ME60 60W Single Output External Power Medical Series Features Meets UL/EN/IEC60601-1-2, 4th edition for EMC* Approved to EN/IEC/UL60601-1, 3rd edition with isolation levels which satisfy the 2 MOPP requirements Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Desktop Style Package Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin E-cap life of >7 years 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for medical applications. The ME60A Medical Series low power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition and EN/IEC/UL60601-1-11:2010 for Home Healthcare (non-hospital use) applications with and isolation levels which satisfy the 2 MOPP requirements and * designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME60A Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20°C to +70°C, delivering full rated output power up to +40°C and applicable output power derating at 70°C. These models are available in desktop versions, include an IP22 rating per IEC60529 for the enclosure, and the output cable can be terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Model Number ME60A0551F01 Volts 5.0V Output Current 7.00A Output Power 35W Ripple & Noise¹ 75mV pk-pk Line Regulation ±1% Load Regulation ±5% ME60A1203F01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% ME60A1503F01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% ME60A1803F01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% ME60A2403F01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% ME60A4803F01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% ME60A0551N01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% ME60A1203N01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% ME60A1503N01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% ME60A1803N01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% ME60A2403N01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% ME60A4803N01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% ME60A0551Q01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% ME60A1203Q01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% ME60A1503Q01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% ME60A1803Q01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% ME60A2403Q01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% Output Connector Output Cable 6 pin Molex Type2 1150mm, #18AWG 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive 9V:1150mm 18AWG All others: 1500mm, #18AWG 6 pin Molex Type3 1150mm, #18AWG 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive 9V:1150mm 18AWG All others: 1500mm, #18AWG 6 pin Molex Type3 1150mm, #18AWG 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive 9V:1150mm 18AWG All others: 1500mm, #18AWG Input Configuration Class I Desktop, IEC60320 C14 Receptacle Class II Desktop, IEC60320 C8 Receptacle Class II Desktop, IEC60320 C18 Receptacle ME60A4803Q01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V models, values listed are typical, 100mV pk-pk maximum. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01). 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com ME60 Rev 2.7 2-AUG-16 1 ME60 60W Single Output External Power Medical Series General Specifications AC Input Input Current Inrush Current Input Fuses Earth Leakage Current Efficiency 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 1 sec @115Vac, full load 100Vac: 1.5A, 240Vac: 0.7A Hold-up Time 20mS min., at full Load, 100Vac input 264Vac, cold start: will not exceed 40A F1, F2: 2A, 250Vac fuses (line & neutral lines) provided on all models Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Overtemperature Protection Overload Protection Short Circuit Protection Overvoltage Protection >88%, typical Output Power 60W continuous – See models chart for specific voltage model ratings. No Load Input Power <0.210W (meets DoE Efficiency Level VI Requirements) Isolation Safety Standards Will shutdown upon an overtemperature condition, auto-recovery. 130 to 180% of rating, Hiccup Mode Hiccup Mode, auto recovery. 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Input-Output: 2 MOPP Input-Ground: 1 MOPP Output-Ground: 1 MOPP EN/IEC/UL60601-1, 3rd edition and EN/IEC/UL60601-1-11:2010 for Home Healthcare Ripple and Noise See models chart on pg 1. Operating Temperature -20°C to +70°C. Output Voltage See models chart on pg 1. Temperature Derating See derating curve. Transient Response Regulation Drop Test Vibration Dimensions Weight 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. Storage Temperature Altitude See models chart on pg 1. 1.4m from table top to wooden platform, 4 faces. Relative Humidity -40°C to +85°C Operating: to 5000m. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis W: 2.67” x L: 4.25” x H: 1.29” W: 67.9mm x L: 108mm x H: 32.7mm MTBF >250,000 hours, full load, 110 & 220Vac input, 25°C amb., per Telcordia 332 Issue 6. E-Cap Life 400g >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 5V, 12V model) All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com ME60 Rev 2.7 2-AUG-16 2 ME60 60W Single Output External Power Medical Series EMI/EMC Compliance Conducted Emissions: EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A IEC60601-1-2, 4th Edition, Table 4 Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz IEC60601-1-2, 4th Edition, Table 4 Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A IEC60601-1-2, 4th Edition, Table 5 Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields Rated Power frequency magnetic fields Voltage Interruptions, Dips, Sags & Surges EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A Surpasses IEC60601-1-2, 4th Edition requirements. EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz IEC60601-1-2, 4th Edition, Table 5 EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz IEC60601-1-2, 4th Edition, Table 4 EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20mS, 0 deg., Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Mechanical Drawing See Note 3: 9V through 48V Models: 2.5 x 5.5 x 9.5mm 5V Models: Output Connector: 6 pin Molex 39-01-2060 or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC² Barrel Connector, center positive² Notes: 1) All dimensions in mm. 2) Other options are available. 3) Cable length on 12V through 48V models is 1500mm, nominal. 4) The unit should not be covered or enclosed to protect against excessive case temperature rise. www.slpower.com ME60 Rev 2.7 2-AUG-16 3 ME60 60W Single Output External Power Medical Series Derating Chart: 70 Output Power- Watts 60 50 40 12V 30 18V 20 24V 48V 10 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature- ͦC Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive (6-pin Molex type - #51 – on 5V models). Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com ME60 Rev 2.7 2-AUG-16 4