input power VIN [VAC] PIN [mW] 90 13.4 115 14.4 150 16.1 180 18.0 230 22.2 265 24.9 In version 4.0 of the Code of Conduct the power consumption of the power supply when it is not loaded is also considered. The criteria for compliance are given in the table below: Table 8. Energy consumption criteria for no load Nameplate output power (Pno) Maximum power in no load for AC-DC EPS 0 W ≤Pno ≤50 W < 0.3 W 50 W < Pno < 250 W < 0.5 W The power consumption of the STEVAL-ISA111V1 board is about ten times lower than the Code of Conduct (version 4) limit. Even if this performance seems to be disproportionally better than the requirements, it is worth noting that often AC-DC adapter or battery charger manufacturers have very strict requirements about no load consumption and when the converter is used as an auxiliary power supply, the line filter is often the main line filter of the entire power supply which considerably increases standby consumption. Even if the Code of Conduct (version 4) program does not have other requirements regarding light load performance, in order to give more information the input power and efficiency of the demonstration board in two other light load cases is also shown. Table 9 and Table 10 show the performance when the output load is 25 mW and 50 mW respectively. Table 9. 18/37 Light load performance at POUT = 25 mW VIN [VAC] POUT [mW] PIN [mW] Efficiency (%) 90 25 44.9 55.7 115 25 46.3 54.0 150 25 49.1 50.9 180 25 51.5 48.5 230 25 55.0 45.5 265 25 59.0 42.4 Doc ID 023661 Rev 1 AN4165 Light-load performance Table 10. Light load performance at POUT = 50 mW VIN [VAC] POUT [mW] PIN [mW] Efficiency (%) 90 50 76.7 65.2 115 50 78.5 63.7 150 50 82.0 61.0 180 50 85.0 58.8 230 50 90.0 55.6 265 50 94.0 53.2 The input power vs. input voltage for no load and light load condition (Table 7, 9 and 10) are shown in the figure below. Figure 21. PIN vs. VIN at no load and light load 200 0 175 25mW Pin [mW] 150 50mW 125 100 75 50 25 0 80 105 130 155 180 205 230 255 VIN [VAC] AM11570v1 It’s possible to have several criteria to measure the standby or light load performance of a converter. One criterion is the measurement of the output power when the input power is equal to one watt. In Table 11 the output power needed to have 1 W of input power in different line conditions is given. Figure 22 shows the output power corresponding to PIN = 1 W for different values of the input voltage. Table 11. POUT @ PIN = 1 W VIN [VAC] PIN (W) POUT (W) Efficiency (%) 90 1 0.788 78.8 115 1 0.781 78.1 150 1 0.76 76.0 180 1 0.74 74.0 230 1 0.70 70.0 265 1 0.686 68.6 Doc ID 023661 Rev 1 19/37 Light-load performance AN4165 Figure 22. Efficiency vs. VIN at PIN = 1 W 90 85 80 eff [%] 75 70 65 60 55 50 80 110 140 170 200 VIN [V AC ] 230 260 AM13378v1 Another requirement (EuP lot 6 ) is that the input power should be less than 500 mW when the converter is loaded with 250 mW. The converter can satisfy even this requirement, as shown in Figure 23. Figure 23. PIN at POUT = 0.25 W 0.5 0.45 PIN [W] 0.4 0.35 0.3 0.25 80 110 140 170 Vin[V] 20/37 Doc ID 023661 Rev 1 200 230 260 AM11571v2 AN4165 Functional check 10 Functional check 10.1 Soft-start At startup the current limitation value reaches IDLIM after an internally set time, tSS, whose typical value is 8.5 msec. This time is divided into 16 time intervals, each corresponding to a current limitation step progressively increasing. In this way the drain current is limited during the output voltage increase, therefore reducing the stress on the secondary diode. The softstart phase is shown in Figure 24 and 25. Figure 24. Soft-start at startup Figure 25. Soft-start at startup (zoom) AM13379v1 10.2 AM13380v1 Overload protection In case of overload or short-circuit (see Figure 26), the drain current reaches the IDLIM value (or the one set by the user through the RLIM resistor). Every cycle that this condition is met, a counter is incremented. If the fault is maintained continuously for the time tOVL (50 msec typical, set internally), the overload protection is tripped, the power section is turned off and the converter is disabled for a tRESTART time (1 s typical). After this time has elapsed, the IC resumes switching and, if the short is still present, the protection occurs