Switching spark gap SSG with lead wires Series/Type: Ordering code: FS04X-1JMG B88069X0410T502 Version/Date: Issue 06 / 2009-06-29 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or footer when copying the content. Identification/Classification 1: (header 1 + top left header bar) Switching spark gap Identification/Classification 2: (header 2 + bottom left header bar) SSG with lead wires Ordering code: (top right header bar) B88069X0410T502 Series/Type: (top right header bar) FS04X-1JMG EPCOS data AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information Preliminary (optional): contained therein without EPCOS' prior express consent is prohibited. (if necessary) Department: EPCOS AG is a TDK Group Company. KB PD AB E / KB PD AB PM Date: Issue 06 / 2009-06-29 Switching spark gap SSG with lead wires B88069X0410T502 FS04X-1JMG Features Applications Extremely long life time Stable performance over life Insensitive performance against variations in temperature Extremely low switching losses Very short breakdown time High reliability by robust design RoHS compatible Ignition of HID lamps Electrical specifications Nominal breakdown voltage VN Initial values Static breakdown voltage VS 1) 2) First ignition value VS, FTE after 24 hours in darkness Following ignition values (selection limits) Following ignition values VS, FIV Breakdown voltage VB (measuring time 200 ms) 4) First ignition value VB, FTE Following ignition values VB, FIV Electrical life time 3) Breakdown voltage VB First ignition value VB, FTE initial after 24 hours in darkness First ignition value VB, FTE after 24 hours in darkness Following ignition values VB, FIV Switching operations at - 40 °C at - 40 °C at +25 °C at +25 °C at +125 °C Ignition time tI 60 ms 5) Ignition time tI 200 ms Ignition time tI 60 ms Ignition time tI 200 ms Ignition time tI 60 ms Test circuit parameters Open circuit voltage V0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP KB PD AB E / KB PD AB PM Please read Cautions and warnings and Important notes at the end of this document. 400 V 460 360 ... 420 350 ... 430 V V V 460 340 ... 460 V V 460 500 340 ... 460 V V V 60 000 100 000 100 000 200 000 200 000 Ignitions Ignitions Ignitions Ignitions Ignitions 500 10 680 0.5 ~ 500 V k nF µH A Issue 06 / 2009-06-29 Page 2 of 5 Switching spark gap SSG with lead wires B88069X0410T502 FS04X-1JMG General technical data Insulation resistance at 100 V Early ignition values below 340 V Breakdown time Maximum switching frequency Maximum loading current Weight > 100 2 50 200 50 ~2 M % ns Hz mA g Marking, blue positive 400 WWY O 400 WW Y O 1) - Nominal voltage - Calendar week of production - Year of production - Non radioactive At delivery AQL 0,65 level II, DIN ISO 2859 Page 2, Fig. 1 and 2 Page 2, Fig. 3 and 4 Page 2, Fig. 3 and 4, 100 % outgoing inspection After storage in darkness for 30 days 2) 3) 4) 5) Figures Fig. 1: QC- test circuit (100% outgoing inspection) I= Fig. 2: Explanation of measurands 51k VS, FTE VS, FIV V DUT 0,22 F V VS ICU - VN DUT device under test ICU ignition control unit (sensitivity 10...30 A) Discharge current 10...20 mA Fig. 3: QC- test circuit (sampling inspection at 25 dVS/dt ~ dVN/dt Fig. 4: Explanation of measurands VB, FTE Range of VB, FIV L R VB Early i iti VN VO C DUT VB, FTE VB t tI 1s KB PD AB E / KB PD AB PM Please read Cautions and warnings and Important notes at the end of this document. 10 s Issue 06 / 2009-06-29 Page 3 of 5 Switching spark gap SSG with lead wires B88069X0410T502 FS04X-1JMG Dimensional drawing Not to scale Dimensions in mm Non controlled document Packing advice T502 = 500 pcs on tape and reel Cautions and warnings Switching spark gaps may be used only within their specified values. Damaged switching spark gaps must not be re-used. KB PD AB E / KB PD AB PM Please read Cautions and warnings and Important notes at the end of this document. Issue 06 / 2009-06-29 Page 4 of 5 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 5 of 5