ACT ACTF8092-F864W-DCC6C Low-loss rf filter Datasheet

Features ACTF8092-F864W-DCC6C
 Low-loss RF filter
 High Rejection
 Single Ended Operation at 50Ω without Matching
 Ceramic Package for Surface Mounted
Technology (SMT)
 Lead-free Production and RoHS Compliance
Package Dimensions
Ceramic Package: DCC6C
Pin Configuration
2
Input
5
Output
1, 3, 4, 6
Case Ground
1, 3, 4, 6
To Be Grounded
Marking
Top View, Laser Marking
ACTF*
8092F
"ACTF”:
Manufacturer’s mark
“F”:
SAW filter
“8092”:
Part number
” · ”:
Terminal 1
“*”:
Code
Lot number (The code shown below varies in a 4-year cycle)
1
2
3
4
2009
A
B
C
D
2010
N
P
Q
R
2011
a
b
c
d
2012
n
p
q
r
5
6
7
8
9
E
F
G
H
J
S
T
U
V
W
e
f
g
h
i
s
t
u
v
w
10
11
12
K
L
M
X
Y
Z
j
k
m
x
y
z
Maximum Ratings
Rating
Value
Unit
TA
-40 ~ +85
°C
Storage Temperature Range
Tstg
-40 ~ +85
°C
DC Voltage (between any Terminals)
VDC
5
V
RF Power (in BW)
P
18
dBm
ESD Voltage (HB)
VESD
150
V
Operating Temperature Range
Electrical Characteristics (-40°C ~ +85°C)
Item
Minimum
Typical
Maximum
Unit
Center Frequency
fC
-
866.50
-
MHz
Maximum Insertion Loss in 865.0 ~ 868.0 MHz
IL
-
2.8
3.5
dB
Maximum Insertion Loss in 863.0 ~ 870.0 MHz
IL
-
2.8
3.8
dB
Absolute Attenuation
α
0.3000 … 830.00 MHz
40
44
-
dB
830.00 … 845.00 MHz
38
44
-
dB
880.00 … 884.30 MHz
50
60
-
dB
884.00 … 887.00 MHz
50
60
--
dB
887.00 … 965.00 MHz
38
42
dB
965.00 … 1500.00 MHz
42
47
dB
Passband Ripple
Δα
865.0 ~ 868.0 MHz
0.6
1.0
dB
Passband Ripple
Δα
863.0 ~ 870.0 MHz
0.7
2.0
dB
Source / Load Impedance (single ended)
RoHS Compliant
Typical Frequency Response
50
Electrostatic Sensitive Device
Ω
Stability Characteristics
Test item
Condition of test
1
Mechanical shock
(a) Drops: 3 times on concrete floor
(b) Height: 1.0 m
2
Vibration resistance
(a) Frequency of vibration: 10~55Hz
(c) Directions: X,Y and Z
(b) Amplitude: 1.5 mm
(d) Duration: 2 hours
3
Moisture resistance
(a) Condition: 40°C, 90~95% R.H.
(c) Wait 4 hours before measurement
(b) Duration: 96 hours
4
Climatic sequence
(a) +70°C for 16 hours
(b) +55°C for 24 hours, 90~95% R.H.
(c) -25°C for 2 hours
(d) +40°C for 24 hours, 90~95% R.H.
(e) Wait 4 hours before measurement
5
High temperature exposure
(a) Temperature: 70°C
(c) Wait 4 hours before measurement
6
Thermal impact
(a) +70°C for 30 minutes ⇒ -25°C for 30 minutes repeated 3 times
(b) Wait 4 hours before measurement
(b) Duration: 250 hours
Requirements: The SAW filer shall remain within the electrical specifications after tests.
Remarks
 SAW devices should not be used in any type of fluid such as water, oil, organic solvent, etc.
 Be certain not to apply voltage exceeding the rated voltage of components.
 Do not operate outside the recommended operating temperature range of components.
 Sudden change of temperature shall be avoided, deterioration of the characteristics can occur.
 Be careful of soldering temperature and duration of components when soldering.
 Do not place soldering iron on the body of components.
 Be careful not to subject the terminals or leads of components to excessive force.
 SAW devices are electrostatic sensitive. Please avoid static voltage during operation and storage.
 Ultrasonic cleaning shall be avoided. Ultrasonic vibration may cause destruction of components.
Test Circuit
Recommended Land Pattern
50Ω / 50Ω Configuration
Packing Information
Carrier Tape
Reel Dimensions
Outer Packing
Type
Carton Box
Ⅰ
Carton Box Ⅱ
Quantity
Dimension
Description
Weight
5000
190×190×95
0.85
10000
190×190×190
anti-static plastic bag & carton box
1 reel / bag
5 bags / box (5000 pcs)
10 bags / box (10000 pcs)
Unit: mm
1.70
Unit: kg
Recommended Soldering Profile
1.
2.
3.
The specifications of this device are subject to change or obsolescence without notice.
Typically, equipment utilizing this device requires emissions testing and government approval, which is the responsibility
of the equipment manufacturer.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes
and circuits implemented within components or assemblies.
Similar pages