EPCOS B5960 Ptc thermistors for overcurrent protection Datasheet

PTC thermistors for overcurrent
protection
SMDs, EIA size 1210,
24 V, 63 V and 230 V
Series/Type:
B5960*, B59707, B59807,
B59907
Date:
April 2007
 EPCOS AG 2007. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
Applications
Overcurrent protection
Short-circuit protection
A606/607, A707, A807, A907
Dimensional drawing
Features
Thermistor chip with lead-free tinned
terminations
Small size
Short response times
Suitable for reflow soldering only
Suitable for automatic placement
RoHS-compatible
Delivery mode
Blister tape, 180-mm reel
Dimensions in mm
Geometry of solder pad
Recommended maximum dimensions (mm)
General technical data
Switching cycles
Tolerance of RR
Tolerance of RR
Operating temperature range
Operating temperature range
Operating temperature range
Please read Cautions and warnings and
Important notes at the end of this document.
(for A606, A607, A707, A807)
(for A907)
(V = 0)
(V = Vmax, for A606/607, A707/807)
(V = Vmax, for A907)
Page 2 of 10
N
∆RR
∆RR
Top
Top
Top
100
±25
±35
40/+125
0/+60
40/+85
%
%
°C
°C
°C
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
A606/607, A707, A807, A907
Electrical specifications and ordering codes
Type
IR 1)
IS1)
mA
mA
ISmax
(V = Vmax)
A
Tref
RR
Rmin
°C
Ω
Ω
Vmax = 30 VDC or VAC , VR = 24 VDC or VAC
A606
90
180
0.5
110
A607
70
130
0.4
120
Vmax = 80 VDC or VAC , VR = 63 VDC or VAC
A707
50
90
0.3
120
Vmax = 265 VDC or VAC , VR = 230 VDC or VAC
A807
15
40
0.2
90
Vmax = 400 VDC or VAC , VR = 230 VDC or VAC
A907
12
22
0.15
125
1)
27
55
17
30
B59606A0110A062
B59607A0120A062
125
75
B59707A0120A062
400
200
B59807A0090A062
1500
640
B59907A0120A062
Measured on component soldered to standardized PCB
Please read Cautions and warnings and
Important notes at the end of this document.
Ordering code
Page 3 of 10
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
A606/607, A707, A807, A907
Reliability data
Test
Electrical endurance,
cycling
Electrical endurance,
constant
Damp heat
Standard
IEC 60738-1
Rapid change
of temperature
IEC 60738-1
Vibration
IEC 60738-1
Bump
IEC 60738-1
Climatic sequence
IEC 60738-1
Bending test
EN 130000/4.35
IEC 60738-1
IEC 60738-1
Please read Cautions and warnings and
Important notes at the end of this document.
Test conditions
Room temperature, ISmax; Vmax
Number of cycles: 100
Storage at Vmax /Top
Test duration : 1000 h
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
T = TLCT, T = TUCT
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 · 2 h
Test according to IEC 60028-2-6, Test Fc
Pulse shape: half-sine
Acceleration: 50 g
Pulse duration: 1 ms; 6 · 3 pulses
Test according to IEC 60068-2-29
Dry heat: T = TUCT
Test duration: 16 h
Damp heat first cycle
Cold: T = TLCT
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
Components reflow-soldered to test board
Maximum bending: 2 mm
Page 4 of 10
∆R25/R25
< 25%
< 25%
< 10%
< 10%
< 5%
< 5%
< 10%
< 10%
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
A606/607, A707, A807, A907
Characteristics (typical) for A606, A607 and A707
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
Switching time tS versus switching current IS
(measured at 25 °C in still air)
Rated current IR versus ambient temperature TA
(measured in still air)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 10
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
Characteristics (typical) for A807
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
A606/607, A707, A807, A907
Switching time tS versus switching current IS
(measured at 25 °C in still air)
Rated current IR versus ambient temperature TA
(measured in still air)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 10
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
Characteristics (typical) for A907
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
A606/607, A707, A807, A907
Switching time tS versus switching current IS
(measured at 25 °C in still air)
Rated current IR versus ambient temperature TA
(measured in still air)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 10
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
A606/607, A707, A807, A907
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The
thermistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative
humidity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term
operation (examples given under operation precautions).
Use thermistor within 6 months after delivery.
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting.
Especially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 10
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V
A606/607, A707, A807, A907
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas,
ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions.Contact with
any liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 10
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MLSC, MotorCap, PhaseCap,
PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, WindCap
are trademarks registered or pending in Europe and in other countries. Further information
will be found on the Internet at www.epcos.com/trademarks.
Page 10 of 10