AIMTEC AM1A2415SZ 1 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM1A-Z
1 Watt | DC-DC Converter
FEATURES:





RoHS compliant
Regulated output voltage
Low ripple and noise
High efficiency up to 81%
No Minimum Load Required





Operating temperature -40oC to + 85oC
Input / Output Isolation 1500 VDC
Pin compatible with multiple manufacturers
6 pin SIP package
Wide 2:1 Input Range
Models
Single output
Model
AM1A-0505SZ
AM1A-0512SZ
AM1A-0515SZ
AM1A-0524SZ
AM1A-1205SZ
AM1A-1212SZ
AM1A-1215SZ
AM1A-1224SZ
AM1A-2405SZ
AM1A-2412SZ
AM1A-2415SZ
AM1A-2424SZ
AM1A-4805SZ
AM1A-4812SZ
AM1A-4815SZ
AM1A-4824SZ
FL= Full Load
Input
Voltage
(VDC)
Low line
Input
current
FL (mA)
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
9 - 18
9 - 18
9 - 18
9 - 18
18 - 36
18 - 36
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
36 - 75
289
278
275
275
141
138
136
138
71
68
69
68
36
35
34
34
Input
Voltage
(VDC)
Low line
Input
current
FL (mA)
4.5 - 9
4.5 - 9
9 - 18
9 - 18
18 - 36
18 - 36
36 - 75
36 - 75
285
282
138
138
69
70
34
35
Input Current
FL | No Load
(mA)
263
253
250
250
107
105
103
105
54
52
52
52
28
27
27
27
35
35
35
35
20
20
20
20
10
10
10
10
7
7
7
7
Output
Voltage
(VDC)
Output
Current
(mA)
Isolation
(VDC)
Max
Capacitive
Load (uF)
5
12
15
24
5
12
15
24
5
12
15
24
5
12
15
24
200
83
67
42
200
83
67
42
200
83
67
42
200
83
67
42
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1680
820
680
470
1680
820
680
470
1680
820
680
470
1680
820
680
470
76
79
80
80
78
80
81
80
78
80
80
81
76
78
78
77
Output
Voltage
(VDC)
Output
Current
(mA)
Isolation
(VDC)
Max
Capacitive
Load (uF)
Efficiency
(Full load)
(%)
±12
±15
±12
±15
±12
±15
±12
±15
±42
±33
±42
±33
±42
±33
±42
±33
1500
1500
1500
1500
1500
1500
1500
1500
±470
±330
±470
±330
±470
±330
±470
±330
77
79
79
80
80
79
77
77
Efficiency
(Full load)
(%)
Models
Dual output
Model
AM1A-0512DZ
AM1A-0515DZ
AM1A-1212DZ
AM1A-1215DZ
AM1A-2412DZ
AM1A-2415DZ
AM1A-4812DZ
AM1A-4815DZ
FL= Full Load
www.aimtec.com
F 051e R12.E
Input Current
FL | No Load
(mA)
259
254
106
105
52
53
27
27
35
35
20
20
10
10
7
7
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1A-Z
1 Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
15
24
Filter
Turn on Transient process time
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Input Reflected Ripple Current
Transient Recovery time
Transient Response Deviation
Maximum
4.5 – 9
9 - 18
18 - 36
36 - 75
Capacitor
1
50
0-15
0-25
0-50
0-100
100
35
500
±3
5 Vin
12 Vin
15 Vin
24 Vin
See application circuit
25% load step change
25% load step change
Units
VDC
ms
ms
VDC
ms
mA pk-pk
µs
%
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
60 sec
Rated
Units
1500
VDC
MOhm
pF
Maximum
Units
> 1000
70
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation (Single)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Cross Regulation (Dual)
Temperature coefficient
Ripple & Noise*
Conditions
Typical
0% to 100% load
0% to 100% load
5% to 100% load
25% to 100% coupled
to full load
±2
Continuous with auto recovery
±0.2
±1.0
±2.0
±1.0
%
%
%
%
%
%
±5
%/oC
mV p-p
±0.02
50
At 20MHz Bandwidth
*Measured with a 1µF ceramic capacitor.
General Specifications
Parameters
Switching frequency
Max Case temperature
Operating temperature
Storage temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
150 - 550
Maximum
+105
Full Load without Derating
-40 to +85
-55 to +125
Not Required
Free air convection
Units
KHz
oC
oC
oC
95
%
Non conductive black plastic
3.0
g
0.67 x 0.43 x 0.30 inch
17.0 x 10.9 x 7.6 mm
>2,800,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1A-Z
1 Watt | DC-DC Converter
Safety Specifications
Parameters
Agency Approval & Safety
CE, UL
UL60950-1
EN 55022: 2010+AC: 2011, Class A (external reference circuit below)
EN 55024: 2010
IEC 61000-4-2: 2008
IEC 61000-4-3: 2010
IEC 61000-4-4: 2012*
IEC 61000-4-5: 2005*
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
*External filter capacitor for 5Vin 330µF/100V EEC & all other models 220µF/100V EEC
Recommended Surge Protective Circuit
Vin+
+
Vo+
Aimtec
DC-DC
Converter
C1
Vin-
-
Vo-
C1: 5V input models = 330 µF / 100V, all other models = 220 µF / 100V
Recommended Circuits for Conducted Emissions
Single Output
Dual Output
Model
C1
L1
C2
5 Vin
12 Vin
24 Vin
48 Vin
MLCC 4.7 µF / 50V
MLCC 4.7 µF / 50V
MLCC 4.7 µF / 50V
MLCC 4.7 µF / 100V
4.7 µH
4.7 µH
18 µH
18 µH
MLCC 220pF / 3kV
MLCC 220pF / 3kV
MLCC 220pF / 3kV
MLCC 220pF / 3kV
Input Reflected Ripple Test Circuit
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1A-Z
1 Watt | DC-DC Converter
Pin Out Specifications
Pin
Single
Dual
1
2
4
5
6
- V Input
+ V Input
+ V Output
No pin
- V Output
- V Input
+ V Input
+ V Output
Common
- V Output
Dimensions
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages