B-XLS.5.6 Series Isolated 1W Single Output SIP7 DC/DC Converters SELECTION GUIDE Input Voltage (V) Output Voltage (V) Output Current (MA) Input Current (Rated Load) (MA) Efficiency (%) Isolation Capacitance (PF) MTTF1 (KHRS) B0505XLS.5.6 5 5 200 290 69 28 1847 B0512XLS.5.6 5 12 83 260 77 33 981 B0515XLS.5.6 5 15 67 253 79 40 667 B1205XLS.5.6 12 5 200 121 69 36 1485 B1212XLS.5.6 12 12 83 110 76 58 869 B1215XLS.5.6 12 15 67 110 76 56 613 B1505XLS.5.6 15 5 200 93 69 27 2110 B1512XLS.5.6 15 12 83 85 77 58 1790 B1515XLS.5.6 15 15 67 84 78 67 1560 B2405XLS.5.6 24 5 200 60 70 61 1253 B2412XLS.5.6 24 12 83 53 78 98 784 B2415XLS.5.6 24 15 67 52 80 122 566 Order code FEATURES ◆ RoHS compliant ◆ I/O isolation voltage 1000VDC ◆ Operating Temperature: -40℃~﹢85℃ ◆ High efficiency up to 81% ◆ Fully encapsulated toroidal magnetics ◆ Internal SMD construction ◆ Power density up to 0.85W/cm3 ◆ No electrolytic or tantalum capacitors ◆ 5V、12V&15V output ◆ No heat sink required ◆ Dual output from a single input rail ◆ UL 94V-0 package material ◆ No external components required ◆ Industry standard pin out ◆ Power sharing on output ◆ MTTF up to 3.4 million hours 1.Calculated using MIL-HDBK-217FN2 calculation model with nominal input voltage at full load. Input Characteristics Parameter MODEL SELECTION ① ② ③ ④ ⑤ Voltage range ⑥ B 05 05 X LS .5.6 ①Product Series ③Output Voltage ⑤Package Style ②Input Voltage ④Fixed Input ⑥Output 5&6 PIN Reflected ripple current Conditions Min Typ Max. Continuous operation,5V input types 4.5 5 5.5 Continuous operation,12V input types 10.8 12 13.2 Continuous operation,15V input types 13.5 15 16.5 Continuous operation,24V input types 21.6 24 26.4 5V&12V input types 1.6 2.0 15V&24V input types 5 10.0 Units V mA p-p APPLICATIONS The B-XLS.5.6 series of industrial temperature range DC/DC converters are the standard building blocks for on-board distributed power systems.They are ideally suited for providing single rail supplies on primarily digital boards with the added benefit of galvanic isolation to reduce switching noise. Surface mount technology and advanced packaging materials produce rugged reliable performance over an extended temperature range from -40°C to+85°C. MICRODC R ESERVES THE COPYRIGHT http://www.microdc.cn Absolute Maximum Ratings Lead temperature 1.5mm from case for 10 seconds Internal power dissipation 300°C 550mW Input voltage VIN,B0505XLS,B0512XLS,B0515XLS types 7V Input voltage VIN,B1205XLS,B1212XLS,B1215XLS types 15V Input voltage VIN,B1505XLS,B151XLS,B1515XLS types 18V Input voltage VIN,B2405XLS,B2412XLS,B2415XLS types 28V Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 1 of 4 B-XLS.5.6 Series OUTPUT CHARACTERISTICS Parameter Conditions Rated Power TA=-40°C to 120°C Voltage Set Point Accuracy See tolerance envelope Line regulation High VIN to low VIN Min. Typ. Max. Units 1 W 1.0 1.2 %% Typ. Max. Isolation Characteristics Parameter Conditions Min. Units Isolation test voltage Flash tested for 1 second 1000 VDC Resistance Viso= 1000VDC 10 GΩ Conditions Min. General Characteristics Parameter Typ. 5V input types 110 12V input types 160 15V input types 90 24V input types 80 Max. Switching frequency Units kHz Temperature Characteristics Parameter Conditions Min. Specification All output types -40 85 -50 130 Storage Typ. Max. Units ℃ 5V output types 23 All other output types 28 Case temperature above ambient TOLERANCE ENVELOPE B2405XLS.5.6 B1512XLS,B1515XLS,B2412XLS,B2415XLS All other types All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.Another 24V& 48V products, please inquire Our technical department! http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 2 of 4 B-XLS.5.6 Series Technical notes ISOLATION VOLTAGE "Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage. Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Professional Power Module B_XLS series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1KVDC for 1 second. A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals, such as the B_XLS series ,both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier, but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acssible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials. Construction and environment. The B_XLS series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. OUTPUT RIPPLE REDUCTION Output ripple reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: Ceramic chip capacitors are recommended. It is required that the ESR(Equivalent Series Resistance)should be as low as possible.X7R types are recommended. The voltage rating should be at least twice(except for 15V output),the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF(Self Resonant Frequency) should be >20MHz. CHARACTERISATION TEST METHODS Ripple & Noise Characterization Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 KHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 3 of 4 B-XLS.5.6 Series PACKAGE SPECIFICATIONS FOOTPRINT DETAILS MECHANICAL DIMENSIONS -7 PIN SIP 7 Pin SIP package Pin Function 1 2 +Vin -Vin NC -Vout +Vout 4 5 6 NC=No Connection TEMPERATURE DERATING GRAPHS All dimensions in inches ±0.01(mm±0.25mm). All pins on a 0.1(2.54) pitch and within ±0.01(0.25)of true position. RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS 7 Pin SIP Package 7 PIN SIP Tube All dimensions in inches ±0.01 (mm± 0.25mm). Unless otherwise stated all dimensions in inches (mm) ±0.5mm. Tube length (7 Pin SIP) : 20.47 (520mm ±2mm). Microdc Professional Power Module,Inc. Tube Quantity :25 RoHS COMPLIANT INFORMATION Tel:0086-20-86000646 E-mail:[email protected] This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C Website:http://www.microdc.cn for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Microdc Professional Power module,Inc.makes no representation that Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are the use of its products in the circuits described herein, or the use of other backward compatible with Sn/Pb soldering systems. technical information contained herein, will not infringe upon existing or future patent rights. Specifications are subject to change without notice. ©2010 Microdc Professional Power Module, Inc. Guangzhou REACH COMPLIANT INFORMATION This series has proven that this product does not contain harmful chemicals, it also has harmful chemical substances through the registration, inspection and approval. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 4 of 4