Bel Power Solutions MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high peak current capabilities in a compact 4.5 x 8.5 x 2.0 inch U-channel chassis. Other standard features include auto select AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50°C. All products are approved to the latest international regulatory standards and display the CE Mark. RoHS Compliant Automatic 115/230 Input Voltage Selection All Outputs Fully Regulated Remote Sense, Overvoltage Protection and Overtemperature Protection Power Fail Signal Included Greater than 100,000 Hour MTBF U-Channel Chassis: 8.5 x 4.5 x 2.0 inch (215.9 x 114.3 x 50.8 mm) Optional Cover Metric and SAE Mounting Inserts MAP130 Series 2 MODEL6 OUTPUT VOLTAGE ADJUSTMENT RANGE CONTINUOUS CURRENT PEAK CURRENT1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE2 INITIAL SETTING ACCURACY MAP130-1005G 5V 4.75V to 5.50V 26A 30A 3 0.2% 1% 1% 5.1V to 5.2V 3 0.2% 1% 1% 12.0V to 12.2V 0.2% 1% 1% 23.9V to 24.1V MAP130-1012G 12/15V 11.4V to 15.75V 12A/10A 13.8A/11A MAP130-1024G 24V/28V 22.5V to 30.0V 6.25A/5.4A3 6.8A/5.9A3 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT4 LINE REGULATION LOAD REGULATION RIPPLE & NOISE5 INITIAL SETTING ACCURACY +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.75V to 12.0V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.9V to 12.1V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V +5V 4.75V to 5.50V 20A 30A 1% 1% 1% 5.1V to 5.2V +15V 14.0V to 16.0V 4A 8A 1% 2% 1% 15.0V to 15.1V -5V Fixed 1A 1A 2% 2% 1% -4.8V to -5.2V -15V Fixed 1A 1A 2% 2% 1% -14.7V to -15.3V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V +12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 3A 3A 0.5% 2% 1% -11.6V to -12.4V MODEL6 MAP130-4000G MAP130-400G MAP130-4002G MAP130-4003G MAP130-4010G 1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3 MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 5 Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 6 Non-G models use lead solder exemption Model numbers highlighted in yellow are not recommended for new designs. 2 [email protected] MAP130 Series PARAMETER 3 CONDITIONS / DESCRIPTION Low Range High Range MIN NOM MAX UNITS 90 175 115 230 132 264 VAC 63 Hz Input Voltage - AC Auto-ranging Input Frequency AC input 47 Brown Out Protection Lowest AC input voltage when regulation is maintained with full rated loads. 90 Hold-up Time Nominal AC input voltage (115 VAC) 40 Input Current 90 VAC, 130 W load Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. Operating Frequency Switching frequency of main transformer. 130 W load: Range: 16 CONDITIONS / DESCRIPTION Efficiency Full Load @ 115 VAC (Varies with distribution of loads among outputs.) Minimum Loads MAP130-1012 MAP130-1024 MAP130-1005 and all multiple output models, main channel only Ripple and Noise Full Load, 20 MHz Bandwidth. Output Power Continuous output power, all multiple output models. Peak output power (60s max., 10% duty cycle), all multiple output models. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on / turn-off. MIN 38 APK 120 kHz MAX UNITS 71% typical Amps See Model Selection Chart Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. PARAMETER NOM ARMS 1.25 0.63 3.00 Varies by output, regulation includes: line changes from 90-132 VAC or 175-264V, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). Transient Response mS 3.3 PARAMETER Regulation VAC CONDITIONS / DESCRIPTION Watts 1 % See Model Selection Chart MIN MAP130-1012 MAP130-1024 All other models 130 165 NOM 17.0 32.0 5.5 500 µS 2 Sec 20 mS MAX UNITS 22.0 37.0 6.8 VDC Overvoltage Protection Provided on single output units and only the main output of multiple output units. Overcurrent Protection All models have inherent short circuit protection. Units will automatically restart at the removal of the fault. Remote Sense Total voltage compensation for main output cable losses. 250 mV Logic LO (denotes power fail detected). 0.7 V kΩ 94 VAC Logic HI with internal pull-up to output. Power Fail Warning 7 Overtemperature Warning 7 8 8 10 Power Fail trip point, maximum load, decreasing line. 86 Time before regulation dropout, at full load, due to loss of input power. Warning prior to system shutdown due to excessive internal temperatures. Shifts Power Fail signal to a logic LO state. 5 ms 20 ms Power Fail not available on MAP130-1012 and MAP130-1024. MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00567_AC Asia-Pacific +86 755 298 85888 MAP130 Series 4 PARAMETER Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference CONDITIONS / DESCRIPTION MIN Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part B - Conducted EN55022 / CISPR 22 conducted EN55022 / CISPR 22 radiated 9 NOM MAX 2121 4242 B B B UNITS VDC Class ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 3 10 ±2 kV 1 2 kV 7 MΩ Input Transient Protection EN61000-4-5 Level 3 Insulation Resistance Input to output Leakage Current Per EN60950, 264 VAC 9 Line to Line Line to Ground 700 μA MAX UNITS 10k 40k Feet 0 0 50 70 °C -40 85 °C ±0.05 %/°C 95 %RH MAP130-1005 meets Class A, radiated. MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV. 10 PARAMETER Altitude CONDITIONS / DESCRIPTION MIN NOM Operating Non-operating Derate linearly above 50°C by 2.5% per °C Operating Temperature 11 At 100% load: At 50% load: Storage Temperature Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) Relative Humidity Non-condensing Shock Operating, peak acceleration 20 GPK Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS MAX UNITS 11 ±0.02 5 External airflow of minimum 23 CFM used in ambient over 25°C. PARAMETER CONDITIONS / DESCRIPTION Dimensions Weight Cover (Option) MIN NOM 215.9 x 114.3 x 50.8 8.50 x 4.50 x 2.00 1.13 2.5 mm in kg lb 215.9 x 114.3 x 55.1 8.5 x 4.5 x 2.17 mm in Order the cover number 412-59586-G separately. For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts. Dimensions: [email protected] MAP130 Series CONNECTOR Input & Output Connectors Matting Connectors Chassis 5 CONDITIONS / DESCRIPTION 6-32 screw wire clamps on 0.312" (7.9 mm) centers, 0.045" (1.1 mm) square pins on 0.156" (3.96 mm) centers, Mates with Molex series 2139, 6442 & 41695 0.035" (0.89 mm) square pins on 0.100" (2.54 mm) centers; Mates with Molex series 2695 & 6471 0.090" (2.286 mm) aluminum alloy with clear finish Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00567_AC Asia-Pacific +86 755 298 85888