indefinitely in the same way (Figure 27). This ensures restart attempts of the converter with low repetition rate, so that it works safely with extremely low power throughput and avoids overheating of the IC in case of repeated overload events. Moreover, every time the protection is tripped, the internal soft-start function (Figure 25) is implemented, in order to reduce the stress on the secondary diode. After the short removal, the IC resumes working normally. If the short is removed during tSS or tOVL, i.e. before the protection is tripped, the counter is decremented on a cycle-by-cycle basis down to zero and the protection is not tripped. If the short-circuit is removed during tRESTART, the IC waits for the tRESTART period to elapse before resuming switching (Figure 29). Doc ID 023661 Rev 1 21/37 Functional check AN4165 Figure 26. Output short-circuit applied: OLP tripping Figure 27. Output short-circuit maintained: OLP steady-state Output is shorted here tRESTART Normal operation AM11574v1 Figure 28. Output short-circuit maintained: OLP steady-state, zoom tSS tSS AM11575v1 Figure 29. Output short-circuit removal and converter restart tOVL tOVL tRESTART Normal operation Output short is removed here AM13381v1 10.3 AM11577v1 Feedback loop failure protection When the loop is broken (R4 = R4a + R4b shorted or R3 open), the output voltage VOUT increases and the VIPER26 runs at its maximum current limitation. The VDD pin voltage increases as well, because it is linked to the VOUT voltage either directly or through the auxiliary winding. If the VDD voltage reaches the VDDclamp threshold (23.5 V min.) in less than 50 msec, the IC is shut down by the open loop failure protection (see Figure 30 and 31), otherwise by OLP, as described in the previous section. The breaking of the loop has been simulated by 22/37 Doc ID 023661 Rev 1 AN4165 Functional check shorting the low-side resistor of the output voltage divider, R4 = R4a + R4b. The same behavior can be caused by opening the high-side resistor, R3. The protection acts in auto-restart mode with tRESTART = 1 s (Figure 31). When the fault is removed, normal operation is restored after the last tRESTART interval has been completed (Figure 33). Figure 30. Feedback loop failure protection: Figure 31. Feedback loop failure protection: tripping steady-state Fault is applied here VDD reaches VDDCLAMP < tOVL Normal operation tRESTART AM11578v1 Figure 32. Feedback loop failure protection: steady-state, zoom AM11579v1 Figure 33. Feedback loop failure removal: converter restart Fault is removed here tRESTART Normal operation < tOVL AM11580v1 Doc ID 023661 Rev 1 AM11581v1 23/37 Feedback loop calculation guidelines AN4165 11 Feedback loop calculation guidelines 11.1 Transfer function The set PWM modulator + power stage is indicated with G1(f), while C(f) is the “controller”, i.e. the network which is in charge of ensuring the stability of the system. Figure 34. Control loop block diagram AM11582v1 The mathematical expression of the power plant G1(f) is the following: Equation 2 j ⋅2⋅π ⋅ f j⋅ f VOUT ⋅ (1 + ) VOUT ⋅ (1 + ) ΔVOUT fz z = G 1 (f) = = j ⋅ 2 ⋅π ⋅ f j⋅ f ΔI pk Ipkp ( fsw,Vdc) ⋅ (1 + ) Ipkp ( fsw, Vdc ) ⋅ (1 + ) p fp where VOUT is the output voltage, Ipkp is the primary peak current, fp is the frequency of the pole due to the output load: Equation 3 fp = 1 π ⋅ C OUT ·(R OUT + 2ESR) and fz the frequency of the zero due to the ESR of the output capacitor: Equation 4 fz = 24/37 1 2 ⋅π ⋅ C OUT ·ESR Doc ID 023661 Rev 1 AN4165 Feedback loop calculation guidelines The mathematical expression of the compensator C(f) is: Equation 5 C(f )= ΔI pk ΔV OUT = C0 ⋅ H COMP 1+ f ⋅j fZc ⎛ f ⋅j⎞ 2 ⋅ π ⋅ f ⋅ j ⋅ ⎜⎜1 + ⎟ fPc ⎟⎠ ⎝ where (with reference to the schematic of Figure 2): Equation 6 C0 = − Gm R4 ⋅ C 7 + C 8 R3 + R 4 Equation 7 fZc = 1 2 ⋅ π ⋅ R7 ⋅ C7 Equation 8 fPc = C7 + C 8 2 ⋅ π ⋅ R7 ⋅ C7 ⋅ C8 are to be chosen with the purpose to ensure the stability of the overall system. Gm = 2 mA/V (typical) is the VIPER26 transconductance. 