ETC1 APS100HD-24B-D033B 18-36 vdc input range dc-dc converter half-brick power modules 100-150 watts single & dual output Datasheet

Advanced Power Solutions
18-36 VDC INPUT RANGE DC-DC CONVERTER HALF-BRICK POWER
MODULES 100-150 WATTS SINGLE & DUAL OUTPUT
APS100HD-24B-S&D SERIES
FEATURES:
n
SINGLE & DAUL OUTPUT
n
WIDE 2:1 INPUT RANGE
n
1500VDC ISOLATION
n
STANDARD HALF-BRICK PACKAGE
n
HIGH-EFFICIENCY POWER MODULE
n
UNDER-VOLTAGE LOCKOUT
n
DESIGNED TO MEET INTERNATIONAL
SAFETY STANDARDS
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Range: Wide 2:1 Input DC Range 18-36Vdc.
Input Voltage: Nominal 24Vdc.
Input Current: Typ. 6.85A full load and 0.06A no-load
@ 24Vdc nominal input.
Input Fuse: Use external fuse.
Inrush Current: Peak 20A @ 24Vdc.
Input Filter: Pi-Network for EMI suppression.
Under-Voltage Protection (UVP): Lock-out activated at
17.8 Vdc input.
Input Reflected Ripple Current: 28.4mA pk-pk @24 Vdc.
Isolation Voltage: 1,500Vdc input-output.
Remote On/Off: TTL/CMOS-Compatible input control.
Logic input reference to -Vin.
Logic [1]/Open(or 2.4Vdc above -Vin)=ON.
Logic [0]/Short(or 0~0.08Vdc above -Vin)=OFF.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 100-150W continuous.
Line Regulation: Typ. 0.1%.
Load Regulation: Typ. ±1.0%.
Noise & Ripple: Typ. 120mV, peak to peak.
OVP: Built-in.
Adjustability: Factory set.
Overload Protection (OLP): Fully protected against
overload and short circuit. Typical 130% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 83.8-87%, various with input.
Switching Frequency: Fixed frequency 330K Hz.
Circuit Topology: Forward Circuit.
Transient Response: Peak transient <220mV and recovers
within 1mS after 25% load-change.
Power Density: 36.0 Watts / Cubic inch.
Operating Temperature: -40 to +100°C (baseplate).
Storage Temperature: -40 to +100 °C.
Temperature Coefficient: 0.02%/°C.
Humidity: Up to 95% RH, Non-Condensing.
Case: Aluminum baseplate.
Industrial Grade.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise spec.
(2) Line Regulation measured from High to Low Lines at full load.
(3) Load Regulation measured from Full-Load (F-L) to Half-Load(H-L)at nominal input.
(4) Correct fuse size by calculating the max. DC current drain at low Line input & adding 20-25% for desired fuse size.
INPUT/OUTPUT & VOLTAGE/CURRENT RATINGS
SINGLE OUTPUT
MODEL NO.
APS100HD-24B-S018
APS100HD-24B-S025
APS100HD-24B-S033
APS100HD-24B-S050
APS100HD-24B-S120
APS100HD-24B-S150
INPUT Vdc
Range
Nominal
18-36Vdc
18-36Vdc
18-36Vdc
18-36Vdc
18-36Vdc
18-36Vdc
OUTPUT VO1 ? @ #
Min.
Volt.
Max.
24Vdc
24Vdc
24Vdc
24Vdc
24Vdc
24Vdc
0A
0A
0A
0A
0A
0A
1.8Vdc
2.5Vdc
3.3Vdc
5.0Vdc
12.0Vdc
15.0Vdc
30A
30A
30A
25A
12A
10A
DUAL OUTPUT
MODEL NO.
APS100HD-24B-D025B
APS100HD-24B-D033B
APS100HD-24B-D033C
APS100HD-24B-D050C
APS100HD-24B-D050D
INPUT Vdc
Range
Nominal
18-36Vdc
18-36Vdc
18-36Vdc
18-36Vdc
18-36Vdc
24Vdc
24Vdc
24Vdc
24Vdc
24Vdc
OUTPUT VO1 ? @
Min. Typ. Volt. Max.
2.0A
2.0A
2.0A
2.0A
2.0A
18A
17A
17A
14A
14A
MECHANICAL DIMENSIONS: MM [INCHES]
2.5Vdc
3.3Vdc
3.3Vdc
5.0Vdc
5.0Vdc
25A
24A
24A
20A
20A
AUX. OUTPUT VO2 ? @
Min. Typ. Volt. Max.
0A
0A
0A
0A
0A
18A
18A
15A
15A
12A
1.8Vdc
1.8Vdc
2.5Vdc
2.5Vdc
3.3Vdc
25A
25A
20A
20A
18A
WEIGHT: 73.0g (2.6 Oz.)
PIN ASSIGNMENT
PIN NO.
SINGLE
DUAL
PIN# 1.
+Vin
+Vin
PIN# 3.
Remote
ON/OFF
CASE
Remote
ON/OFF
CASE
PIN# 4.
-Vin
-Vin
PIN# 5.
DC COM.
VO2
PIN# 6.
-SENSE
DC COM
PIN# 7.
VO1 ADJ.
VO2 ADJ.
PIN# 8.
+SENSE
VO1
PIN# 9.
VO1
DC COM
PIN# 10.
-------
VO1 ADJ.
PIN# 2.
SINGLE O/P
DUAL O/P
Similar pages