TE CFS Power entry module with switch Datasheet

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Entry Module with Switch
C Series
UL Recognized
CSA Certified
VDE Approved*
15CS1
3CFS1
C Series
Specifications
• Two function power entry module combining
a DPST switch and an IEC 60320-1 inlet
Maximum leakage current each Line to Ground:
F Models
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
• Snap–in or flange mounting
• Available with or without a shielded general
purpose or medical grade filter
Hipot rating (one minute):
Line to Ground:
Line to Line:
• Two element circuit provides enhanced EMI
attenuation
Rated Voltage:
• Reduce OEM wiring time with optional
pre–connected line and switch terminals
Rated Current:
Output Styles
1 – Spade terminals
250 VAC
50/60 Hz
1 to 15A*
DPST
10,000 operations at 51A max. inrush
Ordering Information
10 C F S 1
2 A
5 A
2250 VDC
1450 VDC
Operating Frequency:
Switch:
H & Unfiltered
.25 mA
.40 mA
.250 Terminal Push–on Force:
18 lb. / 80N (max.)
.188 Terminal Push–on Force:
15 lb. / 67N (max.)
(size varies)
Mounting Styles
E – Flange Mount
S – Snap–in
Filter Type or Terminal Option
F – General purpose
H – Medical
B – No filter, includes
Pre–connected terminals
Omit if none
C Series
Current Rating
1, 3, 6, 10 or 15A
(Filtered versions up to 10A)
Available Part Numbers
Filtered Versions
1CHE1
1CFE1
3CHE1
3CFE1
6CHE1
6CFE1
10CHE1
10CFE1
1CHS1
1CFS1
3CHS1
3CFS1
6CHS1
6CFS1
10CHS1
10CFS1
Non–filtered Versions
Standard Terminals
Pre-connected Terminals
10CS1
10CE1
15CS1
15CE1
10CBS1
10CBE1
15CBS1
15CBE1
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
130
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Entry Module with Switch
(continued)
C Series
Electrical Schematics
CE, CBE
A
F Models
.210
5.34
B
LINE
LOAD
F
Max.
C
H Models
LINE


LOAD








3
CFS, CHS
Power Inlet Filters & Power Entry Modules
B Models
C
Power On/Off
L
L
Note 1
Note 2
Note 1
Note 2
G
G
N
N
Note 1: Jumpers provided on CBS and CBE versions only.

 Note

2: Location of optional filter
A
.210
5.34
Max.



B


Case Styles
CFE, CHE
CS, CBS
B
.210 Max.
5.34
A
C
C
F
.210
5.34
Max.
B
A















131
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Entry Module with Switch
(continued)
C Series
Case Styles (continued)
Case Dimensions
CBS, CBE Pre-Connected Terminals
Part No.
CS, CBS
CE, CBE
CFS, CHS
CBS, CBE Side View
CBS Rear View
CBE Rear View
CFE, CHE
A
B
C



























D


E


F


 

 
  
  
 

 
  
  

Recommended Panel Cutout
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
D
.06
R max
1.52
E
F






132
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Entry Module with Switch
(continued)
C Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1CF
3CF
6CF
10CF
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz
0
10
0.1
1
10
30
Frequency in MHz
0
0.1
1
1CH
3CH
6CH
10CH
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
0
3
Power Inlet Filters & Power Entry Modules
50
40
10
30
Frequency in MHz
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
 


  





Differential Mode / Symmetrical (Line to Line)

 


  






 
 
































































 
 
































































133
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com