MCC MP104 10 amp single phase bridge rectifier 50 to 1000 volt Datasheet

MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$ % !"#
Features
•
•
•
•
•
•
MP1005
THRU
MP1010
Low Forward Voltage Drop
Plastic Case
Any Mounting Position
Surge Rating Of 150 Amps
Case Material:Molded Plastic. UL Flammability
Classificatio Rating 94-0 and MSL Rating 1
Lead Free Finish/RoHS Compliant (NOTE 1)("P" Suffix
designates RoHS Compliant. See ordering information)
10 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
PB-6
Maximum Ratings
•
•
•
B
Operating Temperature: -55°C to +125°C
Storage Temperature: -55°C to +150°C
UL Recognized File # E165989
MCC
Catalog
Number
Device
Marking
MP1005
MP101
MP102
MP104
MP106
MP108
MP1010
MP1005
MP101
MP102
MP104
MP106
MP108
MP1010
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000v
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
C
E
D
G
+
AC
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Notes:
IF(AV)
10.0A
IFSM
150A
8.3ms, half sine
VF
1.1V
IFM = 5A per
element;
TJ = 25°C (Note 2)
IR
10µA
2mA
A
TJ = 75°C
TJ = 25°C
TJ = 100°C
1. High Temperature Solder Exemption Applied, see EU Directive Annex Notes 7
2. Pulse Test: Pulse Width 300usec, Duty Cycle 1%
AC
-
A
DIMENSIONS
DIM
A
B
C
D
E
G
INCHES
MIN
.578
.230
.752
.405
.038
.145
MAX
.619
.270
--.445
.042
---
MM
MIN
14.69
5.84
19.10
10.29
0.97
3.70
MAX
15.71
6.86
--11.31
1.07
---
NOTE
2PL
2PL
4PL/TYP
∅
www.mccsemi.com
Revision: 5
1 of 3
2008/01/30
MCC
MP1005 thru MP1010
TM
Figure 1
Typical Forward Characteristics
Micro Commercial Components
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
20
2
1
10
.6
6
.4
4
.2
2
TJ=25°C
25°C
µAmps .1
1
Amps
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.4
.6
.8
1.0
1.2
40
1.4
60
80
100
120
140
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
12
150
10
125
8
100
75
6
Amps
Amps
50
4
25
2
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
25
50
75
100
0
150
1
2
4
6
8 10
20
40
60 80 100
Cycles
175
°C
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
www.mccsemi.com
Revision: 5
2 of 3
2008/01/30
MCC
TM
Micro Commercial Components
Ordering Information
Device
Packing
(Part Number)-BP
Bulk;200pcs/Box
***IMPORTANT NOTICE***
Micro Commercial Components Corp . reserves the right to make changes without further notice to any
product herein to make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components Corp . does not assume any liability arising out of the application or
use of any product described herein; neither does it convey any license under its patent rights ,nor
the rights of others . The user of products in such applications shall assume all risks of such use
and will agree to hold Micro Commercial Components Corp . and all the companies whose
products are represented on our website, harmless against all damages.
***APPLICATIONS DISCLAIMER***
Products offer by Micro Commercial Components Corp . are not intended for use in Medical,
Aerospace or Military Applications.
www.mccsemi.com
Revision: 5
3 of 3
2008/01/30
Similar pages