CUI CBM-979433B-136 Dc blower Datasheet

For more information, please visit the product page.
date
08/09/2017
page
1 of 7
SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
FEATURES
•
•
•
•
ball bearing design
multiple speed options for different cooling needs
12 Vdc input
auto restart protection standard on all models
MODEL
input
voltage
input
current1
input
power1
rated
speed1
air
flow2
static
pressure3
noise4
rated
(Vdc)
range
(Vdc)
max
(mA)
max
(W)
typ
(RPM±10%)
(CFM)
(inch H2O)
max
(dBA)
CBM-979433B-127
12
6~12
300
3.6
2700
22.4
0.43
50.0
CBM-979433B-132
12
6~12
440
5.28
3200
26.6
0.65
53.1
CBM-979433B-136
12
6~12
600
7.2
3600
30.5
0.92
55.8
CBM-979533B-154
12
6~13.2
1840
22.08
5400
44.2
3.39
62.8
CBM-979533B-168
12
6~12.6
4025
48.30
6800
54.7
5.22
69.9
Notes:
1.
2.
3.
4.
5.
At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 2 of 7
INPUT
parameter
conditions/description
operating input voltage1
min
typ
max
units
6
12
13.2
Vdc
starting voltage
Note:
6
Vdc
1. See Model section on page 1 for specific input voltage ranges.
PERFORMANCE2
parameter
conditions/description
min
rated speed
at rated voltage, 25°C, after 10 minutes
air flow
at 0 inch H2O, see performance curves
static pressure
noise
Note:
typ
max
units
2700
6800
RPM
22.4
54.7
CFM
at 0 CFM, see performance curves
0.43
5.22
inch H2O
at 1 m
50.0
69.9
dBA
2. See Model section on page 1 for specific values.
PROTECTIONS
parameter
conditions/description
auto restart
when the fan motor is locked by an external force,
the device will temporarily turn off electrical power
to the motor and restart automatically when the
locked rotor condition is released
min
typ
max
units
min
typ
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance of frame
at 500 Vdc between internal stator and positive
lead wire
dielectric strength
apply 500 Vac for 1 minute between housing and
positive lead wire
safety approvals
UL/cUL 507, TUV (EN 60950-1)
EMI/EMC
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
life expectancy
at 40°C, 65% RH
RoHS
2011/65/EU
10
MΩ
70,000
hours
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-10
70
°C
storage temperature
-40
70
°C
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 3 of 7
PERFORMANCE CURVES
24
0.80
Static Pressure
16
0.40
0
0
20
40
0
0.57
1.14
8
0
CFM
20
40
0. 57
CFM
1.14
CMM
Air Flow
CBM-979533B-154
mm H O
2
inch H O
2
101.6
48
1.60
76.2
Static Pressure
Static Pressure
0
0
CBM-979433B-136
32
0.80
16
4.0
ĵ
ĴįĶ
3.0
Ĵ
ijįĶ
50.8
2.0
ij
IJįĶ
25.4
0
0.40
CMM
Air Flow
mm H O
2
16
inch H O
2
Static Pressure
0.80
8
inch H O
2
mm H O
2
24
CBM-979433B-132
inch H O
2
mm H O
2
CBM-979433B-127
1.0
IJ
ıįĶ
0
20
0
0.57
Air Flow
40
CFM
1.14
CMM
cui.com
0
0
0
0.000
10
0.284
20
0.568
30
0.852
Air Flow
40
1.136
ı
50 CFM
1.420
CMM
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 4 of 7
PERFORMANCE CURVES (CONTINUED)
Static Pressure
6.0
ķ
5.0
Ķ
101.6
4.0
ĵ
76.2
3.0
Ĵ
50.8
2.0
ij
25.4
1.0
IJ
152.4
127
0
inch H O
2
mm H O
2
CBM-979533B-168
0
0
10
20
30
40
50
60 CFM
0.000 0.284 0.568 0.852 1.136 1.420 1.704
Air Flow
CMM
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 5 of 7
MECHANICAL
parameter
conditions/description
motor
4 pole DC brushless
min
bearing system
ball bearing
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CBM-979433B models: 97.2 x 94.4 x 33
CBM-979533B models: 97 x 95 x 33
material
PBT (UL94V-0)
weight
CBM-979433B models
CBM-979533B models
units: mm
wire: UL 1007, 24 AWG
CBM-979433B
WIRE CONNECTIONS
Function
Red
+Vin
Black
-Vin
CBM-979533B
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
cui.com
max
units
mm
mm
185
184
MECHANICAL DRAWINGS
Wire Color
typ
g
g
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 6 of 7
SAFETY CONSIDERATIONS
1.
Do not use or operate this fan in excess of the limitations set forth in this specification. CUI is not responsible for the
non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with
the specifications.
2.
CUI recommends adding a protection circuit to the product or application in which this fan is installed, such as a
thermo-fuse, or current fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric
shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure.
3.
CUI recommends installing a protection device to the product or application in which this fan is installed if there is a
possibility of reverse connection between Vdc (+) and GND (-). The failue to install such a device may result in smoke,
fire, and/or destruction, although these conditions may not manifest immediately.
4.
This fan mush be installed and used in compliance with all applicable safety standards and regulations.
5.
Use proper care when handling and/or installing this fan. Improper handling of installation of this fan may cause
damage that could result in unsafe conditions.
6.
Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components
of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
7.
Do not use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact CUI
to customize the product design for your application.
8.
For critical or extreme environments, including non-stop operation, please contact CUI and we will gladly provide
assistance with your product selection to ensure an appropriate cooling product for your application.
9.
When building your device, please examine thouroughly any variation of EMC, temperature rise, life data, quality, etc.
of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this
product, it should be mutually discussed and examined.
10. Use proper care when handling these fans. Components such as fan holders or bearings may be damaged, if touched
with fingers or other objects. Additionally, static electricity (ESD) may damage internal circuits of the fan.
11. Do not operate these fans in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or
corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2.
12. CUI recommends that you protect these fans from exposure to outside elements such as dust, condensation, humidity,
or insects. Exposure of this fan to such elements may affect its performance and my cause safety hazards. CUI does
not warrant against damage to the product caused by outside elements.
13. The fans must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and
noise.
14. Do not store these fans in an environment with high humidity. These fans must be stored in accordance with the
specified storage temperature.
15. CUI reserves the right to use components from multiple sources at its discretion. The use of components from other
sources will not affect the specifications as described herein.
16. The life expectancy of these fans has not been evaluated for use in combination with any end application. Therefore,
the life expectancy that relate to these fans are only for reference.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CBM-97B │ DESCRIPTION: DC BLOWER
date 08/09/2017 │ page 7 of 7
REVISION HISTORY
rev.
1.0
description
date
initial release
08/09/2017
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Similar pages