ADVANCED FEATURES S Automatic DC offset Totally Modular Design Two Stage Battery Charger Input Inrush Current Control Synchronized PFC Modules odu es Efficiency exceeding 80% RUGGED NAVY GALAXY SERIES TM TM TRUE ON-LINE UPS POWER FACTOR CORRECTED & GALVANICALLY ISOLA ISOLATED 1 5KVA & 2.5K 2 5K 1.5KVA 2.5KVA BULKHEAD MOUNT APPLICATIONS ATIONS AP A PPL PP P PLL IICATIONS P CA C AT A TTIIO N S This rugged UPS is specifically designed for submarine and shipboard applications in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, and MIL-STD-740. It provides very high quality pure sinewave output (2% THD) and is capable of driving non-linear loads such as non-PFC Switching Power Supplies. OPTIONAL FEATURES SHOWN NOVA ELECTRIC N OVA E LECTRIC www.novaelectric.com [email protected] A Leader in UPS Technology since 1966 - 500VA to 500+KVA ADVANCED TRUE ONLINE RUGGED SINEWAVE UPS BULKHEAD MOUNT Designed to comply with MIL-STD-1399, MIL-STD-461, MIL-STD-167, MIL-STD-810, MIL-S-901 and MIL-STD-740. SPECIFICATIONS APPLICATIONS ENVIRONMENTAL ELECTRICAL This Power Factor Corrected Shipboard / Submarine Grade UPS is specifically designed and tested for Naval Applications where MIL-STD-1399 power requirements apply. This unit contains many advanced features, yielding superior performance and reliability. OPTIONS Single Phase Input RS 232 or SNMP Interface MS Connector Mates High Speed Mechanical Transfer Switch Wide temperature range Shock mounts Manual bypass switch External bypass switch Custom Paint & Markings DIMENSIONS 30” H x 24” W x 12” D including internal batteries Optional Input Voltages available (select): 115, 120, 208, 220, 230, 240 VAC. 1Ø 115/200, 120/208, 220/380 3Ø Optional Input Frequencies available (specify): 50, 60 or 400 Hz Optional Output Voltages Available (specify): 115, 120, 208, 220, 230, 240 VAC 1Ø Output Frequency (specify): 50, 60 or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: 0.1% Harmonic Distortion: 2% THD Typical 5% Max Input Power Factor: 0.99 Efficiency at full load: 82% typical Overload: 125% for 5 minutes INTERNAL BATTERIES Premium wide temp batteries which are sealed, maintenance- free, and user replaceable. Extended runtime available Operating Temp: -20° to +50°C per MILSTD-810 Storage Temp Range: -40° to +60°C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating 40,000Ft(12,192m) non-operating Audible Noise: Less than 55 dbA at 5 ft. Cooling: Forced air EMI: per MIL-STD-461 Vibration: per MIL-STD-167 Shock: 20g for 20mS half sinewave per MIL-S-901D Grade A Structureborne noise: MIL-STD-740B Grade A MTBF: 100,000+ hours per field data MTTR: 30 minutes ALARMS & DIAGNOSTICS System Status (Green/Red) Utility Off (Red) UPS Overload (Red) UPS Off (Red) Over Temp. (Red) Low Battery (Red) Load On Utility (Red) Logic Fault (Red) (with XFR SW Option) Alarm Contacts: Standard RS 232 or SNMP: Optional PROTECTIVE FEATURES AC & DC Input Circuit Breakers, Low Battery Shut Off, Overload & Thermal Protection, Audible Alarm with Silence Switch, and optional EPO. MODEL SELECTION PARTIAL MODEL SELECTION NGHS11-1.5K60-115-120 NGHS11-1.5K60-115(D)-120 NGHRS11-2.5K60-115-120 NGHS11-2.5K60-115(D)-120 KVA 1.5 1.5 2.5 2.5 INPUT OUTPUT UPS LBS RUN TIME 115 VAC 115 VAC L-L 115 VAC 115 VAC L-L 120 VAC 120 VAC 120 VAC 120 VAC 145 145 155 155 10 min 10 min 10 min 10 min TYPICAL OUTLINE DRAWING WEB : www.novaelectric.com E-Mail : [email protected] PHONE : (201) 385-0500 FAX : (201) 385-0702 NOVA ELECTRIC A Division of TECHNOLOGY DYNAMICS, INC. 100 School St., Bergenfield NJ 07621 ISO 9001