ETC2 EFRP-G2653 Erp2u 650w server power supply Datasheet

EFRP-G2653
ERP2U 650W Server Power Supply
Features:
2U Form Factor
650W with ATX Outputs
80PLUS® Gold Level Power Efficiency
PMBus 1.2 Support
N+1 Redundancy / Load Sharing
0~50℃Working Temperature
General Specification
Input Range: 100 to 240 VAC, +/-10%
10%
Power Factor: > 0.99 minimum
Efficiency: ≥92% (Power Module)
Hold Up Time: 17ms @ 70% Load
Short Circuit Protection
Over Current Protection
Over Voltage Protection
No Load Operation
MTBF >100,000 Hours@25℃
Operating Temperature: 0 to 50 ℃
Operating Humidity: 20 to 90 %
EMI/RFI: CE, FCC class B
Safety: UL, TUV, CCC, CB, BSMI
Input
nput and Output Characteristics
Input
Output
Voltage
Frequency
Current
100~240
47~63Hz
8.5
8.5~3.5A
VAC
1.
Load
+3.3V
+5V
+12V
-12V
+5VSB
Max.Load
25A
25A
53A
0.5A
3A
Min.Load
0A
0A
0.1A
0A
0A
The +5 & +3.3 Volt total output shall not exceed 150W.
1
Ripple and Noise
Output
+3.3V
+5V
+12V
-12V
5Vsb
Load Regulation
±5%
5%
± 5%
± 5%
± 5%
± 5%
Line Regulation
± 1%
± 1%
± 1%
± 1%
± 1%
Ripple & Noise
60mV
mV
60mV
120mV
120mV
60mV
0mV
Mechanical
Outline Drawing
Outline Dimension: 101.8x83.4x280(mm)
©ETASIS Electronic Corporation. All rights reserved. ETASIS Electronics Corporation reserves the right to make changes to their
products, specification, or to discontinue any product and its service at anytime without notice. The information and specification from
ETASIS is believed to be accurate and reliable. However, ETASIS assumes no responsibility for any business loss due to specification
changes. ETASIS products are not designed to be used in system deemed to be critical, or in any system wherein failure or malfunction
could result in injury or death.