VIMARLOW NL4040-01BC-36 Thermoelectric cooler Datasheet

TECHNICAL DATA SHEET
NL4040
Thermoelectric Cooler
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
∆ Tmax (°C-dry N2):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
27°C
120
2.7
4.0
6.8
1.62
50°C
136
3.0
4.0
7.7
--
MECHANICAL CHARACTERISTICS
Positive Lead
.855
[21.72]
Leads: 22 AWG (0.64) Bus
Solid Tinned Copper
.253
[6.43]
Negative Lead
.425
[10.80]
Beryllium Oxide Handling
Precautions
Beryllium oxide can be toxic only when
dust, mist, or fumes containing particles
small enough to enter the lungs are
inhaled. For the user, precautions required
are to avoid grinding, machining or
pulverizing the material by mechanical,
thermal, or chemical processing.
marlow industries, inc.
4.00 +/-.25
[101.60+/-6.35]
1.113
[28.27]
.010 [0.25]
Cold Side
R
A
.001 [0.03]
.555+/-.013
[14.10 +/-0.33]
.003 [0.08]
Ceramic Material: Beryllia (BC)
Millimeters are in [ ]
ORDERING OPTIONS
Model Options
NL4040-01BC-36
NL4040-02BC-36
NL4040-03BC
NL4040-04BC
NL4040-05BC
A
PRODUCT FEATURES
Metallization
Both
Base
None
Both
Base
Elevated Temperature
Burn-In with test data
Yes
Yes
No
No
No



Pretinned metallized ceramic surface(s) with 117°C solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
DOC # 102-0308 REV K - PAGE 1 OF 2
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
Hot Side Temperature 50°C
160.0
120.0
0.00
120.0
0.50
80.0
1.00
T (C)
HEAT
LOAD
(WATTS)
T (C)
160.0
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
80.0
1.50
1.50
40.0
4.0
Q=0
T=0
2.0
1.0
2.0
3.0
4.0
CURRENT (AMPS)
3.00
0.0
VOLTAGE (VDC)
6.0
0.0
0.0
2.50
2.50
8.0
2.00
40.0
2.00
0.0
VOLTAGE (VDC)
TYPICAL PERFORMANCE CURVES
Hot Side Temperature 27°C
5.0
8.0
6.0
4.0
Q=0
T=0
2.0
0.0
0.0
1.0
2.0
3.0
4.0
CURRENT (AMPS)
5.0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at
877-627-5691.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information,
please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal
stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
CONTACT US:
For customer support or general questions please contact a local office below or visit our website at www.marlow.com.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
214-341-5212 (fax)
877-627-5691 (tech support)
www.marlow.com
Marlow Industries Europe GmbH
Brunnenweg 19-21
64331 Weiterstadt
Germany
Tel.: +49 (0) 6150 5439 - 403
Fax: +49 (0) 6150 5439 - 400
[email protected]
II-VI Japan Inc.
WBG Marive East 17F
2-6 Nakase, Mihama-ku
Chiba-Shi, Chiba 261-7117
Japan
81 43 297 2693 (tel)
81 43 297 3003 (fax)
[email protected]
www.ii-vi.co.jp
II-VI Singapore Pte., Ltd.
Blk. 5012, Techplace II
#04-07 & 05-07/12, Ang Mo Kio Ave. 5
Singapore 569876
(65) 6481 8215 (tel)
(65) 6481 8702 (fax)
[email protected]
www.ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
A subsidiary of II-VI Incorporated
Rm 202, 1# Lize 2nd Middle Road
Wangjing, Chaoyang District
Beijing 100102 China
010-64398226 ext 105 (tel)
010-64399315 (fax)
[email protected]
DOC # 102-0308 REV K - PAGE 2 OF 2
Similar pages