11.2 Compensation procedure The first step is to choose the pole and zero of the compensator and the crossover frequency, for instance: ● fZc = fp/2 ● fPc = fz ● fcross = fcross_sel ≤fsw/10. G1(fcross_sel) can be calculated from Equation 2 and, being by definition | C(fcross_sel)*G1(fcross_sel)| = 1, C0 can be calculated as follows: Equation 9 2 ⋅ π ⋅ fcross _ sel ⋅ j ⋅ 1 + C0 = 1+ fcross _ sel ⋅ j fPc fcross _ sel ⋅ j fZc Doc ID 023661 Rev 1 ⋅ HCOMP G1( fcross _ sel ) 25/37 Feedback loop calculation guidelines AN4165 At this point the Bode diagram of G1(f)*C(f) can be plotted, in order to check the phase margin for the stability. If the margin is not high enough, another choice should be made for fZc, fPc and fcross_sel, and the procedure repeated. When the stability is ensured, the next step is to find the values of the schematic components, which can be calculated using Equation 1, 6, 7, 8, 9 as follows: Equation 10 R3 R 4 = ----------------------V OUT -------------- – 1 3.3V Equation 11 C8 = fZc Gm R4 ⋅ ⋅ fPc C 0 R 4 + R 3 Equation 12 ⎛ fPc ⎞ C7 = C8 ⋅ ⎜⎜ − 1⎟⎟ ⎝ fZc ⎠ Equation 13 R7 = 26/37 C 7 + C8 2 ⋅ π ⋅ fPc ⋅ C7 ⋅ C8 Doc ID 023661 Rev 1 AN4165 Thermal measurements 12 Thermal measurements A thermal analysis of the board at full load condition,@ TAMB = 25 ° C has been performed using an IR camera. The worst case is VIN = 85 VAC, but the nominal input voltage cases (VIN = 115 VAC and VIN = 230 VAC) have also been considered. The results are shown in Figure 35, 36, 37 and 38 and summarized in Table 12. Figure 35. Thermal map at TAMB = 25 ° C, VIN = 85 VAC, full load Figure 36. Thermal map at TAMB = 25 ° C, VIN = 115 VAC, full load AM13383v1 AM13382v1 Figure 37. Thermal map at TAMB = 25 ° C, VIN = 230 VAC, full load Figure 38. Thermal map at TAMB = 25 ° C, VIN = 265 VAC, full load AM13385v1 AM13384v1 Table 12. Temperature of key components at VIN = 85 VAC /230 VAC, full load (TAMB = 25 ° C) T [° C ] Point Reference VIN = 85 VAC VIN = 265 VAC A 82.4 76.6 VIPER26 B 68.3 73.3 Transformer C 69.1 67.0 Output diode D 55.4 53.0 Clamping diode E 24.8 24.9 Room temperature Doc ID 023661 Rev 1 27/37 EMI measurements 13 AN4165 EMI measurements A pre-compliance test to EN55022 (Class B) European normative has been performed using an EMC analyzer and an LISN. First of all, a measurement of the background noise (board disconnected from the mains) was performed and is shown in Figure 39. Then the peak and average EMC measurements at 115 VAC/full load and 230 VAC/full load were performed and the results are shown in Figure 40, 41, 42 and 43. Figure 39. Background noise measurement AM13386v1 Figure 40. Peak measurement at 115 VAC/full load AM13387v1 28/37 Doc ID 023661 Rev 1 AN4165 EMI measurements Figure 41. Peak measurement at 230 VAC/full load AM13388v1 Figure 42. Average measurement at 115 VAC/full load AM13389v1 Figure 43. Average measurement at 230 VAC/full load AM13390v1 Doc ID 023661 Rev 1 29/37 Board layout 14 AN4165 Board layout The board layout is shown in the figure below. Figure 44. Bottom layer & top overlay 30/37 Doc ID 023661 Rev 1 AN4165 15 Conclusions Conclusions The VIPER26 allows a simple design of a non-isolated converter with few external components. In this document a non-isolated flyback has been described and characterized. Special attention has been given to light load performance, confirmed as very good by bench analysis. Efficiency has been compared to the requirements of the Code of Conduct (version 4) for external AC/DC power supplies with very good results. Doc ID 023661 Rev 1 31/37 Test equipment and measurement of efficiency and light load performance Appendix A AN4165 Test equipment and measurement of efficiency and light load performance The converter input power has been measured using a wattmeter. The wattmeter measures simultaneously the converter input current (using its internal ammeter) and voltage (using its internal voltmeter). The wattmeter is a digital instrument so it samples the current and voltage and converts them to digital forms. The digital samples are then multiplied giving the instantaneous measured power. The sampling frequency is in the range of 20 kHz (or higher depending on the instrument used). The display provides the average measured power, averaging the instantaneous measured power in a short period of time (1 sec typ.). Figure 45 shows how the wattmeter is connected to the UUT (unit under test) and to the AC source and the wattmeter internal block diagram. Figure 45. Connections of the UUT to the wattmeter for power measurements Switch 1 WATT METER U.U.T (Unit Under test) Voltmeter V + Multiplier A X 2 Ammeter AC SOURCE INPUT OUTPUT AVG DISPLAY AM11590v1 An electronic load has been connected to the output of the power converter (UUT), allowing the converter load current to be set and measured, while the output voltage has been measured by a voltmeter. The output power is the product between load current and output voltage. The ratio between the output power, calculated as previously stated, and the input power, measured by the wattmeter, is the converter’s efficiency, which has been measured in different input/output conditions. A.1 Measuring input power With reference to Figure 45, the UUT input current causes a voltage drop across the ammeter’s internal shunt resistance (the ammeter is not ideal as it has an internal resistance higher than zero) and across the cables connecting the wattmeter to the UUT. If the switch of Figure 45 is in position 1 (see also the simplified scheme of Figure 46), this voltage drop causes an input measured voltage higher than the input voltage at the UUT input that, of course, affects the measured power. The voltage drop is generally negligible if the UUT input current is low (for example when we are measuring the input power of UUT in light load condition). 32/37 Doc ID 023661 Rev 1 AN4165 Test equipment and measurement of efficiency and light load performance Figure 46. Switch in position 1 - setting for standby measurements Wattmeter Ammeter AC SOURCE ~ V A + U.U.T. AC INPUT - UUT Voltmeter AM11591v1 In the case of high UUT input current (i.e. for measurements in heavy load conditions), the voltage drop can be relevant compared to the UUT real input voltage. If this is the case, the switch in Figure 45 can be changed to position 2 (see simplified scheme of Figure 47) where the UUT input voltage is measured directly at the UUT input terminal and the input current does not affect the measured input voltage. Figure 47. Switch in position 2 - setting for efficiency measurements Wattmeter A AC SOURCE Ammeter ~ V + - U.U.T. AC INPUT UUT Voltmeter AM11592v1 On the other hand, the position of Figure 47 may introduce a relevant error during light load measurements, when the UUT input current is low and the leakage current inside the voltmeter itself (which is not an ideal instrument and doesn't have infinite input resistance) is not negligible. This is the reason why it is better to use the setting of Figure 46 for light load measurements and Figure 47 for heavy load measurements. If it is not clear which measurement scheme has the lesser effect on the result, try with both and register the lower input power value. Doc ID 023661 Rev 1 33/37 Test equipment and measurement of efficiency and light load performance AN4165 As noted in IEC 62301, instantaneous measurements are appropriate when power readings are stable. The UUT is operated at 100% of nameplate output current output for at least 30 minutes (warm-up period) immediately prior to conducting efficiency measurements. After this warm-up period, the AC input power is monitored for a period of 5 minutes to assess the stability of the UUT. If the power level does not drift by more than 5% from the maximum value observed, the UUT can be considered stable and the measurements can be recorded at the end of the 5-minute period. If AC input power is not stable over a 5minute period, the average power or accumulated energy is measured over time for both AC input and DC output. Some wattmeter models allow integration of the measured input power in a time range and then measure the energy absorbed by the UUT during the integration time. The average input power is calculated dividing by the integration time itself. 34/37 Doc ID 023661 Rev 1 AN4165 16 References References – Code of Conduct on energy efficiency of external power supplies, version 4 – VIPER26 datasheet Doc ID 023661 Rev 1 35/37 Revision history 17 AN4165 Revision history Table 13. 36/37 Document revision history Date Revision 18-Feb-2013 1 Changes Initial release. Doc ID 023661 Rev 1 AN4165 Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. © 2013 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com Doc ID 023661 Rev 1 37/37