Nova NGHS11-1.5K60-115D-120 True on-line up Datasheet

ADVANCED FEATURES
S
Automatic DC offset
Totally Modular Design
Two Stage Battery Charger
Input Inrush Current Control
Synchronized PFC Modules
odu es
Efficiency exceeding 80%
RUGGED
NAVY GALAXY SERIES
TM
TM
TRUE ON-LINE UPS
POWER FACTOR CORRECTED
&
GALVANICALLY ISOLA
ISOLATED
1 5KVA & 2.5K
2 5K
1.5KVA
2.5KVA
BULKHEAD MOUNT
APPLICATIONS
ATIONS
AP
A
PPL
PP
P
PLL IICATIONS
P
CA
C
AT
A
TTIIO N S
This rugged UPS is specifically designed
for submarine and shipboard applications
in compliance to MIL-STD-1399, MIL-STD-461,
MIL-S-901, MIL-STD-167, MIL-STD-810,
and MIL-STD-740. It provides very high quality
pure sinewave output (2% THD) and is capable
of driving non-linear loads such as non-PFC
Switching Power Supplies.
OPTIONAL FEATURES SHOWN
NOVA
ELECTRIC
N
OVA E
LECTRIC
www.novaelectric.com
[email protected]
A Leader in UPS Technology since 1966 - 500VA to 500+KVA
ADVANCED TRUE ONLINE RUGGED SINEWAVE UPS
BULKHEAD MOUNT
Designed to comply with MIL-STD-1399, MIL-STD-461, MIL-STD-167, MIL-STD-810, MIL-S-901 and MIL-STD-740.
SPECIFICATIONS
APPLICATIONS
ENVIRONMENTAL
ELECTRICAL
This Power Factor Corrected Shipboard /
Submarine Grade UPS is specifically
designed and tested for Naval
Applications where MIL-STD-1399
power requirements apply. This unit
contains many advanced features,
yielding superior performance and
reliability.
OPTIONS
Single Phase Input
RS 232 or SNMP Interface
MS Connector Mates
High Speed Mechanical Transfer Switch
Wide temperature range
Shock mounts
Manual bypass switch
External bypass switch
Custom Paint & Markings
DIMENSIONS
30” H x 24” W x 12” D
including internal batteries
Optional Input Voltages available (select):
115, 120, 208, 220, 230, 240 VAC. 1Ø
115/200, 120/208, 220/380 3Ø
Optional Input Frequencies available (specify):
50, 60 or 400 Hz
Optional Output Voltages Available (specify):
115, 120, 208, 220, 230, 240 VAC 1Ø
Output Frequency (specify): 50, 60 or 400Hz
Voltage Regulation: ± 2% NL to FL
Frequency Regulation: 0.1%
Harmonic Distortion: 2% THD Typical
5% Max
Input Power Factor: 0.99
Efficiency at full load: 82% typical
Overload: 125% for 5 minutes
INTERNAL BATTERIES
Premium wide temp batteries which
are sealed, maintenance- free, and
user replaceable. Extended runtime
available
Operating Temp: -20° to +50°C per MILSTD-810
Storage Temp Range: -40° to +60°C
Humidity: to 95% non-condensing
Elevation: 15,000 Ft. (4,572m) operating
40,000Ft(12,192m) non-operating
Audible Noise: Less than 55 dbA at 5 ft.
Cooling: Forced air
EMI: per MIL-STD-461
Vibration: per MIL-STD-167
Shock: 20g for 20mS half sinewave per
MIL-S-901D Grade A
Structureborne noise: MIL-STD-740B Grade A
MTBF: 100,000+ hours per field data
MTTR: 30 minutes
ALARMS & DIAGNOSTICS
System Status (Green/Red)
Utility Off (Red)
UPS Overload (Red)
UPS Off (Red)
Over Temp. (Red)
Low Battery (Red)
Load On Utility (Red)
Logic Fault (Red)
(with XFR SW Option)
Alarm Contacts: Standard
RS 232 or SNMP: Optional
PROTECTIVE FEATURES
AC & DC Input Circuit Breakers, Low
Battery Shut Off, Overload & Thermal
Protection, Audible Alarm with
Silence Switch, and optional EPO.
MODEL SELECTION
PARTIAL MODEL SELECTION
NGHS11-1.5K60-115-120
NGHS11-1.5K60-115(D)-120
NGHRS11-2.5K60-115-120
NGHS11-2.5K60-115(D)-120
KVA
1.5
1.5
2.5
2.5
INPUT
OUTPUT
UPS LBS
RUN TIME
115 VAC
115 VAC L-L
115 VAC
115 VAC L-L
120 VAC
120 VAC
120 VAC
120 VAC
145
145
155
155
10 min
10 min
10 min
10 min
TYPICAL OUTLINE DRAWING
WEB : www.novaelectric.com
E-Mail : [email protected]
PHONE : (201) 385-0500 FAX : (201) 385-0702
NOVA ELECTRIC
A Division of
TECHNOLOGY DYNAMICS, INC.
100 School St., Bergenfield NJ 07621
ISO 9001
Similar pages